| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | 1₹21.5 LAccepted-AOC | ₹21.5 L Quoted ₹32.5 L | 1 | Accepted-AOC L1 |
| 2 | 2₹35.7 LRejected-AOC | ₹35.7 L | 2 | Rejected-AOC L2 |
| 3 | Rejected-Technical 4 13A PERIYAR NAGAR THANGAMAPURIPATTINAM METTUR DAM 636 402 | SALEM | TAMIL NADU | 636402 | - | - | Rejected-Technical BQR condition 1 is Not satisfied |
| Sl No | Description | Qty | Unit | R.K.V. ENTERPRISES L1 | M/s. KSR Enterprises L2 |
|---|---|---|---|---|---|
| 1.00 | Inspection / cleaning and assembling of CEP strainer Assembly. | 12 | Nos | 1,46,880 ₹1.7 L | 1,56,000 ₹1.8 L |
| 2.00 | Caission inspection, rectification, renewal of parting plane gasket and substitution of MC Pump. | 2 | Nos | 1,29,200 ₹1.5 L | 1,36,000 ₹1.6 L |
| 3.00 | Inspection and rectification of thrust and guide bearing and mechanical seal of main condensate pump | 6 | Nos | 3,54,000 ₹4.2 L | 3,66,000 ₹4.3 L |
| 4.00 | Renewal of drive end bearing, mechanical seal of drip pump. KSB WKS125/7 | 2 | Nos | 34,200 ₹40,356 | 36,000 ₹42,480 |
| 5.00 | Renewal of Non drive end bearing, mechanical seal in drip pump | 2 | Nos | 26,000 ₹30,680 | 30,000 ₹35,400 |
| 6.00 | Renewal of Non drive end bearing in drip pump | 4 | Nos | 4,400 ₹5,192 | 48,000 ₹56,640 |
| 7.00 | Renewal of drive end bearing in drip pump | 4 | Nos | 40,000 ₹47,200 | 42,000 ₹49,560 |
| 8.00 | Decoupling the drip pump from motor and aligning the Drip pump with the motor and coupling | 6 | Nos | 54,000 ₹63,720 | 59,400 ₹70,092 |
| 9.00 | Decoupling the MC pump from motor ad Aligning the MC Pump with Motor and coupling | 6 | Nos | 84,000 ₹99,120 | 90,000 ₹1.1 L |
| 10.00 | Removal of oil spillage around Nine numbers MC Pump And six number drip pumps and attending gland leak in regenerative system valves. | 284 | Nos | 7,10,000 ₹8.4 L | 7,38,400 ₹8.7 L |
Tender Value
Refer Docs
EMD Value
₹21,300
Closing Date
31 Dec 2025, 2:00 pmClosed
CE/TTPS
Chief Engineer, Tuticorin Thermal Power Station, Tuticorin 628004.
TTPS Mech II TM I Unit I II III Inspection and Cleaning of suction strainer caisson inspection Rectification of thrust bearing, Breakdown works of MC Pumps Drip Pumps and Air compressors for the period from 01 04 2026 to 31 03 2027
2025_EB_632373_1
CE/TTPS/SE/M-II/No.17/2026-27
Open Tender
Miscellaneous Works
365 days
TTPS
As per BQR conditions in NIT
8 documents required · 8 mandatory
₹0
₹21,300
Yes
23 Mar 2026
15 Dec 2025
2 Jan 2026
15 Dec 2025
31 Dec 2025
15 Dec 2025
Inspection / cleaning and assembling of CEP strainer Assembly.
Caission inspection, rectification, renewal of parting plane gasket and substitution of MC Pump.
Inspection and rectification of thrust and guide bearing and mechanical seal of main condensate pump
Renewal of drive end bearing, mechanical seal of drip pump. KSB WKS125/7
Renewal of Non drive end bearing, mechanical seal in drip pump
Renewal of Non drive end bearing in drip pump
Renewal of drive end bearing in drip pump
Decoupling the drip pump from motor and aligning the Drip pump with the motor and coupling
Decoupling the MC pump from motor ad Aligning the MC Pump with Motor and coupling
Removal of oil spillage around Nine numbers MC Pump And six number drip pumps and attending gland leak in regenerative system valves.
Inspection and rectification of LP Cylinder in air compressor
Inspection and rectification of HP Cylinder in air compressor
Dismantling, overhauling and assembling of suction and delivery valves -24 Nos cleaning and DE-carbonizing the spring plates, cushion plates valve plates etc and assembling back, conducting leak test with kerosene/Diesel. (For LP Cylinder)
Dismantling, overhauling and assembling of suction and delivery valves -24 Nos cleaning and DE-carbonizing the spring plates, cushion plates valve plates etc and assembling back, conducting leak test with kerosene/Diesel. (For HP Cylinder)
Charges for Cleaning of After Filter & Pre Filter of Drier, Changing the Filter if required.
Dismantling / Assembling the Inter Cooler or After Cooler bunch then checking for leakage & plugging the leak tubes. Inclusive of Hydro test
Removal of oil spillage around 14 Nos instrument air compressors and service air compressors, cleaning the oil filter /suction air filter and blocked drain cock in air compressors system
M/s. KSR Enterprises (BID ID -1550353)
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.28 MB
BOQ_756563.xls
BOQ • 0.30 MB
Download all tender documents and submit your bid