| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹44.0 LAccepted-AOC N A | FARIDABAD | HARYANA | 121004 | L1 | Accepted-AOC L1 Bidder | |
| 2 | L2₹46.4 L+₹2.2 L (5.03%)Rejected-Finance | L2 | Rejected-Finance Not Lowest Bidder | |
| 3 | L3₹46.4 L+₹2.3 L (5.19%)Rejected-Finance 30 HAREN MUKHERJEE ROAD HAKIMPARA SILIGURI 734 001 DARIEELING WB | DARJEELING | WEST BENGAL | 734001 | L3 | Rejected-Finance Not Lowest Bidder | |
| 4 | L4₹46.8 L+₹2.6 L (5.95%)Rejected-Finance GEETANJALI COMPLEX B BLOCK 2ND FLOOR MUKUNDA DAS ROAD MILANPALLY SILIGURI 734405 DARJEELING | SILIGURI | DARJEELING | WB | 734405 | L4 | Rejected-Finance Not Lowest Bidder | |
| 5 | L5₹47.1 L+₹3.0 L (6.72%)Rejected-Finance VIVEKANANDAPALLY UPPER BAGDOGRA DIST DARJEELING WB PIN 734 014 | UPPER BAGDOGRA | DARJEELING | WB | 734014 | L5 | Rejected-Finance Not Lowest Bidder |
Tender Value
₹43.2 L
EMD Value
₹86,460
Closing Date
27 Oct 2023, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Garrison Engineer Sukna
Garrison Engineer Sukna, Post-Simulbari, Dist.-Darjeeling, WB-734009
SPL REPAIR TO BLDG NO T 45 (NO 1 TP LINE) AT COY ASC IN SUKNA MIL STN
2023_MES_621716_1
GE Sukna/8587
Open Tender
Civil Works
Works
270 days
Sukna
AS PER TENDER DOCUMENTS
8 documents required · 8 mandatory
₹500
GE Sukna
₹86,460
Yes
5 Dec 2023
5 Oct 2023
28 Oct 2023
5 Oct 2023
27 Oct 2023
20 Oct 2023
6 Oct 2023 - 27 Oct 2023
Amount
Surface excavation not exceeding 30 cm deep and averaging 15 cm deep and getting out in Soft/ Loose soil complete all as specified and directed.
Excavation over areas not exceeding 1.5 M deep and getting out in Soft/ Loose Soil complete all as specified and directed.
Excavation over areas exceeding 1.5 M and not exceeding 3 M deep and getting out in Soft/ Loose Soil complete all as specified and directed.
Excavation over areas exceeding 3 M and not exceeding 4.5 M deep and getting out in Soft/ Loose Soil complete all as specified and directed.
Excavation in trenches not exc. 1.50 m wide and not exc. 1.50 m in depth; for foundation, etc. or for shafts, wells, cesspits, manholes, pier holes, etc. not exc. 10 Sqm on plan and getting out in soft / loose soil complete all as specified and directed.
Returning, filling in, including spreading, levelling, watering and well ramming in layers not exceeding 25 cm thick with soils complete all as specified and directed.
M&L for filling the gaps at the junction of roof sheet and vertical wall any thickness, any position and on height upto 10m from G.L using cement concrete type C1, 1:3:6 (using 20mm graded aggregate) and finish both side of wall by 15 mm rendering in cement mortar 1:6 and applying two coats of cement base paint to match with existing surface to match including necessary scaffolding complete all as specified and directed.
M & L for Sand filling under floors or in foundations including watering and consolidation complete all as specified and directed. (Note :- Consolidated thickness shall only be measured and paid).
Removing Excavated soils not exc 50 M and depositing where directed at a level not exc1.5 M above the starting point complete all as specified and directed.
M&L loose filling with aggregates of gauge 80 to 150 mm in soakage pits, soakage wells using broken bricks complete all as specified and directed.
M & L for Hardcore of gauge not exc. 63 mm, deposited, spread and leveled in layers not exc. 15 cm thick, watered and rammed to a true surface using broken stone or boulders complete all as specified and directed.
M&L for Plain Cement Concrete Type D2 1:4:8 (using 40 mm graded stone aggregate) in foundations, filling and mass concrete complete all as specified and directed.
M&L for PCC Type B1 1:2:4 (using 20 mm graded stone aggregate) as in copings, kneelers, apex stones and bed plates water trough and the like including weatherings slightly rounded chamfered angles and throating etc complete all as specified and directed.
M&L for Plain Cement Concrete Type C1 1:3:6 (using 20 mm graded stone aggregate) as in kerbs for sides of drain, water troughs and the including wethering, slightly rounded or chamfered angles and throating and including formwork straight of cuved complete all as specified and directed.
M&L providing PCC 1:2:4 type B1, (using 20 mm graded crushed stone aggregate) as in lintels upto 1.5 m clear span, cills, steps; seismic and other similar bands, plinth courses, string courses, lacing courses, parapets and railings upto 60 cm in height, copings, benching, kneelers, apex stones, bed plates, kerbs, water troughs and the like including weathering, slightly rounded or chamfered angles and throating and including necessary formwork complete all as specified and directed.
M&L for PCC 1:2:4 type B-0 (using 12.5 mm graded stone aggregate) forming fair finish as in surface channel and drain complete all as specified and directed.
M&L for Precast cement concrete 1:2:4, type B1 (Using 20 mm graded stone aggregate) in landings, cover slabs (for Manholes etc.) shelves and similar articles with plain faces and set in cement mortar 1:4 complete all as specified and directed.
M&L for Reinforced Cement Concrete Type B-1 1:2:4 (using 20 mm graded stone aggregate) in slabs supported on walls, beams and columns in floors, roofs, landings, balconies, deck slabs and in shelves and the like complete all as specified and directed.
Supply only liquid water proofing compound ISI mark.
M & L for brick work with sub class ‘B’ old size bricks straight or curved on plan n.exc. 6.00 m mean radius built in cement mortar 1:6 complete all as specified and directed.
M&L for Brick work with sub-class `B' bricks, straight or curved on plan to any radius in half brick thick wall built in cement mortar 1:4 complete all as specified and directed.
M & L for brick work with sub class ‘B’ old size bricks in one brick thick honey-comb wall built in cement mortar 1:4 complete all as specified and directed.
M&L for rough finished flat form work to soffits of suspended slabs such as roof slabs, floor slabs and similar work not exc. 200 mm thick (horizontal or sloping) work as rough finished surfaces of concrete complete all as specified and directed.
S&F 30mm thick flush shutters, solid core construction, with MDF board and both face is covered with decorative face veneer with 6mm thick teak wood lipping/frame to match all as specified and directed
Taking down chowkhats or frames area not exc. 1.50 Sqm each with shutters (without taking off shutters from the frames) complete all as specified and directed.
Taking down chowkhats or frames area exc. 1.50 Sqm but not exc. 4.00 Sqm each with shutters (without taking off shutters from the frames) complete all as specified and directed.
S&F Factory made solid panel PVC door shutter 30 mm thick (style) consisting of frame made out of mild steel tubes for top & bottom rails, mild steel frame shall be covered with heat moulded plain colour PVC ‘C’ channel having a PVC sheet strip of 20mm width stuck inside with solvent cement for stiles and plain colour PVC sheets for top rail, lock rail & bottom rail on either side & as gap insert for top rail & bottom rail, Panelling of wire gauze in lieu of plain colour PVC sheet. The wire gauze shall be wrapped on an additional square 8mm MS Solid tube and this tube shall be welded to MS tubes. The wire gauge shall be stretched to tighten firmly, suppling & fixing in the frame at site as per specification & drawing as per specification and drawing given on MES schedule Part – II (2010) complete all as specified and directed.
S&F 150mm long aluminium anodized barrel tower bolts of extruded section complete all as specified and directed.
Supply and fix 300 mm long Aluminium alloy, anodised, sliding door bolt with hasp, staple (bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of extruded sections or cast Aluminium alloy complete all as specified and directed.
S & F 125 mm long medium weight, cold rolled mild steel Butt hinges with screws complete all as specified and directed.
S & F 300 mm long ordinary rat tail pattern springs including roller and roller plate complete all as specified and directed.
S&F 150 mm Aluminium handles cast type, anodised and fixed complete all as specified and directed.
S&F in repairs decorative mild steel 20mm curtain rod of chromium plated with & including suitable CP brackets, stops, rollers etc complete all as specified and directed.
S & F Floor door stopper of Aluminium alloy body and tongue, anodised, with hard drawn steel spring, fixed in floor, Overall length of cover plate 140 mm complete all as specified and directed.
S & F stainless steel wire cloth 0.36 mm nominal dia of wire and average width of aperture 1.40 mm and fixed with tinned stacks, or stainless steel wire staples complete all as specified and directed.
M&L for Mild steel TMT bars 10 mm dia., and over cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with mild steel wire (annealed) not less than 0.9 mm dia., or securing with clips complete all as specified and directed.
M&L for Mild TMT bars 6 mm to 8 mm dia., cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with mild steel wire (annealed) not less than 0.9 mm dia., or securing with clips complete all as specified and directed.
S&F rolled mild steel in plates, gusset plate (plain or chequered) channels square cut or notched (ordinary and counter sunk) forming holes, with riveted, bolted or welded attachment conforming to Fe-410W (Gde-E-250) quality-A complete all as specified and directed.
S & F Roof truss (framed) trussed, purlins,crane gantires of steel work as in tubular trusses including special shaped washers etc. complete using ERW or induction butt welded tubes conforming to IS – 1161 – 1998 grade St – 240 complete all as specified and directed.
S & F Steel windows with side hung shutters including box type hinges with steel handle and steel peg stay, complete with glazing bars, dovetailed or welded complete all as specified and directed.
S & F Steel windows with side hung shutters including box type hinges with steel handle and steel peg stay, complete without glazing bars, dovetailed or welded complete all as specified and directed.
S & F of pressed steel frame of size 125 X 60 mm for doors with one or more rebates including necessary fixing lugs, hinges, lock strike plates etc complete all as specified and directed.
S&F pre-painted galvalume aluminum zinc coating GI based corrugated steel sheet 0.50 mm TCT (total coated thickness) of any colour having tensile strength of 550 Mpa as in roof covering cladding to wall etc, fixed with self tapping screws complete all as specified and directed.
S&F pre-painted galvalume aluminum zinc coating GI based plain steel sheet 0.50 mm TCT (total coated thickness) of any colour having tensile strength of 550 Mpa as in roof covering cladding to wall etc, fixed with self tapping screws complete all as specified and directed.
S&F in replacement 4 mm thick pre-painted E-fibre board Designer/Decorative fixed or laid/ inserted to with and including Anodised aluminium snap grid frame size 605x605 mm work for false ceiling Hangers with 6 mm dia. G.I. (length as required) adjusting level fixed to roof slabs/truss by means of ceilling cleats made out of G.I. flat 40 x 3 mm size 60mm long and expansion hold fasteners 12.5mm dia 40mm long including necessary dimantling of existing unserviceable ceiling boards of any thickness including cover fillets complete all as specified and directed.
M&L 75 mm thick, PCC 1:3:6, type C-2, (using 40 mm graded crushed stone aggregate) as in plinth protection, hardstanding, floors, paths, etc, finished even and smooth without using extra cement complete all as specified and directed.
M&L for 100 mm thick cement concrete, type D 2, 1:4:8 (using 40 mm graded stone aggregate) in sub base of flooring finished rough to receive finishes complete all as specified and directed.
M&L coloured glazed ceramic tiles 300x450x7 mm thick as in dado / skirting and vertical surfaces, set and jointed in neat cement slurry and pointed in white or coloured cement to match laid over and including 10 mm thick screed bed in CM 1:4 including dismantling of wall tiles complete all as specified and directed.
M&L Non Skid ceramic coloured tiles 7 to 8 mm thick (square / rectangular) area of each tile exc. 0.11 sqm but n. exc. 0.18 sqm, in floor etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match laid over and including screed bed 15 mm thick in CM 1:6 and dismantling complete all as specified and directed.
M&L for Machine pressed precast concrete interlocking coloured paver block any shape and size confirming to IS 15658-2006 of 60 mm thickness, M-35 Grade with gray cement pigment complete all as specified and directed.
M&L cement concrete chequered tiles 300 x 300 x 25 mm thick as in floors, set and jointed over and including 15 mm thick screed bed in CM 1:6 and pointed in grey cement and pigments to match the colour of tile complete all as specified and directed.
M&L for rendering 15 mm thick on fair faces of brick work or concrete surfaces in cement mortar 1:6 finished even and smooth without using extra cement complete all as specified and directed.
M&L for rendering 15 mm thick on fair faces of brick work or concrete surfaces in cement mortar 1:4 finished even and smooth without using extra cement complete all as specified and directed. (WPC will be measured and paid separately)
Taking down cement plaster on brick or concrete surfaces / ceiling, racking out joints hacking for key scrubbing down with water etc complete all as specified and directed.
M & L for preparation of newly plastered or previously untreated surfaces of walls and applying two coats of oil bound distemper over a coat of primer and over a thin layer of wall care putty to obtain smooth finish complete all as specified and directed.
M&L preparation of new plastered wall surfaces and including applying two coats of cement base paint over a coat of cement primer complete all as specified and directed.
S & F Sheet glass 3.0 mm thick, ordinary quality and glazing with oil putty or wooden beads not exceeding 0.5 Sqm in each pane glazed with putty or fixed with beads complete all as specified and directed.
M&L preparation of new wooden surfaces of any description, not otherwise described over 10 cm width or girth and including applying two coats of synthetic enamel paint over a coat of pink primer complete all as specified and directed.
M&L preparation of new steel surfaces of any description, not otherwise described over 10 cm width or girth and including applying two coats of synthetic enamel paint over a coat of red oxide primer complete all as specified and directed.
M&L preparation of new steel surfaces of any description not exceeding 10 cm width or girth when unconnected with other painting or when painted in a different tint and including applying two coats of synthetic enamel paint over a coat of red oxide primer complete all as specified and directed.
S&F 80 mm bore galvanised steel water tubing medium grade and including necessary GI fitting (such as bends, elbows, tees etc.) and fixed to wall / ceiling or laid in / on floor complete all as specified and directed.
M & L for PCC 1:4:8 type D2 (using 40 mm graded stone aggregate) in concrete bed to drain pipes including packing under and completely surrounding pipes with concrete after they are laid and tested for pipes of 150 mm bore pipe complete all as specified and directed.
M & L 150 mm dia Salt Glazed stone ware drain pipes laid in trenches and jointed in CM 1:1 complete all as specified and directed.
Demolition of brick work or stone/ boulder masonry, built in cement mortar including all quoins, pillars etc. complete all as specified and directed.
Demolition of cement concrete (un-reinforced) in ground floor and paving not exc. 15 cm thick (Below or above ground level) complete all as specified and directed.
Demolition of reinforced cement concrete (reinforcement cut as required to facilitate demolition) of any description and in any position not otherwise specifically provided for complete all as specified and directed.
Dismantling of plain or corrugated steel sheeting, any gauge, thickness including nainital or similar pattern in roof and wall covering omplete all as specified and directed.
E/M PORTION
Taking down copper / aluminium concealed point wiring (light, fan, socket or power) complete, including fixture and fittings such as switches, ceiling roses, pendants, regulators, sockets, light fitting etc., removing materials to store for keeping in safe custody or for taking credit, cutting chasing as required and making good the disturbed surfaces including finishes to match with adjacent surfaces of walls, floors, etc. complete all as specified and as directed.
Taking down copper / aluminium concealed sub main wiring complete with all fixture and fittings including cutting chasing as required and making good the disturbed surfaces including finishes to match with adjacent surfaces of walls, floors, etc. complete all as specified and as directed.
Taking down MCB & DB of any cpacity including MCB / Isolator etc and making good disturbed area complete all as specified and as directed.
M&L point wiring with 1.5 sqmm single core, PVC insulated, unsheathed FRLSH copper cable, 1100 volts grade, with multi stranded copper conductor drawn through and including non-metallic, rigid non mettalic PVC conduit (medium grade) concealed in wall / ceiling with and including 1.5 sqmm single core PVC insulated, multistranded, unsheathed, FRLSH copper conductor cable as continuous earth continuity conductor (green in colour) with cast Iron / pressed steel terminal boxes 60 mm deep, on walls with 3 mm thick plastic laminated / hylam sheet cover, fixed on wall / other surfaces with brass screws for mounting or housing switches, socket outlets, fan regulators, etc. including all other fixing accessories for one light / fan / exhaust fan / call bell point controlled by one 5 / 6 Amps switch and including cutting chasing (as required) and making good the disturbed surfaces including finishes to match with adjacent surfaces complete all as specified and directed.
All as per Sl. item No. 72.00 above but for one 5 / 6 Amps socket outlet point on independent board.
All as per Sl. item No. 72.00 above but for one 5 / 6 Amps socket outlet point on same board.
All as per Sl. item No. 72.00 above but for one 16 Amps socket outlet point on independent board with 2.5 sqmm cable and 2.5 sqmm earth wire
M & L concealed sub main wiring with 2 runs of 2.5 sqmm main wire along with 1 run of 2.5 sqmm earth wire (green in colour) single core FRLSH PVC insulated, unsheathed, multi-stranded, 1100 volts grade ISI marked copper conductor cable, drawn through and including adequate size rigid non-metallic PVC conduit (medium grade) with all fittings & accessories including cutting chases for conduits as required, sinking for terminal boxes, making good the disturbed surfaces including finishes to match with adjacent surfaces complete all as specified and directed. NOTE:- Two runs of main copper conductor, one run of earth wire and one run of PVC conduit shall be measured as one unit length.
M & L concealed sub main wiring with 2 runs of 4 sqmm main wire along with 1 run of 4 sqmm earth wire (green in colour) single core FRLSH PVC insulated, unsheathed, multi-stranded, 1100 volts grade ISI marked copper conductor cable, drawn through and including adequate size rigid non-metallic PVC conduit (medium grade) with all fittings & accessories including cutting chases for conduits as required, sinking for terminal boxes, making good the disturbed surfaces including finishes to match with adjacent surfaces complete all as specified and directed. NOTE:- Two runs of main copper conductor, one run of earth wire and one run of PVC conduit shall be measured as one unit length.
M & L concealed sub main wiring with 2 runs of 6 sqmm main wire along with 1 run of 6 sqmm earth wire (green in colour) single core FRLSH PVC insulated, unsheathed, multi-stranded, 1100 volts grade ISI marked copper conductor cable, drawn through and including adequate size rigid non-metallic PVC conduit (medium grade) with all fittings & accessories including cutting chases for conduits as required, sinking for terminal boxes, making good the disturbed surfaces including finishes to match with adjacent surfaces complete all as specified and directed. NOTE:- Two runs of main copper conductor, one run of earth wire and one run of PVC conduit shall be measured as one unit length.
S&F switch piano, single pole, one way, 5 / 6 Amps 240 volt complete all as specified and directed.
S&F switch socket combination 3 pin 15 Amp, flush type universal complete all as specified and directed.
S&F switch socket combination 3 pin 5 Amp, flush type universal complete all as specified and directed.
S&F socket outlet 5 pin 5 / 6 Amps, 240 volts complete all as specified and directed.
S&F ceiling rose, surface bakelite 65 x 50 mm three terminal complete all as specified and directed.
S&F stepped type electronic fan regulator two module, with 5 step, AC 50 Hz 240 Volts grade, 100 W, complete all as specified and directed.
S&F lamp holder, PVC/Polycarbonate type with cord grip cap suitable for pendant fittings complete all as specified and as directed.
S&F MCB SP 6 to 32 Amp, 10 kA, 240V 'C' curve complete all as specified and as directed.
S&F MCB SPN 40 to 63 Amp, 10 kA, 240V 'C' curve complete all as specified and as directed.
S&F MCB DB, SPN 12 way, IP-43, IK 09, Single door type with metal door, recessed in wall surface with 200A copper neutral and earth bus bar for fixing MCB, fixing flush to wall & making good the disturbed surfaces complete all as specified and as directed.
S&F in repairs (in existing point or new point all as directed by the Engr-in-charge) Inverter LED Batten square round profile with the following specification :- (i) Wattage :- 9 to 12 watts (ii) Supply :- 230V, AC, 50Hz (iii) Shape :- Batten fittings square or round profile (iv) Type of cover :- Frosted (v) Nominal life time :- 25,000Hrs (vi) Colour temperature :- 4500-6500k (vii) CRI index :- 80-90 (viii) Battery :- Not less than 2200mAh or not less than 4 hrs backup (ix) Backup time :- Not less than 4Hrs (x) Lumens :- Not less than 900 Lm and on battery not less than 400 lm (xi) Efficacy :- Not less than 80 Lm/Watt
Supply and fix in repair of surface & wall mounted LED tube light fittings 4 feet with 20 w indoor luminaries with and including Electronic driver and LED lamp, pre-wired including necessary electric connection from ceiling rose to light fitting on existing point or new points all as directed by the Engr-in-Charge, conforming to the following specifications: - (i) System Watts/lumens: - 20 W/Total system lumen not less than 2000 Lm. (ii) Housing: - Extruded polycarbonate (iii) IP rating: - IP 20 (iv) Front cover: - Acrylic/polycarbonate / glass cover frosted (v) Mounting: - Suitable for wall/ceiling mounting (vi) Finish: - Smooth finish (vii) Lamp: - High bright LED (viii) System Efficacy (lm/Watt): - Not less than 90 lm/watt (ix) Colour temperature: - Not less than 5700 K (x) Colour rendering index (CRI): - Not less than 80 (xi) Life: - Not less than 25000 hrs of operation (xii) Optics: - Designed for optimum light distribution (xiii) Control gear: - Inbuilt electronic driver with APFC, PF not less than 0.95, and THD not more than 20% of the standard operating voltage 180-270V Ac, 50 Hz (xiv) Surge protection: - Inbuilt surge protection minimum 2 KV (xv) Heat sink: - As per OEM's design
S&F in repairs surface & wall mounted LED Bldg Security light fittings with 20w outdoor luminaries with and including Electronic driver and LED lamp, pre-wired including necessary electric connection from ceiling rose to light fitting, conforming to the following specifications:- (i) System watts/lumens :- 30 W / Total system lumen not less than 3000 lm (ii) Hosuing :- Pressure Die casting (iii) IP rating :- IP 65 (iv) Front cover :- Acrylic / Polycarbonate / Glass cover (v) Mounting :- Suitable for wall / ceiling mounting (vi) Finish :- Smooth finish (vii) Lamp :- High bright LED (viii) System Efficacy (Im/Watt) :- Not less than 100 lm/watt. (ix) Colour temperature :- Not less than 5700k (x) Colour rendering index (CRI) :- Not less than 80 (xi) Life :- Not less than 25000hrs of operation (xii) Optics :- Designed for optimum light distribution with curve diffuser (xiii) Control gear :- Inbuilt electronic driver with APFC, PF not less than 0.95, and THD not more than 20% of the standard operating voltage 180-270V AC, 50Hz (xiv) Surge Protection :- Inbuilt surge protection minimum 2KV (xv) Heat sink :- As per OEM's design
Supply and fix in repair of energy saving BLDC ceiling fan complete with all connected accessories as specified below: - Input Power: - 26 watts with full speed and reduced power consumption with reduced speed technology. Voltage: - 90-300 V AC, 50Hz, single Phase. RPM: - 340 to 375 rpm Blades: - Decorated Sweep: - 1200 mm. Air delivery: - Not less than 210 CFM Colour: - Glow white/Toast Brown/Gloss Black/or others as approved by Engr-in-Charge Speed/power control: -Without Remote through existing regulator. Star rating: - BEE 5 Star Rating Warranty: - As specified by the manufacturer, contractor shall produce original warranty and test certificate from the manufacturer.
S&F in repairs exhaust fan 250 mm sweep, non metallic plastic body, AC single phase, 230 V, 50Hz with & including self closing louvers, nuts, screws, bolts of specified sizes, electrical connection with twisted three core PVC insulated unsheathed flexible cord of size 0.75 sqmm copper conductor from ceiling rose to exhaust fan and writing MES number in 2 cm height with synthetic enamel paint complete all as specified and as directed. Note :- (The quoted rate is including for taking down and depositing old fan to MES store).
M &L of Earthing with galvanised steel earth plate electrode 600 mm x 600 mm x 6 mm thick, buried directly and preferably vertically in ground, earth pit not less than 2.25 Mtr deep below ground level with top edge of the plate not less than 1.5 Mtr below ground level connected using galvanised iron earth lead wire 4 Sq mm as earthing electrode by means of nuts, bolts, check nuts and washers made of galvanised iron or steel earthing lead to be protected by galvanised iron pipe (medium grade) and other end connected to earthing test point as directed including providing funnel with 20mm bore galvanised iron pipe (light grade), wire mesh, charcoal or coke and common salt in alternate layer of 15cm (compacted thickness) all round the earth electrode, concrete earth pit in PCC (1:3:6) type C-1 (with 20mm graded aggregate), 50mm thick precast RCC (1:2:4) cover slab (re-inforced with 8mm dia TMT bar @ 15 cm C/C both ways and suitable handle made of 10mm dia) including necessary earth work in excavation, returning filling and removal of surplus earth up to a distance not exceeding 50 Mtr etc all as shown on electrical plate No. 5 of MES Schedule Part-I complete including testing on completion. On testing after completion if the desired earth resistance is not obtained the earthing will be made again by the contractor at no additional cost and complete all as specified and directed.
M/s TALCO
MS ORIENT ENGINEERING WORKS
R K UDYOG
M/S A C PAUL
M/S ASHRAFI CONSTRUCTION
S D CONSTRUCTION CO
MS UNITY CONSTRUCTION CO
B.B. Enterprise
stage.html
html • 0.07 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .