Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹28.9 LAccepted-AOC 0 MANPUR CHITBARAGAON CHITBARAGAON BALLIA UTTAR PRADESH 221713 | BALLIA | UTTAR PRADESH | 221713 | L1 | Accepted-AOC LOWEST BIDDER | |
| 2 | L2₹32.4 L+₹3.4 L (11.8%)Rejected-Finance | L2 | Rejected-Finance OTHER THAN LOWEST BIDDER | |
| 3 | L3₹32.5 L+₹3.5 L (12.2%)Rejected-Finance | L3 | Rejected-Finance OTHER THAN LOWEST BIDDER | |
| 4 | L4₹45.7 L+₹16.8 L (57.9%)Rejected-Finance MOHALLA KAMA KHAN WARD NO 07 HOUSE NO 88 DISTT POONCH J K | L4 | Rejected-Finance OTHER THAN LOWEST BIDDER |
Tender Value
₹38 L
EMD Value
₹76,000
Closing Date
25 Jun 2024, 6:00 pmClosed
GE 881 EWS C/o 56 APO
GE 881 EWS C/o 56 APO
PROVN OF HARD STANDING AND COVERED SHED FOR MT VEH AT LKG AND PROVN OF 38 X SECURITY LIGHTS WITH 9 METER HIGH POLES ALONG PERIMETER UNDER GE 881 EWS
2024_MES_656390_1
GE/PNH-16/2024-25
Open Tender
Civil Works
Item Rate
180 days
GE 881 EWS C/o 56 APO
AS PER TENDER DOCUMENTS
8 documents required · 8 mandatory
₹500
Yes
GE 881 EWS
₹76,000
Yes
14 Jul 2024
28 May 2024
1 Jul 2024
28 May 2024
25 Jun 2024
11 Jun 2024
Amount
Surface dressing not exc 15 cm deep including cutting bushes, shrubs etc in soft/loose soil complete all as specified and directed.
Excavation in trenches in any type of soil n. exc 1.5 m wide and n.exc 1.5m deep and getting out complete all as specified and directed.
Excavation in post holes (or similar holes) in any type of soil each n. exc 0.5 cum, getting out returning filling in and ramming earth or broken rubble mixed with earth around in layer not exceeding 25cm, watering and removing surplus spoil to distance not exceeding 50 mtr and making goog sorface complete all as specified and directed.
M&L for PCC (1:4:8) type D2 using 40mm graded stone agg as in mass filling and foundation complete all as specified and as directed.
M&L for PCC (1:3:6) type C2 using 40mm graded stone agg as in post holes complete all as specified and as directed.
M&L for brick work with sub class B bricks (Old size) straight or curved on plan exceeding 6mt mean radius built in CM(1:6) complete all as specified and as directed.
Returning filling, including spreading leveling, watering and well ramming in layer n.exc 25cm thick complete all as specified and as directed.
Removing excavated material to a distance n exc.50m and depositing where directed at a level n exc. 1.5 m above the starting point complete all as specified and as directed.
M&L for rendering 15 mm thick in cement and sand mortar 1:4 on fair faces of brick work or cement concrete surfaces including finishing the surface even and smooth without using extra cement complete all as specified and as directed.
M&L for PCC Type B-1, 1:2:4 (20 mm graded aggreagate) as in coping etc, complete all as specified and directed.
M&L for applying two coats of cement base paint on walls including preparation of new plastered or un-plastered surfaces of wall, complete all as specified and directed.
S&F structural steel work as in joist, channel, angle fixed independently without connecting plates etc (cut to ordinary lengths) confirming to Fe-290 Gde E-165 complete all as specified and as directed.
M&L for roof trusses (framed), trussed, purlins, crane gantries, rails and fastnings and heavy bracket, framing (Beam, tee, angle, channel or flat setions ) including distance pieces, cleats etc conforming to Fe-290 Gde E-165 complete all as specified and as directed.
M&L for plates (plain or chequered) channels, square cut or notched (ordinary and counter sunk) forming holes, without any attachment conforming to Fe-290 Gde E-165 all as specified and as directed.
M&L for Mild steel screw bolts (machine made) with hexagonal or square heads at one end and screwed the other, or screwed both ends, each screwed end to be fitted with washers and one hexagonal or square nut, length of bolt not exceeding 5 cm and dia of shank 5 to 10 mm complete all as specified and as directed.
M&L for Mild steel work as in hand rails, half round or other stock section or core for wooden hand -rail, straight portion drilled and countrsunk for ballusters running bars, for doors, balusters, nosing to steps including embeding in concrete and screqing etc. wind ties for roof including securing bolts, posts and struts in fencing including cuttings, tops to shapes, as directed, drilling, holes, notching for wire etc. flat iron fillets (for securing wire mesh etc.) including all necessary drilling, bolting or riveting etc. fixed in repairs, and similar work conforming to Fe-250 Gde E-165 all as specified.
M&L for preparation of new steel surface of any description n. exc 10cm width or girth and applying two coat of synthetic enamel paint over a coat of red oxide primer complete all as specifiedand directed.
M&L for hardcore of broken stone of gauge not exceeding 63 mm, deposited, spread and levelled in layers not exceedind 15 cm thick, watered and rammed to a true surfaces complete all as specified and as directed.
M&L for 100mm thick PCC (1:4:8) type D-2 using 40mm graded stone aggregate as in sub base complete all as specified and as directed.
M&L for 75mm thick PCC (1:2:4) type B-2 using 40mm graded stone aggregate as in sub base complete all as specified and as directed.
M&L for 50 mm thick cement concrete (1:3:6), type C-1 using 20mm graded stone aggregate as in floors, hard standing etc and laid in alternate bays complete and finished the even & fair and providings joints through out the thickness of plinth protection filed with mastic filling comprising one part of 01 bitumen 85/25 grade and three part of sand by weight all as specified and directed
S & F Pre painted galvalume aluminium zinc coating GI based corrugated steel sheet 0.50 mm thick of any colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws, complete all as specified and as directed.
Excavation over areas, n exc 1.5 m deep and gettting out in any type of soil, complete all as specified and as directed.
Removing excavated soil to a distance exc 50 m but not exc 250m away and depositing where directed at a level not exc 1.5 m from the starting point, complete all as specified and directed.
M&L for sand filling under floors or in foundations including watering and consolidation etc spread, levelled and rammed including watering complete all as specified and directed.
M&L for machine pressed precast concrete interlocking paver block any shape and size confirming to IS-15658-2006 of 80mm thickness M-40 Grade,laid jointed pointed with grey cement and no pigments, complete all as specified and directed by Engr-in-Charge. Note: The sample shall be got approved by GE before bulk procurement & lot shall be got tested independently by the GE.
E/M PORTION: Supply and laying cable XLPE insulated screened, PVC bedded, galvanised, steel strip or wire armoured, electric power cable, (heavy duty) 1100 volts grade, with stranded aluminium conductor of size 35 Sqmm 3.5 core complete all specified and directed.
Supply and laying cable XLPE insulated screened, PVC bedded, galvanised, steel strip or wire armoured, electric power cable, (heavy duty) 1100 volts grade, with stranded aluminium conductor of size 16 Sqmm 4 core complete all specified and directed.
Supply and erecting true vertical steel tubular poles, swaged type,410-SP-31, 9 meter long with 300x300x6mm thick MS base plate continuously welded to pole with MS sheet 2mm thick B-118 finial taper plug welded at top bolts, Nuts and screws all as specified including two coats of black bituminous paint internally throughout and externally for embedded portion and two coats of aluminium paint over a coat of red oxide primer on exposed surfaces upto 5 feet and painting strips of yellow and black from foot of pole upto 5 feet each strip of 30 cm height, complete all as specified. (Note : Excavation, earth work and PCC in foundation of poles, coping etc shall be measured and paid separately under respective items of work).
S&F LED street light fitting 45 watt LED, IP-65 protection, single peice pressure die cast aluminium housing high grade powder coated finish with heat resistant toughned clear glass cover for lamp including suitable bracket & clamp as specified & directed by Engr-in-Charge.
S&F FRP pole mounting box weather proof type of size 155mm x 155mm x 100mm with three terminal and one 6 Amps MCB mounted inside complete all as specified and direcyed by EIC. Make: Sintex/National/Standard.
M&L for sand cushioning to under ground cable providing with a layer of and 08 cm thick before laying of cable and 15 cm after laying of cable in trenches, hand punning complete all as specified and directed by Engr-in-charge (Note : punning thickness of 18 cm will be measured for payment)
M&L for laying of well burnt bricks locally avaiblable, laid flat for protection of under ground cable complete all as specified and directed at site.
S&F 40mm bore galvanised steel water tubing, light grade including all fittings laid in trenches / fixed to pole / along wall / floor etc for protection of cable/strip incl fixing to pole with M.S. clamp, nuts, bolts etc complete all as specified and as directed.
Supply & fix PVC insulated, 1100 volts grade, stranded copper conductor cable 1.5 Sqmm, 3 core, connecting from Street light junction box to light fittings complete all as specified and directed.
S&F PVC pipes/counduit 15 mm dia and fixed with the pole by clamping / saddling for protection of connecting wires, connection from junction box to light fittings, complete all as specified and as directed.
M&L for earthing complete with galvanized steel earth plate electrode size 600x600x6mm thick buried directly in ground vertically in a pit of depth not less than 2.25 mtr below ground levels with top edge of the earth plate not less than 1.5 mtr below normal ground level surrounded from all sides by mixture of charcoal and common salt and electrode connected to and including galvanized iron strip 25X4 mm earth lead by means of bolts, nuts, check nuts and washers of galvanized steel including GI pipe light grade of size of 40 mm dia for protection and GI pipe medium grade 20mm dia bore for watering funnel with wire mesh. CI cover with frame, PCC chamber pit with PCC 1:3:6 type C-2 excavation and earth work all as shown inall as shown in electrical plate No. 5 of SSR-1991 Part I or plate No 3 of SSR Pt I of 2009 connected to earthing test point all as specified or indicated including testing on completion. NOTE 1. The unit rate includes for GI earth strip 25x4 mm from top of earth plate up to 7.5 meter.
Design, supplying, installing, testing and commissioning of LT outdoor double door type Feeder Pillar Box factory fabricated cubical kiosk type weather vermin proof with locking arrangement and made out of MS sheet 3.15 mm thick suitable size of channel for base complete with 200 Amps rated aluminum bus bar 32 mm thick chamber and cabinet for housing mounting switch disconnection fuse unit metering eqpt prewired with suitable size of copper conductor and duly painted with one coat of red oxide paint and two coats of synthetic enamel paint power coating mounted on PCC (1:4:8) platform commissioning washer chamber and panel board fixing an angle iron frame which is made out of 40 x 40 x 6 mm thick angle iron duly marked the incoming outgoing controls and comprising with the following:- (a) MCCB 63 Amps capacity 25 KA 4 Pole, 415 -01 Nos (incoming) (b) Out going-MCB TPN 63 Amp- 2 Nos , (c) Amp meter , Volt meter and indicator set (RYB). Note: Workable space shoud be provided for operating.
M/S KHAN ENTERPRISES
VIKAS ENTERPRISES
JAMWAL CONSTRUCTION CO
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .