| 1 | L1₹25.9 LAccepted-AOC 42 43A VIDYA SAGAR SARANI PALLY BARISHA KOLKATA 700 008 | KOLKATA | WEST BENGAL | 700008 | ₹25.9 L Quoted ₹26.2 L | L1 | Accepted-AOC Being lowest and reasonable |
| 2 | L2₹41.9 L+₹15.7 L (60.1%)Rejected-Finance | ₹41.9 L+₹15.7 L (60.1%) | L2 | Rejected-Finance Other than lowest |
| 3 | L3₹41.9 L+₹15.7 L (60.1%)Rejected-Finance 121004 | ₹41.9 L+₹15.7 L (60.1%) | L3 | Rejected-Finance Other than lowest |
| 4 | L3₹41.9 L+₹15.7 L (60.1%)Rejected-Finance | ₹41.9 L+₹15.7 L (60.1%) | L3 | Rejected-Finance Other than lowest |
| 5 | L4₹42.3 L+₹16.2 L (61.8%)Rejected-Finance GC ROAD ABDUL LATIF ROAD PO TITAGARH KOLKATA 700119 | 24 PARAGANAS NORTH | WEST BENGAL | 700119 | ₹42.3 L+₹16.2 L (61.8%) | L4 | Rejected-Finance Other than lowest |
Tender Value
₹36.8 L
EMD Value
₹73,600
Closing Date
19 Dec 2020, 6:00 pmClosed
GE (FW) Kolkata
D-9 COMMISSARIAT ROAD HASTINGS KOLKATA 700022
REPAIR/MAINTENANCE OF POWER FACTOR PANEL, ACB, ATS, LT PANEL, LT FEEDER PILLAR BOX, EARTHING AND LIGHTNING ARRESTOR AT FORT WILLIAM UNDER GE (FW) KOLKATA
2020_MES_382411_2
GE(FW)/8685/E8
Open Tender
Electrical and Maintenance Works
Item Rate
330 days
Fort William Kolkata
Refer tender documents
6 documents required · 6 mandatory
₹500
Yes
GE (FW) Kolkata
₹73,600
Yes
13 Jan 2021
11 Dec 2020
21 Dec 2020
11 Dec 2020
19 Dec 2020
12 Dec 2020
Amount
Isolating of Power factor panels, of any capacity, from the main supply and checking of the panels installed at various locations and testing their operation and mechanical system including detection and replacement of the unserviceable parts/ accessories required at site to make the Power Factor Panel completely functional including cleaning/ servicing of complete unit and re-connection of the panel complete all as specified and directed. (Note :- Provision of new spare parts as required shall be measured and paid separately under relevant supply only items here-in-after)
Supply only capacitor duty contactors, 5 kVAr Rating @ 440V, 3Ph, 50Hz (MAKE: L&T, Cat No: CS96127 or equivalent item in other makes specified in tender)
Supply only capacitor duty contactors, 10 kVAr Rating @ 440V, 3Ph, 50Hz (MAKE: L&T, Cat No: CS96156 or equivalent item in other makes specified in tender)
Supply only capacitor duty contactors, 15 kVAr Rating @ 440V, 3Ph, 50Hz (MAKE: L&T, Cat No: CS90019 or equivalent item in other makes specified in tender)
Supply only capacitor duty contactors, 20 kVAr Rating @ 440V, 3Ph, 50Hz (MAKE: L&T, Cat No: CS90021 or equivalent item in other makes specified in tender)
Supply only capacitor duty contactors, 25 kVAr Rating @ 440V, 3Ph, 50Hz (MAKE: L&T, Cat No: CS96322 or equivalent item in other makes specified in tender)
Supply only capacitor duty contactors, 30 kVAr Rating @ 440V, 3Ph, 50Hz (MAKE: L&T, Cat No:CS96148 or equivalent item in other makes specified in tender)
Supply only capacitor duty contactors, 50 kVAr Rating @ 440V, 3Ph, 50Hz (MAKE: L&T, Cat No:CS96324 or equivalent item in other makes specified in tender)
Supply only self healing type capacitor, 3 phase, 440 volts, 50 Hz, Box type of Capacity 5 KVAr complying with following specifications:- (i) Overcurrent withstand capacity upto 1.5 X In (ii) Peak Inrush current withstand capacity upto 200 times (iii) Operating losses not more than 0.45 W /kVAr (iv) No. of switching per year = 5000 (v) Max ambient temperature = 55 degree C (vi) Operating life = 1,00,000 hours
-ditto- but of capacity 10 kVAr
-ditto- but of capacity 15 kVAr
-ditto- but of capacity 20 kVAr
-ditto- but of capacity 25 kVAr
Supply only self healing type capacitor, 3 phase, 440 volts, 50 Hz, Box type of Capacity 10 KVAr complying with following specifications:- (i) Overcurrent withstand capacity upto 1.8 X In (ii) Peak Inrush current withstand capacity upto 300 times (iii) Operating losses not more than 0.35W /kVAr (iv) No. of switching per year = 8000 (v) Max ambient temperature = 55 degree C (vi) Operating life = 1,50,000 hours
-ditto- but of capacity 15 kVAr
-ditto- but of capacity 20 kVAr
-ditto- but of capacity 25 kVAr
Supply only self healing type capacitor, 3 phase, 440 volts, 50 Hz, Box type of Capacity 10 KVAr complying with following specifications:- (i) Overcurrent withstand capacity upto 3 X In (ii) Peak Inrush current withstand capacity upto 500 times (iii) Operating losses not more than 0.35 W /kVAr (iv) No. of switching per year = 20000 (v) Max ambient temperature = 70 degree C (vi) Operating life = 3,00,000 hours
-ditto- but of capacity 15 kVAr
-ditto- but of capacity 20 kVAr
-ditto- but of capacity 25 kVAr
-ditto- but of capacity 30 kVAr
-ditto- but of capacity 50 kVAr
NOTE FOR ITEM NO. 11 TO 23:- (1) List of approved makes has been provided in particular specifications. Contractor shall ensure that capacitor provided comply with the aforesaid specifications. No claim shall be entertained during currency of work.)
Supply only PVC insulated copper conductor cable 16.0 Sqmm single core 1100 volts grade
Supply only PVC insulated copper conductor cable 10.0 Sqmm single core 1100 volts grade
Supply only APFC relay 8 steps 3 CT complete (Make: L&T, Cat No: ETACONM008R / LEGRAND, Cat No: 415197 / BCH, Cat No: RG-8T-415 or equivalent model in other makes specified in tender)
Supply only APFC relay 12 steps 3 CT complete (Make: L&T, Cat No: ETACONM008R + ETACONEXP2R + ETACONEXP2R / BCH, Cat No: RG-12T-415 or equivalent model in other makes specified in tender)
Supply and fixing in repair Automatic transfer switch open execution type, 415V, 3 phase 4 pole 100 Amps with Controller unit to be fixed on existing panel board incl taking down of existing switch complete all as specified and directed. (Make: HAVELLS, Cat No: IHYFCDO100 or equivalent model in other makes specified in tender)
Supply and fixing in repair Automatic transfer switch open execution type 415V, 3 phase 4 pole 200 Amps with Controller unit to be fixed on existing panel board incl taking down of existing switch complete all as specified and directed. (Make: Havells, Cat No IHYFCDO200 or equivalent model in other makes specified in tender)
Supply and fixing in repair Automatic transfer switch open execution type 415V, 3 phase 4 pole 315 Amps with Controller unit to be fixed on existing panel board incl taking down of existing switch complete all as specified and directed. (Make: Havells, Cat No: IHYFCDO315 or equivalent model in other makes specified in tender)
Supply and fixing in repair Automatic transfer switch open execution type 415V, 3 phase 4 pole 400 Amps with Controller unit to be fixed on existing panel board incl taking down of existing switch complete all as specified and directed. (Make: Havells, Cat No: IHYFCDO400 or equivalent model in other makes specified in tender)
Supply and fixing in repair Automatic transfer switch open execution type 415V, 3 phase 4 pole 630 Amps with Controller unit to be fixed on existing panel board incl taking down of existing switch complete all as specified and directed. (Make: Havells, Cat No: IHYFCDO630 or equivalent model in other makes specified in tender)
Supply and fixing in repair of Air circuit breaker 4 pole 415 volts, 50 kA manual draw out type with thermal magnetic release of capacity 800 Amps including all necessary accessories and taking out existing unserviceable ACB complete all as specified and dierected. (Make: L&T, Cat No: SL95352OOOO / C&S, Cat No: AHA08N4PMDTM(S) or equivalent model in SCHNEIDER / ABB / HAVELLS / INDO ASIAN (OPTI POWER) / BCH)
Supply and fixing in repair of Air circuit breaker 4 pole 415 volts, 50 kA manual draw out type with thermal magnetic release of capacity 630 Amps including all necessary accessories and taking out existing unserviceable ACB complete all as specified and dierected. (Make: L&T, Cat No: SL95351 / C&S, Cat No: AHA06N4PMDTM(S) or equivalent model in SCHNEIDER / ABB / HAVELLS / INDO ASIAN (OPTI POWER) / BCH)
Isolating the device and checking of LT ACBs 630-800 Amps capacity and testing its operation and tripping devices and mechanical system and setting it right clearing / servicing complete unit and recharging complete in position for Air Circuit Breaker of Make- GE , L&T, Crompton Greaves, Legrand or Schneider. Note :- (a) Checking and repairing work will be done by concerned company representative or OEM authorised person only. (b) New spare parts as required shall be measured and paid separately).
Supply only accessories / spares for Air Circuit Breaker 630 - 800 Amps rating of Make : GE, L&T, Crompton Greaves , Legrand or Schneider.
Aux contact block 3 NO 3 NC
Micro switch for unserviceable trip indication
Phase barrier 3P
Trip indication switch
Neutral CT 630A
Neutral CT 800A
Shunt Trip/Closing Coil (415V)
Earth fault relay 3 phase 3 wire
Mechanical Interlock
Fixed Arcing contact 3P
Moving Arcing contact 3P
Supply and fixing in repair 50 mm bore galvanized iron pipe (light grade) with all fittings, laid in trenches or fixed complete to wall / ceiling or laid in floor complete all as specified and as directed by the Engineer-in-charge.
M&L for PCC (1:2:4) type B-1 using 20 mm graded crushed stone aggregate as in coping of poles / pipes / strip alignment etc using necessary formwork and finishing the exposed surfaces even and smooth without using extra cement, as directed by the Engineer-in-Charge.
M&L for PCC (1:3:6) type C-2 using 20 mm graded crushed stone aggregate as in foundation filling and mass concrete complete all as specified and directed.
S&F in repair air termination, single pointed aluminium rod, 12 mm dia and 300 mm long, fixed on GI pipes with earthing strips for earth coductivity to ground complete all as specified and directed. (NOTE: GI pipe & earthing strip shall be measured and paid seperately)
S&F in repair test point terminal block, made of gun metal or phosporous beonze of size 75 mm X 75 mm X 25mm, drilled and screwed including 3 Nos, 8 mm dia and 25 mm long hex screws complete all as specified and directed.
S&F in repair earth contuinity conductor with aluminium strips of size 25 mm X 3 mm, fixed to wall/on batten/recess/chases/ buried in ground/drawn in conduit or pipes/fixed to poles/ from top of the OH tank to test point or any other indicated situation for loop earthing etc complete all as specified and directed. (NOTE: Porcelain insulators for fixing of strip shall be measured and paid seperately)
S&F in repair copper strip 20 mm X 3.15 mm with saddles and fixing screws etc, for roof conductors and down conductors above ground complete all as specified and directed. (NOTE: Porcelain insulators for fixing of strip shall be measured and paid seperately)
S&F porcelain insulators of size 50 mm with fixing arrangements complete all as specified and directed.
Materials and Labour for earthing complete with galvanized steel earth plate electrode 600 mm x 600 mm x 6.0 mm thick buried directly in ground vertically to a depth not less than 2.25 meter deep below ground level with top edge earth plate at a depth not less than 1.5M below normal ground level connected to galvanized iron strip 32 X 6 mm (upto 7.5 metres) by means of bolts, nuts check nuts and washers of galvanized steel and connected to main switch board or main control board as directed and including provision of concrete pit in PCC (1:3:6) type C1, pre-cast RCC (1:2:4) type B1 cover slab 45 cm x 45 cm x 5 cm reinforced with 8 mm dia. TMT bars @ 150 mm centre to centre both ways, with one handle for lifting made out of 8 mm dia MS bar, provision of funnel, wire mesh, 20 mm bore galvanized steel tubing (Medium grade) for watering, charcoal or coke and salt in alternate layers, 40 mm bore galvanized steel tubing medium grade for protection of earth lead connection, necessary excavation and earth work in any type of soil and including necessary testing and dismantling of existing unsv earthing complete all as shown in Figure 15A of IS 3043 :1987, complete all as specified and directed.
Supply and fixing in repair On load change over switch, 415V, 3 phase 4 pole 400 Amps, open execution type, staggered terminals, interchangeble dual shaft position with site convertability Confirming to IEC 60947-3, incl taking down existing unserviceable change over switch complete all as specified and directed.
Supply and fixing in repair On load change over switch, 415V, 3 phase 4 pole 250 Amps, open execution type, staggered terminals ,interchangeble dual shaft position with site convertability Confirming to IEC 60947-3, incl all accessories and taking down of existing unserviceable switch complete all as specified and directed. (MAKE: L&T, Cat No: CO32500OOOO / C&S, Cat No: CSCS250NM4CO / HAVELLS, Cat No: IHCNFE0250 / INDO ASIAN, Cat No: ICAE0250 / HPL, Cat No: C02504POAV)
Supply and fixing in repair On load change over switch, 415V, 3 phase 4 pole 200 Amps, open execution type, staggered terminals ,interchangeble dual shaft position with site convertability Confirming to IEC 60947-3, incl all accessories and taking down of existing unserviceable switch complete all as specified and directed. (MAKE: L&T, Cat No: CO22000OOOA/C&S, Cat No: CSCS200NM4CO / HAVELLS, Cat No: IHCNFE0200 / INDO ASIAN, Cat No: ICAE200 / HPL, Cat No: C02004POAV)
Taking down old unserviceable Feeder Pillar box/ LT Panel and Supply, install, commissioning and testing in replacement cubical type outdoor type Bus bar junction box, made out of 3.15 mm thick mild steel sheet, of size not less than 850 mm x 750 mm x 550 mm, fabricated in CPRI approved factory with mild steel angle iron frame and legs (of length 300 mm) of section 40 mm x 40 mm x 6 mm thick, with front openable door (with locking arrangement) duly powder coat painted over a coat of red oxide primer dust and vermin proof with provision of cable entry and exit at mid portion of the feeder pillar box (with cable gland), and providing one number Danger Notice Plate (of size 15 cm x 10 cm, suitable for LT line, made out of 0.6 mm thick mild steel sheet, vitreous enamelled white, with letters, figures and conventional skull and bones in signal red colour, fixed with clamps and nuts-bolts of suitable size) and providing necessary foundation of the feeder pillar box in PCC (1:3:6) type C-2 (using 40 mm graded crushed stone aggregate) complete all as directed by the Engr-in-Charge comprising of the following accessories :-
Copper bus bar 630 Amps (size 40mm x 10mm x 400mm) capacity - 4 Nos
LED indicating Lamp with holder for main & standby supply indicating RYB (Set of three) - 01 Set
MCCB (Incoming) 125 Amps, 4 Pole, 25 KA, Ics= 100% of Icu - 01 No (Make : L&T, Cat No - CM90642OOLO / LEGRAND, Cat No: 420056 / C&S, Cat No: CSE1M125ATM4P-125 / HAVELLS, Cat No: IHDA6OBF0125 or equivalent model in SCHNEIDER / ABB / INDO ASIAN (OPTI POWER) / HAGER)
MCCB (Outgoing) 63 Amps, 4 Pole, 16 KA, Ics= 100% of Icu - 02 Nos (Make : L&T, Cat No - CM90518OOHO / LEGRAND, Cat No: 420013 / HAVELLS, Cat No: IHDA3BBF0063 or equivalent model in SCHNEIDER / ABB / HAGER / INDO ASIAN (OPTI POWER)/ C&S)
Note:-(i) All incoming and out going cables, duly thimble along with suitable size of brass cable glands, to be connected to accessories. (ii) All MCCB & Changeover to be connected internally with suitable size of copper strip.
Taking out unserviceable LT panel board/feeder pillar (of any size) and Supply, install, commissioning and testing of outdoor type LT panel board, cubical type, dust and vermin proof, made out of 3.15 mm thick CRCA sheet of size 1300 mm x 900 mm x 550 mm, fabricated in CPRI approved factory with front and back openable door (with locking arrangement) and making compartment for each MCCB/change over switch separately, duly painted with two coats of synthetic enamel paint over a coat of red oxide zinc chrome primer inclusive of 04 Nos aluminium bus bar of section 50 mm x 6 mm (of adequate length), for three phase and neutral system, fixed over and including 4 nos insulators, pre-wired with PVC insulated stranded copper conductor (of adequate size), all incoming / outgoing connection to be made with copper lugs & copper strips, with provision of cable entry and exit at mid portion of the panel board (with cable gland),and two numbers Danger Notice Plate (of size 20 cm x 15 cm, suitable for LT line, made out of 0.6 mm thick mild steel sheet, vitreous enamelled white, with letters, figures and conventional skull and bones in signal red colour, fixed with angle iron frame with base 50X 50X 6 mm with legs not more then 60 cm including grouting with P C C complete including earthing all as directed by the Engr-in-Charge including supply and fixing of the following accessories :-
MCCB (incoming) with thermal-magnetic release of capacity 400 Amps, 4 pole, 50HZ, 36 KA, Ics= 100% of Icu - 01 No. (Make: L&T, Type DN3-630D, Cat No - CM94106OOS1OG / LEGRAND, Cat No: 4220 07 / HAVELLS, Cat No: IHBA9EMF0400 / C&S, Cat No: CSE3M400ATM4P_400 or equivalent model in SCHNEIDER / ABB / INDO ASIAN (OPTI POWER) / HAGER)
MCCB (Outgoing) with thermal-magnetic release of capacity 160 Amps, 4 pole, 50HZ, 36 KA, Ics= 100% of Icu - 2 Nos. (Make : L&T, Cat No - CM92108OOM1OG / LEGRAND, Cat No: 4200 97 / HAVELLS, Cat No: IHB1HELF0160 / C&S, Cat No: CSCN250TM1604P or equivalent model in SCHNEIDER / ABB / INDO ASIAN (OPTI POWER) / HAGER)
MCCB (Outgoing) with thermal-magnetic release of capacity 100 Amps, 4 pole, 50HZ, 36 KA, Ics= 100% of Icu - 2 Nos. (Make : L&T, Cat No - CM92108OOL1OG / LEGRAND, Cat No: 420095 / HAVELLS, Cat No: IHBA6ELF0100 / C&S, Cat No: CSC3S4100 or equivalent model in SCHNEIDER / ABB / INDO ASIAN (OPTI POWER) / HAGER)
LED indicating Lamp with holder for main supply & standby supply indicating RYB (Set of three) - 01 Set
Note:-(i) All incoming and out going cables, duly thimble along with suitable size of brass cable glands, to be connected to accessories. (ii) All MCCB & Changeover to be connected internally with suitable size of copper strip.
ESS PEE UDYOG
S. K. CONSTRUCTION SYNDICATE AND ENGINEERING CO.
GHOSH ENTERPRISE
KWALITY CONSTRUCTION
M A ENTERPRISES
M/s Qureshi Construction Co
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .