| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹26.8 LAccepted-AOC SHOP NO 10 BMC SHOPPING CENTRE MITHA NAGAR GOREGAON WEST MUMBAI 400 104 | MUMBAI | MUMBAI SUBURBAN | MAHARASHTRA | 400104 | L1 | Accepted-AOC Being Lowest | |
| 2 | L2₹37.4 L+₹10.1 L (37.1%)Rejected-Finance | L2 | Rejected-Finance Being other than lowest | |
| 3 | L3₹46.2 L+₹18.9 L (69.6%)Rejected-Finance | L3 | Rejected-Finance Being other than lowest |
Tender Value
Refer Docs
EMD Value
₹76,000
Closing Date
6 Jul 2021, 6:00 pmClosed
CWE (NW) Mumbai
Commander Works Engineer NW Dr Homi Bhabha Road Navy Nagar Colaba Mumbai 05
REPLACEMENT OF OLD COOL ROOMS AND COLD ROOM IN PATIENTS GALLEY AND MEDICAL STORES UNDER SPECIAL REPAIRS AT INHS ASVINI UNDER AGE (I) ASVINI COLABA MUMBAI
2021_MES_448284_1
8085/CWE(NW)/MUMBAI
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
AGE (I) Asvini
Class D
7 documents required · 7 mandatory
₹500
Yes
AGE (I) Asvini
₹76,000
Yes
17 Aug 2021
3 Jun 2021
8 Jul 2021
3 Jun 2021
6 Jul 2021
24 Jun 2021
3 Jun 2021 - 23 Jun 2021
Amount
Dismantling of Old Unserviceable SS racks and Supply and Fixing for Cold Room SS 304 Racks for suitable size/width/height in all three sides for each cold rooms as per site requirement complete all as specified and as directed by Engr-in- Charge.
Supply, installation, testing and commissioning of Solenoid Valve 5/8", including Takingdown Old Unserviceable, complete all as specified and as directed by Engr-in- Charge.
Supply, installation, testing and commissioning of Solenoid Valve 3/8", including Takingdown Old Unserviceable, complete all as specified and as directed by Engr-in- Charge.
Supply, installation, testing and commissioning of control panel cum sequence operation controller for Freezer Room Units, including associated control & power wiring in PVC conduit, etc. The controller shall perform mainly the following function. To run only required set of unit. (One unit shall remain standby during normal operation.) To give & log alarm when running units fail or show an error. To auto set timer/ Start stop, for operation of each unit to maintain equal run hour To start standby when temperature rises above set point. To start standby unit incase of breakdown fault or on temperature rise of space complete all as specified and as directed by Engr-in- Charge. Note: Sequence controller shall be suitable to control two units (1 working + 1 standby) , incuding Takingdown Old Unserviceable, complete all as directed by Engr-in-Charge.
Supply, installation, testing and commissioning of control panel cum sequence operation controller for Dairy/F&V/Pharma Chiller Room Units, including associated control & power wiring in PVC conduit, etc. The controller shall perform mainly the following function. To run only required set of unit. (One unit shall remain standby during normal operation.) To give & log alarm when running units fail or show an error. To auto set timer/ Start stop, for operation of each unit to maintain equal run hour To start standby when temperature rises above set point. To start standby unit incase of breakdown fault or on temperature rise of space complete all as specified and as directed. Note: Sequence controller shall be suitable to control two units (1 working + 1 standby), incuding Takingdown Old Unserviceable, complete all as directed by Engr-in-Charge.
Supply, installation, testing and commissioning of Insulated Refrigerant pipe size upto 25mm dia between IDU & ODU for Freezer room/Dairy/F& V/Pharma Chiller room refrigerant units. The refrigerant pipes shall not be less than 20 gauge thickness. and all associated work and accessories required to complete the work with additional refrigerant charge if required, including support clamps, rods, bolts, nuts, washers, fastners, etc complete all as specified and as directed.
Supply & Filling, testing and commissioning of for Refrigerant Gas R404a.
Supply, installation, testing and commissioning of TPN DB-VTPN, DPX3 MCCB DBs 4 Way to provide power supply of the Freezer & Chillers Room ODU units, (DPX3 160+12) suitable for flush mounting and surface mounting, conforming to IP 43 & IP 54 - IK 09 with prefitted masking sheet with 250 Amp copper bus bar for each phase, complete with 2 Neutral bar and 2 Earthing bar and cable ties for cable management, provision for DPX3 upto 160 MCCB as incomer and SP/TP MCBs as outgoing as per IEC 61439-3, takingdown the old unserviceable TPN DBs, connection complete and making good the disturbed surfaces complete all as specified and as directed by Engr-in- Charge. Make:- Legrand cat part No. 507750 or Equivalent Havells/L&T/ C&S Electric Ltd/ABB or equivalent as approved by GE.
Supply and fixing for MCB TPN DX3, 415 Volt, 63 Amp, 10 KA, IP 20 Protected terminals, Complete all as specified and as directed. Make:- Legrand cat part No. 408683 or Equivalent Havells/L&T /C&S Electric Ltd/ABB or equivalent as approved by GE.
Material and labour for MCCB 4 Pole, 415 V, Thermal magnetic adjustable type, 160 Amps with breaking capacity 25 KA, complete all as specified and as directed by Engr-in- Charge. Make:- Legrand cat part No. 420057 or Equivalent Havells/L&T /C&S Electric Ltd/ABB or equivalent as approved by GE.
Dismantling/Takingdown old trays and Supply & Installation of Hot Dip Galvanised GI Cable tray 300mm with 50mm collar height of 16 SWG thickness With Cover suitable for laying refrigerant pipes and Power & control cables, including support clamps, rods, bolts, nuts, washers, fastners, etc complete all as specified and as directed by Engr-in- Charge.
Takingdown old U/s LED Fittings and S & F for LED Surface 1 x 1 Feet , 18 Watts, Polaris IV is a exquisitely designed luminaire which is bound to deliver extra ordinary lumens through its pure from nd glare-less light ,complete all as specified and as directed by Engr-in- Charge. Make: - Crompton cat part no. LCTLRN -18-CDL or Equivalent Phillips/Wipro or equivalent as approved by GE.
Takingdown old U/s switch and Supply & Fixing for 5 Man Insert Alarm with weatherproof Switch suitable for chiller and cold room complete all as specified and as directed by Engr-in- Charge.
Takingdown old U/s DB enclosure and Supply & Fixing for MCB DBs 4 Module weather proof cabinets fully reversible, suitable for flush mounting and surface mounting, conforming to IP-65 -IK 09-class-II, confirming to EN 60439-3, 2-position rail for modular products and moduled cases with isolators upto 63Amps TPN, with all accessories, connection complete and making good the disturbed surfaces complete all as specified and as directed by Engr-in- Charge. Make:- Legrand Plexo3 boxes for DX cat part No. 601994 or Equivalent Havells/L&T/ C&S Electric Ltd/ABB.
Takingdown old drain pipe and Supply & Fixing for insulated drain pipe size up to 40 mm dia for Freezer room Units, including support clamps, rods, bolts, nuts, washers, fastners, etc complete all as specified and as directed by Engr-in- Charge.
Takingdown old drain pipe and Supply & Fixing for insulated drain pipe size upto 40mm dia for Chiller room Units, including support clamps, rods, bolts, nuts, washers, fastners, etc complete all as specified and as directed by Engr-in- Charge.
Material and labour for PVC insulated unsheathed FRLS copper conductor 1100 volt grade multistandard of size 1.0 sqmm x 2 core and incl drawn through PVC casing capping/PVC Conduit 25x12mm/32x12mm including all accesssories (ISI marks) complete all as specified and as directed.
Material and labour for PVC insulated unsheathed FRLS copper conductor 1100 volt grade multistandard of size 1.5sqmm x 3 core and incl drawn through PVC casing capping/PVC Conduit 25x12mm/32x12mm including all accesssories (ISI marks) complete all as specified and as directed by Engr-in- Charge.
Material and labour for PVC insulated unsheathed FRLS copper conductor 1100 volt grade multistandard of size 1.5sqmm x 4 core and incl drawn through PVC casing capping/PVC Conduit 25x12mm/32x12mm including all accesssories (ISI marks) complete all as specified and as directed by Engr-in- Charge. (Evap Fan)
Material and labour for PVC insulated unsheathed FRLS copper conductor 1100 volt grade multistandard of size 1.0 sqmm x 6 core and incl drawn through PVC casing capping/PVC Conduit 25x12mm/32x12mm including all accesssories (ISI marks) complete all as specified and as directed by Engr-in- Charge. (LP HP OP Controller)
Material and labour for PVC insulated unsheathed FRLS copper conductor 1100 volt grade multistandard shielded (armoured) of size 1.0 sqmm x 3 core and incl drawn through PVC casing capping/PVC Conduit 25x12mm/32x12mm including all accesssories (ISI marks) complete all as specified and as directed by Engr-in- Charge. (Sensor)
Material and labour for PVC insulated unsheathed FRLS copper conductor 1100 volt grade multistandard of size 2.5 sqmm x 4 core and incl drawn through PVC casing capping/PVC Conduit 25x12mm/32x12mm including all accesssories (ISI marks) complete all as specified and as directed by Engr-in- Charge. (Defrost/Electrical panel to CDU)
Material and labour steel structural fabrication works fabricated from structural steel sections including nuts, bolts,washers, welding ,bending cold or hot, drilling holes for bolts, in any shape or size as indicated or directed and inclusive of one primary coat, one under coat and one finishing coat of paint
HVAC Engineering Co
somnath engineering corporation
stage.html
html • 0.05 MB
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .