Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹18.3 LAccepted-AOC | ₹18.3 L | L1 | Accepted-AOC Lowest Bidder |
| 2 | L2₹22.5 L+₹4.2 L (22.9%)Rejected-Finance N A | NA | NA | 121004 | ₹22.5 L+₹4.2 L (22.9%) | L2 | Rejected-Finance Not Lowest |
| 3 | L3₹23.7 L+₹5.5 L (29.8%)Rejected-Finance C 187 NIRMAN VIHAR DELHI 92 | ₹23.7 L+₹5.5 L (29.8%) | L3 | Rejected-Finance Not Lowest |
| 4 | L4₹23.9 L+₹5.6 L (30.8%)Rejected-Finance | ₹23.9 L+₹5.6 L (30.8%) | L4 | Rejected-Finance Not Lowest |
| 5 | L5₹24.8 L+₹6.5 L (35.6%)Rejected-Finance | ₹24.8 L+₹6.5 L (35.6%) | L5 | Rejected-Finance Not Lowest |
Tender Value
₹24.3 L
EMD Value
₹50,000
Closing Date
12 Sept 2024, 6:00 pmClosed
Garrison Engineer Gwalior
Garrison Engineer Gwalior Morar Cantt
8932/GWL/E8 PROVN OF 01 X VOLTAGE STABILIZER AT NCC OTA, PROVN OF 01 X GENERATOR SET FOR BLDG NO P-83 AND PROVN OF LIGHTNING CONDUCTOR FOR NEWLY CONSTRUCTED BLDG NEAR P-205 UNDER GE GWALIOR
2024_MES_641334_3
8932/GWL/E8
Open Tender
Electrical and Maintenance Works
Works
180 days
Garrison Engineer Gwalior
Please refer tender documents
9 documents required · 9 mandatory
₹500
Garrison Engineer Gwalior
₹50,000
Yes
18 Oct 2024
18 Jul 2024
14 Sept 2024
18 Jul 2024
12 Sept 2024
2 Aug 2024
Amount
Supply, install, testing and commissioning of Servo controlled voltage stabilizer 200KVA, (Confirming to BIS 9815: Part : 1994) Three phase, 50 Hz, Naturally Oil cooled, indoor, unbalanced type, copper wound, metallic body duly power coated with lifting Hooks two nos, digital display type, relay free smooth and silent operation with 1st filling of Transformer oil up to level having following specification :- a) Input voltage 340V-480V, (b) Output voltage stabilized at any designed/ desired voltage 415V + -1% (c) Rated frequency 50 Hz (d) No distortion in wave form (e) Response time not to exceed 20 mile seconds ( f) Sensitivity (+/-) 1% (g) Rate of correction 8 Volt/ second for single phase and 13V/seconds for phase to phase (h) Efficiency more than 95% (i)Type of load: three phase, unbalanced type (j) Digital display voltmeter/ Ammeter
M&L for Earthing with G I earth plate electrode of size 60 cm x 60 cm x 6 mm thick burried directly in ground (earth pit not less than 2.25 metres deep below normal ground level) with top edge of plate not less than 1.5 metre below normal ground level connected to G I strip of size 32x6mm as earthing lead by means of bolts, nuts, check nuts and washers of galvanised iron or steel all as shown in electrical plate No 3 of MES Schedule Part-I connecting to earthing point with and including 40 mm bore light grade G.I. protection pipe for earthing lead, PCC 1:3:6 type C1 using 20mm graded stone aggregate for earthing pit with RCC 40 mm thick cover in 1:2:4 type B-1 using 20mm graded stone aggregate reinforced with 8 mm dia TMT bars 4 Nos both ways with lifting hook made out of 6 mm dia round bar, watering pipe 20 mm bore medium grade with funnel and wire mesh, common salt and charcoal filling, including necessary excavation and earth work and testing on completion complete all as specified and directed
Supply, laying and testing cable XLPE Insulated, screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 185 Sqmm 3.5 core complete all as specified and directed.
Excavating in trenches not exceeding 1.5 mtr wide and not exceeding 1.5 mtr deep for foundation etc for laying of cables, erection of poles, struts/stays etc not exceeding 10 sqm in soft/loose soil complete all as specified and directed.
Returning, filling in, including, spreading, leveling, watering and well ramming in layers n.exc. 25 cm thick each layer in soils complete all as specified and directed.
Removing excavated soil n. exc 50 m and depositing where directed at a level n.exc. 1.5 mtr above the starting point complete all as specified and directed.
M&L for river sand, screened dry for filling in the trenches below and around the UG cable for cushioning of cable including punning down complete all as specified and directed.
M & L for Bricks common burnt clay sub class 'B' laid dry in cable protection of size 230 x 115 x 75 mm complete all as specified and directed.
S&F cable end joint kits indoor/outdoor type for LT cable of size 185 sqmm, XLPE armoured cable 3.5 core complete all as specified and directed.
Supply and fixing LED Solar street light fitting 36 Watt including galvanized steel pole in built,lithium ion battery, solar panel, charge controller with dusk down sensor complete all as specified and directed. (Excavation & earth work shall be measured separately)
M&L for cement concrete 1:3:6, type C-1 using 20 mm graded crushed stone aggregate for pedestal of poles/coping including necessary form work, fair finished to the exposed surface using extra cement complete all as specified and directed.
S&F for Earth continuity conductor or main earthing lead galvanized M S strip of size 32 x 6 mm fixed to wall on batten or recess or chases or buried in ground or drawn in conduit/pipe of required dia or fixed to poles or any other indicated using complete all as specified and directed.
Supply & fix for aluminium strip of size 25mm x 3mm complete with saddles and fixing screws for fitting the strip complete all as specified and directed.
Supply & fix single pointed air termination aluminium rod 12mm dia, 300 mm long complete all as specified and directed.
M&L for lightening conductor assembly made out of GI pipe light grade of size 40 mm bore along with welded flange, fixed on the roof with drilling/making hole and provide 2 Nos of rubber washer 6mm thick of suitable size and connect to air termination & connector for earth strip duly fixed with necessary nuts bolts & washers in PCC 1:3:6 type C1 using 20mm graded stone aggregate of size 20cm x 20 cm x20 cm complete all as specified and directed. Note :- G I pipe 40mm (1 RM for each), PCC & air temination shall be measured & paid separately under relevant items.
M&L for G I pipe 40mm dia Medium grade for Protection of GI Strip and for air termination point complete all as specified and directed.
M&L for Test point terminal block made of gun metal or phosphorus bronze of size 75x75x25mm drilled and screwed including 3 nos. 8mm dia 25mm long hexagonal head screw complete all as specified and directed.
Supply & Fixing of epoxy insulator of required size with two nos hole each on both end for fixing properly with fastner, nuts & bolts on wall & roof of buildings for separated earthing strip from building complete all as specified and directed.
Material & Labour for cutting of Roads/PCC/RCC floors and filling with PCC 1: 3: 6 type C1 (using 20mm graded crushed trap stone aggregate) & grouting in cement mortar 1:4 for making good road cutting complete all as specified and directed. Note : Excavation and removal should be measured and paid separately under appropriated items
Excavation in tenches not exceeding 1.5m wide and not exc 1.5m depth and getting out in hard/dense soil complete all as specified and directed.
Supply and installation of silent Diesel Engine driven generating set 415 volts, 3 phase 4 wire outdoor type with acoustic enclosure as per IS 7888, engine as per IS:10001/10002 and Alternator as per IS: 4722 complete with automatic electronic governor, relay panel and switch gears for automatic starting on main failure, control panel having meter and sound proof canopy as per CPCB IV+ Norms and foundation etc of capacity upto 58.5 KVA Along with remote monitor system having following facility without any cost online detail of DG parameter on mobile/Laptop Desktop :- 1. Phase Voltage 2. Current 3. Frequency 4. Power Factor 5. Genset KVA, KW, KWH, KVAR, 6. Canopy Temp. 7. Lube oil pressure 8. Engine temperature 9. RPM 10. Run Hours 11. Number of starts 12. Fuel level 13. Auto Manual stop 14. Battery charging condition AMF feature complete all as specified and directed.
Supply, laying and testing of cable XLPE insulated, armoured, heavy duty, electric LT UG cable with multi stranded aluminium conductor, 1100 Volts of size 50 Sqmm 3.5 Core complete all as specified and directed.
S&F in renewal Cable joining kit for LT cable for outdoor termination heat shrink type joint complete with joining material and accessories suitable for 3.5 core XLPE armoured aluminium conductor cable of size 25 sqmm to 50 sqmm complete all as specified and directed.
M&L for PCC foundation with PCC 1:2:4 type B-1 using 20mm graded stone aggregate and necessary Brick work in CM 1:4 for DG set with suitable size of Generator base of hard core, moorum filling inside the foundation and grouting with suitable size/Nos Nut bolts & all electrical connections, all as required at site complete all as specified and directed. Note:- Quoated rate is deemed to be included the PCC foundation work, Brick Work, anchoring Nut bolts, all electrical connections complete all as specified and directed.
M&L for PCC 1:4:8 type D2 using 40 mm graded stone aggregate as in foundation filling / mass concrete complete all as specified and directed.
M&L for Moorum red bajri filling in floor or paving laid in layers n.exc 15cm thick each layer spread levelled and rammed including watering complete all as specified and directed.
M&L for PCC 1:2:4 type B1 using 20 mm graded stone aggregate as as in sub base to floor, finished even and rough complete all as specified and directed.
Material and Labour for precast cement concrete rubber moulded coloured interlocking paver blocks/tiles, 60mm thick of grade M-35, machine made, 1st quality, of any shape or shape and design as approved, with colour pigment, laid over and cusion fixed as in floors/paths/pavings etc, complete all as specified and directed. Note : Sand cushion will be measured and paid in relevant item.
M&L for sand filling under floors or in foundations including watering and consolidation complete all as specified and directed.
M&L for factory made machine pressed kerb stone of M-25 grade cement concrete in position to required line, level & curvature, jointed in cement mortar 1:3, including making joints, with or without grooves (thickness of joint s except at sharp curves shall not more than 5mm), including making drainage opening wherever required complete all as specified and directed.
M&L for Brick work with sub class B bricks straight or curved on plan exc. 6m mean radius built in cement mortar 1:6 complete all as specified and directed.
M&L for rendering 15 mm thick cement mortar 1:6 on brick or concrete surfaces furnished even and smooth without using extra cement complete all as specified and directed.
M&L for preparation of the newly plastered wall surfaces & applying 3 coats of white wash complete all as specified and directed.
M&L for steel work in tubular trusses including special shaped washer etc compete using ERW or induction butt welded tubes confirming to IS 1161-1979 grade St 240 complete all as specified and directed.
S&F for framed work such as grills gratings, etc, with ends of bars shouldered and or riveted , or forged into spikes, framed guard bars, barred iron doors, ladders, framed balusters, walk ways, railings, framework of water tanks and similar work conforming to Fe 290 E-165 complete all as specified and directed.
S&F for rolled steel section as in main and cross beams, hip and jack rafters, purlins where connected to common rafters and running rails and guides for sliding doors fixed with angle cleats or other connecting plates confirming to Fe-290 (Gde E-165) complete all as specified and directed
S&F of Mild steel, plain, black sheet 0.63mm thick in wall cladding, steel gates and similar works, cut to size, holes punched, including round headed screws, clout nails or rivets and fixed to wood or steel framing with plain 40 mm lap joints with riveted or welded seams, including bending or turning up, mitre angles as required complete all as specified and directed.
S&F of Pre painted galvalume sheet 0.50 mm thick having aluminum zinc coating 150 gsm/ sqm trapezoidal profile steel sheet any colour having tensile strength of 550 Mpa as in Roof covering /cladding to wall fixed with self tapping screws complete all as specified and directed.
Excavating in posts holes (or similar holes) in hard/dense soil each n.exc 0.50 cum getting out, returning, filling in and ramming earth or broken rubble mixed with earth around, in layers n.exc 25cm watering, and removing surplus soil to a distance n.exc 50m and making good surface complete all as specified and directed.
M&L for PCC 1:3:6 type C2 using 40 mm graded stone aggregate as in foundation filling/mass concrete complete all as specified and directed.
M&L for hard core of broken stone of gauge not exceeding 63 mm, deposited, spread & levelled in layers not exceeding 15 cm thick watered and rammed to a true surfaces complete all as specified and directed.
M&L for PCC 1:3:6 type C2 using 40 mm graded stone aggregate as in 50mm thick plinth protection, finishing the surface even and smooth without using extra cement including forming and filling expension joints 50mm deep x 10mm wide filled with sealing compound grade A complete all as specified and directed.
M&L for preperation of new steel surfaces exceeding 10 cm width or girth and applying two coats of synthetic enamelled paint over a coat of red oxide primer complete all as specified and directed.
M&L for preperation of new steel surfaces not exceeding 10 cm width or girth and applying two coats of synthetic enamelled paint over a coat of red oxide primer complete all as specified and directed.
M & L for rails, half round or other stock section or core for wooden hand rail straight protion, drilled and counter sunk for balusters running bars, for doors, balusters, nosing to steps including embedding in PCC 1:2:4 type B1 (using 20mm graded stone aggregate) and screwing etc, wind tiles for roof including securing bolts posts and struts in fencing post including cutting tops to shape as directed, drilling holes, notching for wire, etc flat iron melts (for securing wire mesh etc, including all necessary drilling, bolting or riverting etc and similar work confirming to Fe 290 Gde E 165 complete all as specified and directed.
M/s Sree Baba Traders (BID ID -3083850)
M/S KAPIL CONSTRUCTION CO (BID ID -3084418)
M/s Sagar Construction (BID ID -3081811)
Lall Electronics (BID ID -3084088)
M/s Anupam Construction Co. (BID ID -3084378)
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .