Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹23.2 LAccepted-AOC | L1 | Accepted-AOC L1 Accepted | |
| 2 | L2₹24.5 L+₹1.0 L (4.44%)Rejected-AOC | L2 | Rejected-AOC Other than L1 | |
| 3 | L3₹25.7 L+₹2.3 L (9.63%)Rejected-AOC | L3 | Rejected-AOC Other than L1 | |
| 4 | L4₹26.6 L+₹3.1 L (13.4%)Rejected-AOC | L4 | Rejected-AOC Other than L1 | |
| 5 | L5₹26.8 L+₹3.3 L (14.3%)Rejected-AOC | L5 | Rejected-AOC Other than L1 |
Tender Value
₹40 L
EMD Value
₹80,000
Closing Date
9 Feb 2024, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Garrison Engineer
Garrison Engineer (North) Akhnoor- 181201 C/o 56 APO
CERTAIN REPAIR TO ROOF AND CONNECTED WORKS INCLUDING MAINTENANCE OF EXTERNAL WALL OF BUILDING UNDER EAST ZONE AT AKHNOOR UNDER GE (NORTH) AKHNOOR
2024_MES_637212_1
CANO- GE(N)/AKH-58/2023-2024
Open Tender
Support/Maintenance Service
Item Rate
180 days
Akhnoor
Class D category a(i)
9 documents required · 9 mandatory
₹500
GE (North) Akhnoor
₹80,000
Yes
18 Jun 2024
12 Jan 2024
16 Feb 2024
12 Jan 2024
9 Feb 2024
26 Jan 2024
Amount
Demolition / taking down of existing old tarfelt , water proofing membrane, water proofing plaster of any description any type over RCC roof including any roof tiles, cement mortar screed, concrete screed of any thickness, for fixing of angle iron for water tank postion, incuding making good the surface by concrete to smooth surface complete all as specified and as directed.
Rendering 15 mm thick in cement and sand mortar 1:4 on roof slab to receive roof treatment including finishing the surface fair and even complete all as specified and as directed.
Supply only liquid water proofing compound conforming to IS 2645-1975 of approved make complete all as specified and directed.(Dosage- @ 200ml per 50Kgs of Bags of cement)
Roof treatment :- Water proofing treatment to RCC roof slab including parapet as under :- (a) Ist Course : Apply a coat of bituminous primer conforming to IS-3384@ 0.40 Kg /Sqm on prepared surface of plaster and after drying of primer, apply a coat of hot blown 85/25 grade bitumen conforming to IS-702 @ 1.2 Kg/sqm on plastered surfaces. (b) 2nd Course : APP (Atactic Polypropylene) modified polymeric membrane, 5 layered, 3 mm thick weight not less than 3.0 Kg/Sqm with 160 Grams/Sqm non woven polyester made at centre core reinforced laid with 75 mm side overlap and 150 mm end overlap, membrane has to be laid with LPG torch and overlap sealed and finished neat, all joints. (c) 3rd Course : Apply a coat of hot blown 85/25 grade bitumen conforming to IS-702 @ 1.2 Kg/sqm over membrane and dusted with dry sand @ 0.50 to 1 Kg/sqm. (i) On Non-accesible roof : After providing (a) to (c) provide aluminium paint as per manufacturer instructions. contd to item No-4.01
(ii) Coved fillet in PCC 1:2:4 type B0 (using 12.5 mm graded crushed stone aggregate) of required radius 75mm shall be provided at the junction of roof and vertical surface such as parapet wall/mumty around opening and treatment mentioned above shall be applied followed by a cement plaster 20mm thick in cement mortar(1:6). Note : (i) Roof treatment work shall be carried out through approved manufacturers only or through their authorised personal only.
PCC 1:2:4, type, B-1 (using 20mm graded crushed stone aggregate), as in coping, benching, levelling course including rounded or chamfered angle as directed including necessary form work etc., complete all as specified and directed.
Dismantling structural steel work including doors, gates but excluding framed truss etc., complete all as specified and as directed by Engineer-in-Charge.
Dismantling asbestos cement (corrugated, semi corrugated) sheets including ridges as in roof covering, complete all as speciified and directed.
Demolition of cement concrete (un-reinforced) in ground floors and paving not exceeding 15cm thickness (below or above ground level), complete all as specified and as directed.
Dismantling of wall and ceiling boards (fibre, pulp, insulation etc) of any type and any thickness including cover fillets/GI grid frame work complete all as specified and directed.
Rolled mild steel works as in roof trusses (framed), trussed, purlins, crane gantries, rails and fastenings and heavy bracket framing (beam,tee,angle, channel or flat sections) including distance pieces, cleats etc Fe 410W(Gde E-250), quality 'A' complete all as specified and as directed.
Mild steel framed work such as grills, gratings, etc. with ends of bars shouldered and/or riveted, or forged into spikes; framed guard bars; barred iron doors; ladders; framed balusters; walk ways; railings; framework of water tanks and similar work conforming to Fe.290.Gde-E-165, complete all as specified and as directed.
Preparation of new or previous un-treated steel surfaces of any description not otherwise described, over 10cm width or girth and applying two coats of synthetic enamel paint of Ist quality over a coat of red oxide primer, complete all as specified and as directed.
Pre- painted galvalume aluminum zinc coating GI based corrugated steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws, complete all as specified and as directed.
Pre- painted galvalume aluminum zinc coating GI based corrugated steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as ridges roof covering/cladding to wall, fixed with self tapping screws, complete all as specified and as directed.
4mm thick prelaminated designer ceiling board over & including GI snap grid frame work (Grid size 600x600mm) with powder coated GI angle of size 25x25x3mm fixed along wall perimeter, main runner 'T' of size 25x40x3mm , secondary runner 'T' of size 25x30x3mm suspended with 3mm GI wire @ 1200mm c/c of ceiling by fasteners of adjustable guide hanger including clips/MS fitments to hold the panels, complete all as specified and as directed.
PVC (SWR) pipes 150mm dia any length single socketed with rubber ring joint laid in trenches/floors or fixed to wall in repairs, complete all as specified and directed.
PVC (SWR) pipes 110mm dia any length single socketed with rubber ring joint laid in trenches/floors or fixed to wall in repairs, complete all as specified and directed.
PVC (SWR) bends any radius of 150mm dia complete all as specified and directed.
PVC (SWR) bends any radius of 110mm dia complete all as specified and directed.
Demolition of brick or stone masonry, built in cement mortar including all quoins, arches, pillars etc but excluding ashlars facings, dressed stone work, complete all as specified and directed.
Brick work with sub class ‘B’ bricks straight or curved on plan exceeding 6m mean radius built in cement mortar 1:6, complete all as specified and directed.
Taking down cement plaster of any description on stone or brick walls etc. including racking out joints, hacking for key scrubbing down with water etc.complete all as specified and directed.
Repair to balcony/facia and soffit of chajjas etc by taking down old plastered surfaces and hacking clearly the edges and corners smooth and rounded for new plastered area exceeding 30sqcm in width or girth & applying rendering 15 mm thick dubbing coat where required to match with the existing thickness in CM 1:4 including formwork/scaffolding work upto height 7.00mtr above ground level of bldg complete all as specified and as directed.
Rendering 15mm thick cement plaster with cement mortar(1:4) with mixing of water proofing compound.(WPC shall be measured and paid seperately) on fair faces of brickwork or concrete surfaces and finished even and smooth without using extra cement complete all as specified and directed.
Rendering 15mm thick cement plaster with cement mortar (1:6) on other than fair faces of brick work or stone masonry surfaces & finishing the surface even and smooth without using extra cement, complete all as specified and directed.
Rendering 10mm thick cement plaster with cement mortar (1:4) on concrete surfaces as in ceiling & finishing the surface even and smooth without using extra cement, complete all as specified and directed.
Preparation of old painted surfaces with complete removal of existing treatment & applying two coats of 100% Premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives @ 1.43 litre/ 10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/ 10 sqm on wall complete all as specified and directed.
Preparation of newly plastered surfaces & applying two coats of 100% Premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance,dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives @ 1.43 litre/ 10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/ 10 sqm on wall, complete all as specified and directed. Note for item No-27 & 28:- (i) The work shall be carried out in different shade and the same shall be got approved from Engineer-in-charge/GE/ (ii) The work shall be carried out upto 4th storey of bldgs and no extra payment shall be admissible for necessary form work & scaffolding required for the same.
Preparation of newly plastered surfaces of walls and applying two coats of distemper oil emulsion on walls over a coat of approved primer complete all as specified and as directed.
Preparatrion of newly plastered and unplastered surfaces of walls and applying two coat of cement based paint over alkali resistant priming paint, complete all as speicfied and directed.
Preparation of newly plastered surfaces of ceiling and applying three coats of white wash, complete all as specified.
Preparation of old painted surfaces by washing, rubbing down and stopping of plastered surfaces and applying one coats of cement base paint white or tined on wall complete all as specified and as directed.
Disconnecting existing tanks of any description exc 500 litres but n.exc 1000 litres capacity, setting aside (or lowering if required) for repairs, cleaning, etc. and hoisting if required reconnecting and re-fixing in position, (after cleaning repairing, etc.), complete all as specified and as directed.
Disconnecting existing tanks of any description exc 1000 litres but n.exc 2000 litres capacity, setting aside (or lowering if required) for repairs, cleaning, etc. and hoisting if required reconnecting and re-fixing in position, (after cleaning repairing, etc.), complete all as specified and as directed.
Ball valves, high pressure of PTMT with epoxy coated aluminium rod & high density plastic ball, screwed for iron pipe 20 mm dia (minimum weight 210 gms) fixed in repairs, complete all as specified and as directed.
Taking up or down steel tubing of 15mm bore pipe and connection laid in trenches or floors or fixed to walls and including cleaning for refixing or removal to store with all fittings, complete all as specified and directed.
Description all as per srl Item No-36 above, but 20 mm bore.
Steel water tubing of 15 mm bore ‘medium grade’ galvanized with all fittings like socket, union, elbow, bend, tees etc fixed to walls and ceilings or laid in floors, complete all as specified and as directed.
Description all as per srl Item No-38 above, but bore of pipe 20mm .
Refixing of old steel tubing and connections in new or old position on walls, ceiling or floors etc of size 15 mm bore after cleaning including provn of new fittings, complete all as directed.
Description all as per item No.40 above but 20 mm bore.
20mm bore gun metal glove or gate valve with iron wheel head screwed bith end for iron pipe and fixed in repairs, complete all as specified and as directed.
Complete removal of old existing treated surface of wall including cleaning surfaces and applying two coat of cement based paint, complete all as speicfied and directed.
Preparation of new plastered/ untreated surface of wall and applying two coats of plastic emulsion paint over one coat of primer white or tinted over a coat of 2mm thick wall care putty complete all as specified and directed.
Complete removal of old existing treated surface of wall including cleaning surface and applying two coats of plastic emulsion paint white or tinted over one coat of primer white or tinted over a coat of 2mm thick wall care putty complete all as specified and directed.
Preparation of old plastered surfaces of ceiling and applying two coats of white wash complete all as specified and directed.
Complete removal of existing old treatment of walls upto plaster level with mechanical means including cleaning, washing, rubbing etc. and applying two coats of exterior emulsion paint (wheather proof Apex paint only) over a coat of approved primer over 2mm thick wall care putty complete all as specified and directed. Note : 1. Rate to be quoted shall be inclussived for all materials, puttty and mechanical means/ equipments, scaffolding upto 4th story of bldg. 2. Complete removal of putty, primer and Apex painting will be done by skilled painter only. 3. Colour and sample code will be approved by GE.
Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing) and removing rubbish off premises complete all as specified and as directed by Engineer-in-Charge.
Vitrified ceramic tiles (Light shade) 10mm thick (square /rectangular) polished, area of each tile n.exceeding 0.36 sqm laid as in floors, set and jointed in neat cement slurry and pointed in white/coloured cement to match with shade of tiles including 15mm thick screed bed/base in cement and sand mortar 1:4, complete all as specified.
Description all as per Item No 49 above, but in skirting/dado over and including 10mm thick rendering in CM 1:4.
Providing plain cement concrete type C-1, 1:3:6 (using 20mm graded crushed stone aggregate), 50 mm thick as in plinth protection laid in bays not exceeding 2 Sqm each and finishing even and fair with 6mm wide joints throughout the thickness of plinth protection in concrete bays and in between the walling and plinth protection, filling the joints with mastic filling comprising of one part of heated bitumen 85/25 or 95/10 grade and 3 parts of sand (all by weight), complete all as specified and as directed.
20mm thick granite (of approved type colour) work (table rubbed & polished) in jambs, pillars, window cills, cooking plateform laid over and including 15mm thick cement screed (1:4) and jointed with grey cement slurry and pointed with white cement (1:2) with admixture of pigment to match the colour of granite stone including cutting and moulding the edges, complete all as specified.
M/s Rajesh Kumar Contractor
CHOPRA CONSTRUCTIONS
harish kumar and co
BALVINDER SINGH AND SONS
M/S KARAN SINGH CONTRACTOR
M/S Mahajan Construction Co.
NISHANT SHARMA
M/s Joginder Lal Malhotra
stage.html
html • 0.07 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .