Loading…
Loading…
| # | Company | Status |
|---|---|---|
| 1 | Admitted-Finance | Admitted-Finance |
| 2 | Admitted-Finance CHENNAI | CHENNAI | TAMIL NADU | 600001 | Admitted-Finance |
Tender Value
₹18.0 L
EMD Value
₹35,960
Closing Date
3 Aug 2023, 2:30 pmClosed
The Chief Mechanical Engineer
O/o The Chief Mechanical Engineer, Chennai Port Authority, 7th floor, Centenary Building, No.1 Rajaji Salai, Chennai 600 001
Improvement of Electrical System in Shri Babu Jagajivan Ram Sports Complex at Tondiarpet Housing Colony in Chennai Port Authority under two cover system
2023_ChPT_761877_2
MEE/45/2023/DyCME MP and OH
Open Tender
Electrical Works
Works
60 days
Chennai Port Authority
As per Tender document
15 documents required · 15 mandatory
₹0
₹35,960
11 Sept 2023
14 Jul 2023
4 Aug 2023
21 Jul 2023
3 Aug 2023
21 Jul 2023
Removing of existing main switch board from Gallery Room No.4 and reinstalling the same in Gallery Room No.7.
Dismantle the existing old wiring, distribution board, switch boxes, ceiling fans, tube lights etc., from sports complex and same to be handed over to 11 KV Sub-station at T.H.Colony.
Supply of LED 1x20 Watts, 230 V batten type cool white tube light
Installation of LED 1x20 Watts, 230 V batten type cool white tube light as detailed in Schedule ‘A’.
Supply of 1200 mm sweep, double ball bearing brown colour ceiling fan suitable for 230 V AC operation with step type electronic fan regulator.
Installation of 1200 mm sweep, double ball bearing brown colour ceiling fan suitable for 230 V AC operation with step type electronic fan regulator as detailed in Schedule ‘A’.
Supply of high speed 12” (300) mm dia exhaust fans.
Installation of high speed 12” (300) mm dia exhaust fans as detailed in Schedule ‘A’.
Supply of 450 mm high speed 1400 rpm 230 V Pedestal Fan
Supply of 1x100 watts LED flood light fittings.
Installation of 1x100 watts LED flood light fittings as detailed in Schedule ‘A’.
Supply of 1x150 watts LED flood light fittings.
Installation of 1x150 watts LED flood light fittings as detailed in Schedule ‘A’.
Supply of 1x400 watts LED flood light fittings.
Installation of 1x400 watts LED flood light fittings as detailed in Schedule ‘A’.
Supply and installation of GI Square tube channel for fixing of 8 Nos.of 400 Watts LED Flood lights as shown in the drawing.
Supply of 100 A, 25 KA, 4 Pole MCCB.
Installation of 100 A, 25 KA, 4 Pole MCCB to be mounted on existing main switch board.
Supply of 63 A, C-Series, 4 Pole MCB
Installation of 63 A, C-Series, 4 Pole MCB to be mounted in existing main switch board.
Supply of 32 Amps, C-Series, 2 Pole MCB with PC/FRP/SMC suitable size enclosure
Installation of 32 Amps, C-Series, 2 Pole MCB with PC/FRP/SMC suitable size enclosure as detailed in Schedule ‘A’.
Supply of FRP/SMC/PC Distribution Board for controlling 1x150 W LED flood light fitting as per Schedule ‘A’.
Installation of FRP/SMC/PC Distribution Board for controlling 1x150 W LED flood light fitting as per Schedule ‘A’.
Supply of all materials and accessories to carry out the surface / concealed conduit wiring by suitable size of PVC pipe with 2 runs of 1.5 sq.mm. and one run of 1.0 sq.mm. for earth PVC insulated unsheathed copper conductor wires for fan, light fittings, passage focus fittings, exhaust fan etc., through connected junction box / inspection box along with 5A modular flush type control switch along with base plates and ceiling rose including terminations wherever necessary from modular type sub switch board in each room to individual points in each room
Supply of 5 Amps switch and socket outlet
Installation of 5 Amps switch and socket outlet to be mounted on the modular type switch board and wiring to the switch as detailed in Schedule ‘A’.
Supply of 2 nos. 5 A modular type switch with 2 nos. socket outlet along with base plates and switch box.
Installation of 2 nos. 5 A modular type switch with 2 nos. socket outlet along with base plates and switch box as detailed in Schedule ‘A’.
Supply of 15 A / 5 A modular type switch with socket outlet along with base plates and switch box.
Installation of 15 A / 5 A modular type switch with socket outlet along with base plates and switch box as detailed in Schedule ‘A’.
Supply of conduit wiring PVC pipe with 2 runs of FR 2.5 Sq.mm. and one run of FR 1.5 Sq.mm. for earth copper conductor.
Installation of conduit wiring PVC pipe with 2 runs of FR 2.5 Sq.mm. and one run of FR 1.5 Sq.mm. for earth copper conductor as detailed in Schedule ‘A’.
Supply of conduit wiring PVC pipe with 2 runs of FR 4 Sq.mm. and one run of FR 2.5 Sq.mm. for earth FR copper conductor
Installation of conduit wiring PVC pipe with 2 runs of FR 4 Sq.mm. and one run of FR 2.5 Sq.mm. for earth copper conductor as detailed in Schedule ‘A’.
Supply of conduit wiring PVC pipe with 2 runs of FR 6 Sq.mm. and one run of FR 2.5 Sq.mm. for earth FR copper conductor
Installation of conduit wiring PVC pipe with 2 runs of FR 6 Sq.mm. and one run of FR 2.5 Sq.mm. for earth copper conductor as detailed in Schedule ‘A’.
Supply of 4 core x 25 Sq.mm. LT UG Alu. Armoured cable as per Schedule ‘A’.
Laying of 4 core x 25 Sq.mm. LT UG Alu. Armoured cable as detailed in Schedule ‘A’.
Supply of 3 ½ Core x 185 Sq.mm. LT UG Alu. armoured cable as per Schedule ‘A’.
Laying of 3 1/2 Core x 185 Sq.mm. LT UG Alu. armoured cable as detailed in Schedule ‘A’.
Clamping of 3 1/2 Core x 185 Sq.mm. LT UG Alu. armoured cable as detailed in Schedule ‘A’.
Supply of 5 core x 4 Sq.mm. Copper ERP coated flexible trailing cable
Laying of 5 core x 4 Sq.mm. Copper ERP coated flexible trailing cable as detailed in Schedule ‘A’.
Supply of all materials of maintenance free earthing as per Schedule ‘A’.
Earthing as detailed in Schedule ‘A’.
Excavation of soil for a depth of 3 feet x 1 feet breadth and refill the trench with soil and compacting. as details in Schedule ‘A’
Testing and commissioning of entire work.
CIVICONS
stage.html
html • 0.03 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.05 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .