Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹13.2 LAccepted-AOC NEAR AVON PUBLIC SCHOOL DABHANW POST DANDI NAINI PRAYAGRAJ 211008 | PRAYAGRAJ | PRAYAGRAJ | UTTAR PRADESH | 211008 | L1 | Accepted-AOC Being L1 | |
| 2 | L2₹14.7 L+₹42,370 (2.96%)Rejected-Finance SA 15 144 S 1 CHANDAN HERITAGE HAVELIA CHAURAHA SARNATH VARANASI U P 221007 | VARANASI | VARANASI | UTTAR PRADESH | 221007 | L2 | Rejected-Finance Being L2 | |
| 3 | L3₹15.1 L+₹81,428 (5.70%)Rejected-Finance 307 SADAR BAZAR LUCKNOW UP 226002 | LUCKNOW | UTTAR PRADESH | 226002 | L3 | Rejected-Finance Being L3 | |
| 4 | L4₹16.5 L+₹2.2 L (15.6%)Rejected-Finance | L4 | Rejected-Finance Being L4 | |
| 5 | L5₹17.0 L+₹2.7 L (18.9%)Rejected-Finance | L5 | Rejected-Finance Being L5 |
Tender Value
₹25 L
EMD Value
₹50,000
Closing Date
15 Jun 2023, 6:00 pmClosed
GE E/M Lucknow
Garrison Engineer E/M, 36 LBS Marg, Lucknow Cantt, Lucknow (U.P.) PIN 226002
REPAIR/MAINT/REPLACEMENT OF UNSV STREET LIGHT, FLOOD LIGHT, HIGH MAST LIGHT, GATE LIGHT, FOCUS LIGHT, GARDEN LIGHT AND CONNECTED ITEMS AT BASE HOSP, SOI AND PDA IN THE AREA OF AGE E/M (HOSP) UNDER GE E/M LUCKNOW
2023_MES_599075_1
GE/EM/LKO/HOSP/T-12 OF 2023-2024
Open Tender
Electrical and Maintenance Works
Item Rate
270 days
Lucknow
As per NIT
8 documents required · 8 mandatory
₹500
GE E/M Lucknow
₹50,000
Yes
31 Jul 2023
27 May 2023
17 Jun 2023
27 May 2023
15 Jun 2023
10 Jun 2023
Amount
Supplying and laying or fixing in replacement, jointing and testing LT under ground electric power cable crossed linked polyethylene ( XLPE) insulated, galvanised steel strip or wire armoured, ISI-7098 Marked, with aluminium conductor multi stranded , heavy duty 1100 Volts grade of size 10 sqmm cross sectional area, 2 core, laid in trenches/ laid under floor or fixed naked with walls / on poles/ in ducts /in GI pipes etc. with and including MS Clamps, nuts , bolts, washers complete all as specified and directed. Note :- Excavation, earth work, sand cushioning, protection bricks/ tiles/ block and pipe shall be measured and paid separately under appropriate items.
All as per item No 1 above but of size 10 Sqmm 4 core
All as per item No 1 above but of size 16 Sqmm 4 core
All as per item No 1 above but of size 25 Sqmm 3.5 core
All as per item No 1 above but of size 35 Sqmm 3.5 core
All as per item No 1 above but of size 50 Sqmm 3.5 core
All as per item No 1 above but of size 70 sq mm 3.5 core
All as per item No 1 above but of size 95 Sqmm 3.5 core
All as per item No 1 above but of size 120 Sqmm 3.5 core
All as per item No 1 above but of size 240 Sqmm 3.5 core
Excavating in trenches, not exceeding 1.5 m wide and not exceeding 1.5 m in depth for laying of cables, pipes etc. and getting out including trimming the sides and forming bottom surfaces to required levels in soft/loose soil complete all as specified and directed.
Returning, filling in, including spreading, levelling, and well ramming in layer not exceeding 25 cm thick in soft/loose soil complete all as specified and directed.
Removing excavated material ( soils) not exceeding 50m and depositing where directed at a level not exceeding 1.5 m above the starting point complete all as specified and directed.
Material and labour for river sand, washed and screened dry for cushioning to under ground cable in trenches below and around under ground cable including spreading and levelling complete all as specified and directed. Note :- Punned thickness shall only be considered for payment
M&L laying well burnt brick work with fly ash bricks as per IS 12894-2002, straight or curved on plan , laid flat with width equal to length of brick , laid dry over electric cable for protection complete all as specified and directed.
Boring/Drilling ( horizontally) manually under existing road ( maximum 10 M in width) suitable for passing GI tubing of 40 to 100 mm bore complete all as specified and directed.
S & F GI tubing 'Light' grade 40 mm for cable protection fixed in poles/walls/laid under roads/crossing etc incl taking out the rusted pipes, complete all as specified and directed.
All as per item No 17 above but size 50 mm bore dia
All as per item No 17 above but size 80 mm bore dia
Labour for taking out the unserviceable / faulty cable , finding the fault , cutting the cable , jointing with jointing kit using extra cable if required ,relaying of cables upto 300 sqmm 3.5 core ,connecting, rate included of excavation works, using old bricks complete all as specified and directed. (Note :- cable joints will be measured and paid seperatly under respectrive item of schedule).
Material & Labour for writting of existing pole with stencil out with white colour in black background and preparation of old painted surface of steel tubular pole 9 meter long above coping) and applying two coat of aluminium paint, making of strip of 300mm width (balck and yellow in alternate band) upto 1500 mm height with one synthetic enamel paint , rewriting pole No by painter with enamel paint, and painting the existing MS clamp with one coat of aluminum paint complete all as specifeid and directed.
Supplying and fixing in repair flat twin core ,1.5 sqmm nominal cross sectional area multistranded aluminium conductor cable, over all PVC sheathed, 1100 Volts grade heavy duty cable PVC insulated and PVC sheathed complete all as specified and directed.
Supplying and fixing in repair flat twin core ,2.5 sqmm nominal cross sectional area multistranded aluminium conductor cable, over all PVC sheathed, 1100 Volts grade heavy duty cable PVC insulated and PVC sheathed complete all as specified and directed.
Supplying and fixing in repair flat twin core ,6 sqmm nominal cross sectional area multistranded aluminium conductor FRLS cable, PVC insulated and sheathed 1100 Volts grade complete all as specified and directed.
M&L for old painted steel surface or iron surfaces of LT FPB of various size by scraping with steel wire brush/scrapper emery paper etc and applying one coat of synthatic enameled siemens grey/existing colour (painting shall be done by spray machine ) including hinge welding and fiting of new two number door for front and backside for thickness upto 3.15mm & size as per existing panel of the LT FBP door matching with the LT FBP including panel repair complete all as specified and directed.
S&F MCCBs four pole 16 KA, fixed type incl taking out unserviceable MCCB's and connecting,of capacity upto 100 AMPS complete all as specified and directed.
S&F MCCBs four pole 16 KA, fixed type incl taking out unserviceable MCCB's and connecting,of capacity 125 AMPS complete all as specified and directed.
S&F MCCBs four pole 16 KA, fixed type incl taking out unserviceable MCCB's and connecting,of capacity 160 AMPS complete all as specified and directed.
S&F MCCBs four pole 25 KA, fixed type incl taking out unserviceable MCCB's and connecting,of capacity 250 AMPS complete all as specified and directed.
S&F MCCBs four pole 36 KA, fixed type incl taking out unserviceable MCCB's and connecting,of capacity 400 AMPS complete all as specified and directed.
S&F Digital type Volt meter ( 0-500 V ) , 3 ph , class 1 including taking down unserviceable voltmeter, complete all as specified and directed.
S&F Digital type Ammeter (0-300 A) ,3 ph , class 1 including taking down unserviceable ammeter, complete all as specified and directed.
S&F indicator lamps (LED Type) including taking down unserviceable indicator lampsall, complete all as specified and directed.
S & F in repair MCB’s single pole with neutral, 6 to 32 Amps, 250 volts with 'B curve, fixed in existing PVC box including connecting complete all as specified and directed.
M&L for plain cement concrete 1:3:6 type D-2 using 40 mm graded stone aggregates, as in copping of poles complete all as specified and directed.
Disconnecting the LT cable from Panel / Pole, preparing the end for jointing including all earth work, Supply and fixing straight through heat shrinkable joint suitable for LT XLPE cable of size 3.5/4 core 10 to 16 sq mm, complete all as specified and directed.
All as per item No 36 above but size 25 to 50 Sqmm
All as per item No 36 above but size 70 to 120 Sqmm
All as per item No 36 above but size 150 to 185 Sqmm
All as per item No 36 above but size 240 to 300 Sqmm
Supplying, transporting, erecting and fixing Steel tubular swaged poles type 410 SP-31 ( 9.0 metres long) complete with cast iron base plate, finial, taper plug, bolts, nuts and screws as specified, including necessary excavation and earth work , PCC 1:4:8 type D2 in foundations below pole, PCC 1:3:6 type C2 around poles and PCC 1:3:6 type C1 as in plinth block , disposal of surplus soil to a distance not exceeding 50 m and depositing where directed, painting steel tubular poles exposed surafces with Aluminium paint two coats over one coat of red oxide primer and providing 300 mm wide bands (3 bands/ straps with synthetic enamel paint and 2 bands with Black bituminous paint ) from plinth block and numbering of poles , painting embedded portion of poles with one coat of bituminous paint complete all as specified and directed.
S&F MS Junction Box made of 1.6 mm thick MS sheet of size 300 x 200 x 150 mm complete with front openable hinged cover and locking arrangements with 4 Nos aluminium bus bar 100 Amps, mounted on porcelain insulator including MCB SP 10Amp , 10 KA-1No, fixed on box in Din rail complete with electrical connection fixed to pole with suitable size FI clamp nut bolts and washer including duly painted with powder coated paint complete including required size and length of copper conductor cable and making connections complete all as specified and directed.
S & F offload change over switch, 200 Amps, 415 volts, 4 pole in sheet metal enclosure conforming to IS:13947 (Part-3); IEC:60947-3 with locking facility including all connecting/ jointing materials and dismantling of existing change over switch, complete all specified & directed Make havells or equivalent as per complete all as specified and directed.
S & F on load change over switch, 63 Amps, 415 volts, 4 pole side handle type in sheet metal enclosure conforming to IS:13947 (Part-3); IEC:60947-3 with locking facility including all connecting/ jointing materials and dismantling of existing change over switch, complete all as specified and directed.
S & F off load change over switch (side operated handle) 400 Amps, 415 volts 4 pole in sheet metal enclosure with interlock door and pad lock facility including dismantling of existing change over switch, complete all as specified and directed.
Supply and fixing new generation ,energy saving ,environment friendly LED GATE LIGHT fitting,fully cast aluminium body finish with polyeurethene paint with acryilic window cover with B22 brass holder suitable for 15 to20 watt led bulb as light sopurce including making connections complete all as specified and directed.
Supply and fixing new generation, energy saving, environment friendly POST TOP LANTERN fitting, aluminium spun lamdscape luminaires with high power LED 25 watt as light sopurce including making connections complete all as specified and directed.
M&L Earthing complete with galvanised mild steel earth plate electrode 600x600x6.0mm thick, burried directly in ground to a depth not less than 2.25 metres deep below ground level with top edge of earth plate not less than 1.5 metre below normal ground level surrounded with adequate quantity of charcoal dust mixed with salt to a packed thickness of 15 cm all around the plate, using GI strip 32 x 6 mm as earth strip electrode bolted or rivetted to earth plate at one end and connected to equipments at another end, GI earth strip encased in and including 40 mm dia GI 'light grade' pipe from upper end of earth plate upto equipments,20 dia bore GI pipe 'light grade' as water pipe from earth chamber to upper edge of earth plate, Test point , GI funnel with wire mesh fixed on water pipe and PCC 1:2:4 type B-1 (using 20mm graded stone aggregate) as in pit chamber and RCC pit cover 50mm thick precast RCC 1:2:4 type B-1, duly reinforced with MS TMT bars 8mm dia @ 100 c/c both ways with 10mm dia MS round bar as in lifting handles, excavation, earth work including laying the GI pipe concealed in floor/wall all as described in electric plate of SSR Part I and testing on completion, complete all as specified and directed. Note :- If the desired earth resistance is not found, earthing shall be redone by the contractor at no extra cost to the department.
M&L Earthing complete with Copper earth Plate electrode 60x60cmx3.15mm thick, burried directly in ground ( earth pit not less than 2.25 metres deep below ground level) with top edge of the plate not less than 1.5 metres below normal ground level, Including connected to copper strip 20x3mm lead (upto 7.5 Mtr) by means of bolts, nuts, check nuts and washers of galvanised iron or steel all as shown in electrical plate connected to earthing test point all as specified or indicated including testing on completion.ith salt to a packed thickness of 15 cm all around the plate, and including 40 mm dia GI 'light grade' pipe from upper end of earth plate upto equipments,20 dia bore GI pipe 'light grade' as water pipe from earth chamber to upper edge of earth plate, Test point , GI funnel with wire mesh fixed on water pipe and PCC 1:2:4 type B-1 (using 20mm graded stone aggregate) as in pit chamber and RCC pit cover 50mm thick precast RCC 1:2:4 type B-1, duly reinforced with MS TMT bars 8mm dia @ 100 c/c both ways with 10mm dia MS round bar as in lifting handles, excavation, earth work including laying the GI pipe concealed in floor/wall all as described in electric plate of SSR Part I and testing on completion, complete all as specified and directed. Note :- If the desired earth resistance is not found, earthing shall be redone by the contractor at no extra cost to the department.
Dismantling and removing existing unsv street light/ flood light MH/HPSV fittings of any type and any capacity from street light poles any hieght and high mast light pole after disconnecteing of electrical connection complete all as specified and directed.
Supply and Fixing, connecting and testing energy saving LED street light fittings 35 Watt with thermal management, potted driver, pressure die cast housing LM 6 alloy/anti dust exposed lens, in built tilt angle arrangement and environment friendly long life with IP66 protection on existing street light poles and bracket complete all as specified and directed.
Supply and Fixing, connecting and testing energy saving LED street light fittings 45 Watt with thermal management, potted driver, pressure die cast housing LM 6 alloy/anti dust exposed lens, in built tilt angle arrangement and environment friendly long life with IP66 protection on existing street light poles and bracket complete all as specified and directed.
Supply and Fixing, connecting and testing energy saving LED street light fittings of 60 Watt with thermal management, potted driver, pressure die cast housing LM 6 alloy/anti dust exposed lens, in built tilt angle arrangement and environment friendly long life with IP66 protection on existing street light poles and bracket complete all as specified and directed.
Supply and Fixing, connecting and testing energy saving LED street light fittings of 120 Watt with thermal management, potted driver, pressure die cast housing LM 6 alloy/anti dust exposed lens, in built tilt angle arrangement and environment friendly long life with IP66 protection on existing street light poles and bracket complete all as specified and directed.
Supply and Fixing, connecting and testing energy saving LED street light fittings of 90 Watt with thermal management, potted driver, pressure die cast housing LM 6 alloy/anti dust exposed lens, in built tilt angle arrangement and environment friendly long life with IP66 protection on existing street light poles and bracket complete all as specified and directed.
Fixing in replacement GI bracket for street light fittings fabricated with GI tubing 40mm dia 'light grade' 1.5m long and bending to angle of 120 degree including mild steel clamp of suitable size with two coat aluminium paint suitable for fixing on PCC/steel poles complete all as specified and directed.
Supply and Fixing, connecting and testing energy efficient LED flood light fittings of 120 Watt pressure die cast aluminium housing and IP66 protection including XLPE armoured cable 2 core 4 Sqmm up to 5 mtr from fitting to panel box with emitter complete all as specified and directed.
Supply and Fixing, connecting and testing energy efficient LED flood light fittings of 70 Watt pressure die cast aluminium housing and IP66 protection including XLPE armoured cable 2 core 4 Sqmm up to 5 mtr from fitting to panel box with emitter complete all as specified and directed.
Supply and Fixing, connecting and testing energy efficient LED flood light fittings of 150 Watt pressure die cast aluminium housing and IP66 protection including XLPE armoured cable 2 core 4 Sqmm up to 5 mtr from fitting to panel box with emitter complete all as specified and directed.
Lowering the high mast light , height of 25 mtr and repairs to the extent by removing connections from the system, checking of unserviceable spare parts and serviceable parts ,replacement of unserviceable parts with new spares and testing complete, tightening the loose connection and made item functional, reassembling the fitting and re-fixing/ re-hanging the same after repair in existing location and tesing complete all as specified and directed. Note : (a) Spares required for repair shall be measured and paid separately as supply only items here-in-after (b) The contractor shall provide all type and safety equipment & other tools required at site to electrician for maintenance of light (c) In case any accident/injury of any person deputed by contractor shall be held responsible for setting all claims/compensation. (d) all other item also included in the works which not catered in items
Supply only gear box as per existing size, capacity and make, complete all as specified and directed.
Supply only motor as per existing size,capacity and make, complete all as specified and directed.
Supply only controll switch as per existing size, capacity and make, complete all as specified and directed.
Supply, fixing, connecting and testing energy efficient LED flood light fittings of 200 Watt pressure die cast aluminium housing and IP66 protection with complete all as specified and directed.
M/s A.K Construction
M/s Vatsh Raj and co
NEW BHARAT ENGINEERING AND CONSTRUCTION CO
M/S SHIVA CONSTRUCTION
m/s pal associates
Diamond Electric Co.
MTR GROUP & COMPANY
Aawadh associates
stage.html
html • 0.07 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .