| 1 | L-1Rejected-Finance A 14 INDUSTRIAL HOUSE INDERPURI NEW DELHI 1100012 | NEW DELHI | NEW DELHI | DELHI | 110012 | L-1 | Rejected-Finance Tender Rejected due to administrative Ground |
| 2 | L-2Rejected-Finance 46 LOWER GROUND FLOOR CHARMWOOD PLAZA EROS GARDEN FARIDABAD HARYANA 121009 | FARIDABAD | FARIDABAD | HARYANA | 121009 | L-2 | Rejected-Finance Tender Rejected due to administrative Ground |
Tender Value
Refer Docs
EMD Value
₹2.3 L
Closing Date
10 Mar 2022, 2:00 pmClosed
Executive Engineer, W.S. Mech. Division, Rewari
Executive Engineer, W.S. Mech. Division, Rewari
Supply, Erection and commissioning of 03 No. 10 Cs an 2 No. 5 Cs AFVT Pumps having lift 25-30 feet, alongwith suitable motors and 1 No. MCC /LT panel of 800 Amp and Starter of various capacity at left side JLN 14.700 Km Permanent New Flood Pump Hous
2022_HRY_208289_9
291/6-A dated 14.02.2022
Open Tender
Pumps/Motors
Works
180 days
Executive Engineer, W.S. Mech. Division
Please refer Tender documents.
3 documents required · 3 mandatory
₹15,000
Yes
₹2.3 L
Yes
Executive Engineer, W.S. Mech. Division, Rewari
7 Dec 2022
18 Feb 2022
10 Mar 2022
18 Feb 2022
10 Mar 2022
18 Feb 2022
22 Feb 2022
Amount
Supply, erection and commissioning of 10Cs. V.T. Axial flow Pump having lift 25-30 ft, around 980 RPM, Including MS delivery of 8 mm thickness (approx length - 70 feet each) & bend complete in all respect (having all guiding bushes of Gun Metal) as per site requirement & specification approved by technical committee (Annexure - A).
Supply, erection and commissioning of induction motor of 60 HP suitable for 10 Cs VT axial flow pump (mentioned at Sr no. 01), 45 KW, 980 RPM, 415V, 3 phase, 50 Hz bearing SKF /FAG, IE-2 as per specifications and site requirements (Annexure - B).
Supply, erection and commissioning of 05Cs. V.T. Axial flow Pump having lift 25-30 ft, 1440 RPM Including MS delivery of 8 mm thickness (approx length - 70 feet each) & bend complete in all respect (having all guiding bushes of Gun Metal) as per site requirement & specification approved by technical committee (Annexure - A).
Supply, erection and commissioning of induction motor of 40 HP, 1440 RPM, Hollow shaft suitable for 05 Cs VT axial flow pump (mentioned at Sr no. 03), 30 KW, 415V, 3 phase, 50 Hz bearing SKF /FAG, IE-2 as per specifications and site requirements (Annexure - B).
Supply, errection and commissioning of LT cable 3.5 core - 300 Sq mm Aluminium Conductor, XLPE insulated, Armored cable from Transformer to Motor Control Centre.
Supply, errection and commissioning of LT cable 3 core - 120 Sq mm Aluminium Conductor, XLPE insulated, Armored cable from Starter to Motor.
Providing and fixing of chemical earthing by digging 200 mm bore, 10 ft depth complete with copper electrode, copper strip for MCC panel complete in all respect as per site requirement
Supply of 20HP fully Automatic Star Delta Starter 415 V, 50 Hz with air breaker power contractors of 40A/40A/40A for 20HP motor with meter, relays, indicators complete in all respect with degree of protection IP-55 and with canopy including connection and small item like thimble, nut bolts, lugs etc with stand of MS angle 50x50x6 mm of 1 feet height from floor level and with allied accessories as per makes and specification.(as per Annexure-C)
Supply of 30HP fully Automatic Star Delta Starter 415 V, 50 Hz with air breaker power contractors of 50A/50A/50A for 30HP motor with meter, relays, indicators complete in all respect with degree of protection IP-55 and with canopy including connection and small item like thimble, nut bolts, lugs etc with stand of MS angle 50x50x6 mm of 1 feet height from floor level and with allied accessories as per makes and specification.(as per Annexure-C)
Make of Pumps- Kirloskar, Wilo, Flowmore, WPIL, Xylem, GITA & Sintech. Make of Motors - LV Motor- Marathon, ABB, Kirloskar Electric, Siemans, Crompton, Jyoti, BCH, Bharat Bijli. Make of Panels - LV Panel- Siemans, ABB, L&T, Schneider, G.E. C&S, Havells, BCH, Legrand & AE. Terms & Conditions:- 1. The tender rate will be inclusive all taxes as applicable including GST. 2. The tender rate will be for F.O.R. destination and inclusive of all incidental charges, enroute & at destination. Nothing extra shall be paid separately. 3. WWC@1% will be deducted from the each bill of the agency. 4. The rate should be inclusive carriage, fitting and allied parts complete in all respect with left over items (if any) as per site requirement. 5. Goods which to be used / supplied should be as per sample and conforming to the site condition & also conforming to I.S. Specification. 6. Department will not be responsible for non submission of BOQ / Bid Document online by due date, due to any fault of internet/ E-tendering. 7. Third Party Testing by T.P.I.A. will be carried out in the presence of departmental representative at the manufacturer premises and cost of the same will be borne by the successful agency. 8. Completion period – completion period is 6 months. 9. Agreement for maintenance / service of the work will be drawn with L-1 Agency on the terms and conditions given in SLA issued by C.E./LCU, I&WR Department Haryana Panchkula letter No. 1089-91/NABARD/2020 dated 16.09.2020 (copy attached). Agreement shall be for five years or 10000:00 Hrs. of working of electro mechanic equipments from the date of commencement of the agreement. 10. Payment schedule, as per bidding documents & 70% payment be made as per pro-rata basis. 11. Payment shall be made on finished goods and not on casting only. 12. The material will be supplied as per drawing and newly approved technical specifications laid down in tender documents & subsequent submission by bidder in this regard. 13. Successful agency will submit drawing of the work within week period from the date of approval of rate by competent authority. 14. HT bolt to be used instead of SS bolt. 15. Authorization from OEM (Pump, Motor & Panel) be attached if tenderer is not a manufacturer. 16. Panels be manufactured by original manufacturer either by approved brands themselves or their authorized original equipment manufacturers under their brand name. The inspection is also allowed at their channels partner’s work with the condition that all drawings / test certificates shall be from the original equipment manufacturer. System house of approved brand are not acceptable and rating IP 54. 17. Each page of bid book will be signed by the tenderer as a token of acceptance of terms and conditions. 18. Bidders may visit to the sites before quoting the tender rates.
MOHINI ELECTRICALS LTD.
stage.html
html • 0.03 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .