| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹33.8 LAccepted-AOC | L1 | Accepted-AOC Lowest | |
| 2 | L2₹40.9 L+₹5.2 L (14.5%)Rejected-Finance | L2 | Rejected-Finance Other than lowest | |
| 3 | L3₹41.4 L+₹5.6 L (15.8%)Rejected-Finance 212 B 8 PARDEWANPUR LAL BANGLA KANPUR 208007 | KANPUR | KANPUR NAGAR | UTTAR PRADESH | 208007 | L3 | Rejected-Finance Other than lowest | |
| 4 | L4₹46.2 L+₹10.4 L (29.3%)Rejected-Finance | L4 | Rejected-Finance Other than lowest | |
| 5 | L5₹48.6 L+₹12.9 L (36.1%)Rejected-Finance | L5 | Rejected-Finance Other than lowest |
| Sl No | Description | Qty | Unit | m/s A.A brothers L1 | PAWAN COOL CORPORATION L4 | BRITE INDUSTRIES L5 | keerti trading corporation L2 | santosh electronics L3 | JASPREET SINGH COOLING CORP. L6 |
|---|---|---|---|---|---|---|---|---|---|
| 1.00 | M & L for servicing of package type indoor unit of capacity 5.5/8.75/11/16.5 TR by opening front grill, bottom grill cleaning filters, by spraying water jet, removing dust/dirt from package unit all over, checking electric connection, checking any leakage by applying soap solution on joint & liquid/vapour lines properly checking functionality of all spares & replacing the same under relevent item of schedule & put the air conditioner into operation. complete all as specified and directed by Engr-in- charge.
Note :
(i) Spare parts will be measured and paid separately.
(ii) Sliding the filter out and washing it with water and drying in the shade, reinstalling the same.
(iii) Checking the compressor for oil leakage and inspection of vibrations insulation rubber for wear and tightening the mounting lugs. | 45 | Each Job | 1,500 ₹67,500 | 925 ₹41,625 | 500 ₹22,500 Lowest | 1,000 ₹45,000 | 3,500 ₹1,57,500 | 1,700 ₹76,500 |
| 2.00 | -ditto- all as per item No-1 but outdoor unit of package unit of capacity 5.5/8.75/11/16.5 TR . | 45 | Each Job | 1,000 ₹45,000 | 975 ₹43,875 | 500 ₹22,500 Lowest | 1,000 ₹45,000 | 3,500 ₹1,57,500 | 1,800 ₹81,000 |
| 3.00 | S&F blower motor 5.5 TR package unit complete testing and commissioning complete all as specified and directed. Make of copper wire as approved by GE. | 25 | Each Job | 1,000 ₹25,000 | 4,275 ₹1,06,875 | 500 ₹12,500 Lowest | 3,000 ₹75,000 | 4,100 ₹1,02,500 | 5,000 ₹1,25,000 |
| 4.00 | S&F Blower assembly 5.5 TR complete all as specified and directed. | 20 | EACH | 1,500 ₹30,000 | 2,475 ₹49,500 | 500 ₹10,000 Lowest | 500 ₹10,000 Lowest | 2,500 ₹50,000 | 3,000 ₹60,000 |
| 5.00 | S & F in replacement of AC, single phase, 220V, 50 Hz Condensor fan motor 1/3 to 1/2 HP suitable for 5.5 TR package out door unit. | 20 | Each | 4,000 ₹80,000 | 3,645 ₹72,900 | 150 ₹3,000 Lowest | 1,800 ₹36,000 | 2,200 ₹44,000 | 5,000 ₹1,00,000 |
| 6.00 | S & F in replacement of Filter dryer with flare nut suitable for package AC of Make - Blue Star / Emersion/Catch oil / Danfoss | 25 | Each | 1,000 ₹25,000 | 1,165 ₹29,125 | 650 ₹16,250 Lowest | 750 ₹18,750 | 1,100 ₹27,500 | 1,200 ₹30,000 |
| 7.00 | S&F in replacement of thermostatic expansion valve 5.5 TR suitable for Refrigerent R 22 of 11TR operated package AC unit complete all as specified and as directed. MAKE DANFOSS / EMERSON | 20 | Each | 3,000 ₹60,000 | 4,875 ₹97,500 | 2,300 ₹46,000 Lowest | 3,000 ₹60,000 | 4,700 ₹94,000 | 5,500 ₹1,10,000 |
| 8.00 | S&F in replacement of thermostatic expansion valve 5.5 TR suitable for Refrigerent R 407C of 16.5TR operated package AC unit complete all as specified and as directed. MAKE DANFOSS / EMERSON | 10 | Each | 1,500 ₹15,000 Lowest | 5,275 ₹52,750 | 2,500 ₹25,000 | 3,000 ₹30,000 | 6,000 ₹60,000 | 6,000 ₹60,000 |
| 9.00 | Supply and fixing in replacement of Liquid line valve,5.5 TR of size 1/2 inch or of suitable size as per sample and testing the systemleakproof before and after fixing of new valve.
Make:DANFOSS / EMERSON | 15 | Each | 300 ₹4,500 | 975 ₹14,625 | 1,500 ₹22,500 | 250 ₹3,750 Lowest | 1,050 ₹15,750 | 1,600 ₹24,000 |
| 10.00 | Supply and fixing in replacement of Liquid line valve,5.5 TR of size 5/8 inch or of suitable size as per sample and testing the systemleakproof before and after fixing of new valve.
Make:DANFOSS / EMERSON | 15 | Each | 200 ₹3,000 Lowest | 1,125 ₹16,875 | 1,500 ₹22,500 | 250 ₹3,750 | 1,250 ₹18,750 | 1,600 ₹24,000 |
Tender Value
₹50 L
EMD Value
₹1 L
Closing Date
6 Feb 2026, 6:00 pmClosed
Col Manav Pant, CWE
HQ CWE (AF) Chakeri, Kanpur - 208008
REPAIR MAINT OF PACKAGE AIR CONDITIONER AT VARIOUS LOCATION IN TECH AREA AND REPAIR MAINT OF VALVES DUCT PIPELINE AND DESCALING CLEANING OF COOLING TOWER AND MISC CONNECTED WORK OF CENTRAL AC PLANT AT AFS CHAKERI KANPUR
2026_MES_748560_1
CANO. CWE(AF)/CHK/EM/T-41 OF 2025-26
Open Tender
Electrical and Maintenance Works
Item Rate
270 days
GE(AF) E/M CHAKERI
Please refer tender documents
8 documents required · 8 mandatory
₹500
GE (AF) E/M Chakeri
₹1 L
29 Apr 2026
14 Jan 2026
14 Feb 2026
14 Jan 2026
6 Feb 2026
29 Jan 2026
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1 | M & L for servicing of package type indoor unit of capacity 5.5/8.75/11/16.5 TR by opening front grill, bottom grill cleaning filters, by spraying water jet, removing dust/dirt from package unit all over, checking electric connection, checking any leakage by applying soap solution on joint & liquid/vapour lines properly checking functionality of all spares & replacing the same under relevent item of schedule & put the air conditioner into operation. complete all as specified and directed by Engr-in- charge.
Note :
(i) Spare parts will be measured and paid separately.
(ii) Sliding the filter out and washing it with water and drying in the shade, reinstalling the same.
(iii) Checking the compressor for oil leakage and inspection of vibrations insulation rubber for wear and tightening the mounting lugs. | 45 | Each Job | - | - |
| 2 | -ditto- all as per item No-1 but outdoor unit of package unit of capacity 5.5/8.75/11/16.5 TR . | 45 | Each Job | - | - |
| 3 | S&F blower motor 5.5 TR package unit complete testing and commissioning complete all as specified and directed. Make of copper wire as approved by GE. | 25 | Each Job | - | - |
| 4 | S&F Blower assembly 5.5 TR complete all as specified and directed. | 20 | EACH | - | - |
| 5 | S & F in replacement of AC, single phase, 220V, 50 Hz Condensor fan motor 1/3 to 1/2 HP suitable for 5.5 TR package out door unit. | 20 | Each | - | - |
| 6 | S & F in replacement of Filter dryer with flare nut suitable for package AC of Make - Blue Star / Emersion/Catch oil / Danfoss | 25 | Each | - | - |
| 7 | S&F in replacement of thermostatic expansion valve 5.5 TR suitable for Refrigerent R 22 of 11TR operated package AC unit complete all as specified and as directed. MAKE DANFOSS / EMERSON | 20 | Each | - | - |
| 8 | S&F in replacement of thermostatic expansion valve 5.5 TR suitable for Refrigerent R 407C of 16.5TR operated package AC unit complete all as specified and as directed. MAKE DANFOSS / EMERSON | 10 | Each | - | - |
| 9 | Supply and fixing in replacement of Liquid line valve,5.5 TR of size 1/2 inch or of suitable size as per sample and testing the systemleakproof before and after fixing of new valve.
Make:DANFOSS / EMERSON | 15 | Each | - | - |
| 10 | Supply and fixing in replacement of Liquid line valve,5.5 TR of size 5/8 inch or of suitable size as per sample and testing the systemleakproof before and after fixing of new valve.
Make:DANFOSS / EMERSON | 15 | Each | - | - |
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.53 MB
TENDERT4182467.pdf
Tender Documents • 1.32 MB
BOQ_838305.xls
BOQ • 1.22 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .