Loading…
India Infra Updates on WhatsApp
Join the Tenderkart WhatsApp channel for India Infra Updates
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Status |
|---|---|---|
| 1 | Admitted-Finance 2 284 JANKIPURAM VISTAR LUCKNOW UTTAR PRADESH 226021 | LUCKNOW | UTTAR PRADESH | 226021 | Admitted-Finance |
| 2 | Admitted-Finance | Admitted-Finance |
| 3 | Admitted-Finance 06 DUDHI SONBHADRA 231208 | DUDHI | SONBHADRA | UTTAR PRADESH | 231208 | Admitted-Finance |
Tender Value
₹5 L
EMD Value
₹10,000
Closing Date
25 Jun 2024, 10:30 amClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Superintending Engineer (E) UPAVP Lucknow
Office of the Superintending Engineer (E) UPAVP Lucknow
Modification/Alteration of D.G. Supply Selection System in Everest Encalve at Sector-18 Vrindavan Yojna No.4 Phase-II, Lucknow.
2024_UPHDB_928689_1
456/ M-6 ED-I/ 65 Dt. 07.06.2024
Open Tender
Electrical Works
Item Rate
30 days
Vrindavan Yojna No.4 Lucknow
Please refer Tender documents.
3 documents required · 3 mandatory
₹590
Executive Engineer ED-1 UPAVP Lucknow
₹10,000
27 Jun 2024
14 Jun 2024
25 Jun 2024
14 Jun 2024
25 Jun 2024
14 Jun 2024
Amount
Supply, Installation,Testing & Commissioning of L.T. Switch Gear Panels for 433 V, 3 Phase, 4 Wire, 50 Hz Power distribution system. The Panel shall be outdoor (IP:55) degree of protection as per IS 8623, free standing, floor mounting, sheet metal clad, cubicle, dead front, dust and vermin proof type compartmentalised design fabricated out of 14 SWG CRCA steel sheet, complete with colour coded, heat shrinkable PVC insulated, Aluminium Bus Bars and separate earth bus bar of adequate cross section through out the length of the panel. The incoming and outgoing feeders shall be accommodated in a fully segregated, modular multitier arrangement with adequate size and distinct cable alley, bus bar alley/chamber. The Panel shall be complete with name plate, earthing, numbering, danger plate etc. as required and as per specifications and drawings. The Panel shall withstand the fault level of 25 KA.
Outdoor L.T Panel-1
02 Nos. Incoming 400 A 35 KA FP MCCB with extended RHOM along with O/C & S/C Protection along with key Interlock complete with control MCB, wiring etc.
01 No. Bus coupler 400 A 35 KA FP MCCB with extended RHOM along with O/C & S/C protection along with Key Interlock & Mechanical Interlocking as per System Requirement.
02 Nos. Outgoing 400 A 25 KA TPN Bus Bar link only with phase Indicating control MCB, wiring etc.
01 No. Interlinking 400 A 35 KA FP MCCB with extended RHOM along with O/C & S/C Protection along with Key Interlock & Mechanical Interlocking as per System requirement.
Outdoor L.T Panel-2
02 Nos. Incoming 400 A 35 KA FP MCCB with extended RHOM along with O/C & S/C Protection along with key Interlock complete with control MCB, wiring etc.
01 No. Bus coupler 400 A 35 KA FP MCCB with extended RHOM along with O/C & S/C protection along with Key Interlock & Mechanical Interlocking as per System Requirement.
02 Nos. Outgoing 400 A 25 KA TPN Bus Bar link only with phase Indicating control MCB, wiring etc.
01 No. Interlinking 400 A 25 KA TPN Bus Bar Link
Supply & Laying of 400 Sqmm 3.5 Core Al. Conductor PVC Insulated armoured served sheathed cable 1100 Volt grade at a depth of 750mm below ground level over a cushion of 75mm thick sand all around and protected with burnt bricks on sides and on top. On surface the cable run shall be fixed on M.S Clamps etc. of suitable size or as directed by the E/I. complete in all respect. The armouring of the cable shall be properly connected with the earth conductor by clamps complete in all respect as per Direction of E/I.
Supply and fixing of following size palm or pin copper tin plated cable socket (lugs) to the cable leads insulating with tape and making connections etc. complete in all respect as per Direction of E/I.
Supply and fixing of 400 Sqmm 3.5 Core brass nickle plated compression gland for PVC insulated & armoured served sheathed, underground cable including rubber ring etc. complete in all respect. The armouribg of the cable shall be properly connected with the earth complete in all respect as per Direction of E/I.
Supply and Burring of Safe Earthing Electrode T-39 Zn-Zinc Coated, Length 3000 mm, outer pipe 76.30 mm x 3.2 mm inner pipe 42.40 mm x 2.6, terminal Dia 12 mm, coating 80-100 micron filled with crystalline conductive mixture (CCM) having anti corrosive & conductive property with 50 kgs activated soil (BFC) capable of reducing the soil resistivity with good mixture of retaining capacity along with 30 cm square CI frame with hinged cover & masonary housing. Make as approved in UPPWD & CPRI Certified
M/S PREETI ELECTRIC WORKS
Actech Engineers
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .