Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹82.4 LAdmitted-Finance | L1 | Admitted-Finance | |
| 2 | L2₹1.0 Cr+₹20.6 L (25.1%)Admitted-Finance | L2 | Admitted-Finance | |
| 3 | Rejected-Technical | - | Rejected-Technical Turn Over not as per requirement. | |
| 4 | Rejected-Technical | - | Rejected-Technical Labour 1970 not Found, Work Exp. and Turn Over not as per requirement. | |
| 5 | Rejected-Technical | - | Rejected-Technical Labour 1970 not Found |
| Sl No | Description | Qty | Unit | GANGA ELECTRICALS L1 | M/S Ajay Tripathi L2 |
|---|---|---|---|---|---|
| 0.00Construction of 33/11 KV S/S New Beli, Switchyard and 11 Kv Lines under Mahakumbh Mela 2024-25 | |||||
| 1.00 | Cartage of 11/9 Mtr long STP from Store to dump store/work Site including loading and unloading. | 40 | No | 399 ₹15,960 Lowest | 600 ₹24,000 |
| 2.00 | Cartage of 11 KV 3x 300 sq mm and 11 KV 3x185 sq mm XPLE cable from Store to dump store/work Site Including loading and unloading. | 6,800 | MTR | 15 ₹1,02,000 Lowest | 18 ₹1,22,400 |
| 3.00 | Cartage of 63 KVA 11/0.4KV from Store to dump store/work site including loading and unloading. | 1 | No | 2,999 ₹2,999 Lowest | 3,000 ₹3,000 |
| 4.00 | Cartage of 33 KV VCB and 11 KV Pannel with VCB,I/C & O/G, and 11 KV Bus Coupler from Store to dump store/work Site Including loading and unloading. | 22 | No | 3,999 ₹87,978 Lowest | 5,000 ₹1,10,000 |
| 5.00 | Cartage of 33 KV control Pannel from Store to dump store/work Site Including loading and unloading | 3 | No | 3,999 ₹11,997 Lowest | 5,000 ₹15,000 |
| 6.00 | Cartage of 33 KV PT and 33 KV CT from Store to dump store/work Site Including loading and unloading | 12 | No | 1,999 ₹23,988 Lowest | 3,000 ₹36,000 |
| 7.00 | Cartage of 10 MVA Power Transformer from Store to dump store/work Site Including loading and unloading | 2 | No | 9,999 ₹19,998 Lowest | 30,000 ₹60,000 |
| 8.00 | Erection of 11 mtr double pole support with fixing of necessary clamps, Cross Bracing angle and other accessories like channel, insulator etc..(as per RESSPO) All material provided by contractor except 11 M Long ST Pole. | 14 | Job | 15,999 ₹2,23,986 Lowest | 38,000 ₹5,32,000 |
| 9.00 | Fixing & grouting of stay rod with cement, sand and bricks ballast in ratio 1:4:8 and fastening the stay wire with pole and stay rod nuzzling (All require materials {Stay rod 16X1800mm, Stay wire 5 KG„ Stay clamp, Loop Insulator Bolt & nut )will be arranged by the contractor} | 6 | Job | 1,999 ₹11,994 Lowest | 3,200 ₹19,200 |
Tender Value
₹1.5 Cr
EMD Value
₹3.0 L
Closing Date
9 Jun 2023, 2:00 pmClosed
Superintending Engineer
Superintending Engineer, Temp. Maha Kumbh Mela 2024-25, Electricity Circle, Prayagraj
Refer to Tender Description
2023_PVVNV_808315_1
02/TMKM/EC/2023-24
Open Tender
Electrical Works
Lump-sum
180 days
Prayagraj
Please refer Tender documents.
2 documents required · 2 mandatory
₹11,800
Yes
Account # 50200079575664
₹3.0 L
Yes
22 Jun 2023
2 Jun 2023
9 Jun 2023
2 Jun 2023
9 Jun 2023
2 Jun 2023
Amount
Construction of 33/11 KV S/S New Beli, Switchyard and 11 Kv Lines under Mahakumbh Mela 2024-25
Cartage of 11/9 Mtr long STP from Store to dump store/work Site including loading and unloading.
Cartage of 11 KV 3x 300 sq mm and 11 KV 3x185 sq mm XPLE cable from Store to dump store/work Site Including loading and unloading.
Cartage of 63 KVA 11/0.4KV from Store to dump store/work site including loading and unloading.
Cartage of 33 KV VCB and 11 KV Pannel with VCB,I/C & O/G, and 11 KV Bus Coupler from Store to dump store/work Site Including loading and unloading.
Cartage of 33 KV control Pannel from Store to dump store/work Site Including loading and unloading
Cartage of 33 KV PT and 33 KV CT from Store to dump store/work Site Including loading and unloading
Cartage of 10 MVA Power Transformer from Store to dump store/work Site Including loading and unloading
Erection of 11 mtr double pole support with fixing of necessary clamps, Cross Bracing angle and other accessories like channel, insulator etc..(as per RESSPO) All material provided by contractor except 11 M Long ST Pole.
Fixing & grouting of stay rod with cement, sand and bricks ballast in ratio 1:4:8 and fastening the stay wire with pole and stay rod nuzzling (All require materials {Stay rod 16X1800mm, Stay wire 5 KG„ Stay clamp, Loop Insulator Bolt & nut )will be arranged by the contractor}
Grouting of ST Pole, grouting in ratio 1:4:8, cement, stone grit & coarse sand, plinthing of support of size 0.4x0.45x0.3 Mtr. with cement sand & bricks Ballast in ratio 1:4:8 and 12 mm thick plastering around the plinth in ration 1:2:4 with 12 mm thickness curing of plinth should be done properly. (as per RESSPO) All material provided by contractor.
Earthing of support (11 m pole) complete with the help of M.S. rod 20 mm Dia and 2.54 mtr. long, fastening of G.I. wire with clamps/X-arm/support to M.S. earth rod. As per RESSPO and Electrical safety rules. (All Material Provided by Contractor)
Painting of ST Pole and Channel & Clamps (double coat red oxide and double coat Alluminum paints. Painting materials provided by contractor.)
Laying of 11 KV 3x185 sq mm XLPE cable by manual method. The cable shall be laid at the depth of 1050 mm from the surface of road with the help of sand, brick & patiya including cartage. The cable shall be laid strictly in compliance to RESSPO Norms. (All required material except 11 KV XPLE Cable provided by Contractor)
Laying of 11 KV 3x185 sq mm XLPE cable by machine drill method. The cable shall be laid at the depth of 1050 mm from the surface of road including cartage. The cable shall be laid strictly in compliance to RESSPO Norms. (All required material except 11 KV Cable provided by Contractor)
Laying of cable by machine drill method with the help of HDPE in all horizontally under the road, minimum1050 mm bellow from the surface for laying of HDPE Pipe and laying of 11 KV 3x185 sq mm XLPE cable in 6'' Dia HDPE Pipe including cartage. (HDPE pipe will be provided by contractor except 11 KV XLPE cable)
Drilling in all horizontally to cross the road, 900 mm bellow from the surface for laying of HDPE Pipe and laying of 11 KV.3x185 sq mm XLPE cable in 6'' dia HDPE Pipe. (HDPE pipe and Fixing clamp will be provided by contractor, Except Cable).
Hoisting of 11 KV 3x185 sq mm XLPE cable providing GI pipe of size 4” dia 3 M long on double pole including its jumpering, complete with Channel, clamps, nut & bolts. (All materials will be provided by contractor except 11 KV,3X185 sq mm cable)
Supply & fixing of Underground cable route marker at every 200 mtr or as per site requirement.
Erection of complete busbar gantry in switch yard as per RESSPO drawing. Work also includes construction of gantry plinth of size 1.0x0.45x0.45 cum with cement, coarse sand and ballast in ratio 1:3:6 and plastering of plinth with cement & sand in ratio 1:4 including digging of pits & backfilling. All concreting material like Bus Gantry, Channel, Clamp, cement, ballast, sand labour & T&P etc. shall be provided by the contractor.
Erection, Grouting and earthing of complete structure for Line and Bus Isolator and Installation of 33 KV Line/Bus Isolator with all fitting in switch yard as per RESSPO drawing. Work also includes construction of plinth of size 1.0x0.45x0.45 cum with cement, coarse sand and ballast in ratio 1:3:6 and plastering of plinth with cement & sand in ratio 1:4 including digging of pits & backfilling. (All Require material as like structure, isolator clamps nut and bolts etc and concreting material like cement, ballast, sand labour Line/Bus Structure with fitting will be provided by the contractor.)
Erection of complete structure and installation of 33 KV lightening arrestor with earth counter meter, in switchyard as per RESSPO drawing. Work includes erection of 3 No.33 KV lightening arrestor, its fitting and mounting with care. Grouting of structure with cement, coarse sand and ballast in ratio 1:3:6, construction of plinth size 0.90x0.45x 0.45 cum. Plastering the plinth with cement mortar with cement and sand in ratio 1:4. (All required materials, like structure, isolator clamps, LA, Arrester structure with fitting, nut and bolts etc. and concreting material like cement, ballast, sand, labour will be provided by the contractor.)
Construction of complete T/F plinth size 3mx3m x 0.3 Mtr. above the ground level and 0.75 Mtr. deep foundation made as per drawing. Top of plinth is to be C.C. work in the ratio of 1:3:6 fitted with 3 Mtr. long, 90 lbs, 2 No. rail pieces. Cement mortar is to be used in 1:3 ratio. Cement, concrete material, bricks used in plinth shall be supplied by the contractor. 6” stone grit is to be laid before foundation start for whole plinth. All material shall be provided by the contractor.
Installation of complete 33 KV VCB 800A ,750MVA with structure in switchyard and grouting of VCB structure by cement, sand, brick ballast mortar in ratio 1:3:4. Work includes complete fitting of VCB on structure carefully with making all connections of control cable for operating the VCB. All Require item like Structure, cement, concrete material, T&P and all require clamp nut bolts and clamps shall be provided by the contractor except 33 KV VCB 800A, 750 MVA
Mounting of complete 33 KV C.T 400/200/1-1-1A (01 NO), 33 KV C.T 200/100/1-1-1A (02 NO) with structure in switchyard and grouting of C.T. structure by cement, sand, brick ballast mortar in ratio 1:3:4. Work includes complete fitting of C.T. on structure carefully with making all connections of control cable. All required items like, Structure, CT Clamps, cement, concrete material, T&P shall be provided by the contractor except 33 KV C.T.
Installation of complete 33 KV P.T (03 NO) with structure in switchyard and grouting of P.T. structure by cement, sand, brick ballast mortar in ratio 1:3:4. Work includes complete fitting of P.T. on structure carefully with making all connections of control cable. All Require item like Structure, Pt Clamps, cement, concrete material, T&P shall be provided by the contractor except 33 KV P.T
Installation of 33 KV single/double transformer control panel & 33 KV line control panel in the switchgear room and grouting the panel by rag bolt using cement, sand mortar in ratio 1:3. Work includes fitting of all accessories in all respect with complete connection of control cable with panel. (Grouting material and all require material as control cable 2x2 sq mm and 2x4 sq mm will be provided by the Contractor, except 33 KV single/double transformer control panel.)
Erection of 33 KV post Insulators with complete structure in Switch yard as per RESSPO drawing. Work includes Installation of 2X3 No. 33 KV Post Insulator on each structure complete as per schedule, grouting of Structure with 1st class brick ballast in the ratio of 1:3:6, plastering in the ratio of 1:3 on plinth size 0.90x0.45x0.45 Cum. The work is to be done strictly as per RESSPO drawing. (All the material like Structure, post Insulator clamp, Cement, concrete material used for above work will be provided by the Contractor.)
Installation of 33/11 KV 10 MVA T/F on the transformer plinth. This work includes dragging loading, shifting, lifting and complete assembling after placing on the plinth. All special and ordinary T&P is to be arranged by the contractor. Special care is to be taken to avoid tilting of T/F and loss of transformer oil. Any damage in T/F will be chargeable to contractor.
Laying of earth mat throughout 33 KV Switchyard area as per RESSPO design and drawing provided by the department. The work includes digging of trenches 0.75 Mtr deep as per drawing. Boring of G.I. pipe (size 2.5 mtr long 40 mm dia & 2.9 mm. thickness) up to 0.5 Mtr below ground level. Connecting all G.I. pipes with the help of G.I. Strips of size 35x6 mm (Approx. 600 Kg) with proper welding with high quality electrodes. All the material shall be provided by the contractor.
Earthing of all Structures erected in the yard with 35x6 mm. G.I. strip in duplicate fully welded at both ends to be connected to the earth mat, necessary G.I. strip. (All the material shall be provided by the contractor).
Earthing of 11 KV indoor equipments, switchgears as per RESSPO Drawing. with G.I. Strip of Size 50x6 mm, provided by the Contractor.
Earthing of 33 KV C.T. Structure complete as per schedule with 50x6 mm. G.I. Strip. (All earthing material shall be provided by the Contractor).
Special earthing of lightening arrestor structure with 8 No. additional 40 mm dia 2.5 Mtr. Long G.I. pipe electrodes/rod by digging 3 Mtr. deep pits and connecting it with L.A. through G.I. Strip 35x6 mm welded at both ends. (All the material Like G.I. pipe, G.I. strip shall be provided by the Contractor). As per RESSPO
Special earthing of T/F neutral by boring 2" dia 60 feet long G.I. pipe in the wet earth and connecting it with 35x6 mm. G.I. strip to T/F neutral giving half round turn at the T/F. Two separate earthing to be provided to T/F body by connecting it with earth mat by special earthing arrangement for earthing work. Material like strip of size 50x6/35x6 mm and G.I. pipe 2” dia 2.9 mm thick. (All the material shall be provided by the contractor).As per RESSPO
Laying and stringing of ACSR panther conductor for busbar between busbar gantry as well as terminal gantry. Three phase jumpering from bus to bar L.A, VCB, C.T., P.T., Post insulator, and 33/11 KV T/F, Terminal Gantry, Isolator etc. properly with jumpering with P.G. Clamp, T. Clamp and Post Insulator clamp. (All the material shall be provided by the contractor including ACSR Panther conductor.)
Erection Cable Stand in Switch yard for 1 No 33 KV Incoming Source and 2 No for 11 KV Power Transformer secondary side outgoing side. Including grouting and Clamping of cable (Cable stand as per sample, Grouting Material and clamp and nut bolts provided by contractor)
Painting of all structure and equipment inside the switchyard with two coats of red oxide primer and thereafter two coats of aluminum paint, giving silver white finish, painting is to be done after proper cleaning of the structures. (Paint, primer, thinner etc. required shall be provided by the contractor himself.)
Installation of fire stand as per sample for fire bucket with M.S. Angle Iron 50x50x6 mm with shed of M.S. sheet to cover the bucket and stand properly. (All material required for this work like M.S. Angle, 5 No. Fire bucket with stand, will be provided by the contractor).
Installation of 24 VOLT Battery and Battery Charger with Cabinet in the switchgear room, by grouting base channel clamp 100 x 50 x 6 x 1000 mm. Fixing of rag bolt. (Battery, Charger, Channel and Clamp will be provided by the contractor)
Laying of 11 KV 3 x 300 Sq mm. XLPE power cable by digging 0.75 Mtr. deep trench, putting layer of sand in the bottom, ramming it, laying of cable over it RMT and covering the cable from sides and top by laying bricks, finally covering the same by earth and leveling of the same. (All the materials, except cable, will be provided by the contractor).
Erection of sub station type 11m long STP double pole with mounting of accessories like 11 kv fuse set, TPMO, top channel, grouting in ratio 1:4:8, cement, stone grit & coarse sand, plinthing of support of size 0.4x0.45x0.3 Mtr. with cement sand& bricks Ballast in ratio 1:4:8 and 12 mm thick plastering around the plinth in ration 1:2:4 with 12 mm thickness curing of plinth should be done properly. (All materials will be arranged by the contractor except 11 Mtr long STP.)
Mounting of 63 kva T/F on DP along with HT/LT connection with support DD wire, lugs, z clamp for 63 kva T/f nut & bolt etc. (All material provided by contractor except T/F)
Fixing of following 11 KV Heat Shrinkable Type Cable Termination kits conforming to VDE-0278/1EEE-48-1975/IS – 13573-1992 and ESI STD. 09-13 all other relevant Standards complete with all accessories for 11 KV, 3x185 sq mm XLPE cable. (Jointing kit will be arranged by the contractor).
Outdoor jointing kit (Make Weasel/Raychem/3M) 3x 300 sq mm
Outdoor jointing kit (Make Weasel/Raychem/3M) 3x 185 sq mm
Indoor jointing kit (Make Weasel/Raychem/3M) 3x 185 sq mm
Indoor jointing kit (Make Weasel/Raychem/3M) 3x 300 sq mm
Straight through jointing kit (Make Weasel/Raychem/3M) 3x 185 sq mm
Installation of 11 KV VCB in the switchgear room, by grouting base channel 100 x 50 x 6 x 1000mm. Fixing of 11 KV switchgears rag bolt, mounting of P.T. on incoming.
11 KV incoming
11 KV O/G VCB
11 KV bus coupler
Laying of 0.4 KV Alm. PVC 4x25sq mm. power cable from substation T/F to L.T. Distribution Board. Approx Length of cable 100 Mtr. All materials ie LT Cable, DB, LT Power Board etc will be arranged by the contractor
Laying of following copper control cable form C.T., P.T., T/F to Transformer Control Panel / protection Board. (All control cable shall be supplied by the contractor).
Erection and Commissioning of lighting arrangement at six places on 9 Mtr. STP Pole with 110 watt LED, Cable, Switch board, MCB, Lamp and all other material like paint etc. Switching & wiring of light will be provided from control room. (All materials will be arranged by the contractor except 9 Mtr long STP).
Installation of Sign board at site after complition of work. Sign board size 3x4 feet with stand. (Writing material and sign board design will be provided by department and Sign Board, Stand and Grouting materials provided by contractor, Sing board will be provided by contractor as per sample provided by department.)
Photo and Videography before and after the work will be provided by the contractor in soft & hard colour copy (size 8x10" album) and soft copy video in minimum 1080 P quality in Pen drive in 3 set.
Extra leveling & Earth filling for control cable trench due to low density area.
Providing of following material at 33/11 NEW BELI S/S
Rubber Matting (size 3'x5')
Meager 5 KV, Clamp meter (1000Amp), Tool Kit, earth Chain, Rope-2.5" dia and 1.5" and 0.75: dia each 30 Mtr.
Fire Extinguisher (ABC type/DCP type)
Cealing Fan (48") 230V AC, 60-80 watt
M/S Ajay Tripathi
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .