CHIEF ENGINEER JAIPUR ZONE JAIPUR
HEAD QUARTER CHIEF ENGINEER JAIPUR ZONE JAIPUR
ADDN/ALTN AND REPAIR TO TOILET, BATHROOM, KITCHEN OF MAP (JCOs/OR) (PHASE-I OF PHASE-III) AT ALWAR MIL STN
2024_MES_666894_2
80898
Open Tender
Civil Works
Item Rate
365 days
GE Alwar
Please refer to tender documents
7 documents required · 7 mandatory
₹2,000
GE Alwar
₹4.1 L
Yes
HEAD QUARTER CHIEF ENGINEER JAIPUR ZONE JAIPUR
9 Nov 2024
4 Sept 2024
18 Oct 2024
4 Sept 2024
16 Oct 2024
3 Oct 2024
12 Sept 2024
Amount
Demolition of RCC work (reinforced) as Roofs, floors (other than ground floors), beams staircases, landing, chajjas, and similar suspended work including removal of debris’s from site and cleaning the premises etc complete all as specified and directed. Note:- (i) Cost of Remove salvage from the MOD land shall be included in the quoted rate by the contractor. Nothing extra shall be paid at later stage on this account. stage. (ii) Cost of executing the work at any height at (G+2) building shall be included in the quoted rate by the contractor. Nothing extra shall be paid at later stage on this account.
Taking down cement plaster any description on brick or stone walls, etc. raking out joints, hacking for key, scrubbing down with water, etc and removing all the material from the site etc complete all as specified and directed. Note : (i) Contractor shall be arrange scaffolding and other tools/plants for taking down of plaster and safety equipments at G+2 Bldgs. The cost of arrangement of scaffolding and other material shall be included in the quoted rate by the contractor. Nothing extra shall be paid at later stage on this account. (ii) The salvage material received from demolition shall be removed from site due out side the MOD land. The quoted rates are deemed to be included the cost of removal. Nothing is extra paid on this account.
Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing), removing serviceable tiles to store and rubbish off the premises etc complete all as specified and directed. Note : (i) The salvage material received from demolition shall be removed from site due out side the MOD land. The quoted rates are deemed to be included the cost of removal. Nothing is extra paid on this account.
Demolition of Stone slabs and tiles of any description or thickness in floors, aprons etc, laid, bedded and pointed in any mortar and removing all the demolished material out of defence land etc complete all as specified and directed. Note: Rate of removing of demolished material from MOD land shall be included in the quoted rate by the contractor. Nothing extra shall be paid at later stage on this account.
Demolition of cement concrete (un-reinforced) in ground floors and pavings n exc 15 cm thickness (below or above ground level) including removing the demolished material out side of defence land etc complete all as specified and directed. Note: Rate of removing of demolished material from MOD land shall be included in the quoted rate by the contractor. Nothing extra shall be paid at later stage on this account.
Material and labour for 25 mm thick Cement concrete type B-0, 1:2:4 (12.5 mm graded stone aggregate) as under floor tiles finished the surface even and rough etc complete all as specified and directed.
M&L in repair for coloured non skid ceramic tiles 7 to 8mm thick area of each tile exceeding 0.06 Sqm but not exceeding 0.11 Sqm as in floors etc., laid over and including 15 mm thick screed bed of cement mortar 1:6 set and jointed in neat cement slurry and pointed in white or coloured cement to match etc complete all as specified and directed.
Material and labour for coloured joint free Non - skid Ceramic tiles 7 to 8 mm thick (square/rectangular) area of each tile exceeding 0.11 sqm but not exceeding 0.18 sqm, over and including roughening existing surface in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match and including 15 mm thick screed bed of cement mortar 1:6 set and jointed in neat cement slurry and pointed in white or coloured cement to match etc complete all as specified and directed. Note : The cost of cutting of tiles in any shape and size shall be included in the quoted rate by the contractor. Nothing extra shall be paid at later stage on this account.
All as per item No 8 above but in skirting over and including 10 mm thick plaster in cement mortar 1:4 etc complete all as specified and directed. Note : The cost of cutting of tiles in any shape and size shall be included in the quoted rate by the contractor. Nothing extra shall be paid at later stage on this account.
M&L Glazed ceramic coloured tiles(Ist quality) in vertical surface 450x300 x 7 mm thick joint free set and jointed in neat cement slurry and pointed in white or colour cement to match over and including 10mm thick backing coat in Cement & Sand Mortar 1:4, etc complete all as specified and directed. Note : The cost of cutting of tiles in any shape and size shall be included in the quoted rate by the contractor. Nothing extra shall be paid at later stage on this account.
Taking up or down 15mm dia bore pipe PVC tubing and connections, including cleaning for re-fixing or removal to store etc complete all as specified and directed.
Taking up or down 20mm dia bore pipe PVC tubing and connections, including cleaning for re-fixing or removal to store etc complete all as specified and directed.
S&F 15mm bore steel water tubing medium grade galvanised with all fittings and fixed to wall and ceiling or laid in floor including Supporting Clamping if required - triple Pipe of dia 15mm down take pipe line fixing done with Clamping System consists of Mono Bracket + U Bolt R/M system running vertically with wall distance 3"etc complete all as specified and directed. Note :- Pipe Support Clamping Unit to be fixed at every metre distance in the duct as specified in the TD No. : CE Jaipur Zone - Jaipur; TD/2022/01.
S&F 20mm bore steel water tubing medium grade galvanised with all fittings and fixed to wall and ceiling or laid in floor including Supporting Clamping - triple Pipe of dia 3/4" (20 mm) down take pipe line fixing done with Clamping System consists of Mono Bracket + U Bolt R/M system running vertically with wall distance 3"etc complete all as specified and directed. Note :- Pipe Support Clamping Unit to be fixed at every metre distance in the duct as specified in the TD No. : CE Jaipur Zone - Jaipur; TD/2022/01.
S&F in repairs, vitreous China squatting pan, 'Orissa' pattern, size 580 x 440 mm, white with integral foot rest and 'P' or 'S' trap, including provision of Cement concrete bedding, connection to trap set and joint between flushing pipe etc complete including making good to disturbed surfaces of floor to match etc complete all as specified and directed. Note : The rate of trap set shall be included in the quoted rate by the contractor. Nothing extra shall be paid at later stage on this account.
S&F in repair 10 litres capacity PVC valveless, syphonic action type, flushing cistern, low level, white with inlet ball valve, float, handle including brackets and Flush Pipe of polyethylene of low or high density or PVC 32 mm dia for low level cisterns and brackets after taking down old cistern etc complete all as specified and directed.
S&F in repair Stop valves/angle cock 15mm dia bore of pipe cast copper alloy, fancy type, chromium plated, screwed down, high pressure, with crutch or butter fly handle, screwed both ends for iron pipe or for unions etc complete all as specified and directed.
S&F in repairs 15mm dia/bore wall mixer chromium plated (3 in -1) with arrangement for overhead shower with 220 mm max long bend pipe etc complete all as specified and directed.
S&F in repairs 15mm dia bore bib taps, cast copper alloy, fancy type, chromium plated, with crutch or butter fly handle screwed down, screwed for iron pipe or for brass ferrule etc complete all as specified and directed.
S&F in repair PVC connection 15mm size with PTMT nuts of length 450mm etc complete all as specified and directed.
S&F in repairs Brass chromium plated shower rose 125mm size fixed to 15mm bore pipe with or without swivel joints including fixing to steel pipe etc complete all as specified and directed.
S&F in repair PTMT Towel rail 600mm long of PTMT fixed with and including chromium plated brass screws and wooden/plastic cleats (minimum weight 170gms) fixed to wall etc complete all as specified and directed.
S&F in repairs sinks with drainage board made of stainless steel 1mm thick for kitchen or laboratory with waste coupling and plug washers including bedding in cement mortar to dwarf wall or including waste pipe fixing cantilever brackets and connecting union to pipe overall size 915mm x 460mm and bowl size 410mm x 330mm x160mm etc complete all as specified and directed.
S&F in repairs stainless steel Kitchen plate rack of overall minimum size 900mm x 750mm and 230mm deep, with partitions for small/large plates etc made out of stainless steel 24 Gauge, fixed with rawl plug and CP steel screws etc complete all as specified and directed. Note : Weight of rack shall not be less than 4.50 Kg.
S&F 75mm bore PVC (SWR) pipes single socketed in any length with rubber ring joints laid in trenches or in floors etc complete all as specified and directed.
S&F 110mm bore PVC (SWR) pipes single socketed in any length with rubber ring joints laid in trenches or in floors etc complete all as specified and directed.
S&F 75mm bore PVC (SWR) pipes, single socketed in any length fixed to wall etc complete all as specified and directed.
S&F 110mm bore PVC (SWR) pipes, single socketed in any length fixed to wall etc complete all as specified and directed.
S&F in repair 75mm outer dia PVC (SWR) floor trap, plain with grating including joining with solvent cement etc complete all as specified and directed.
S&F in repair 75mm bore PVC (SWR) bend of any radius etc complete all as specified and directed.
S&F in repair 75mm bore PVC (SWR) bend of any radius with access door etc complete all as specified and directed.
S&F in repair 110mm bore PVC (SWR) bend of any radius etc complete all as specified and directed.
S&F in repair 110mm bore PVC (SWR) bend 110 mm bore of any radius with access door etc complete all as specified and directed.
S&F in repair 75mm bore PVC (SWR) branch piece, single (single Y) equal or unequal with access door etc complete all as specified and directed.
S&F in repair 110mm bore PVC (SWR) branch piece (Single T) equal or unequal with access door etc complete all as specified and directed.
S&F in repair 75mm bore PVC (SWR) branch piece (Single T) equal or unequal etc complete all as specified and directed.
S&F in repair 75mm bore PVC (SWR) branch piece (Double T) equal or unequal with access door etc complete all as specified and directed.
S&F in repair 110 bore PVC (SWR) vent cowl etc complete all as specified and directed.
S&F for Pipe Supporting Clamping - Single Pipe of dia 3" (75 mm) down take pipe fixing done with Clamping System consists of Profile Bracket + Continuous Slotted C Channel + U Bolt R/M System running vertically with wall distance 3": Pipe Support Clamping made of 1. Profile Bracket having Wall Distance 3" made of Low Carbon Hot Roll Gauge Corrected (HRGC) Steel (IS 1079 DD); material size 32 mm x 3 mm with ribs and notch are Hot Dip Galvanzied + Zn Al Flake coated having Salt Spray Test (Test method - ASTM B-117-2019) result above 2000 hrs with SS304 Hex Flange Bolt with Serration 5/16 x 3/4 (A/F 13mm) as per DIN 6921and SS304 Hex Flange Nut BSW 5/16 x 18 x 8 x 13 with Serration as per DIN 6923. 2. Continuous Slotted "C" Channel with ribs to be used of size 10" made of Low Carbon Hot Roll Gauge Corrected (HRGC) steel (IS 1079 DD) are Hot Dip Galvanzied + Zn Al Flake coated with material thickness of 3mm. 3. U bolt R/M are made of low carbon mild steel with Rod diameter 7 mm approx.; Zn Al Flake coated with noise absorbing semi transparent ribbed silicon rubber sleeve; with Hex Flange Nut BSW 5/16 x 18 x 8 x 13 with Serration set as per DIN 6923 - Zn Al Flake coated. Hotdip Galvanizing: As per IS 2629 (1985) - 610 grams/m2 (> 85 microns). Material Grade : IS 1079 DD used as per MTC confirms to EN 10204 3.1. Material Qty. for one unit : 1. Profile Bracket Wall distance 3" - 2 Nos. 2. Continuous Slotted C Channel of Size 10" - 1 No.; 3. U Bolt R/M for 3" (75 mm) CI or PVC Pipe Dia. 1 No.; and 4. Justi Khilla 2 1/2" Zn coated - 4 nos. Fixing Details: Pipe Support Clamping Unit to be fixed at every metre distance in the duct as specified in the Technical Drawing No. : CE Jaipur Zone - Jaipur; TD/2022/01.
S & F for Pipe Supporting Clamping - Single Pipe of dia 4" (110 mm) down take pipe fixing done with Clamping System consists of Profile Bracket + Continuous Slotted C Channel + U Bolt R/M System running vertically with wall distance 3": Pipe Support Clamping made of 1. Profile Bracket having Wall Distance 3" made of Low Carbon Hot Roll Gauge Corrected (HRGC) Steel (IS 1079 DD); material size 32 mm x 3 mm with ribs and notch are Hot Dip Galvanzied + Zn Al Flake coated having Salt Spray Test (Test method - ASTM B-117-2019) result above 2000 hrs with SS304 Hex Flange Bolt with Serration 5/16 x 3/4 (A/F 13mm) as per DIN 6921and SS304 Hex Flange Nut BSW 5/16 x 18 x 8 x 13 with Serration as per DIN 6923. 2. Continuous Slotted "C" Channel with ribs to be used of size 10" made of Low Carbon Hot Roll Gauge Corrected (HRGC) steel (IS 1079 DD) are Hot Dip Galvanzied + Zn Al Flake coated with material thickness of 3mm. 3. U bolt R/M are made of low carbon mild steel with Rod diameter 7 mm approx.; Zn Al Flake coated with noise absorbing semi transparent ribbed silicon rubber sleeve; with Hex Flange Nut BSW 5/16 x 18 x 8 x 13 with Serration set as per DIN 6923 - Zn Al Flake coated. Hotdip Galvanizing: As per IS 2629 (1985) - 610 grams/m2 (> 85 microns). Material Grade : IS 1079 DD used as per MTC confirms to EN 10204 3.1. Material Qty. for one unit : 1. Profile Bracket Wall distance 3" - 2 Nos. 2. Continuous Slotted C Channel of Size 10" - 1 No.; 3. U Bolt R/M for 4" (110 mm) CI or PVC Pipe Dia. - 1 No.; and 4. Justi Khilla 2 1/2" Zn coated - 4 nos. Fixing Details: Pipe Support Clamping Unit to be fixed at every metre distance in the duct as specified in the Technical Drawing No. : CE Jaipur Zone - Jaipur: TD/2022/01.
Dismantling existing 110mm/ 75 mm bore AC Pipe/ PVC/CI pipes set in cement mortar etc complete all as specified and directed.
Dismantling water tanks Capacity exc 250 & not exc 500 Litres of any description and removing to store etc complete all as specified and directed.
S&F Rotational moulded polyethylene water storage tanks (white colour) 500 litres capacity tripple layers ISI Marked (cylindrical vertical with closed top) hoisted and fixed in position all as specified in SSR Part I etc complete all as specified and directed.
Disconnecting existing tanks, exc 500 & not exc 1000 Litres setting aside (or lowering if required) for repairs, cleaning, etc. and hoisting if required reconnecting and re-fixing in position etc complete all as specified and directed.
Supplying and fixing factory made PVC cabinet of 18 mm thickness consisting of panel of 18 mm thick celluca ply of density 600 Kg.cbm density with prelaminated sheet on one side cut in desired size of shutter and fixed with frame as in cabinet boxes of size 1.2m x 0.6mx 0.30m with 2 x vertical partitions and shutter full size above the kitchen cooking platform and/or other platform including all necessary fittings and fixtures like nickle plated clip hinges, knobs, channels etc including fixing in any position with screws and roll plugs/fasteners complete as per Manufacturesrs specification and drawing etc complete all as specified and directed. Note : (i) The rate of tems like cupboard knobs, stainless steel channel, CP plate clip hinges shall be included in the quoted rate by the contractor. Nothing extra shall be paid at later stage on this account. (ii) The measured area for payment purpose shall be front elevation only.
Supplying and fixing factory made PVC shutter of 18 mm thickness consisting of panel of 18mm thick prelaminated celluka ply of density 600 Kg.cbm density manufactured by an ISO 9000 certified company using for shutter celluca ply cut in desired size of shutter and fixed with frame of kitchen accessory/cupboard at all four edges of shutter using 13/6 size self tapping steel screws below cooking platform. Edge Banding tape 18mm wide of same colour of shutter will be provided on all the edges of shutter complete as per Manufacturesrs specification and drawing etc complete all as specified and directed. Note : (i) The rate of tems like cupboard knobs, stainless steel channel, CP plate clip hinges shall be included in the quoted rate by the contractor. Nothing extra shall be paid at later stage on this account. (ii) The measured area for payment purpose shall be front elevation only.
S&F in repairs 20mm bore Ball valves, high pressure, PTMT with epoxy coated Aluminium rod and high density plastic ball screwed for iron pipe (minimum 20mm - 210gms) and fixed in position etc complete all as specified and directed.
S&F in repairs 20mm bore Gun Metal globe or gate valve, with iron wheel head, screwed both ends for iron pipe and fixed etc complete all as specified and directed.
S&F in repair PVC connection 15mm bore dia with PTMT nuts of length 600mm long with adopter and washer at both end etc complete all as specified and directed.
Taking down Chowkhats or frame with shutters (without taking off shutters from the frames) exc 1.5 Sqm but n exc 4.00 Sqm each etc complete all as specified and directed.
Taking down Chowkhats or frame with shutters (without taking off shutters from the frames) not exc 1.5 Sqm each etc complete all as specified and directed.
S & F 35mm thick (2nd class hardwood ) plain factory made panelled door shutter (two panel) lock rail and panel of 12mm veneered particle board with commercial veneering on both faces. The size of rails and stile as per IS-1003 (Part I), kiln seasoned and chemically pressure treated each etc complete all as specified and directed.
S & F 35 mm thick, second class hardwood glazed and skeleton shutters open rebated and prepared to receive glass, gauge, etc (without sash bars) edges of framing plain chamfered or rounded fitted with cut and mitered securing beads for securing glass etc sizes of members of shutters as specified in SSR Part I Section 8 clause 8.24 (a) and fitted to chowkhats each etc complete all as specified and directed.
Supply and fixing 4.80mm thick sheet glass ordinary quality and glazing with beading and rubber gasket in square exc 0.5 sqm in each pane etc complete all as specified and directed.
Supply and fixing 5mm thick figured glass pin head type and glazing with beading and rubber gasket in square exc 0.5 sqm in each pane etc complete all as specified and directed.
M&L for Aluminum powder coated frame (Thickness of powder coating not less than 50 micron) as in window/ventilators half fixed and half louvers type and small window single leaf cut to size, jointed together with cadmium plated steel screws including rubber packing, aluminium beading or gasket for aluminium sections for fixing glass sheet and necessary fittings complete, screws plugs, handle, tower bolt, stay hocks etc complete all as specified as per TD drg No TD/2004/34(R) sht No 1/2 to 2/2 and directed. Notes :- (i) Weight of aluminium sections shall only be measured for payment purpose. (ii) The supply only rate of glass sheet shall be measured and paid separately
S&F anodized aluminium window and ventilator shutters, side hung type without sash bars, aluminium sections weighing all as per CEJZ drg No TD/2004/34(R) sht 1/2 to 2/2, powder coated of any colour as approved (Thickness or powder coating not less than 50 micron) including necessary joining cleats, glazing clips, rubber packing, anodized aluminium snap beading, screws, anodized aluminium fittings such as peg stays 150mm long (01 No) , hinges type B-21, 100 mm long (2 Nos), tower bolt, suitable handle etc complete all as specified and directed.
S&F powder coated (minimum thickness of powder coating shall be 50 micron) aluminium 3 track window with aluminium sections in approved colour including supply and fixing 5mm thick plain glass, wire mesh, aluminium shutter handle, shutter lock PVC track gasket, EPDM rubber gasket on glass of weather tightening along with lock, including sealing any gap between window and marble/wall with silicon sealing making it water proof in all manner etc complete all as per TD Drg No. CEJZ TD/2004/65R and as specified by Engr-in-charge.
S&F for framed work such as grills, gratings, etc.. with ends of bars shouldered and/or riveted, or forged into spikes; framed guard bars; barred iron doors; ladders; framed balusters; walk ways; railings; framework of water tanks and similar work conforming to Fe.290.Gde-E-165 etc. complete all as specified and directed.
S&F solid PVC door frame of size 50mmx47mm made out of 5mm, single side prelam PVC sheet used and edges will be painted to match with prelam sheet, reinforced with MS square tube & fixing in opening including hold fast etc complete all as specified and directed. Note :- The SS Butt hings shall be paid separately as supply only under respective items)
S&F factory made solid PVC Moulded door shutter with particle board core 28 to 30mm thick (Stiles) with 2,4 or 6 raised panel design with 2mm thick Moulded Prelam PVC Sheet on front face & 2 mm plain colour PVC sheet on back face, supplying and fixing in frame at site as per specification etc complete all as specified and directed.
S & F mild steel cupboard shutter with frame, Godrej pattern made out of 22 guage mild steel sheet including chromium plated MS handle with proper locking arrangement (brass mortice lock vertical type size 65mm 4 lever with escutcheon plates & two keys) with & including two coats of spray painting with synthetic enamel paint of approved tint over a coat of red oxide primer including fixing with 6 Nos 12 mm dia bolt 150mm long grouted in brick wall/concrete including making good the disturbed surface as original etc complete all as specified and directed. Note :- The measurement shall be taken of front elevation and not girth wise for payment purpose.
Supply and fix Stainless steel wire cloth, 0.36 mm nominal dia of wire and average width of aperture 1.40mm and fixed with stainless steel staples etc complete all as specified and directed.
Supply and fixing 100mm length butt hinges extruded aluminium alloy with galvanised mild steel hinge pin anodised and fixed type B-21 etc complete all as specified and directed.
Supply and fix 100mm length Butt hinges, medium weight, cold rolled mild steel and fixed etc complete all as specified and directed.
S&F 200mm length of bolt aluminium anodised barrel tower bolt of extruded section and fixed etc complete all as specified and directed.
S & F 150 mm length of bolt aluminium anodised barrel tower bolts of extruded section and fixed etc complete all as specified and directed.
S & F 150 mm length extruded aluminium alloy handles , fabricated type, anodised and fixed etc complete all as specified and directed.
S&F 250mm length bolt aluminium alloy, anodised sliding door with hasp, staple (bolt type) and fixing clips of sheet , cast or extruded sections and fixing bolts and sliding bolts of extruded sections or cast-aluminium alloy and fixed etc complete all as specified and directed.
S & F in repairs Stainless steel Curtain rod not less than 25 mm dia with chromium plated including both sides finnials and bracket fancy type fixed in position by drilling holes in walls and fixed the brackers with rawl plug and steel screw etc complete all as specified and directed.
M&L for 75mm thick cement concrete (1:3:6) type C2 using 20mm graded stone aggregate as in plinth protection. Plinth protection laid to slope 1 in 30 in bays not exceeding 2 mtr in length. Exposed surfaces shall be finished even and fair without using extra cement. Joints of 6mm wide and 10mm deep shall be provided along the wall and bays and same shall be filled with bitumen mastic (1:3) complete all specified and directed.
Demolition of Brickwork or stone/boulder masonry, built in cement mortar including all quoins, arches, pillars etc, but excluding ashlars facings, dressed stonework and precast concrete articles etc complete all as specified and directed.
M&L for brick work with Old size Fly ash ’ bricks, straight or curved on plan exc 6 m mean radius built in cement mortar 1:6 etc complete all as specified and directed.
M&L for Brickwork with subclass ‘B’ bricks, straight or curved on plan to any radius in half brick thick built in cement mortar 1:4 etc complete all as specified and directed.
M & L for 20mm thick Granite (of any type) work (table rubbed and polished) in steps, jambs, pillars, window-cills, cooking platform, staircase treads and like jointed over and including 15mm thick screed in cement mortar (1:6) and pointing in white cement (1:2) using marble dust with admixture of pigment to match with shade of granite etc complete all as specified and directed. Note:- The colour of Granite shall be approved by GE and the same shall be provided by contractor without any extra cost. No misunderstanding shall be entertained at later stage.
M&L for machine cut Kota stone 20-25 mm thick as in riser of steps, skirting, dado and pillar set over cement screed and jointed with grey cement slurry mixed with pigments to match the shade including rubbing and polishing including 10 mm thick screed /rendering in CM 1:4 etc complete all as specified and directed.
M&L for grinding/polishing of existing terrazo/Kota stone in flooring and skirting/dado using suitable size of grinder stone butty as per requirement including fill up of joints/disturbed portion with filling material of floor etc and to the entire satisfaction of GE etc complete all as specified and directed in the following stages:- (a) FIRST STAGE : Washing cleaning, joint filling(where required) by using grey/white cement and grinding the floor by using suitable butty to achieve smooth, spotless surfaces. (b) FINAL STAGE : Again cleaning, washing and grinding the floor by using suitable butty and polishing with bee wax polish to receive smooth floor etc complete all as specified and directed.
Rounding the edges of stone slabs one edge, such as in steps, cooking platform and other similar situations etc complete all as specified and directed.
M&L for drilling holes for pipes etc in cooking platform stone slab including RCC slab not exc. 25mm dia and exc. 100mm depth etc complete all as specified and directed.
M&L for rendering 15mm thick in cement mortar 1:6 faces other than fair of brick work or concrete surfaces finished even and fair without using extra cement etc complete all as specified and directed.
M&L 5mm thick rendering in cement mortor 1:3 on concrete surfaces as in ceilings (with sunshed, chajja etc) and finishing surfaces even and smooth without using extra cement etc complete all as specified and directed.
M&L rendering 15 mm thick on brick masonry surfaces in CM 1:4 mixed with WPC 3% by wt of cement and finished even and smooth without using extra cement etc complete all as specified and directed. Note :- (i) Supply only WPC shall be measured and paid separately under respective items. (ii) Contractor shall be arrange scaffolding and other tools/plants for taking down of plaster and safety equipments at any height. The cost of arrangement of scaffolding and other material shall be included in the quoted rate by the contractor. Nothing extra shall be paid at later stage on this account.
M&L for APP based polymeric membrane minimum weighing 3kg/sqm and minimum 3mm thick reinforced with polyester non woven fabric weight not less than 150gms/sqm) laid over and including a coat of primer and a coat of hot blown bitumen layer on plastered surface laid by torched application complete all as per manufacturers specification including taking out old existing roof treatment alongwith roof tile/padding etc complete all as specified and directed. Note :- The quoted rate shall be deemed to included of taking down/cleaning/removing material obtained from existing treatment on roof. Nothing extra shall be paid at later stage on this account.
S&F Heat Resistant Terrace Tiles (300mm x 300mm x 10mm) with SRI (solar refractive index)>78, solar reflection>0.70 and initial emittance > 0.75 on waterproof and sloped surface of terrace, laid on 20mm thick cement sand mortar in the ratio of 1:4 (1 cement : 4 coarse sand) and grouting the joints with mix of white cement & marble powder in ratio of 1:1, including rubbing and polishing of the surface upto 3 cuts complete, including providing skirting upto 150mm height along the parapet walls in the same manner all as per manufacturers specification etc complete all as specified and directed.
M&L for taking down and removal of loose / disintegrated old concrete / plaster and applying 10mm thick bonding coat of modified styrene butadiene emulsion (SBR Bonding agent i.e. Nitobond SBR 45) in proportion 1 (Nitobond SBR 45) : 1(water) : 3 (OPC) by volume with the brushes etc to bind New Cement plaster/ polymer Modified plaster/ concrete/ screed concrete with old surface etc complete all as specified and directed.
M&L applying 15mm thick plaster with polymer modified mortar fortified with SBR (Nitobond SBR 45 ) in proportion 1:3 by weight 5 litres Nit bond SBR 45 to added to 50 KG Cement with 13 litre water addition, finished surface to match with existing adjoining surface of ceiling, beams and alike etc complete all as specified and directed.
M&L and applying two or more coats of 2 component zinc based epoxy rust preventer (Nitozinc Primer-M) on corroded reinforcement after cleaning and removing the rust from corroded reinforcement with the help of wire brush and treating it with rust remover (Reebaklens RR) including thoroughly cleaning washing air blowing brushing etc complete all as specified and directed. Note : Qty of Zinc based epoxy rust prevent or only shall be taken into account for payment purpose on the basis of actual consumption.
M&L for Rough cast plaster on exterior walls applying the under coat of cement and sand mortar 1:3 not less than 10mm thick and while it is still in plastic state the roughcast mixture consisting of crushed stone or fine gravel aggregate (size between 6 to 12mm ) mixed with coarse sand and cement in the ratio of 1:1:1 shall be applied and finished even. The mix of cement and sand shall made slightly wetter than normal for rendering to ensure that larger aggregate are thoroughly covered etc complete all as specified and directed.
Supply only Liquid water proofing compound. Note:- Actual Qty shall be measured and paid for as per manufacturer’s instructions
M&L two coats of synthetic enamel paint over one coat of pink primer on wood or wooden based surface exc. 10cm width or girth including preparation of new or previously untreated surfaces etc complete all as specified and directed.
M&L for One coats of synthetic enamel paint on Old Painted wood or wooden based surface exc. 10cm width or girth including preparation etc complete all as specified and directed.
M&L for applying two coat of Synthetic enamel paint over a coat of red oxide primer on new steel based surfaces exc.10cm width or girth including preparation etc complete all as specified and directed.
M&L for one coats of synthetic enamel paint on old steel surfaces of any description over 10cm width or girth including preparation etc complete all as specified and directed.
M&L for preparation of newly plaster surfaces of ceiling and applying three coats of white wash etc complete all as specified and directed.
M&L for preparation of old plastered surfaces of ceiling and applying two coats of white wash etc complete all as specified and directed.
Material and labour for two coats of smooth interior acrylic emulsion with rich matt finish on new plastered surface of wall having VOC less than 50 grams per litre complying LEEDS criteria @1 litres (undiluted) /10 sq metre diluted with water in 2:1 ratio applied over priming coat with fully automatic airless spray machine of paint application with a flow speed of min 1 litre per minute having a pressure of 3300 PSI. Allow 6-8 hrs to dry the surface in both the coats of paint after preparation of new plastered surfaces as per manufacturer instructions over and including waterproof/weather proof cement based putty @ 1 Kg(undiluted) per sq mitre of average thickness 1 mm over the new plastered surfaces including necessary scaffolding arrangement at any height etc. complete all as specified and directed . Note : - (i) Sanding of surface to be done by mechanical sander with 1500 - 2700 rpm, with internal dust extraction system for clean environment certified by paint manufacturer. Proper masking to be carried out before primer and paint application (ii) The cost of arrangement of scaffolding and other material shall be included in the quoted rate by the contractor. Nothing extra shall be paid at later stage on this account.)
Material and labour for two coats of smooth interior acrylic emulsion with rich matt finish on old surface of wall having VOC less than 50 grams per litre complying LEEDS criteria @1 litre (undiluted) /10 sq metre diluted with water in 2:1 ratio applied over priming coat with fully automatic airless spray machine of paint application with a flow speed of min 1 litre per minute having a pressure of 3300 PSI. Allow 6-8 hrs to dry the surface in both the coats of paint after complete removal of existing surface/plastered surfaces as per manufacturer instructions over and including waterproof/weather proof cement based putty @ 1 Kg(undiluted) per sq metre of average thickness 1 mm over the old plastered surfaces including necessary scaffolding arrangement at any height etc. complete all as specified and directed. Note : (i) Sanding of surface to be done by mechanical sander with 1500 - 2700 rpm, with internal dust extraction system for clean environment certified by paint manufacturer. Proper masking to be carried out before primer and paint application (ii) The cost of arrangement of scaffolding and other material shall be included in the quoted rate by the contractor. Nothing extra shall be paid at later stage on this account.
Material and labour for two coat water based premium acrylic smooth exterior emulsion on new plastered surfaces of wall of approved colour with silicon additive & Color stay Technology, Excellent Dirt Pick up resistance with low VOC less than 50 gram/ litre as per the LEEDS specifications, Anti Algal properties in two coats @ 1.79 litre (undiluted)/ 10 sqm diluted with water as per manufacturer instructions applied over priming coat with fully automatic airless spray machine of paint application with a flow speed of min 1 litre per minute having a pressure of 3300 PSI. Allow 6-8 hrs to dry the surface in both the coats of paint after preparation of existing new surface/plastered surfaces over and including waterproof/weather proof cement based putty @ 1 Kg(undiluted) per sq metre of average thickness 1 mm over the new plastered surfaces including necessary scaffolding arrangement at any height etc. complete all as specified and directed. Note : - The cost of arrangement of scaffolding and other material shall be included in the quoted rate by the contractor. Nothing extra shall be paid at later stage on this account.
Material and labour for two coat water based premium acrylic smooth exterior emulsion on old surfaces of wall of approved colour with silicon additive & Color stay Technology, Excellent Dirt Pick up resistance with low VOC less than 50 gram/ litre as per the LEEDS specifications, Anti Algal properties in two coats @ 1.79 litre (undiluted)/ 10 sqm diluted with water as per manufacturer instructions applied over priming coat with fully automatic airless spray machine of paint application with a flow speed of min 1 litre per minute having a pressure of 3300 PSI. Allow 6-8 hrs to dry the surface in both the coats of paint after complete removal of existing surface/plastered surfaces over and including waterproof/weather proof cement based putty @ 1 Kg(undiluted) per sq metre of average thickness 1 mm over the old plastered surfaces including necessary scaffolding arrangement at any height etc. complete all as specified and directed . Note : The cost of arrangement of scaffolding and other material shall be included in the quoted rate by the contractor. Nothing extra shall be paid at later stage on this account.
Treatment for sunken portion is as follows :- M & L for water proofing treatment in sunken floors as described here under:- (i) Demolition of PCC in sunken portion /floors and Cleaning the sunken/lowered portion of RCC slab surface (including vertical total depth plus skirting height) of floors by wire brush, chisel out any mortar sticking to the surface and brooming completely. Provision of 40mm thick average PCC 1:2:4 type B-0 using 12.5mm graded aggregate as in padding concrete to achieve proper slope including S& f in repair 40 mm dia, 450 mm long medium grade spout pipe and cutting holes in bricks or RCC wall for the same (ii) Rendering of uneven surfaces at bottom and sides up to floor level with 15 mm thick CM 1:4 mixed with and including integral water proofing compound Sika Plastocreat plus or equivalent make in Fosroc / Thremax as approved by GE @ 0.2% by weight of cement consumed including filling it with water to check dampness and seepage and where dampness / seepage is noticed, nozzles shall be fixed and grouting carried out. (iii) All junctions points of side wall where CI/GI/PVC pipes are passing through shall be sealed with epoxy putty Sikaguard 694 F(I) or equivalent make in Fosroc / Thremax as approved by GE.
(iv) After drying putty, wash the slab and sides of sunken portion with water and make it clear and clean. (v) Applying two coats of polymer modified cementious water proof coating with Sika Topseal 107 or equivalent make in Fosroc / Thremax as approved by GE in two coats @ 3kg/sqm to sanwiched with glass fibre reinforcement: Sika Fab-1 or equivalent make in Fosroc / Thremax as approved by GE over base coat as per manufacturer's instruction to bottom and vertical sides up to finished floor level+100mm height. The thickness of two layer shall be 1mm. When the second layer is still sticky, coarse sand spray shall be carried for the vertical and bottom surface of the sunken portion.
(vi) All pipes laid in sunken portion shall be covered with 50mm thick PCC 1:3:6 all round after painting with anticorrosive paint . (vii) The sunken floor shall be filled with lean concrete 1:5:10, type E-2 with 40 mm graded stone aggregate) Note :- Test the water proofed area (ponding test) by filling water for at least 72 hours and tested for leakage seepage and to the entire satisfaction of GE. Test record for each sunken slab shall be maintained. The treatment shall be carried out by authorised applicators of chemicals. (i) Polymeric membrane shall be laid in sunken floor and on sides upto finished floor level (ii) The waterproofing treatment shall be got carried out by the manufacturer or their authorized applicators. (iii) Cost of testing and all M&L including above aspects shall be inclued in the quoted rates by the contractor. Nothing extra shall be paid at later stage on this account.
S&F Framed brackets of angles or tees with web and flanges cut to shape, drilled and countersunk for screw, including bending and welding angles, as necessary, gusset plates, riveting, etc.. not exc 10 kg each brackets, conforming to Fe.290.Gde-E-165 (Brackets over 10 kg each to be measured under 'Structural Steel') all as specified and directed. Note:- Contractor shall be arrange scaffolding and other tools/plants and safety equipments at G+2 buildings The cost of arrangement of scaffolding and other material & labours shall be included in the quoted rate by the contractor. Nothing extra shall be paid at later stage on this account.
M&L for Framed work as in doors or gates of angle or other section with gusset plates, rails, braces, etc., complete, drilled for fixing of steel sheeting or other covering. Doors, etc. to be prepared for hanging or sliding with and including either hooks and hinges or steel hanging door fittings (exclusive of steel sheeting or other covering, running rails and guides) and hanging; also fastening and fixing etc complete all as specified and directed by Engr-in-charge.
M&L for Pre painted galvalume aluminium zinc coated GI based Plain steel sheet 0.5mm thick of any colour having tensile strength of 550 Mpa as in roof covering/cladding, chajjas etc to wall, fixed with self tapping screws on structural steel frame and including fixed to wall by making 10mm deep grove etc complete all as specified and directed.
S&F in repair vitreous china white wash hand basin flat back of size 550 x 400 mm including CI/MS brackets excluding taps, waste, chain and plug and porcelain stopper but including cutting for and pinning in brackets etc complete all as specified and directed.
S&F 15mm bore brass CP sink mixer for mixing hot & cold water screwed down for iron pipe and fixed etc complete all as specified and directed.
Taking down carefully copper/aluminium point wiring (light, fan, socket or power) complete,fittings such as switches, ceiling roses, pendants, regulators sockets etc, removing materials to store for keeping in safe custody for reuse at site and making good disturbed surfaces of walls, floors, etc. etc complete all as specified and directed.
M&L for concealed point wiring with two single core PVC insulated, unsheathed multistranded copper conductor cable of size 1.5 Sqmm (FRLS) drawn in and including electrical grade PVC conduit 20 mm dia concealed on wall/ceiling/floor including PVC insulated unsheathed earthwire with multi-stranded copper conductor of size 1.5 Sqmm (FRLS) including MS shunk sheet metal box with modular sheet top cover of required module for mounting switches, socket itc one light point controlled by one, one way switch including cutting/ Chases complete all as specified and directed by Engr-in-charge.” Note :- Quoted rate shall include making good to the disturbed surface including plastering and painting to match with the existing colour for one light point controlled by one, one way switch complete all as specified and directed by Engr-in-charge.
All as per item No. 108 here-in-before but for one fan point controlled by one switch and regulator and exhaust point controlled by one switch.
All as per item No. 108 here-in-before but for one bell/buzzer point controlled by one bell push
All as per item No. 108 here-in-before but for one light point controlled two ,two way switch
All as per serial item No. 108 here-in-before but for one 3 pin 5/6 Amp socket outlet controlled by one 5 Amp switch on same board.
All as per serial item No. 108 here-in-before but for one 3 pin 5/6 Amp socket outlet controlled by one 5 Amp switch on independent board.
All as per serial item No.108 here-in-before but for one 3 pin 15/16 Amps socket outlet controlled by one 15/16 Amps switch on independent board with 2.50 Sqmm single core PVC insulated and unsheathed multistranded copper conductor FRLS cable 1100 Volt grade including 2.50 Sqmm single core PVC insulated and unsheathed multistranded copper conductor FRLS cable 1100 Volt grade as continuous earth wire in green colour.
All as per serial item No.108 here-in-before but for one 3 pin 15/16 Amps socket outlet controlled by one 15/16 Amps switch on independent board with 4.00 Sqmm single core PVC insulated and unsheathed multistranded copper conductor FRLS cable 1100 Volt grade including 4.00 Sqmm single core PVC insulated and unsheathed multistranded copper conductor FRLS cable 1100 Volt grade as continuous earth wire in green colour for AC etc complete all as specified & directed.
Supply and fix modular switch one way 6A, 1 module, 240 Volts complete all as specified and directed.
Supply and fix modular switch two way 6A, 1 module, 240 Volts complete all as specified and directed.
Supply and fix modular switch one way 16A, 1 module, 240 Volts complete all as specified and directed.
Supply and fix modular socket 6A, 2/3 Pin combined 2 module complete all as specified and directed.
Supply and fix modular socket 6A/16A, 2/3 Pin combined 2 module complete all as specified and directed.
S&F in repair modular bell push 5 Amps 240 Volt, One Modular type etc complete all as specified and directed.
S&F in repair multi music type AC 230 volts single pole , modular type etc complete all as specified and directed.
Supply and fix in repair ceiling rose modular type surface bakelite 65mmx50mm with two or three terminal etc complete all as specified and directed.
Supply and fix LED batten (1.2M) made of CRCA sheet housing with a PC glossy diffuser duly prewired connection having nominal system lumen output of 2000 Lumen at minimum system efficiency of 115 Lumen per watt and total power consumption not mor than 17 watt including driver. It has a rated system life time of 40000 burning hour at L 70 and should have temp of 6500 K CRI grater than 80, THD less than 10 and PF greater than 0.95 complete all as specified and directed. Make : Philips cat part BN308C LED20S-6500L 120PSU WH , Compton cat part CIS -305-40-57-SL-DP-NWH, Havells Cat part STOUTPLUS600BS20WLED840SPCWH
Supply & fix AC box single pole and neutral enclosure with a two pin and socket complete with one single pole MCB 240 volts, 32 Amps etc complete all as specified and directed.
Supply and fix in repair lamp holder PVC/Polycarbonate type with back plate suitable for batten fittings etc complete all as specified and directed.
Supply and fixing in repair Adore LED lamp of 10 watt etc complete all as specified and directed. Make :- Havells cat part No. LHLDERHEML8X010 or equivalent of Philips / Crompton Greaves / Wipro/Bajaj
Supply and fix exhaust fan PVC body AC single phase 230 volt of size 300mm sweep with blade and frame with louvers including making hole and making good of disturbed surface etc complete all as specified and directed.
Supply and fixing in repair stepped type electronic fan regulator, modular type type and connecting up, ISI marked, 240 Volts etc complete all as specified and directed.
Taking down ceiling fan, sealing cable end, dismantling blades and removing fan and blades and fix the dame after painting of ceiling fan complete, in situ with synthetic enamel paint by spraying including filling cavities with filler, one coat after cleaning all dust etc complete all as specified and directed. Note :- (i) MES No CA NO to be marked with black paint on ceiling fan. (ii) If minor repair of ceiling fan required same deemed to be included in quote rate as per GE directions
Supply and fix in repair sheet metal enclosures double door type suitable for fixing MCB's, SPN with 200 Amps rated bus bar,8 way, 240 Volts, grouted in wall etc complete all as specified and directed.
Taking down old UNSV MCB SP/SPN of any make and capacity etc complete all as specified and directed.
S&F in repair MCB 32 Amp, single pole & neutral,240 volt etc complete all as specified and directed.
S&F in repair MCB SPN 40 Amp, Single pole & neutral, 240 volt etc complete all as specified and directed.
S&F in repair MCB 6-32 Amp, single pole 240 volt etc complete all as specified and directed.
Taking down old UNSV submain wiring aluminium /copper incl conduit cassing capping etc complete all as specified and directed.
S&F sub main wiring and including passing through PVC conduit pipe 1100 Volts grade with PVC flexible cable copper conductor unsheathed multistranded single core of size 6 sqmm and continuous earth with PVC flexible cable copper conductor unsheathed multistranded single core of size 6 sqmm of green colour confirming to IS 694/1990 etc complete all as specified and directed Note: Two runs of cable with one run of earth wire and one run of PVC Conduit should measured as one length)
Taking down & Refixing of hot water storage geyser of capacity 25 Litre including making electrical connections etc complete all as specified and directed. Note :- (i) If minor repair of Geyser required same deemed to be included in quote rate as per GE directions. (ii) MES No CA No to be painted with black paint after painting of geyser with synthetic enamel paint by spraying including filling of cavities with filled removing of dent, one coat after cleaning of dust.
Supplying, laying, jointing, testing and commisioning of size 3.5 core 50 Sqmm LT under ground cable, XLPE insulated, screened, PVC bedded, galvanised steel strip or wire armoured, electric power cable (heavy duty) with multistranded aluminum conductors, 1100 Volt grade, laid in trenches / ducts / encased in GI pipe / fixed to pole/wall complete including taking down old Unsv LT cable etc complete all as specified and directed. Note :- Exacavation and earth work, GI pipe for laying of cable, sand cushioning, cable protection cover shall be measured and paid seprately under respective items of the BOQ'.
Boring of holes under road, payment hard standing by trench less technology using ultra sound technique and necessary machine including supply and fixing HPDE pipe of 80 mm bore suitable for 0.4 mpa working pressure etc complete all as specified and directed.
Excavating in trenches not exc 1.5 metre wide and not exc 1.5 metre in depth for foundation or for shafts, walls, manholes, laying of cables, pipes etc not exc 10 Sqm on plan and getting out in soft/loose soil etc complete all as specified and directed.
Returning, filling in, including spreading, leveling watering and well ramming in layers not exc 25 cm thick in soft/loose soil etc complete all as specified and directed
Removal of excavated soil/ material to a distance not exc 50 metre and depositing where directed at a level not exc 1.50 metre above the starting point etc complete all as specified and directed
M/L for brick work with FLY ASH BRICKS (As Per IS-13757(1993) burnt clay fly ash building bricks), (OLD SIZE BRICKS) with width equal to the length of the brick laid dry & flat abutted with each other with gap between adjacent bricks not exc 10 mm over UG cable for protection etccomplete all as specified & directed.
M&L for dry sand and punning for cushioning to under ground cable all as directed. Note :- For the purpose of payment only punned thickness shall be measured.
M&L,Earthing complete with galvanised mild steel earth electrode plate 600 X 600 X 6 mm thick buried directly and vertically in ground (earth pit not less than 2.25 metres deep below ground level) with top edge of the plate not less than 1.5 metres below normal ground level, connected to galvanised earth lead wire 4 mm dia by means of bolts, nuts, check nuts and washers of galvanised iron or steel all as shown in electrical Plate No 3 of MES SSR Part-I connected to continuous earth lead for main switch board or main control board all as specified and testing on completion including provision of earth wire protected by galvanised iron 15 mm bore light grade pipe with all fittings from the earth electrode fixed along pole with and including 25 x 6mm flat iron clamp, bolts, nuts and washers and watering pipe shall be 20 mm bore GI medium grade from top of the earth electrode to bottom of the earth pit including all excavation and earth work in any type of soil and removal of soil upto 50 metre, PCC pit with pre-cast RCC cover with handle, charcoal/salt, funnel , CI frame etc complete all as specified and directed.
Note :(i) The concrete pit shall be made in PCC 1:2:4 type B-O, using 12.5mm graded crushed stone aggregate 40mm thick precast cover slab of RCC (1:2:4), type B-1, using 20mm graded crushed stone aggregate with suitable MS handle in lieu of CI cover. Reinforcement in cover shall be of 8mm dia TMT bars laid @150mm c/c both ways. (ii) Item includes the cost of GI pipe for protection of earth wire including earth wire up to 7.5 Metre. (iii) Any variation of GI pipe and GI wire below or above 7.5m shall be adjusted through deviation. '(iv) Earth electrode shall be surrounded by adequate quantity of charcoal dust and salt to a packed thickness of 15 cm on all sides
S&F LED type street-DRACO SERIES light luminaire 20 watt 230 V 50 Hz including all necessary fitting accessories and LED etc complete all as specified and directed. Make: Compton Cat Part No TRP-415-20-57-SL-LM-NBK, Havells Cat Part No Sundown 20Watt, Philips Cat Part No BRP330LED24CWR5NPCPSU S1 V1 or equvalent as mentioned in Appendix 'B"
S&F mild steel powder coated retractable self closing type hinges 100mm along with necessary welding to steel chowkhat etc complete all as specified and directed.
Supply and fix MCB DB distribution box, 3 phase/TPN for 415 volts 04 way double door with bus bar rating 200 Amp dust and vermin proof etc complete all as specified and directed by Engr-in-charge.
Supply and fix MCCB 415 volts, 4 pole, 100 Amp thermal & magnetic protection based etc complete all as specified and directed.
Singh Associates (BID ID -3132271)
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .