Loading…
Loading…
| # | Company | Offered Item | Amount | Rank | Status |
|---|---|---|---|---|---|
| 1 | L1₹69,554Qualified Make: Meditec
Model: Make: Meditec International England Ltd. & Model: E-402 203 SWASTIK BHAWAN COMMERCIAL COMPLEX CENTRAL DELHI RANJEET NAGAR CENTRAL DELHI DELHI 110008 | WEST DELHI | DELHI | 110008 | Make: Meditec
Model: Make: Meditec International England Ltd. & Model: E-402 | L1 | Qualified | |
| 2 | L2₹72,000+₹2,446 (3.52%)Qualified Make: BPL
Model: 7108 161 FIRST FLOOR BATA BUILDING HALL BAZAR AMRITSAR CITY PUNJAB 143001 | AMRITSAR | PUNJAB | 143001 | Make: BPL
Model: 7108 | L2 | Qualified | |
| 3 | L3₹80,000+₹10,446 (15.0%)Qualified Make: Contec
Model: Contec ECG 300G A 38 1ST FLOOR NARAINA INDUSTRIAL AREA PHASE 1 NARAINA INDUSTRIAL AREA PHASE 1 SOUTH WEST DELHI DELHI 110028 | NEW DELHI | DELHI | 110028 | Make: Contec
Model: Contec ECG 300G | L3 | Qualified | |
| 4 | L4₹84,000+₹14,446 (20.8%)Qualified Make: RISIAN
Model: RISIAN GW 3EC L 15 PLOT NO 206 SHRISTI COMPLEX RAM GOPAL MAHESHWARI MARG ZONE 1 M P NAGAR BHOPAL MADHYA PRADESH 462011 | BHOPAL | MADHYA PRADESH | 462011 | Make: RISIAN
Model: RISIAN GW 3EC | L4 | Qualified | |
| 5 | L4₹84,000+₹14,446 (20.8%)Qualified Make: Contec
Model: CONTEC 3 CHANNEL ECG MACHINE-300G 0 NEAR MANGAL HOTEL POLICE STATION AMIN PARA PURANI BASTI RAIPUR CHHATTISGARH 492001 | RAIPUR | CHHATTISGARH | 492001 | Make: Contec
Model: CONTEC 3 CHANNEL ECG MACHINE-300G | L4 | Qualified |
Tender Value
Refer Docs
EMD Value
Exempted
Closing Date
16 Aug 2018, 11:00 amClosed
electrocardiography ekg/ecg units Electrocardiography Ekg/ecg Units ( 2 ) Technical Specifications Specification Specification Name Values Allowed Values FEATURES Mobility
portability Protective splashproof case for clean storage and safe transport - Heart rate measurement range to be at least 30 to 250 bpm
with accuracy better than ± 5 bpm yes - Heart rate trend display of at least previous 24 hours yes - In built Software and/or standard of communication yes - Heat Dissipiation: Should maitain nominal Temp and the heat should be disbursed through a exhaust cooling fan yes - User interface manual - Noise Lavel (dba) - - Electrical protection provided by fuses in both live and neutral yes - 1/4 supply lines Operating condition: Capable of operating continuously in ambient temperature of 0 to 50 deg C and relative humidity of 15 to 90% in ideal circumstances yes - Arrhythmia detection facility required; minimum gradation of 1 bpm yes - Functional requirements: electricity;AC-powered; bedside device designed to continuously detect
measure
and display a patient’s electrocardiogram through leads and sensors attached to the patient
it also typically display heart rate
the device is typically equipped with audible and/or visual alarms that are triggered when the patien's parameters drop below or exceed pre-set limits: Continuous display of patient ECG and heart rate on screen
Allows display of single
5 lead ECG or simultaneous display of at least 5 waves selected from up to 12 points Operator can set audiovisual alarm levels for low or high heart rate Operates from mains voltage or from internal rechargeable battery yes - Power consumption - - weight - - Power cable length (meter) 3 METER OR MORE - Display must allow easy viewing in all yes - 2/4 ambient light levels Audiovisual alarms required: high and low heart rate; operator variable settings
cardiac arrhythmia
sensor/wire disconnected
low battery yes - STANDARDS AND SAFETY
CERTIFICATIONS Certification(s) CE Approved product - MISCLANEOUS Warranty (years) 3 3
5 Higher is better power input and frequency 220 To 240V
50 Hz AC - Certificate of Calibration and Inspection to be provided YES - * Bold specifications are the golden parameters. Consignees and Quantity S.No. Consignee Address Quantity Delivery Days 1 Ramudu Rongali 482021
29TH BN ITBP JAMTARA CAMP PO GOUR NADI DISTRICT JABALPUR MADHYAPRADESH 2 15
468343
GEM/2018/B/66205
electrocardiography ekg/ecg units
15 days
Madhya Pradesh; Jabalpur
PRODUCT
| Item | Delivery Location | Qty | Delivery |
|---|---|---|---|
| electrocardiography ekg/ecg units Electrocardiography Ekg/ecg Units ( 2 ) Technical Specifications Specification Specification Name Values Allowed Values FEATURES Mobility | - | - | - |
| portability Protective splashproof case for clean storage and safe transport - Heart rate measurement range to be at least 30 to 250 bpm | - | - | - |
| with accuracy better than ± 5 bpm yes - Heart rate trend display of at least previous 24 hours yes - In built Software and/or standard of communication yes - Heat Dissipiation: Should maitain nominal Temp and the heat should be disbursed through a exhaust cooling fan yes - User interface manual - Noise Lavel (dba) - - Electrical protection provided by fuses in both live and neutral yes - 1/4 supply lines Operating condition: Capable of operating continuously in ambient temperature of 0 to 50 deg C and relative humidity of 15 to 90% in ideal circumstances yes - Arrhythmia detection facility required; minimum gradation of 1 bpm yes - Functional requirements: electricity;AC-powered; bedside device designed to continuously detect | - | - | - |
| measure | - | - | - |
| and display a patient’s electrocardiogram through leads and sensors attached to the patient | - | - | - |
| it also typically display heart rate | - | - | - |
| the device is typically equipped with audible and/or visual alarms that are triggered when the patien's parameters drop below or exceed pre-set limits: Continuous display of patient ECG and heart rate on screen | - | - | - |
| Allows display of single | - | - | - |
| 5 lead ECG or simultaneous display of at least 5 waves selected from up to 12 points Operator can set audiovisual alarm levels for low or high heart rate Operates from mains voltage or from internal rechargeable battery yes - Power consumption - - weight - - Power cable length (meter) 3 METER OR MORE - Display must allow easy viewing in all yes - 2/4 ambient light levels Audiovisual alarms required: high and low heart rate; operator variable settings | - | - | - |
| cardiac arrhythmia | - | - | - |
| sensor/wire disconnected | - | - | - |
| low battery yes - STANDARDS AND SAFETY | - | - | - |
| CERTIFICATIONS Certification(s) CE Approved product - MISCLANEOUS Warranty (years) 3 3 | - | - | - |
| 5 Higher is better power input and frequency 220 To 240V | - | - | - |
| 50 Hz AC - Certificate of Calibration and Inspection to be provided YES - * Bold specifications are the golden parameters. Consignees and Quantity S.No. Consignee Address Quantity Delivery Days 1 Ramudu Rongali 482021 | - | - | - |
| 29TH BN ITBP JAMTARA CAMP PO GOUR NADI DISTRICT JABALPUR MADHYAPRADESH 2 15 | - | - | - |
Exempted
16 Aug 2018
11 Aug 2018
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
bid_468343.pdf
GEM_BID
termsCondition.pdf
OTHER
2657c7ca70287299b5181580fdb5a7ab.pdf
OTHER
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .