Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹9.3 CrAccepted-AOC HSVP PANCHKULA | PANCHKULA | HARYANA | 133301 | ₹9.3 Cr | L1 | Accepted-AOC Lowest Rates |
| 2 | L2₹9.6 CrRejected-Finance 858 SECTOR 23 127021 | BHIWANI | HARYANA | 127021 | ₹9.6 Cr | L2 | Rejected-Finance Higher Rates |
| 3 | L3₹9.7 CrRejected-Finance 81 ARYA NAGAR ASSANDH ROAD PANIPAT HARYANA 132103 | PANIPAT | HARYANA | 132103 | ₹9.7 Cr | L3 | Rejected-Finance Higher Rates |
| Sl No | Description | Qty | Unit | M/S SHREE BALAJI BUILDERS L3 | Himmat Singh Contractor L2 | Rajesh Kadiyan Contractor L1 |
|---|---|---|---|---|---|---|
| 1.00Works Details | ||||||
| 1.10 | Supply ,Erection, Testing and Commissioning of Horizontal Split Casing Raw Water Pumping Set with CI Body SS Impeller Gland Pack duly coupled to Suitable rating of Motor 1440 RPM on a common Base Plate -Discharge -15300 LPM X 15 m Head | 3 | Each | 6,35,000 ₹19.1 L | 5,00,000 ₹15 L | 5,25,500 ₹15.8 L |
| 2.00 | SIM Card for Five year operation of all the instrument above as required. | 92 | Each | 835 ₹76,820 | 1,000 ₹92,000 | 1,000 ₹92,000 |
| 3.00 | Supply, Installation, testing, Commissioning with Maintenance of five year of Radar and Water Level Transmitter along with according to water level in OHSR (for OHSR) Ingress Protection – IP 66, Measuring range – Up to 20 M, Process temp.- -40 to 60 deg. C, Full PVDF Body – For a long sensor lifetime **Unit Rate given, actual quantity to be ascertained while placing order | 25 | Each | 32,335 ₹8.1 L | 50,000 ₹12.5 L | 52,600 ₹13.2 L |
| 4.00 | Functional Integration at RTU-cum- Gateway for Motorized Control Valve in Pump Control Panel. With five year maintenance. | 92 | Each | 22,335 ₹20.5 L | 30,000 ₹27.6 L | 30,000 ₹27.6 L |
| 5.00 | Supply of Water Meter inclusive all taxes. | 5,993 | Each | 1,377 ₹82.5 L | 1,000 ₹59.9 L | 1,635 ₹98.0 L |
| 6.00 | Design, Supply, installation and testing of VFD along with distribution panel in enclosure for motor rating of 125 HP. Enclosure shall be IP54. The panel shall be equipped with MCCB TP with suitable rating, Spreader link TP, Extended rotary handle, Volt meter digital, Volt selector switch, Amp meter, Amp selector switch, C.T with suitable rating, Control MCB SP with suitable rating, PLA Relay, Push button red plus green with element, Indicator ON/Off, Aluminium Bus bar/suitable rating power and Control wiring labour and margin, Fabrication with minimum Sheet thickness of 2 mm for load bearing and non-load bearing side. VFD should be capable of protecting motor from high and low voltage and earth fault as well. VFD should restrict harmonics up to 35% VFD should be capable of providing starting torque up to 200% while starting motor. It should have class 3C3 (Avg)conformal coating so that components are safe from dust and moisture. Communication -Built-in RS485 Modbus RTU, Ambient Temperature -Heavy Duty: -10 ~ 50 deg C Normal Duty: -10 ~ 40 deg C, PCB Protection Conformal Coating complying to IEC 60721-3-3 class 3C3, Application Humidity Below relative humidity 95% RH (no condensation) Altitude 0 to 1,000 m Without deration 1,001 to 4,000 m With deration of 1% per rise in 100 m, Vibration Up to 9.8 m/sec2 (1.0 G), Global Compliance CE, UL, RoHS, Control Method V/F Control, Sensorless Vector Control, Slip Compensation, Closed Loop Vector Control. Starting Torque 200% at 0.5Hz in Sensorless Vector Control and 150% at 3Hz in V/F, Frequency Control Range 0 to 400Hz in V/F, 0 to 300Hz in Sensorless 1, 0 to 120Hz in Sensorless 2 / Vector, Frequency Precision Setting- Digital: 0.01Hz, Analog: 0.03Hz (60Hz Base). complete with all other accessories as required. [For B/S No. 2]. | 2 | Each | 3,05,335 ₹6.1 L | 3,50,000 ₹7 L | 3,65,100 ₹7.3 L |
| 7.00 | Design, Supply, installation and testing of VFD along with distribution panel in enclosure for motor rating of 100 HP. Enclosure shall be IP54. The panel shall be equipped with MCCB TP with suitable rating, Spreader link TP, Extended rotary handle, Volt meter digital, Volt selector switch, Amp meter, Amp selector switch, C.T with suitable rating, Control MCB SP with suitable rating, PLA Relay, Push button red plus green with element, Indicator ON/Off, Aluminium Bus bar/suitable rating power and Control wiring labour and margin, Fabrication with minimum Sheet thickness of 2 mm for load bearing and non-load bearing side. VFD should be capable of protecting motor from high and low voltage and earth fault as well. VFD should restrict harmonics up to 35% VFD should be capable of providing starting torque up to 200% while starting motor. It should have class 3C3 (Avg)conformal coating so that components are safe from dust and moisture. Communication -Built-in RS485 Modbus RTU, Ambient Temperature -Heavy Duty: -10 ~ 50 deg C Normal Duty: -10 ~ 40 deg C, PCB Protection Conformal Coating complying to IEC 60721-3-3 class 3C3, Application Humidity Below relative humidity 95% RH (no condensation) Altitude 0 to 1,000 m Without deration 1,001 to 4,000 m With deration of 1% per rise in 100 m, Vibration Up to 9.8 m/sec2 (1.0 G), Global Compliance CE, UL, RoHS, Control Method V/F Control, Sensorless Vector Control, Slip Compensation, Closed Loop Vector Control. Starting Torque 200% at 0.5Hz in Sensorless Vector Control and 150% at 3Hz in V/F, Frequency Control Range 0 to 400Hz in V/F, 0 to 300Hz in Sensorless 1, 0 to 120Hz in Sensorless 2 / Vector, Frequency Precision Setting- Digital: 0.01Hz, Analog: 0.03Hz (60Hz Base). complete with all other accessories as required. [For BCR Pump Chamber, Clear water P/M for Zone 1,4,5 and 3,4,5 ]. | 11 | Each | 2,55,335 ₹28.1 L | 3,00,000 ₹33 L | 3,05,000 ₹33.5 L |
| 8.00 | Design, Supply, installation and testing of VFD along with distribution panel in enclosure for motor rating of 60 HP. Enclosure shall be IP54. The panel shall be equipped with MCCB TP with suitable rating, Spreader link TP, Extended rotary handle, Volt meter digital, Volt selector switch, Amp meter, Amp selector switch, C.T with suitable rating, Control MCB SP with suitable rating, PLA Relay, Push button red plus green with element, Indicator ON/Off, Aluminium Bus bar/suitable rating power and Control wiring labour and margin, Fabrication with minimum Sheet thickness of 2 mm for load bearing and non-load bearing side. VFD should be capable of protecting motor from high and low voltage and earth fault as well. VFD should restrict harmonics up to 35% VFD should be capable of providing starting torque up to 200% while starting motor. It should have class 3C3 (Avg)conformal coating so that components are safe from dust and moisture. Communication -Built-in RS485 Modbus RTU, Ambient Temperature -Heavy Duty: -10 ~ 50 deg C Normal Duty: -10 ~ 40 deg C, PCB Protection Conformal Coating complying to IEC 60721-3-3 class 3C3, Application Humidity Below relative humidity 95% RH (no condensation) Altitude 0 to 1,000 m Without deration 1,001 to 4,000 m With deration of 1% per rise in 100 m, Vibration Up to 9.8 m/sec2 (1.0 G), Global Compliance CE, UL, RoHS, Control Method V/F Control, Sensorless Vector Control, Slip Compensation, Closed Loop Vector Control. Starting Torque 200% at 0.5Hz in Sensorless Vector Control and 150% at 3Hz in V/F, Frequency Control Range 0 to 400Hz in V/F, 0 to 300Hz in Sensorless 1, 0 to 120Hz in Sensorless 2 / Vector, Frequency Precision Setting- Digital: 0.01Hz, Analog: 0.03Hz (60Hz Base). complete with all other accessories as required. [For B/S No. 3] | 2 | Each | 1,97,335 ₹3.9 L | 2,30,000 ₹4.6 L | 2,33,325 ₹4.7 L |
| 9.00 | Design, Supply, installation and testing of VFD along with distribution panel in enclosure for motor rating of 75 HP. Enclosure shall be IP54. The panel shall be equipped with MCCB TP with suitable rating, Spreader link TP, Extended rotary handle, Volt meter digital, Volt selector switch, Amp meter, Amp selector switch, C.T with suitable rating, Control MCB SP with suitable rating, PLA Relay, Push button red plus green with element, Indicator ON/Off, Aluminium Bus bar/suitable rating power and Control wiring labour and margin, Fabrication with minimum Sheet thickness of 2 mm for load bearing and non-load bearing side. VFD should be capable of protecting motor from high and low voltage and earth fault as well. VFD should restrict harmonics up to 35% VFD should be capable of providing starting torque up to 200% while starting motor. It should have class 3C3 (Avg)conformal coating so that components are safe from dust and moisture. Communication -Built-in RS485 Modbus RTU, Ambient Temperature -Heavy Duty: -10 ~ 50 deg C Normal Duty: -10 ~ 40 deg C, PCB Protection Conformal Coating complying to IEC 60721-3-3 class 3C3, Application Humidity Below relative humidity 95% RH (no condensation) Altitude 0 to 1,000 m Without deration 1,001 to 4,000 m With deration of 1% per rise in 100 m, Vibration Up to 9.8 m/sec2 (1.0 G), Global Compliance CE, UL, RoHS, Control Method V/F Control, Sensorless Vector Control, Slip Compensation, Closed Loop Vector Control. Starting Torque 200% at 0.5Hz in Sensorless Vector Control and 150% at 3Hz in V/F, Frequency Control Range 0 to 400Hz in V/F, 0 to 300Hz in Sensorless 1, 0 to 120Hz in Sensorless 2 / Vector, Frequency Precision Setting- Digital: 0.01Hz, Analog: 0.03Hz (60Hz Base). complete with all other accessories as required. [At Main Water Works for Raw water pump and Clear water pump for Zone No. 1 and 2 ]. | 4 | Each | 1,97,335 ₹7.9 L | 2,50,000 ₹10 L | 2,52,325 ₹10.1 L |
Tender Value
₹11.7 Cr
EMD Value
₹23.3 L
Closing Date
28 Nov 2025, 3:00 pmClosed
ADARSH KUMAR SINGLA
Tohana PHED
Providing and Laying Distribution Pipeline in balance area and Replacement of Pipeline, Supply and Errectioning of Pumping sets of Balancing Capacity Reservoir, Installing of IOT at Various Installations of water supply schemes of Ratia Town District
2025_HRY_481819_1
20254440D8A0 E833 4D9E 81CE 2D3022ABC0F3585PUH
Open Tender
Civil Works
360 days
Ratia Ratia
2 documents required · 2 mandatory
₹20,000
₹23.3 L
Yes
21 Jan 2026
7 Nov 2025
28 Nov 2025
7 Nov 2025
28 Nov 2025
7 Nov 2025
7 Nov 2025 - 28 Nov 2025
Amount
Works Details
Supply ,Erection, Testing and Commissioning of Horizontal Split Casing Raw Water Pumping Set with CI Body SS Impeller Gland Pack duly coupled to Suitable rating of Motor 1440 RPM on a common Base Plate -Discharge -15300 LPM X 15 m Head
SIM Card for Five year operation of all the instrument above as required.
Supply, Installation, testing, Commissioning with Maintenance of five year of Radar and Water Level Transmitter along with according to water level in OHSR (for OHSR) Ingress Protection – IP 66, Measuring range – Up to 20 M, Process temp.- -40 to 60 deg. C, Full PVDF Body – For a long sensor lifetime **Unit Rate given, actual quantity to be ascertained while placing order
Functional Integration at RTU-cum- Gateway for Motorized Control Valve in Pump Control Panel. With five year maintenance.
Supply of Water Meter inclusive all taxes.
Providing Fixing with Five-year maintenance of CI D/F SLUICE VALVE PN 1.0 WITH ACTUATOR (AT BCR MWW and BS 1) 300 mm i/d
Providing Fixing with Five-year maintenance of CI D/F SLUICE VALVE PN 1.0 WITH ACTUATOR (At main Water works on suction and delivery of Clear water pumping sets for Zone No. 1 and 2 and all B/S) 250 mm i/d
Providing Fixing with Five-year maintenance of CI D/F SLUICE VALVE PN 1.0 WITH ACTUATOR (At main Water works and B/S 2,4) 450 mm i/d
Providing Fixing with Five-year maintenance of CI D/F SLUICE VALVE PN 1.0 WITH ACTUATOR (At main Water works) 600 mm i/d
Providing Fixing with Five-year maintenance of CI D/F SLUICE VALVE PN 1.0 WITH ACTUATOR (At main Water works and BCR) 700 mm i/d
Providing Fixing with Five-year maintenance of CI D/F SLUICE VALVE PN 1.0 WITH ACTUATOR (At B/S 1 and 2) 350 mm i/d
Providing Fixing with Five-year maintenance of CI D/F SLUICE VALVE PN 1.0 WITH ACTUATOR (At different installation) 200 mm i/d
NS Item -For ultrasonic Flow meter: with Maintenance of five year UF series intrusive Ultrasonic Flow Meter (MID Certified) UF-1520-1202-01 ( At Inlet channel)
NS Item -Electromagnetic Flow meter with Maintenance of five year of Intrusive type Electromagnetic (At main water works Rising Main 1) 450 mm i/d.
NS Item -Electromagnetic Flow meter with Maintenance of five year of Intrusive type Electromagnetic (At main water works Rising Main 2) 350 mm i/d.
NS Item -Electromagnetic Flow meter with Maintenance of five year of Intrusive type Electromagnetic (At B/S no. 2 outlet) 500 mm i/d.
NS Item -Electromagnetic Flow meter with Maintenance of five year of Intrusive type Electromagnetic (At B/S no. 1 and 3 for inlet) 200 mm i/d.
NS Item -Electromagnetic Flow meter with Maintenance of five year of Intrusive type Electromagnetic (At B/S no. 3 and 5 for outlet) 400 mm i/d.
NS Item -Electromagnetic Flow meter with Maintenance of five year of Intrusive type Electromagnetic (At BCR PC TO SS TANK ) 700 mm i/d.
Supply and Erection with actuator Sluice Gate Size: 2400 MM x 1200 MM Cast Iron wall thimble mounted sluice gates , Flush bottom closure With five year maintenance.
Supply and Erection with actuator Sluice Gate Size:1200 MM x 600 MM Cast Iron wall thimble mounted sluice gates , Flush bottom closure With five year maintenance.
Supply, Installation, testing, Commissioning with Maintenance of five year of Pressure Transmitter along with its installation complete in all respect as per specifications. Measuring range – 10 kg/cm2, Output – 4 to 20 mA, to be installed at tail end/remote location (For Main Water Works, BCR and 5 Boosting Stations)
NS Item -`Cloud based software comprising of Middleware, Database and Front-end web interface through suitable Dashboards, Aggregation screens and GIS assisted drill-down from macro to micro to be provided. Application data hosting and maintenance for Five years included in scope. Cloud services of Ministry of Electronics and Information Technology (Meity), Government of India empaneled cloud service providers shall be taken like Microsoft, Amazon, Google, BSNL etc. Cloud service provider must adhere the security standards and guidelines issued by Meity from time to-time. As the data belongs to the State Government of Haryana, therefore the application and data hosted on Cloud must be kept and stored in data centres located in India only. Any change in application requirement or infrastructure shall be borne by the Implementation agency. Implementation agency shall carry out the Application Security Audit from a Certified Auditor (CA). Application and data shall be kept confidential and only the authorized users shall have the access to it. Implementation Agency shall be responsible for any data theft or data leakages (At main water works)
Supply, Installation, Testing, Commissioning with Maintenance of five year of Online Chlorine Sensor to be installed at Pump End/Source.(Main Water Works, Balancing capacity Reservoir and all 5 Boosting Stations)
Providing and fixing C.I. sluice valves (with cap) complete with bolts, nuts, rubber insertions etc. (the tail pieces if required will be paid separately) : 400 mm i/d
Providing and fixing C.I. sluice valves (with cap) complete with bolts, nuts, rubber insertions etc. (the tail pieces if required will be paid separately) : 450 mm iu/d
Providing and fixing C.I. sluice valves (with cap) complete with bolts, nuts, rubber insertions etc. (the tail pieces if required will be paid separately) : 350 mm i/d
Providing and fixing C.I. sluice valves (with cap) complete with bolts, nuts, rubber insertions etc. (the tail pieces if required will be paid separately) : 500 mm i/d
Bidder Name
Amount
M/S SHREE BALAJI BUILDERS (GSTN-NA) BID ID -1376326
Himmat Singh Contractor (GSTN-NA) BID ID -1376144
Rajesh Kadiyan Contractor (GSTN-NA) BID ID -1373000
Himmat Singh Contractor (BID ID -1376144)
Rajesh Kadiyan Contractor (BID ID -1373000)
Himmat Singh Contractor (BID ID -1376144)
M/S SHREE BALAJI BUILDERS (BID ID -1376326)
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.94 MB
BOQ_559803.xls
BOQ • 0.33 MB
777957Z121363.pdf
Additional Documents • 0.56 MB
Other Document
Other Document • 0.96 MB
Download all tender documents and submit your bid