Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹2.7 CrAccepted-AOC | ₹2.7 Cr | L1 | Accepted-AOC L1 |
| 2 | L2₹2.9 Cr+₹23.1 L (8.60%)Rejected-AOC | ₹2.9 Cr+₹23.1 L (8.60%) | L2 | Rejected-AOC L2 |
| 3 | L3₹3.4 Cr+₹75.5 L (28.1%)Rejected-AOC R 1 BEHIND MOTOR AIDS PETROL PUMP SWARG SHASTRI NAGAR JHOTWARA ROAD VILLAGE TOWN JAIPUR CITY JAIPUR JAIPUR RAJASTHAN 302016 INDIA | JAIPUR | RAJASTHAN | 302016 | ₹3.4 Cr+₹75.5 L (28.1%) | L3 | Rejected-AOC L3 |
Tender Value
₹3.5 Cr
EMD Value
₹7 L
Closing Date
15 Feb 2022, 3:00 pmClosed
Commissioner, DoIT and C
IT Building, Yojana Bhawan Campus, Tilak Marg, C-Scheme, Jaipur-302005 (Rajasthan)
Construction of boundary wall for Digital Fintech University, Jodhpur
2022_DoIT_255934_1
F.11(10)/DoITC/Prj/2022/ 00497/2022 Dt. 21.01.22
Open Tender
Civil Works
Item Rate
90 days
Jodhpur
Please refer Tender documents.
4 documents required · 4 mandatory
₹5,000
Yes
Commissioner, DoIT and C, Jaipur
₹7 L
Yes
RISL, Jaipur
8 Apr 2022
24 Jan 2022
15 Feb 2022
24 Jan 2022
15 Feb 2022
25 Jan 2022
31 Jan 2022
Amount
Boundary Wall
Earth work in excavation by mechanical means (Hydraulic Excavator) manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 Sq.mt on plan) including dressing of sides and ramming of bottoms, lift up to 1.5 m, including taking out the excavated soil and depositing and refilling of jhiri with watering & ramming and disposal of surplus excavated soil as directed with in a lead of 50 meter. All kinds of soils
Filling available excavated earth (excluding rock) in trenches, plinth side of foundation etc. in layers not exceeding 20 cm. in depth, consolidating each deposited layer by ramming and watering including lead up to 50 meter and with all lift.
Providing and laying in position cement concrete including curing, compaction etc. complete in specified grade excluding the cost of centering and shuttering - All work up to plinth level. 1:4:8 (1 cement : 4 coarse sand : 8 graded stone aggregate 40 mm nominal size).
Centering & shuttering with plywood or steel sheets including strutting, propping bracing both ways and removal of formwork for foundation, footing, strap beam, raft, bases of column etc. ( Footings and Plinth Beam.)
Providing and laying in position specified grade of cement concrete for all RCC structural elements up to plinth level including curing, compaction, finishing with rendering in cement sand mortar 1:3 (1 cement : 3 coarse sand ) and making good the joints and cost of plastizers (if required) excluding the cost of centering,shuttering and reinforcement. M35 grade Design Mix.
Providing and fabricating reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding (including cost of binding wire) all complete up to floor five level.- Thermo-mechanically Treated bars (Conforming of relevant IS code)
Brick work with F.P.S. bricks of class designation 75 in superstructure above plinth level upto floor V level in all shapes and sizes in : Cement mortar 1 : (1 cement : 4 coarse sand)
Painting with synthetic enamel paint of approved brand and manufacture to give an even shade : Two or more coats on new work.
Plaster on new surface on walls in cement sand mortar 1:4 including racking of joint etc. complete fine finish : 20 mm thk Cost includes scaffolding
Providing and filling joints between concrete and masonry in cement mortar including racking the joints to form "V" groove and filling with aggregate of 20 mm or less (katka) in cement mortar 1:4 ( 1 cement : 4 fine sand), cleaning and curing etc. to avoid cracks at the joints, as directed by the Engineer.
Random Rubble stone masonry for with hard stone in foundation and plinth in Cement Sand mortar above 30 CM thick wall in:Cement Mortar 1:6 ( 1-Cement : 6-Sand).
Providing & fixing precast cement concrete coping 1 : 2 : 4 mix 50mm thick complete as per specification :
Providing and fixing concertina coil fencing with required dia 610 mm (having 15 nos. round per 6 metre length) up to 3m height of wall with existing angle iron 'Y' shaped placed 2.4 m apart and with 9 horizontal R.B.T. stud tied with GI staples and GI clips to retain horizontal including necessary bolts or GI barbed wire tied to angle iron all complete as per direction of Engineer In Charge with reinforced barbed tape (R.B.T.)/Spring core(2.5 mm thick) wire of high tensile strength of 165 kg/sq.mm with tape (0.52 mm thick) and weight 43.478 gm/metre (Cost of MS angle, CC block shall be paid extra) RBT Reinforced Barbed Tape BTOBarbed Tape Obstacle 30 having Blade length ,Blade width ,Blade space ,Core wire dia. All as per given specification of RFP
Providing and fixing steel gate, grating , and grills made of angles, tees, square bars, flats,or black pipe with holdfast and fittings complete as per design and drawing including cutting welding and fabrication with priming coat of red oxide. Square,rectangular hollow tubelar sections are used or grill made by flats
Providing and fixing cow catcher made of R.S. joist angles channels MS rounds including cutting welding and fabrication with priming coat of red oxide (as per design provided by engineer in charge).
Tube Well
Construction of tube-well from ground levels and up to 100 Meter depth and above to accommodate housing and assembly pipe of following sizes in all types of alluvium strata by percussion / rotary drilling method and with gravel as per IS:4097-1967 and packing as per IS:2800 (Part I & II) 1979 as amended up to date (the work includes the cost of gravel & its primary packing and packing during development, lowering of housing & strainer assembly pipes, with supply and wrapping of coir rope, wherever necessary, for arresting fine sand particles. The work will not include cost of housing pipe and strainer pipe assembly and development work, but work would be completed after obtaining sand free water). - 200 mm Nominal bore.
Supply of ERW M.S. black casting pipe ISI marked (IS:4270/1992) of grade Fe 410 of following sizes at site of work. - 200 mm nominal bore
Supply of strainer pipes made of ERW M.S. black pipe ISI mark of following sizes at the site of work including required size of slotting as per IS:8110-1985. - 200 mm Nominal Bore.
Supply & fixing of B class 50mm dia GI pipes with flanges duly screwed & welded including rubber washer, nuts & bolts of 8mm dia complete in all respect ISI make.
SITC of radial / mixed flow submersible motor pump sets ISI marked (IS:8034-1989) of approved make with required accessories including making connection suitable for T.W./ D.C.B./ Open well. The job includes lowering of riser pipe, G.I./ H.D.P.E. pipe with rope, cables, installation of complete fitting and accessories, jointing of electrical cables up to switch board. All labour for testing of submersible pumps set and supply of water to water mains, complete in all respect.150 mm diameter Submersible pump shall have following HP Rating, phase, Head, minimum Discharge respectively.
3.0 HP, 3-Ø, (54 -95)Mtr, (250-50) LPM
7.5 HP, 3-Ø, (76 - 96)Mtr, (285-180) LPM
5.0 HP, 3-Ø, (68 - 102)Mtr, (225-85) LPM
Supply and fixing of oil / Air break DOL / Star Delta Starter made out of sheet steel powder coated enclosure with single phasing protection, ON / OFF push buttons, etc. complete in all respect suitable for following rating motors.
Fully Automatic Star/ Delta Starter 3.0 HP to 10.0 HP
Supplying and Laying ISI marked P.V.C. insulated submersible cable as per PWD specification for electrical Works confirming to IS:694 and as per IS 8130 : 2013 of 1.1 kV grade .Wire should be made from 99.99% purity copper, class 5 stranding in acc. to IEC 60228 for lower watt loss , oxygen free ( <10 ppm) for less chances of oxidization and higher silver content for gives better conductivity , insulation PVC type A ,flame retardant as per IS 10810-53, better amperage rating as per VDE 0298 part 4 including making connection etc. as required. OEM Must have its own in house NABL lab setup for all testing facilities for wires. All as per pre approved by Engineer in charge, making connections. as per recommended makes of RFP
6.0 Sq.mm 3 core flat / Round
SITC of wall/ free standing floor mounted dust and vermin proof compartmentalised cubical panel as per PWD specification for electrical Works, made out of CRCA sheet . Other parameters required as per point (a) ,(b), (c),(d) below:- (a)Thickness of sheet shall not be less than 1.6 mm up to 600 mm length / width of any compartment and be of 2.0 mm above 600 mm. Load bearing structure shall be of 2.0 mm thick sheet supported by base M.S. channel if required . Side walls and cable alley compartments having bolted type doors with / without detachable extension type structure (b)panel shall be duly treated for derusting in 7 tank process with dephosphating and with powder coating of minimum 70 microns on both side of panel in desired shade The panel having PU/ Neoprene rubber gasket of not less than 3mm thickness ,required hardware, separate detachable gland plate M.S. base channel (min75mm) , hinged door with locking arrangement for equipment/switchgear [c) Interconnection between bus bar and switchgears /cable shall be rigidly supported and made out by flexible copper wires (up to 125 amp ) and by solid bus bar (>125 amp ) . All joints / interconnections of copper bus bar shall be dully tinned . Clearance between main bus bar and risers / metal parts shall be at least 10 mm additional to width of bus bar Bus bar is insulated by Heat Shrinkable sleeves . Earth and Neutral bus bar shall be half of the size of phase bus bar. (d) only outer area on all sides shall be measured & panel to be fabricated only from CPRI approved fabricator. All as per drawing pre approved by Engineer in charge.
Supplying and fixing of Aluminium (IEC 60105 ISO 209-1,2) / Copper (IEC 60028) bus bar as per PWD specification for electrical Works, by means of SMC / DMC type insulator, high tensile nuts and bolts spring washers in existing panel including bending , cutting in required shape and size and colour coding with heat shrinkable PVC sleeves. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure "A" attached with this BSR . Electrolytic grade Aluminium bus bar 6010 grade
Providing & Fixing of BIS approved Current Transformer as per PWD specification for electrical Works ,ISI marked as per IS 2705-1992/ conforming to IEC 60044-1, with secondary terminal of CT shall be brought out suitable to a terminal block which shall be easier accessible for testing and terminal connection , with all necessary support in existing panel including connection etc. as required Current transformer Resin Cast Wound Primary / Ring Type Tape Wound as per IS 16227 with, Accuracy Cl, CT ratio and burden as specified. ISF<=5, Cu cross section of secondary wire 1.5sqmm (minimum), including all necessary support in existing panel including connection etc. as required . All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure "A" attached with this BSR .
C T Class 1, Ratio upto 150/5, Burden 5 VA
Providing & Fixing of ISO certified company made UL listed , IP 65 110/220 V, unibody LED Indicating lamp IEC 60947 , CSA 22.2 with integral circuit, IP 20 terminal block, Approx. body dia for panel not less then 20 mm, length min. 50mm, front LED cover dia min. 29 mm, contact material phospher bronze for Led, PCB contacts shall be of brass (tin plated), impulse dielectric tested for 2.5 KV, Rated insulation resistance shall be 100 M ohm at 500VDC including connection etc. as required. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure "A" attached with this BSR .
Red/yellow/Green colour
Blue / white Colour
Multifunction LCD meter with V, I, F, PF, KW, Kva, Kvar, Kwh, Kvah, Kvarh, Run hours, On hours, Phase angle, Interrupts, THD, Events, Neutral Current class 1 accuracy with RS485 port.
SITC of IP 40 3 pole current limiting Moulded case circuit breaker (MCCB) made of flame retardent & heat resistant material having following current rating, short circuit breaking capacity at 440/415 V, 50 Hz; O/L & S/C settings as per PWD specification for electrical Works, conforming to IS/IEC 60947 P -2 :2003 with front face and centralised adjustable, trip free mechanisum, true contact position indicator, line load interchangeability, designed for both horizontal & vertical mounting without any adverse effect on electrical performance, suitable for operation upto 55 degree and without derating upto 40 degree, pollution degree 3, having positive isolation capability, push (test) to trip, trip time less then 10 ms under s/c condition, Breaking capacity Ics = 100% Icu. U imp =8 KV, rated insulation voltage 800 V, provision for UVR , shunt trip , earth fault trip, door interlock, pad lock & rotary handle , including making connections with lugs & spreaders, etc. as required. OEM shall have submit NABL / CPRI / ERDA accrediated lab type test certificate before execution. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure "A" attached with this BSR .
With Thermal Magnetic release
up to 100 Amp , 25 kA, adjustable O/L & fixed S/C setting, Ics = 100 % Icu
Providing & Fixing of 240/415 V AC MCB with positive isolation of breaking capacity not less than 10 KA (B/ C tripping characteristic as per type of load and site requirement) 4KV impulse withstand voltage, as per PWD specification for electrical Works with ISI marked IS 8828(1996) / conforming to IEC 60898-1 2002, IEC 60947-2, low watt losses, trip free mechanisum , energy limiting of class 3 as per IEC, minimum phase termination capacity of 35sq.mm. , conductorline load reversibility, label holding facility , IP 20 contact protection and fitted with existing distribution board/sheets, min. operation 20,000 upto 32 A rating and 10,000 upto 63 A, 5000 for 80 A rating including making connections, testing etc. as required. . OEM shall have submit NABL / CPRI / ERDA accrediated lab test reports before execution & All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure "A" attached with this BSR .
Four pole MCB , 40 A- 63A rating
Double pole MCB, 6 A to 32 A rating
Supply Installation testing & Commissioning of ISO certified company made DOL/Star-Delta Starter panel made out from 1.6 mm thick powder coated CRCA sheet, enclosure comprising of over load protection relay, short circuit & single phasing protection, Illuminated ON / OFF push buttons, ammeter, voltmeter, indicating lamps etc. suitable for following rating motors complete in all respect. Appropriate type test certificate / OEM test report shall be submitted. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure "A" attached with this BSR .
For Three phase Submersible / Mono block pump
3.0 HP to 10.0 HP ( Star / Delta starter )
Providing & Laying of synthetic rope for submersible pump ISI marked (IS:5175) of following sizes. complete in all respect. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure "A" attached with this BSR .
20mm (suitable for 90 mm OD pipe)
Plate Earthing as per PWD specification for electrical Works as per IS:3043 with Hot dipped G.I. Earth plate of size 600mm x 600mm x 6.0mm by embodying 3 to 4 mtr. below the ground level with 20 mm dia. G.I. 'B' class watering Pipe ,including all accessories like nut, bolts, reducer, nipple, wire meshed funnel, and Heavy duty weather proof poly-propylene earth pit chamber with lockable Jam free lid suitable for safe working load 5000 Kg or more of size Top Dia. 225 to 260 mm, Bottom Dia 300 to 350 mm. and Height 250 to 300 mm. and embodying the pipe complete with alternate layers salt and coke/ charcoal, testing of earth resistance for value of 5 ohms or less as required & must record by engineer in charge during site visit and ensure to enter in measurment book. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure "A" attached with this BSR .
Supply & Laying following size earth wire in horizontal or vertical run in ground/surface/recess including riveting, soldering, saddles, making connection with GI/Cu thimble etc. as required. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure "A" attached with this BSR .
8 SWG copper Wire
Supply & Laying following size earth strip in horizontal or vertical run in ground/surface/recess including riveting, soldering, saddles, Jointing shall be done by overlapping and with 2 set of Brass (for Cu strip) / GI (for GI Strip) nut bolt & spring washer spaced at 50cm making connection etc. as required. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure "A" attached with this BSR .
20mm x 3mm copper strip
Providing & Fixing of HDPE pipe ISI mark (IS:4984/2016 ) for water supply (suitable for submersible & jet pump) with required fittings ie socket, elbows, tee etc. complete in all respect. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure "A" attached with this BSR .
50 mm OD 6 kg / cm2
M/S HEERARAM GODARA
Eminent Colonizers Private Limited
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .