| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹6.2 LAccepted-AOC 275 2 AJIT NAGAR UPPER GADIGARH AIRPORT ROAD JAMMU 181101 | JAMMU | JAMMU | JAMMU AND KASHMIR | 181101 | L1 | Accepted-AOC Lowest and Reasonable | |
| 2 | L2₹6.4 L+₹18,490 (3.00%)Rejected-Finance BASTI GOVINDPURA SIMBAL MORH MAKHANPUR GOJRAN JAMMU J K 181101 | JAMMU | JAMMU AND KASHMIR | 181101 | L2 | Rejected-Finance Other than Lowest | |
| 3 | L3₹6.7 L+₹50,345 (8.16%)Rejected-Finance 0 MANPUR CHITBARAGAON CHITBARAGAON BALLIA UTTAR PRADESH 221713 | BALLIA | UTTAR PRADESH | 221713 | L3 | Rejected-Finance Other than Lowest | |
| 4 | L4₹6.9 L+₹74,708 (12.1%)Rejected-Finance B 56 LANE NO 4A SECTOR 7 VASHNAVI ENCLAVE CHANNI HIMAT JAMMU 180015 | JAMMU | JAMMU AND KASHMIR | 180015 | L4 | Rejected-Finance Other than Lowest | |
| 5 | L5₹9.5 L+₹3.3 L (53.8%)Rejected-Finance C O SECTOR 02 HOUSING COLONY CHANNI HIMMAT JAMMU J K PIN 180015 | JAMMU | JAMMU AND KASHMIR | 180015 | L5 | Rejected-Finance Other than Lowest |
Tender Value
₹10 L
EMD Value
₹20,000
Closing Date
11 May 2023, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
CWE (AF) Jammu
Headquarters, CWE (AF) Jammu Near Gurdwara Sahib and Mandir Airforce Station Satwari, Jammu Pin 180 003
REPAIR / REPLACEMENT OF HT OH LINES WORK AT SHASHITAR AND SALYARCHATTA UNDER AF STN JAMMU
2023_MES_589421_1
CWEAFJ-01/2023-24
Open Tender
Civil Works
Item Rate
180 days
GE (AF) Jammu
Please refer NIT and Tender Documents
9 documents required · 9 mandatory
₹500
Yes
GE (AF) Jammu
₹20,000
Yes
23 Jun 2023
13 Apr 2023
13 May 2023
13 Apr 2023
11 May 2023
27 Apr 2023
Amount
Excavating in trenches, not exceeding 1.5metre wide and not exceeding 1.5metre depth for foundation, etc., and getting out in any type of soil, complete all as specified and directed.
Excavating in trenches, not exceeding 1.5metre wide and exceeding 1.5metre depth but not exceeding 3.0metre depth for foundation, etc., and getting out in any type of soil, complete all as specified and directed.
Returning, filling in, including spreading, leveling, watering and well ramming in layers not exceeding 25 cm thick any type of soil, complete all as specified and directed.
Removing excavated soils to a distance exceeding 50m but not exceeding 100m and depositing where directed at a level not exceeding 1.5m above the starting point complete all as specified and directed.
Cement concrete type D-2 1:4:8 (using 40mm graded crushed stone aggregate) as in foundation filling and mass concrete, complete all as specified and directed.
Cement concrete type C-2 1:3:6 (using 40mm graded crushed stone aggregate) as in foundation filling and mass concrete, complete all as specified and directed.
Cement concrete type B-1 1:2:4 (using 20mm graded crushed stone aggregate) as in coping of poles, complete all as specified and directed.
Steel Tubular swaged poles type 410 SP-55 (11.0 mtr long) conforming to IS : 2713 Part-I to III 1980, complete with 6 mm thick mild steel base plate, finial taper plug, MS bolts, nuts, screws including painting upto 1.5metre above PCC coping in black and white strips 05 Nos of 30cms each starting from the bottom of the pole and two coats epoxy based paint aluminium grade finish to the remaining external surface over one coat of primer and writing Pole No complete including taking down old unserviceable Pole all as specified and as directed.
Cross arm bracings, supports, clamps and back plates fabricated from structural steel sections including nuts, bolts, washers, drilling holes for bolts, in any shape or size as indicated or directed and also inclusive of two coats of aluminium paint over one coat of red oxide primer including dismantling / taking down old unserviceable structural steel all as specified and as directed.
Stay assembly complete with accessories as shown in Electrical Plate No.1 of SSR 2009 Part-I using stay rod of 20 mm dia, stay bow 14 mm dia, 400 mm long, MS Plate of size 230 x 230 mm x 6mm thick, stay GI wire 7/4mm dia, including loop type insulator large size with overall dimensions 180mm dia, clearance of hole 25.5mm and stay clamps etc. (excavation and concrete shall be measured and paid separately) complete all as specified and directed.
Aluminium conductor steel reinforced (ACSR) including binding to insulator with suitable size of binding wire and size of conductor Weasel (6/1 x 2.59 mm), Squirrel (6/1 x 2.11mm) or Ferret (6/1 x 3.00 mm) all as specified and as directed.
Galvanised Guard wire / Cradles / Stay wires complete as required at site all as specified and directed.
Pin type porcelain vitreous white, brown or green insulator including one galvanized mild steel spindle, two galvanized iron washers and one galvanized iron nut, 150mm height, 150mm dia for 11000 volt complete including taking down old unserviceable insulator complete all as specified and directed.
Disc type porcelain vitreous white or brown insulator including GI straps, washers, insulator bolts and nuts for working pressure 11000 volts, 145 mm height, 255 mm dia, complete all as specified and as directed.
Switch Air break, gang operated (GOD) with 15 Nos insulators in replacement, outdoor type, Three Pole mechanically operated, suitable for vertical installation, Single break, provided with locking arrangements consisting of MS channel, HT Post type insulator copper alloy, high Pressure, Assembly operating rod 25 mm dia GI pipe medium grade for operating from 1.2 metre above Ground Level with locking arrangement complete confirming to IS-1318 of 1972 rated voltage 11 KV and for current rating 200 Amps complete, including taking down old unserviceable GOD all as specified and directed.
Lightning Arrestors, expulsion type, complete with all fittings, transmission class, discharge capacity 65 KA suitable for 11000 Volts grade and entire satisfaction complete, including taking down old unserviceable LA all as specified and directed.
Cutting and trimming of trees and branches to clear the over head line in the arc of HT/LT over head line feeders and removal of the trimmed branches of trees complete all as specified and directed. Notes : 1. Any ACSR conductor damaged during the cuttings of trees / branches shall be repaired and jointed / fixed by the contractor, to the entire satisfaction of Engr-in-Charge, without any extra cost and nothing extra shall be admissible from the department on this account what-so-ever. 2. The cutting / trimming of tree branches shall be done to at least 3.00 metre radius of OH line. 3. The unit of measurement is 'SPAN' i.e. distance covered between two adjacent poles.
Cutting wild grass, bushes, creepers, unwanted vegetations, etc. from surrounding poles / stays including cleaning creper climbed on Poles as and when directed and removing the spoil and depositing where directed (size of cutting 90cm x 90cm around Pole / Stay) to the entire satisfaction of Engr-in-Charge complete all as specified and directed.
Anti-climbing device spikes type fabricated out of M.S. bars (round, square and flat) including nuts, bolts, washers and welding in two halves made to shape to suit the cross section of the pole and duly painted with synthetic enamel aluminium / smoke grey paint over a coat of primer complete, including taking down old unserviceable Anti-climbing device all as specified and directed
Danger notice plate, for LT, of size 20cm x 15cm x 1.5mm thick mild steel sheet, vitreous enameled, white with letters, figures and conventional Skull & Bones in signal red colour and fixed with MS clamps, bolts and nuts of appropriate size, all as specified and as directed.
Danger notice plate, for HT, of size 25cm x 20cm x 1.5mm thick mild steel sheet, vitreous enameled, white with letters, figures and conventional Skull & Bones in signal red colour and fixed with MS clamps, bolts and nuts of appropriate size, all as specified and as directed.
Supplying laying jointing and testing XLPE insulated, PVC bedded, galvanised steel strips armoured heavy duty electric power cable with stranded aluminium conductor suitable for rated voltage of 11000 Volt grade, 3 Core x 95 Sqmm conforming to IS 7098 Part-2) 2011 with upto date amendments and laid in trenches / ducts / pipe or on poles complete, including taking down old existing unserviceable cable all as specified and directed.
Supplying laying jointing and testing XLPE insulated, PVC bedded, galvanised steel strips armoured heavy duty electric power cable with stranded aluminium conductor suitable for rated voltage of 1100 Volt grade, 3.5 Core x 50 Sqmm conforming to IS 7098 Part-I) 1988 with upto date amendments and laid in trenches / ducts / pipe or on poles complete, including taking down old existing unserviceable cable all as specified and directed.
Sand cushioning to underground cables using new dry river sand laid in trenches 8cm thick below the cable and 15cm thick above the cable after laying and stretching the cable complete, punned to 18cm, complete all as specified and directed Note : Punned thickness of 18cms shall be measured for payment.
Supplying and laying un-reinforced precast concrete cable cover, Class HV, type 1, size 300mm x 180mm x 40mm, complete all as specified and as directed.
Cable jointing kit for 11 KV (earthed) grade cable for straight through heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 70 to 95 Sqmm complete all as specified and as directed.
LT Porcelain bushing with brass stud screwed with brass nuts, bolts and cork washer for transformer of capacity 100 KVA to 200 KVA, 415 volts Three Phase 4 wire system all as specified and as directed.
LT Porcelain bushing with brass stud screwed with brass nuts, bolts and cork washer for transformer of capacity 250 KVA to 315 KVA, 415 volts Three Phase 4 wire system all as specified and as directed.
HT 11 KV porcelain bushing with brass stud screwed with brass nuts, bolts and cork washer for transformer of capacity 100 KVA to 200 KVA all as specified and directed.
HT 11 KV porcelain bushing with brass stud screwed with brass nuts, bolts and cork washer for transformer of capacity 250 KVA to 315 KVA all as specified and directed.
Rewinding of dimmer coil (Various) of stabilizer of any capacity with super enamelled copper winding wire of appropriate gauge as per existing pattern alongwith insulating material and made the surface for suitable contact with carbon bush complete after removing existing burnt winding wire and cleaing complete all as specified and directed.
Spray Painting of complete Transformer, of capacity 100 KVA to 315 KVA, with one coat of weather proof grey synthetic enamel paint after cleaning / removing dust, rust or carbon etc. including writing MES No / SM No complete all as specified and as directed.
Supply, filling and top up with new Transformer Oil of dielectric strength more than 40 KV at 2.5mm gap confirming to IS : 335-1993 complete all as specified and as directed.
Dehydration of transformer oil by using filtration plant of suitable capacity and removing the moisture / dust till obtaining the oil dielectric strength 35 KV at 2.5mm gap and above for various transformer / voltage stabilizer of any size located at different substations, complete all as specified and as directed.
Taking out Servo Voltage Stabilizer of capacity 250 to 300 KVA, Three Phase, 4 wire AC supply 440 V for Unbalanced / Balanced load oil cooled from foundation after disconnecting all electrical connections etc. dismantling for pre inspection by lifting of assembly and repairing / replacement of worn out parts and testing after re-installation on same foundation complete all as specified and as directed. Note : Parts required for replacement shall be measured and paid separately under relevant item(s).
Taking out Servo Voltage Stabilizer of capacity 100 to 200 KVA, Three Phase, 4 wire AC supply 440 V for Unbalanced / Balanced load oil cooled from foundation after disconnecting all electrical connections etc. dismantling for pre inspection by lifting of assembly and repairing / replacement of worn out parts and testing after re-installation on same foundation complete all as specified and as directed. Note : Parts required for replacement shall be measured and paid separately under relevant item(s).
Rewinding of dimmer coil (Various) of stabilizer of any capacity with super enamelled copper winding wire of appropriate gauge as per existing pattern alongwith insulating material and made the surface for suitable contact with carbon bush complete after removing existing burnt winding wire and cleaning complete all as specified and directed.
Earthing complete with galvanised steel earth plate electrode 600 mm x 600 mm x 6 mm thick buried directly in ground vertically (earth plate not less than 2.25 m deep below normal ground level) with top edge of the plate not less than 1.5 m below normal ground level connected to and including earth lead of GI earth lead wire 4.00 mm dia by means of G.I. thimbles, bolts, nuts, check nuts and washers, PCC 1:2:4 type B - 1 (using 20mm graded crushed stone aggregate), in pit, angle iron 25 x 25 x 3 mm frame work with precast RCC 1:2:4 type B-1 (using 20 mm graded crushed stone aggregate) cover reinforced with 8 mm dia TMT bars @ 150 mm C/C both ways and 12 mm dia MS fabricated handle, light grade GI watering pipe 20 mm bore with funnel, wire mesh
and light grade GI protection pipe 15 mm bore upto 7.5 m length for drawing in earth lead, salt, charcoal etc. including excavation and earth work in any type of soil, removal of surplus soil to a distance not exceeding 50 m complete all as shown in electrical plate No. 3 of MES schedule 2009 Part-I Including connecting and testing on completion all as specified and as directed.
Earth continuity conductor or main earthing lead using 4 mm dia galvanised iron or steel wire fixed to wall on batten or recess or chases or burried in ground or drawn in conduit/pipe or fixed to poles or any other indicated situation for loop earthing etc. as required including taking down old wire complete all as specified and directed.
J P TECHNO
NATIONAL TRADING COMPANY
ANIKET TRADERS
MAMTA ENTERPRISES
Bidder Name
ANIKET TRADERS
MAMTA ENTERPRISES
GENESIS INDIA
NATIONAL TRADING COMPANY
J P TECHNO
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .