Loading…
Loading…
| # | Company | Offered Item | Amount | Rank | Status |
|---|---|---|---|---|---|
| 1 | Not yet disclosed by govt. Qualified Make: VINTEX
Model: FIRE EXTINGUISHER DRY POWDER 10 KG | Make: VINTEX
Model: FIRE EXTINGUISHER DRY POWDER 10 KG | - | - | Qualified MSE, Category: General |
| 2 | L1₹3.1 LDisqualified Make: VINTEX
Model: FIRE EXTINGUISHER DRY POWDER 10 KG 5 DIGITAL TELELING CO JAISAMER JAISELMER RAJASTHAN 345001 | JAISALMER | RAJASTHAN | 345001 | Make: VINTEX
Model: FIRE EXTINGUISHER DRY POWDER 10 KG | ₹3.1 L | L1 | Disqualified |
Tender Value
Refer Docs
EMD Value
₹9,936
Closing Date
28 Aug 2018, 10:00 amClosed
DRY POWDER FIRE EXTINGUISHER FOR METAL FIRES DRY POWDER FIRE EXTINGUISHER FOR METAL FIRES ( 96 ) Technical Specifications Specification Specification Name Values Allowed Values Generic ITEM ISI marked Dry powder fire extinguishers for Class D fires ( fires due to burning of metals ) - Conformity to Indian Standard IS 11833 latest - Method of expulsion of dry powder The method of expulsion of dry powder .shall be by means of pressure produced from compressed or liquefied gas from gas cylinder or cartridge attached to the body. - Extinguishing Media Dry Powder to IS : 4861-1984 - Dry Powder Content capacity (minimum) 10 10
25
50
75
100 Constructional Expellent gas cylinder Manganese steel cylinder to IS:7285 and CO2 Gas Cartridge to IS : 4947 - Expellant Medium (CO2 gas cylinder) capacity 10 - 1/6 Test Pressure for The extinguisher body and the cap (without the safety release valve) minimum internal hydraulic pressure of 3.0 MN/m 2 (30 kgf/cm 2 ) for a period of 5 min - Burst pressure for The extinguisher body and the cap (without the safety release valve) minimum internal hydraulic pressure of 4.5 MN/m 2 (45 kgf/cm 2 ) - Dry powder used shall conform to IS : 4861-1984 Yes - Rechargebale Yes - Construction as per clause 6 of IS :11833 - Material for construction of various parts of the fire extinguisher as given in Table 1 to IS:11833 - Thickness of cylindrical main body (minimum) For 10 Kg cylinder 2mm For 10 Kg cylinder 2mm
For 25
75 Kg cylinder 3.15mm
For 100 Kg cylinder 6mm Outside diameter of cylindrical main body For 10 Kg cylinder 170 to 185mm For 10 Kg cylinder 170 to 185mm
75 Kg cylinder 750mm max
For 100 Kg cylinder 750mm max "Neck Ring with parallel screw threads conforming to class A of IS 2643 (Part I) for an effective length of not less than 25 mm threads provide a clear opening of not less than 75 mm diameter" Yes - "Threaded Cap for not less than 20 mm effective length with parallel threads conforming to class A of IS 2643 (Part 1)" Yes - Discharge Hose length For 10/25Kg cylinder 2 meter minimum - Discharge Hose Diameter minimum For 10/25Kg cylinder 12.5 mm minimum - Wheeled Carriage for 25/50/75/100 Kg(slect NA for 10 kg) as per IS 11833 Yes - 2/6 Expansion Space above dry powder Level in the Body Sufficient volume to ensure that when discharge nozzle is temporarily closed and the extinguisher is operated at a temperature of 27 ± 2°C
the internal pressure shall not exceed 1·5 MN/m2 ( IS kgf/cm' ) and the body shall not show any sign of leakage - "Applicator fitted to the discharge end of the hose by a coupling" "The applicator shall consisting an extended pipe
not Jess than 1 m long
with a dome bell at its end and provided with deflecting vanes so as to sprinkle the powder on the burning reactive metal surface
as a low pressure discharge
to give the performance characteristics" - ANTICORROSIVE TREATMENT "All internal surfaces of the body and other internal parts shall be completely coated with zinc or Jead-tin in alloy ( tin nut less than 10 percent) either by hot dipping process or by electrodeposition process or by phosphating
to a thickness of not less than 0·025 mm." - Color Each extinguisher body shall be painted either with epoxy powder coating orsynthetic enamel paint. The shade shall be ‘Fire Red’ or ‘Post Office Red’conforming to Shades No. 536 or 538 of IS 5 - Performance Discharge Capacity minimum 85 percent by mass of the actual rated capacity of the extinguisher
when the extinguisher is set into operation under normal minimum 85 percent by mass of the actual rated capacity of the extinguisher
when the extinguisher is set into operation under normal 3/6 temperature conditions of 27° C ± 2°C temperature conditions of 27° C ± 2°C Duration of Discharge wrt capacity 20 to 30 second for 10kg 20 to 30 second for 10kg
30 to 40 second for 25kg
40 to 50 second for 50kg
50 to 60 second for 75kg
70 to 80 second for 100kg Fire Rating for which Fire Extinguisher is suitable class D - Bursting Pressure of Braided Rubber or Plastic Hose (kg/cm²) 55 - Certification BIS Marking to IS 11833 Yes - CM/L Number with Validity Period - - ECO marking true - Availability of Test Report from Central Govt/NABL/ILAC acredited lab to prove confirmity to specification Yes - Test Report No - - Test Report Date - - Name of the Lab - - Address of the Lab - - Test Report to be provided to the buyer on demand Yes - * Bold specifications are the golden parameters. Consignees and Quantity S.No. Consignee Address Quantity Delivery Days 1 Gaurav Dubey 345001
Air Force Station Jaisalmer(Raj) 96 15
477163
GEM/2018/B/67448
DRY POWDER FIRE EXTINGUISHER FOR METAL FIRES
15 days
Rajasthan; Jaisalmer
PRODUCT
| Item | Delivery Location | Qty | Delivery |
|---|---|---|---|
| DRY POWDER FIRE EXTINGUISHER FOR METAL FIRES DRY POWDER FIRE EXTINGUISHER FOR METAL FIRES ( 96 ) Technical Specifications Specification Specification Name Values Allowed Values Generic ITEM ISI marked Dry powder fire extinguishers for Class D fires ( fires due to burning of metals ) - Conformity to Indian Standard IS 11833 latest - Method of expulsion of dry powder The method of expulsion of dry powder .shall be by means of pressure produced from compressed or liquefied gas from gas cylinder or cartridge attached to the body. - Extinguishing Media Dry Powder to IS : 4861-1984 - Dry Powder Content capacity (minimum) 10 10 | - | - | - |
| 25 | - | - | - |
| 50 | - | - | - |
| 75 | - | - | - |
| 100 Constructional Expellent gas cylinder Manganese steel cylinder to IS:7285 and CO2 Gas Cartridge to IS : 4947 - Expellant Medium (CO2 gas cylinder) capacity 10 - 1/6 Test Pressure for The extinguisher body and the cap (without the safety release valve) minimum internal hydraulic pressure of 3.0 MN/m 2 (30 kgf/cm 2 ) for a period of 5 min - Burst pressure for The extinguisher body and the cap (without the safety release valve) minimum internal hydraulic pressure of 4.5 MN/m 2 (45 kgf/cm 2 ) - Dry powder used shall conform to IS : 4861-1984 Yes - Rechargebale Yes - Construction as per clause 6 of IS :11833 - Material for construction of various parts of the fire extinguisher as given in Table 1 to IS:11833 - Thickness of cylindrical main body (minimum) For 10 Kg cylinder 2mm For 10 Kg cylinder 2mm | - | - | - |
| For 25 | - | - | - |
| 75 Kg cylinder 3.15mm | - | - | - |
| For 100 Kg cylinder 6mm Outside diameter of cylindrical main body For 10 Kg cylinder 170 to 185mm For 10 Kg cylinder 170 to 185mm | - | - | - |
| 75 Kg cylinder 750mm max | - | - | - |
| For 100 Kg cylinder 750mm max "Neck Ring with parallel screw threads conforming to class A of IS 2643 (Part I) for an effective length of not less than 25 mm threads provide a clear opening of not less than 75 mm diameter" Yes - "Threaded Cap for not less than 20 mm effective length with parallel threads conforming to class A of IS 2643 (Part 1)" Yes - Discharge Hose length For 10/25Kg cylinder 2 meter minimum - Discharge Hose Diameter minimum For 10/25Kg cylinder 12.5 mm minimum - Wheeled Carriage for 25/50/75/100 Kg(slect NA for 10 kg) as per IS 11833 Yes - 2/6 Expansion Space above dry powder Level in the Body Sufficient volume to ensure that when discharge nozzle is temporarily closed and the extinguisher is operated at a temperature of 27 ± 2°C | - | - | - |
| the internal pressure shall not exceed 1·5 MN/m2 ( IS kgf/cm' ) and the body shall not show any sign of leakage - "Applicator fitted to the discharge end of the hose by a coupling" "The applicator shall consisting an extended pipe | - | - | - |
| not Jess than 1 m long | - | - | - |
| with a dome bell at its end and provided with deflecting vanes so as to sprinkle the powder on the burning reactive metal surface | - | - | - |
| as a low pressure discharge | - | - | - |
| to give the performance characteristics" - ANTICORROSIVE TREATMENT "All internal surfaces of the body and other internal parts shall be completely coated with zinc or Jead-tin in alloy ( tin nut less than 10 percent) either by hot dipping process or by electrodeposition process or by phosphating | - | - | - |
| to a thickness of not less than 0·025 mm." - Color Each extinguisher body shall be painted either with epoxy powder coating orsynthetic enamel paint. The shade shall be ‘Fire Red’ or ‘Post Office Red’conforming to Shades No. 536 or 538 of IS 5 - Performance Discharge Capacity minimum 85 percent by mass of the actual rated capacity of the extinguisher | - | - | - |
| when the extinguisher is set into operation under normal minimum 85 percent by mass of the actual rated capacity of the extinguisher | - | - | - |
| when the extinguisher is set into operation under normal 3/6 temperature conditions of 27° C ± 2°C temperature conditions of 27° C ± 2°C Duration of Discharge wrt capacity 20 to 30 second for 10kg 20 to 30 second for 10kg | - | - | - |
| 30 to 40 second for 25kg | - | - | - |
| 40 to 50 second for 50kg | - | - | - |
| 50 to 60 second for 75kg | - | - | - |
| 70 to 80 second for 100kg Fire Rating for which Fire Extinguisher is suitable class D - Bursting Pressure of Braided Rubber or Plastic Hose (kg/cm²) 55 - Certification BIS Marking to IS 11833 Yes - CM/L Number with Validity Period - - ECO marking true - Availability of Test Report from Central Govt/NABL/ILAC acredited lab to prove confirmity to specification Yes - Test Report No - - Test Report Date - - Name of the Lab - - Address of the Lab - - Test Report to be provided to the buyer on demand Yes - * Bold specifications are the golden parameters. Consignees and Quantity S.No. Consignee Address Quantity Delivery Days 1 Gaurav Dubey 345001 | - | - | - |
| Air Force Station Jaisalmer(Raj) 96 15 | - | - | - |
₹9,936
17 Sept 2018
14 Aug 2018
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
bid_477163.pdf
GEM_BID
termsCondition.pdf
OTHER
2657c7ca70287299b5181580fdb5a7ab.pdf
OTHER
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .