Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹21.2 LAdmitted-Finance SWAGAT CO OP HSG SOCIETY LTD 22 303 CHAITANYA SHIVAJI RAJE COMPLEX MHADA COMPLEX OPP EKA NAGAR KANDIVALI W MUMBAI 400 067 | MUMBAI | MUMBAI SUBURBAN | MAHARASHTRA | 400067 | ₹21.2 L | L1 | Admitted-Finance |
| 2 | L2₹28.4 L+₹7.2 L (33.8%)Admitted-Finance | ₹28.4 L+₹7.2 L (33.8%) | L2 | Admitted-Finance |
| 3 | L3₹29.2 L+₹8.0 L (37.5%)Admitted-Finance SHOP NO 10 BMC SHOPPING CENTRE MITHA NAGAR GOREGAON WEST MUMBAI 400 104 | MUMBAI | MUMBAI SUBURBAN | MAHARASHTRA | 400104 | ₹29.2 L+₹8.0 L (37.5%) | L3 | Admitted-Finance |
| 4 | L4₹29.9 L+₹8.6 L (40.5%)Admitted-Finance | ₹29.9 L+₹8.6 L (40.5%) | L4 | Admitted-Finance |
| 5 | L5₹30.0 L+₹8.8 L (41.3%)Admitted-Finance SHOP NO 12 KHOPKAR APARTMENT KUMBHARAWADA URAN DISTT RAIGAD 400 702 | URAN | RAIGAD | MAHARASHTRA | 400702 | ₹30.0 L+₹8.8 L (41.3%) | L5 | Admitted-Finance |
| Sl No | Description | Qty | Unit | SHRI SAI ENTERPRISES L8 | ENJOY L5 | AIRDOT ENGINEERING L2 | somnath engineering corporation L4 | sapana enterprises L6 | cooltech engineering services L1 | Shree Ayyappa Engineering L3 | Pioneer Enterprises L7 | pk Enterprises L10 | shakti engineering and electrical works L9 |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| 1.00 | Supply, fabrication, and erection of factory-fabricated rectangular or square duct made out of 24-gauge (0.63 mm thick) G.I. sheet conforming to IS: 277 with zinc coating not less than 120 gsm, formed to the required shape and size in L-shaped hollow profile. The work shall include all accessories such as corner pieces, flanges, gaskets, approved duct sealant, G.I. nuts, bolts, carriage bolts, hangers, supports, and all materials required for proper installation complete all as specified and directed by Engineer_in_charge. | 300 | Sqm | 1,300 ₹3,90,000 | 1,900 ₹5,70,000 | 1,695 ₹5,08,500 | 1,500 ₹4,50,000 | 1,800 ₹5,40,000 | 1,190 ₹3,57,000 Lowest | 1,750 ₹5,25,000 | 1,300 ₹3,90,000 | 1,800 ₹5,40,000 | 1,200 ₹3,60,000 |
| 2.00 | Taking down carefully the existing rectangular or square G.I. ducting of any gauge or size including all connected fittings, accessories, thermal insulation, wire mesh/net, supports, hangers, and sealing material. The work shall include cutting, dismantling, unscrewing, or unbolting joints, lowering the ducts safely from the ceiling or wall, and stacking serviceable material complete all as specified & directed by Engr-in-charge. | 300 | Sqm | 300 ₹90,000 | 320 ₹96,000 | 45 ₹13,500 Lowest | 325 ₹97,500 | 230 ₹69,000 | 170 ₹51,000 | 225 ₹67,500 | 320 ₹96,000 | 231 ₹69,300 | 300 ₹90,000 |
| 2.01Note for item Ser No 2 a) Rates inclusive of taking down existing LED lights and fire/smoke sensors if any and refixing the same after completion of ducting work. b) The contractor shall ensure that all electrical connections and detector circuits are properly disconnected, tagged, and reconnected under the supervision of the Engineer-in-Charge. (c)Any damages caused to LED lights, detectors, or associated wiring during dismantling, handling, or refixing shall be repaired or replaced by the contractor at no extra cost to the Department. | |||||||||||||
| 3.00 | S&F nitrile rubber insulation (closed-cell type) of 19 mm thickness in one layer, fixed on duct/piping surface using approved adhesive compound, sealing all joints with weather-proof self-adhesive tape, complete including surface cleaning, adhesive, tape, labour, and scaffolding, all as specified and directed by Engineer-in-Charge. | 350 | Sqm | 1,300 ₹4,55,000 | 1,200 ₹4,20,000 | 445 ₹1,55,750 Lowest | 650 ₹2,27,500 | 1,250 ₹4,37,500 | 800 ₹2,80,000 | 1,100 ₹3,85,000 | 1,200 ₹4,20,000 | 1,260 ₹4,41,000 | 1,200 ₹4,20,000 |
| 4.00 | S&F in repairs wire netting of G.I. wire 24 gauge with 12 mm mesh size fixed with tinned tacks/staples over entire duct insulation with 50 mm overlap for preventing rat bites, complete all as specified and directed by Engineer-in-Charge. | 350 | Sqm | 320 ₹1,12,000 | 320 ₹1,12,000 | 155 ₹54,250 | 95 ₹33,250 Lowest | 250 ₹87,500 | 180 ₹63,000 | 225 ₹78,750 | 350 ₹1,22,500 | 215 ₹75,250 | 320 ₹1,12,000 |
| 5.00 | Supply and Fix in repairs of MS - CRC 18 gauge, powder coated square perforated suction/fresh air supply diffuser grills of outer size 450 × 450 mm and collar 280 mm fixed to duct for proper supply to the room and suction of air from the same complete all as specified and directed by Engr-in-Charge. | 120 | Each | 2,600 ₹3,12,000 | 2,600 ₹3,12,000 | 3,020 ₹3,62,400 | 1,550 ₹1,86,000 Lowest | 2,650 ₹3,18,000 | 2,200 ₹2,64,000 | 2,750 ₹3,30,000 | 2,600 ₹3,12,000 | 2,800 ₹3,36,000 | 2,800 ₹3,36,000 |
| 6.00 | S&F in repairs of MS-CRC 18 gauge, powder coated square perforated suction/fresh air supply diffuser grills of outer size 370×370 mm with collar 180–220 mm fixed to duct for supply and return air, complete all as specified and directed by Engineer-in-Charge. | 150 | Each | 3,650 ₹5,47,500 | 2,200 ₹3,30,000 | 2,510 ₹3,76,500 | 1,400 ₹2,10,000 Lowest | 2,700 ₹4,05,000 | 1,900 ₹2,85,000 | 2,450 ₹3,67,500 | 2,500 ₹3,75,000 | 2,900 ₹4,35,000 | 2,500 ₹3,75,000 |
| 7.00 | S&F in repairs of fire damper actuator 10 Nm, 24/230 V AC, spring return type with auxiliary switch, complete as per site requirement and as directed by Engineer-in-Charge. | 6 | Each | 8,700 ₹52,200 | 8,200 ₹49,200 | 12,500 ₹75,000 | 18,500 ₹1,11,000 | 9,000 ₹54,000 | 7,500 ₹45,000 Lowest | 8,450 ₹50,700 | 8,500 ₹51,000 | 8,500 ₹51,000 | 9,000 ₹54,000 |
| 8.00 | M&L for repair to existing control panel from input 230V to output 24V including temperature sensor, wiring,including testing of fire damper system, complete all as specified and directed by Engineer-in-Charge. | 6 | Each | 2,500 ₹15,000 | 2,100 ₹12,600 | 2,750 ₹16,500 | 7,500 ₹45,000 | 2,500 ₹15,000 | 1,600 ₹9,600 Lowest | 2,092 ₹12,552 | 2,300 ₹13,800 | 2,600 ₹15,600 | 2,500 ₹15,000 |
| 9.00 | M&L for cleaning of air ducts (G.I./Aluminium) by removing dust, dirt, and microbial deposits using mechanical cleaning equipment, including air compressor, air jet nozzles, flippers, vacuum pump, and suction blower with super-fine filtration system, ensuring ducts are thoroughly cleaned and air quality verified before and after cleaning complete all as specified and directed by Engineer_in_charge.
Note : Work includes labour, machinery, tools, consumables, scaffolding, and safe disposal of collected dust, complete all as specified and directed by the Engineer-in-Charge. | 2,000 | Sqm | 260 ₹5,20,000 | 250 ₹5,00,000 | 305 ₹6,10,000 | 325 ₹6,50,000 | 250 ₹5,00,000 | 220 ₹4,40,000 Lowest | 275 ₹5,50,000 | 320 ₹6,40,000 | 325 ₹6,50,000 | 320 ₹6,40,000 |
Tender Value
₹29.5 L
EMD Value
₹59,000
Closing Date
6 Aug 2026, 6:00 pmClosed
CWE (NW) Mumbai
CWE (NW) Mumbai
REPAIR and REPLACEMENT OF DUCTS ALONGWITH ISULATION AT INHS ASVINI UNDER AGE(I) ASVINI
2026_MES_779065_1
8027/CWE (NW) MUMBAI/2026/E8
Open Tender
Civil Works
Item Rate
180 days
AGE (I) Asvini
Class D Category c (i)
7 documents required · 7 mandatory
₹500
AGE (I) ASVINI
₹59,000
Yes
11 Sept 2026
18 Jul 2026
7 Aug 2026
18 Jul 2026
6 Aug 2026
1 Aug 2026
18 Jul 2026 - 25 Jul 2026
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1 | Supply, fabrication, and erection of factory-fabricated rectangular or square duct made out of 24-gauge (0.63 mm thick) G.I. sheet conforming to IS: 277 with zinc coating not less than 120 gsm, formed to the required shape and size in L-shaped hollow profile. The work shall include all accessories such as corner pieces, flanges, gaskets, approved duct sealant, G.I. nuts, bolts, carriage bolts, hangers, supports, and all materials required for proper installation complete all as specified and directed by Engineer_in_charge. | 300 | Sqm | - | - |
| 2 | Taking down carefully the existing rectangular or square G.I. ducting of any gauge or size including all connected fittings, accessories, thermal insulation, wire mesh/net, supports, hangers, and sealing material. The work shall include cutting, dismantling, unscrewing, or unbolting joints, lowering the ducts safely from the ceiling or wall, and stacking serviceable material complete all as specified & directed by Engr-in-charge. | 300 | Sqm | - | - |
| 3 | S&F nitrile rubber insulation (closed-cell type) of 19 mm thickness in one layer, fixed on duct/piping surface using approved adhesive compound, sealing all joints with weather-proof self-adhesive tape, complete including surface cleaning, adhesive, tape, labour, and scaffolding, all as specified and directed by Engineer-in-Charge. | 350 | Sqm | - | - |
| 4 | S&F in repairs wire netting of G.I. wire 24 gauge with 12 mm mesh size fixed with tinned tacks/staples over entire duct insulation with 50 mm overlap for preventing rat bites, complete all as specified and directed by Engineer-in-Charge. | 350 | Sqm | - | - |
| 5 | Supply and Fix in repairs of MS - CRC 18 gauge, powder coated square perforated suction/fresh air supply diffuser grills of outer size 450 × 450 mm and collar 280 mm fixed to duct for proper supply to the room and suction of air from the same complete all as specified and directed by Engr-in-Charge. | 120 | Each | - | - |
| 6 | S&F in repairs of MS-CRC 18 gauge, powder coated square perforated suction/fresh air supply diffuser grills of outer size 370×370 mm with collar 180–220 mm fixed to duct for supply and return air, complete all as specified and directed by Engineer-in-Charge. | 150 | Each | - | - |
| 7 | S&F in repairs of fire damper actuator 10 Nm, 24/230 V AC, spring return type with auxiliary switch, complete as per site requirement and as directed by Engineer-in-Charge. | 6 | Each | - | - |
| 8 | M&L for repair to existing control panel from input 230V to output 24V including temperature sensor, wiring,including testing of fire damper system, complete all as specified and directed by Engineer-in-Charge. | 6 | Each | - | - |
| 9 | M&L for cleaning of air ducts (G.I./Aluminium) by removing dust, dirt, and microbial deposits using mechanical cleaning equipment, including air compressor, air jet nozzles, flippers, vacuum pump, and suction blower with super-fine filtration system, ensuring ducts are thoroughly cleaned and air quality verified before and after cleaning complete all as specified and directed by Engineer_in_charge.
Note : Work includes labour, machinery, tools, consumables, scaffolding, and safe disposal of collected dust, complete all as specified and directed by the Engineer-in-Charge. | 2,000 | Sqm | - | - |
| 10 | S&F in repairs new motorized fire damper with 150 mm frame and 30 mm flange made from 16G G.I. sheet with fusible link, conforming to existing size and specification, complete all as directed by Engineer-in-Charge. | 10 | Sqm | - | - |
stage.html
html • 0.04 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.40 MB
BOQ_872598.xls
BOQ • 2.80 MB
NIT.pdf
Tender Documents • 0.39 MB
03 Genpages.pdf
Tender Documents • 0.90 MB
04 PS ac updated.pdf
Tender Documents • 0.35 MB
05 Appndx A f.pdf
Tender Documents • 0.39 MB
06 CESC MAKES BR-EM.pdf
Tender Documents • 0.52 MB
07 PS APPX C to G Revised.pdf
Tender Documents • 0.81 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .