Superintending Engineer, O and MC-V, BTPS, Anpara
Office of The S.E., O and MC-V, BTPS, Anpara
Preventive and breakdown maintenance of PF, DE DS and AC System installed in CHP, BTPS, Anpara
2022_RVUNL_683380_1
01/CHD-I/BTPS/2022-23
Open Tender
Miscellaneous Works
Fixed-rate
365 days
Anpara Thermal Power Station
AS PER TENDER DOCUMENTS
3 documents required · 3 mandatory
₹1,180
Dy. CAO, CFO and BO, BTPS, Anpara
₹72,000
19 Apr 2022
31 Mar 2022
16 Apr 2022
31 Mar 2022
15 Apr 2022
31 Mar 2022
31 Mar 2022 - 15 Apr 2022
120 days
Amount
Routine checking, attending, preventive maintenance of Paddle Feeders of C.H.P.(2X500 MW) round the clock.
Replacement of damaged blades of P.F. by new/repaired one
Replacement/welding of damaged/ deformed blades-tip of P.F. blade by new/repaired one.
Replacement of damaged bearing/plumber block of wheel.
Checking re-alignment & levelling of 2 rail track section for PF Travelling (per section of 20 meter length)
Torque setting of blade fixing bolts (24no. per PF)
Repairing of garland idler & supporting frame
Replacement of damaged skirt rubber lining of P.F
Adjustment/positioning/ Refixing of skirt board plate/ element wear palte of P.F.
Replacement of damaged/worn-out liner plate, mother plate of the hopper of the PF
Shifting of P.F. up to head end/tail end by dismantling of blades
Replacement/Servicing of check valve/ charge valve / high pressure relief valve / servo control valve / expansion bladder
Replacement/Servicing of suction oil filter / hose pipe
Draining of oil /Oil tank cleaning / Flushing of entire hydraulic system and re-filling
Repairing & replacement of damaged / deformed pipe line by cutting, welding, machining etc.
Replacing hydraulic pump coupling bracket
Replacement of damaged idler / idler frame
Re-railment of derailed P.F.
Replacement of blade drive shaft
Replacement of Epicyclodal reducer for Travelling BREVINI make Gear Box of CRD /Magnetic Coupler
Replacement/Repairing of damaged coal deflectors
Repairing/Re alignment of the cable reeling drum structure by cutting, welding etc.
Dismantling of damaged cable reeling drum Gear box after opening flanges/gear reducer unit, repairing and re commissioning of the same
Replacement of ribbed bush fitted between the coupling of blade drive pump / travelling pump and electric motor and alignment of the same.
Replacement of Bearing/Seals of slewing pump/Travelling Pump/hydraulic motors
Shaping of the PF Rail Track by Grinding, cutting etc.
Adjustment/positioning of reaction arm
Adjustment/positioning of thrust disc
Fabrication & fixing of 'V' shaped cutting teeth at the bottom surface of the blade
Replacement of hydraulic motor for slewing
Replacement of hydraulic motor for travelling
Replacement of bearing of magnetic coupler
Replacement of magnetic coupler from one P.F to another in emergency
Un-mounting/Mounting of travelling/slewing pump due to Failure of Electrical motor
Replacement of travelling/slewing pump from one P.F to another in emergency
Replacement of Axial shaft with complete assembly by repaired one
Dismantling of Broken Axial shaft with Complete Assembly
Fabrication & Fitting of P.F Blade shim by 20mm M.S. Plate
Repairing of the blades of the Paddle Feeder taking cost of special welding electrodes for PF blade tips and hard facing of the PF blades.
Dismantling of damaged spillage protection plates, fabrication of the new plates from Fresh/Scrap steel, re fixing of the new plates and strengthening of them with stiffeners.
Tightening of Arm Supports (390 no) of the hopper base plates by tightening of the Anchor bolts(04 no Anchor bolts per Arm)
Repairing of the Hopper Railing by gas cutting, welding etc.
Repairing/reconditioning/recasting of special type coupling with spline internal gear teeth.
Repairing/reconditioning/recasting of special type pump shaft having spline gear teeth at three stages with heat treatment of paddle feeder.
Repairing/reconditioning/recasting of input bevel pinion shaft and its matching bevel gear along with heat treatment (case hardening/surface hardening) of CRD gear box of paddle feeder.
Repairing/reconditioning of special type spline bush having spline internal gear teeth of paddle feeder coupling.
Routine/Preventive maintenance of the air conditioning system in MSS, SS-1, SS-2, S/R machine, Coal Lab, T/H control Room of CHP-2X500MW as per scope of work.
Repair/revision of circulating water pumps 'Hitachi' make of 2.2 / 1.5 kw
Rewinding of motors up to 0.5 kw
Rewinding of motors up to 1.0 kw
Rewinding of motors up to 5.0 kw
Refrigerant charging of 7.5 ton Daikin/ Carrier/ Voltas/Fridgory Air Cooled Air Conditioning Units after flushing of the unit with Nitrogen.
Refrigerant charging of 7.5/5.5 ton Water Cooled Daikin unit, 2.5 ton Split type Air Conditioning Units and 1.5/2.0 ton RAC (Window ACs) after flushing of the unit with Nitrogen.
Refrigerant charging of 7.5 ton water cooled Daikin unit (Cooling coil, condenser VOLTAS make) after flushing of the unit with Nitrogen.
Top up of the refrigerant of units as per the requirement.
Routine checking ,attending of DE & DS system (cyclone units) of CHP(2X500MW) including T/H & S/R system round the clock as per the scope of work.
Checking & preventive maintenance of the ventilation system of entire CHP(2X500 MW) including T/H, Emergency Hopper, MSS, SS-1, SS-2, PCH, SCH, Pent House, Battery room, Lift rooms, Bunker bay as per scope of work.
Routine checking, attending & minor maintenance of Sump Pumps of CHP area which includes 18 pumps located at 9 pumping stations e.g. T/H(-level), Emergency Hopper(-level) and other places of different capacities as per scope of work.
Operation of spray water pipe line and routine checking of CF Fans at Track hopper of CHP-2x500 MW, BTPS
Laying & Fabrication of MS/GI pipe line
Fabrication & erection of MS/GI Bends & Tees
Dismantling of pipe lines
Erection of flanges/ valves on flanges/ valves with welded joint
Dismantling of valves
Excavation & back filling of earth
Attending leakage in lines by welding/patching
Servicing of valves (Gate valve, Glove valve, Butterfly valve, Non return valve)
Cleaning & Choking removal of sump pump
Cleaning & choking removal of DE/DS Cyclone
Cleaning of Cyclones, its entire ducts, Extraction hoods & nozzle headers.
Cleaning of DE/DS Reservoir Tank.
cleaning of settlement tank from stage 1 to stage 3
Repairing of Ducts/Extraction Hood by patching etc. (upto 100mm x100 mm)
Mechanical mantenance of Multistage vertical pump (4 kw - 16 kw)
Overhauling of Multistage pumps
Overhauling of Sump pump 1.5 KW to 3.7 KW(submersible type)
Cleaning of ventilaton system/ points
Mechanical Maintenance of Centrifugal fans/ Cyclones
Overhauling of centrifugal fans
Servicing of fire spray nozzle.
Attending leakage in underground pipeline by welding/patching up to 300mm dia. and 5ft deep
Overhauling of Sump pump (submersible type) 12KW- 20KW.
Over Hauling/Mechanical Maintenance of Ventilation Fan
Maintenance of water spray/over head water spray system by welding/patching at T/H, around/along with road/lawn etc.
SHIVA CONSTRUCTION
M/S JISHA ENGINEERING CONSTRUCTION
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .