| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹9.4 LAccepted-AOC | L1 | Accepted-AOC Lowest and reasonable bid | |
| 2 | L2₹10.3 L+₹86,880 (9.22%)Rejected-Finance M S CHANANA ENGINEERS CONTRACTORS AZAD CHOWK FEROZEPUR CANTT FEROZEPUR PUNJAB 152001 | FIROZEPUR | PUNJAB | 152001 | L2 | Rejected-Finance Other than lowest bid | |
| 3 | L3₹10.4 L+₹95,350 (10.1%)Rejected-Finance 158 PADRI BAZAR TINKONIYA NO 1 PARVATIPURAM GORAKHPUR GORAKHPUR UTTAR PRADESH 273014 | GORAKHPUR | UTTAR PRADESH | 273014 | L3 | Rejected-Finance Other than lowest bid | |
| 4 | L4₹10.5 L+₹1.1 L (11.2%)Rejected-Finance | L4 | Rejected-Finance Other than lowest bid |
Tender Value
₹12 L
EMD Value
₹24,000
Closing Date
2 Sept 2021, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE (EAST) JALANDHAR CANTT
GE (EAST) JALANDHAR CANTT
COMPREHENSIVE MAINT, REPAIRS TO VARIOUS AC PLANTS AT MH JRC UNDER GE (EAST) JALANDHAR CANTT
2021_MES_464095_1
GE/JULL/ET-31/2021-22
Open Tender
Civil Works
Item Rate
335 days
JALANDHAR CANTT
As per tender documents
8 documents required · 8 mandatory
₹500
GARRISON ENGINEER EAST JALANDHAR CANTT
₹24,000
Yes
29 Sept 2021
5 Aug 2021
9 Sept 2021
5 Aug 2021
2 Sept 2021
21 Aug 2021
60 days
Amount
Material and labour for de-scaling of condenser unit-03 Nos for 2 x 50 TR (Working) & 1 x 50 TR (Standby) AC central type with copper tubes by removing nuts & bolts, water connection and filling up of de-scaling acid HCL in condenser and manually cleaning of copper tubes with using nylon brush of superior quality, iron rod for removing of complete scaling from tubes and water circulation through condenser including replacement of rubber gasket, nut & bolts complete all as specified and directed (in OT AC plant in MH)
All as per srl item No. 1.00 here-in-before but of capacity 2 x 10 TR (Working) & 01 x 10 TR (Standby) (X Ray AC Plant)
Material and labour for de-scaling of chiller unit-03 Nos for 2 x 50 TR (Working) & 1 x 50 TR (Standby) AC central type with copper tubes by removing nuts & bolts, water connection and filling up of de-scaling acid HCL in condenser and manually cleaning of copper tubes with using nylon brush of superior quality, iron rod for removing of complete scaling from tubes and water circulation through condenser including replacement of rubber gasket, nut & bolts complete all as specified and directed
All as per srl item No. 3.00 here-in-before but of capacity 2 x 10 TR (Working) & 01 x 10 TR (Standby)
Material and labour for servicing of air handling units 3 x 50 TR AC plant by dismantling, assembling filters and testing for the following parts :- (a) Inspect filters, removing and cleaning by using vaccum cleaner and refix same. (b) Clean cooling coil, fins by using costic soda and water pressure method and applying grease for all motors, check and adjust belt tension if required, check condition of blower shaft, scroll, impeller and bearings, check tightness of all electrical terminations, clean water line strainers, check proper balancing system, check for noise and vibration. (c) Check healthy operation of controls and safety devices.
Material and labour for servicing of air handling units 3 x 10 TR AC plant by dismantling, assembling filters and testing for the following parts :- (a) Inspect filters, removing and cleaning by using vaccum cleaner and refix same. (b) Clean cooling coil, fins by using costic soda and water pressure method and applying grease for all motors, check and adjust belt tension if required, check condition of blower shaft, scroll, impeller and bearings, check tightness of all electrical terminations, clean water line strainers, check proper balancing system, check for noise and vibration. (c) Check healthy operation of controls and safety devices.
Material and labour for disconnecting electric motor 7.5 HP and transporting to workshop, dismantling the same and taking out rotor assembly removing burnt winding coil of stator, cleaning the complete stator and rotor with carbon tetra chloride solution, rewinding the stator coil with super enameled copper conductor of proper size/gauge as per existing, inserting the new re-winded coils of stator duly varnishing and insulated with superior quality insulation material, replacement of old connection lead with superior quality PVC insulated FRLS wire with stranded copper conductor with sleeves from motor to connection plate, reassembling the motor, shifting to site, connecting, commissioning and testing on full load complete all as specified and as directed.
All as per srl item No 7.00 here-in-before but 5 HP electric motor.
All as per srl item No 7.00 here-in-before but 3 HP electric motor.
All as per srl item No 7.00 here-in-before but 2 HP electric motor.
All as per srl item No 7.00 here-in-before but of 1 HP, single phase electric motor.
All as per srl item No 7.00 here-in-before but of 250W, single phase electric motor.
Material and labour for check for any refrigerant leaks through flare joints, valve glands and complete refrigerant system with requires leak detector for 50 TR central type AC plant complete all as specified and directed
Material and labour for charging N2 or Nitrogen Gas in 2 x 10 TR working capacity with 1 x 10 TR standby AC plant maintaining pressure 350 Psi for checking of Gas leakage and removing water vapour choked in line, flushing out the complete system including gas leakage and detection with halide torch/ soap foam solution in system including gas welding flushing and making good the pipe line to make the system leak proof complete all as specified and as directed.
All as per srl item No 14.00 here-in-before but of capacity 2 x 50 TR working with 1 x 50 TR standby.
Material and labour for vaccumising the plant by using vaccum pump upto (-) 30 PSIG pressure and hold the same under vaccum pressure upto 24 hours including necessary welding and bracing if required complete all as specified and directed for 10TR/ 50 TR AC Plant.
Supply and charging refrigerant Gas R-22 in central AC plant of various capacities including complete labour charges for checking leakage and maintaining proper pressure after filling of Gas complete all as specified or as directed.
All as per srl item No 17.00 here-in-before but R-407 or equivalent
All as per srl item No 17.00 here-in-before but R-410 or equivalent
Supply and filling in fresh compressor oil N-68 for compressor of AC plant of various capacities to ensure the development of required oil pressure complete all as specified and as directed. Make: Indian Oil/ Bharat Petroleum/ Servo. Note: Compressor oil shall be supplied in company sealed containers only.
Supply, install, testing and commissioning of chiller control unit control unit with display board complete set suitable for 50 TR central type AC plant as per existing pattern and make it functional all as directed Make : Softhard or equivalent as approved by GE.
Supply, install, testing and commissioning of package type AC control unit with display board complete set suitable for 15/22 TR multi unit AC plant as per existing pattern and make it functional all as directed
Supply and fixing in replacement of discharge pressure gauge 4” dia, range 0 to 300 Psi complete all as specified or as directed. Make: Fiebig/ Guru/ York
Supply and fixing in replacement of Oil pressure gauge 4” dia, range 0 to 200 Psi complete all as specified or as directed. Make: Fiebig/ Guru/ York
Supply and fixing in replacement of suction pressure gauge 4” dia, range 0 to 150 Psi complete all as specified or as directed. Make:- Fiebig/ Guru/ York
Supply and fixing in replacement of water pressure gauge 4” dia, range 0 to 100 Psi complete all as specified or as directed. Make:- Fiebig/ Guru/ York
Supply and fixing in replacement V- belt B-68 heavy duty complete all as specified or as directed. Make: Fenner/ Navyug/ Dunlop
All as per Srl item No 27.00 here-in-before but size B-70
All as per Srl item No 27.00 here-in-before but size B-72.
All as per Srl item No 27.00 here-in-before but Size B-94
Supply and fixing in replacement V- belt A-31 heavy duty complete all as specified and as directed. Make:- Fenner/ Navyug/ Dunlop
All as per Srl item No 31.00 here-in-before but size A-32
All as per Srl item No 31.00 here-in-before but size A-34
All as per Srl item No 31.00 here-in-before but size A-36
Supply and fixing in replacement of thermostat expansion valve suitable for AC plant 50 TR capacity complete all as specified and directed. Make: Sporlan/Danfoss/Renutrol or equivalent
All as per srl item No 35.00 here-in-before but suitable for 20 TR capacity AC Plant.
Supply and fix in replacement finned strip heater made of PG sheet having terminals at one end and two holes for horizontal installation of capacity 3 KW in Air Conditioning plant installed at various locations complete all as specified and directed. Make:- Daspass/ Lazer/ Usha
Supply and fixing fine filter of size 24" x 12" x 2" having dust filtration level 5 micron 95% efficiency as per existing type, make & size complete all as specified and as directed.
Supply and fixing fine filter of size 24" x 24" x 2’ having dust filtration level 5 micron 95% efficiency as per existing type, make & size complete all as specified and as directed.
Supply and fixing fine filter of size 520mm x 460mm x 60mm having dust filtration level 5 micron 95% efficiency as per existing type, make & size complete all as specified and as directed
Supply and fixing fine filter of size 505mm x 420mm x 50mm having dust filtration level 5 micron 95% efficiency as per existing type, make & size complete all as specified and as directed
Supply and fixing Hepa filter of size 24" x 24" x 12" having dust filtration level 0.3 micron 95% efficiency as per existing type, make & size complete all as specified and as directed
Servicing/ maintenance of packaged type AC plant of capacity 2 x 5.5/ 2x 10 TR such as cleaning of fine filter with water, checking gas and gas leakage, cleaning of condensing coil with water for better performance of AC plant, cleaning and greasing of condensing blower motor, AHU blower motor and booster blower motor and cleaning of condensers unit, checking tightening of all electrical connections complete all as directed.
All as per Srl item No 43.00 here-in-before but suitable for 2 x 15/ 3 x 15TR.
All as per Srl item No 43.00 here-in-before but suitable for 3 x 22 TR capacity AC plant.
Preparation of old painted surfaces of AC plant central type of working capacity 3 x 50 TR including all motors, condensers, pumps, MS Pipes of various sizes, cooling tower and LT electric panel board installed at Heat stroke plant room painting with super enameled paint of approved quality with spray gun two coats over a coat of red oxide paint complete all as specified and as directed.
All as per srl item No 46.00 here-in-before but AC plant of working capacity 3 x 10 TR installed at X-Ray.
Replacement of PVC honey comb fills (drift eliminators) suitable size of central type AC plant complete all as specified and directed
Supply and fixing in replacement compressor 7.5 TR, model 06D/ 018 for Voltas Packaged unit Model DUPA SH 1500 including gas charging and testing complete installed at ICU all as per specified and directed. Make- DANFOSS/ KIRLOSKAR/TECHMSAH
Supply and fixing connecting and testing of compressor scroll sealed unit of capacity 5.5 TR performer, for package type AC plant/ cold store including gas charging and testing complete all as specified and directed. Make: DANFOSS/ KIRLOSKAR/ TECHMSAH
All as per srl item No 50.00 here-in-before but 11 TR.
Servicing of LT AC plant panel board of any size including connected AHU starter panels and wirings, cleaning of panel board internally and externally, tightening of all screws and nut & bolts, replacing of minor parts like screws, washers, lugs etc, checking of serviceability of all switch gears complete all as specified and directed
Supply and fixing in replacement star delta timer electronic 240V, 50 Hz, 3-30 Sec. Make - L & T suitable for star delta starter
Supply and fixing in replacement ON/ OFF Push button with element complete all as directed.
Supply and fixing in replacement PCB in the existing packed unit/ cold room AC plant including necessary control wiring as required. Model No - 22 TR PMN MPD Twin Make: Softhard automation Pvt Ltd or in equivalent.
Supply and fixing in replacement PCB in the existing Packed unit/ cold room AC Plant including necessary control wiring as required. Model No - 15 TR PMN MPD Twin. Make: Softhard automation Pvt Ltd or in equivalent.
Supply and fixing contactor MNX, 32 amp complete all as specified and as directed. Make: L&T/ Schneider/ Siemens/ BCH.
Supply and fixing in replacement Contactor MNX, 45 amp complete all as specified and as directed. Make: L&T/ Schneider/ Siemens/ BCH.
Supply and fixing in replacement Contactor MNX, 25 amp, 3 pole complete all as specified and as directed. Make: L&T/ Schneider/ Siemens/ BCH.
Supply and fixing in replacement of indicator neon lamp complete all as specified and as directed.
Supply and fixing in replacement ammeter analog type 0-200 Amp, 96mm x 96mm CT operated complete all as specified and as directed. Make- L&T/ Schiender/ Indotech
Supply and fixing in replacement of Ammeter analog type 0-100 Amp, 96x96mm complete all as specified and as directed.MakeCTs 30/5. Make- L&T/ Schiender/ Indotech
Supply and fixing in replacement of Ammeter analog type 0-50 Amp, 96x96mm complete all as specified and as directed.MakeCTs 30/5. Make- L&T/ Schiender/ Indotech
Supply and fixing in replacement of Voltmeter analog type 0-500 Amp, 96x96mm complete all as specified and as directed. Make- L&T/ Schiender/ Square
Supply and fixing in replacement ball bearing of size 6205 all as specified and directed. Make- SKF/ NBC/ TATA.
Supply and fixing in replacement ball bearing of size 6306 all as specified and directed. Make- SKF/ NBC/ TATA.
Supply and fixing in replacement ball bearing of size 6307 all as specified and directed. Make- SKF/ NBC/ TATA.
Supply and fixing in replacement ball bearing of size 6308 all as specified and directed. Make- SKF/ NBC/ TATA.
Supply and fixing in replacement toggle 5 Amp switch two way brass handle as per sample all as directed.
Supply and fixing in replacement LP HP cut out M15 as per sample all as directed. Make- Danfoss/ Indfoss/ Renutrol or equivalent.
Supply and fixing in replacement compressor shaft oil seal of voltas 50 TR complete all as specified and directed. Make-Voltas or equivalent
Supply and fixing in replacement compressor shaft seal of 10 TR complete all as specified and directed. Make- Accel Sabro or equivalent
Supply, installation of GI construction volume control dampers, lever operated type as per specifications including required accessories complete all as specified and directed
Servicing/ repairing of cooling tower of capacity 20 TR plant by supply and fixing of nozzles, oiling, greasing of tower fan and motor cleaning, descaling of complete fins including replacement of broken fins, cleaning water tray, valves, piping etc and testing complete all as per specified and directed.
Servicing/ repairing of cooling tower of capacity 100 TR plant by supply and fixing of nozzles, oiling, greasing of tower fan and motor cleaning, descaling of complete fins including replacement of broken fins, cleaning water tray, valves, piping etc and testing complete all as per specified and directed.
Supply and fixing automatic expansion valve for 50 TR OT plant Model No - MVE 42 CP 100.
Supply and fixing main contactor type 3TF 46. Make - Siemens/BCH/L&T/Schneider
Supply and fixing star delta main contactor type 3TF 34. Make - Siemens/BCH/L&T/Schneider
Supply and fixing in replacement over load Relay 6 to 10 Amp all as specified and directed. Make - Siemens/ BCH/ L&T/ Schneider
Supply and fixing metallic air filter made out of galvanized iron frame and meshing of size 585mm x 630mm x 50mm having dust filtration level 30 micron 70% efficiency suitable for central AC plant complete all as specified and as directed.
Supply and fixing metallic air filter made out of galvanized iron frame and meshing of size 460mm x 560mm x 150mm with non-woven synthetic media having dust filtration level 5 micron 90% efficiency suitable for central AC plant complete all as specified and as directed.
Supply, fixing, connecting and testing condenser fan motor of outdoor air cooled condensers of AC plant/ cold store capacity 5/ 5.5/ 11 TR make Blue Star as per existing type and size including taking out of unserviceable motor complete all as specified and directed
Supply, fixing, connecting and testing evaporator fan motor of cold store capacity 5 / 5.5 TR make Blue Star as per existing type and size including taking out of unserviceable motor complete all as specified and directed
Supply, fixing, connecting and testing molecular drier cum strainer on line type of size 3/8" x 3/8" dia make danfoss in AC plant capacity 5.5 TR make Blue Star including taking out of unserviceable drier complete all as specified and directed
Servicing/ maintenance of walk-in cooler of capacity 9000 ltr with PUF panel cabin such as checking gas and gas leakage, cleaning of condensing coil with water for better performance of cold store, cleaning and greasing of condensing blower motor, cooling fan motors, cleaning and washing of complete indoor and outdoor unit and PUF cabin, cleaning of condensers unit, checking tightening of all electrical connections complete all as specified and directed
Servicing/ maintenance of cold store of capacity 2 x 5.5 TR such as checking gas and gas leakage, cleaning of condensing coil with water for better performance of cold store, cleaning and greasing of condensing blower motor, cooling fan motors, cleaning of condensers unit, checking tightening of all electrical connections complete all as specified and directed
Servicing/ maintenance of cold store of capacity 1 x 8.5 TR such as checking gas and gas leakage, cleaning of condensing coil with water for better performance of cold store, cleaning and greasing of condensing blower motor, cooling fan motors, cleaning of condensers unit, checking tightening of all electrical connections complete all as specified and directed
Supply and fixing rolled mild steel joist, channel, angle or tee sections fixed independently, without connecting plates, ( cut to ordinary lengths i.e. within 20 mm of the length ) etc confirming to Gde Fe-410-W (Gde -E-250) quality 'A' complete all as specified and directed (for making sliding gate).
Cutting of MS pipe line of size 150mm/ 65mm and jointing new MS pipe including welding work complete all as specified and directed
Supply and fixing in replacement flanged MS pipe heavy grade 150mm dia bore complete all as specified and directed
Supply and fixing in replacement flanged MS pipe heavy grade 65mm dia bore complete all as specified and directed
Supply and fixing in replacement strainer Y type conforming to IS, size 150mm dia complete all as specified and directed
Supply and fixing in replacement flanged butterfly valve for MS pipe heavy grade 150mm dia complete all as specified and directed
Supply and fixing in replacement gate valve for GI pipe 25mm dia both side female screwed complete all as specified and directed
Supply and fixing in replacement GI pipe medium grade 25mm dia with all fittings bends, unions, tees, etc. complete all as specified and directed
Chanana Engineers & Contractors
CHOUDHARY AND SONS
LOVELY AIRCON SYSTEM
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .