Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹21.9 LAccepted-AOC DAKRA RANCHI PIN 829201 | CHATRA | JHARKHAND | 829201 | L1 | Accepted-AOC Awarded | |
| 2 | L2₹22.0 L+₹10,002 (0.46%)Rejected-Finance 00 C O LAKHAN LAL AGRAWAL RATU ROAD NEAR KABLISTHAN RANCHI JHARKHAND 834001 | RANCHI | JHARKHAND | 834001 | L2 | Rejected-Finance Financially not evaluated | |
| 3 | Rejected-Technical 4C 1 KESHAR VIHAR NEAR NSF INTER COLLEGE BALAJI PURAM SHAHGANJ AGRA 282010 | AGRA | UTTAR PRADESH | 282010 | - | Rejected-Technical Technically not qualified |
Tender Value
₹20.0 L
EMD Value
₹25,100
Closing Date
28 Apr 2025, 9:00 amClosed
SO(EnM), Kathara Area
office of General Manager, Kathara ARea
CAMC of A, B and MQ type residential quarters (Staff and Russian Colony, Teachers Colony, Gayatri Colony, CnD Colony, MRS and CPP Colony) for a period of two years under GM Unit of Kathara Area.
2025_CCL_334214_1
GM(KTH)/EnM/E-Tender/25-26/01
Open Tender
AMC WORKS
Item Rate
730 days
Kathara Area
As per NIT
2 documents required · 2 mandatory
₹25,100
7 Jul 2025
17 Apr 2025
29 Apr 2025
18 Apr 2025
28 Apr 2025
18 Apr 2025
18 Apr 2025 - 22 Apr 2025
Amount
Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with piano type switch, phenolic laminated sheet, suitable size M.S. box and earthing the point with 1.5 sq.mm. FRLS PVC insulated copper conductor single core cable etc. as required. Group-A
Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with piano type switch, phenolic laminated sheet, suitable size M.S. box and earthing the point with 1.5 sq.mm. FRLS PVC insulated copper conductor single core cable etc. as required. Group-B
1.15Rewiring fo rlight point/fan point/exhaust fan point/call bell pointwith1.5 sq.mm FRLS PVC insulated copper conducto rsingle core cable and 1.5sq.mm FRLS PVC insulated copper conductor single core cable as earth wire in existing surface/recessed steel/PVC conduit including dismantling as required. (Group-B)
Supplying and fixing following piano type switch/socket on the existing switch box/ cover including connections etc. as required. 5/6 A Switch
Supplying and fixing following piano type switch/socket on the existing switch box/ cover including connections etc. as required.5/6Amps. Socket outlet
Supplying and fixing following piano type switch/socket on the existing switch box/ cover including connections etc. as required.15/16 Amps Switch
Supplying and fixing following piano type switch/socket on the existing switch box/ cover including connections etc. as required.15/16 Amps Socket
Supplying and fixing of modular type electronic regulator Supplying & fixing stepped type electronic fan type regulator on the existing modular plate switch box including connection but excluding modular plate etc. as required.
Supplying and fixing 5Ato32A rating,240/415V, 10kA,"C"curve, miniature circuit breaker suitable for inductive loadof followingpoles in the existing MCB DB complete with connections, testing and commissioning etc. as required.
Supplying and fixing 3 pin, 5A ceiling rose on the existing junction box/wooden block including connections etc. as required.
Supplying and fixing PVC batten/ angleholder including connections etc. asrequired
Supplying and fixing metal box of following sizes(nominal size)on surface or in recess with suitable size of phenolic laminated sheetcover infront including painting etc. as required( 200 mm X 250 mm X 60 mm deep)
Wiring for circuit/sub main wiring along with earth wire with the following sizes of PVC insulated copper conductor, single Core cable in surface/recessed PVCConduit as required (2x1.5Sq.mm+ 1.5sq.mm earth wire)
Checking of fault and re-connection of existing service wire for restoration of power.
Checking of fault and re-connection of inside quarter for restoration of power.(Without Material).
Supplying and fixing metal box of 180mm X 100mm X 60mm deep (nominal size) on surface or in recess with suitable size of phenolic laminated sheet cover in front including providing and fixing 6 pin 5/6 & 15/16 amps socket outlet and 15/16 amps piano type switch, connection, painting etc. as required.
2.14 Supplying and fixing following rating, double pole,(single phase and neutral), 240V, residual current circuit breaker(RCCB), having a sensitivity current 30 mA in the existing MCBDB complete with connections,testingand commissioning etc. as required. 25A
Providing and fixing following capacity TP&N disconnector fuseswitch unitinsidetheexisting panel boardwith ISI marked HRCfusesincludingdrillingholes in cubicle panel, making connections, etc. asrequired for (32A TP&N) (For Single Quarter)
Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface/ recessed steel/ PVC conduit as required. 2 x4 sq. mm For Service Wire
Supplying and laying 6 SWG G.I. wire at 0.50 metre below ground level for conductor earth electrode, including connection/ termination with GI thimble etc. as required. Details of cost for 1 Metres
Earthing with G.I. earth plate 600mm x 600mm x 6mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7mtr. long etc. with charcoal/coke and salt asrequired.
Laying of one number PVC insulated and PVC sheathed /XLPEpowercableof1.1 KVgradeof following size in the existing RCC/ HUME/METAL pipeasrequired (Upto 35 sq. mm)
Total impact of GST for the purpose of CTC
M/S PRAVEEN KUMAR (BID ID -1149730)
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .