| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹45.6 LAccepted-AOC P O WEST SRIPURIA DIST TINSUKIA ASSAM PIN 786 145 | TINSUKIA | ASSAM | 786145 | L1 | Accepted-AOC L1 bidder | |
| 2 | L2₹46.5 L+₹70,576.80 (1.54%)Rejected-Finance | L2 | Rejected-Finance Higher bid value | |
| 3 | L3₹47.6 L+₹1.8 L (3.88%)Rejected-Finance | L3 | Rejected-Finance Higher bid value | |
| 4 | L4₹48.3 L+₹2.5 L (5.50%)Rejected-Finance | L4 | Rejected-Finance Higher bid value | |
| 5 | L5₹50.4 L+₹4.6 L (9.99%)Rejected-Finance THE RETREAT NEAR LAKE BORDOLOI NAGAR P O TINSUKIA ASSAM PIN 786 125 D 69 CEEC | TINSUKIA | ASSAM | 786125 | L5 | Rejected-Finance Higher bid value |
Tender Value
₹43.7 L
EMD Value
₹87,400
Closing Date
5 Mar 2022, 6:00 pmClosed
GE DINJAN
GE DINJAN, PANITOLA (PO), DIBRUGARH (DIST), ASSAM
SPL REPAIRS TO DISPERSAL HARD STANDING AT ARMY AVN AND SPL REPAIRS TO DEPOT FENCING AT 2 MTN DOU AND CERTAIN REV AND MINOR WORKS AT DINJAN MIL STN UNDER GE DINJAN
2022_MES_506173_1
C/8379/E8
Open Tender
Civil Works
Item Rate
180 days
DINJAN MIL STN
AS PER TENDER DOCUMENT
10 documents required · 10 mandatory
₹500
GE DINJAN
₹87,400
Yes
16 Mar 2022
5 Feb 2022
7 Mar 2022
5 Feb 2022
5 Mar 2022
19 Feb 2022
Amount
Surface excavation averaging 15cm deep and not exceeding 30cm deep and getting out including removing same to a distance not exceeding 50 metre, depositing in soft/loose soil complete all as specified and as directed.
Excavation in trenches not exceeding 1.5 m wide and not exceeding 1.5 m in depth for foundation, etc area not exceeding 10 Sqm on plan and getting out in soft/loose soil complete all as specified and as directed.
Excavating in trenches not excdeening 1.5 metre wide and exceeding 1.5 metre & not exceeding 3 metre depth (beyond the first 1.5 metre) for foundation of poles etc and getting out in soft/loose soil complete all as specified and as directed.
Returning, filling in, including spreading in layers not exceeding 25cm, levelling, watering and well ramming as in soft/loose soil complete all as specified and as directed.
Removing excavated material to a distance not exceeding 50 m and depositing where directed at a level not exceeding 1.5 m above the starting point complete all as specified and as directed.
Excavating in post holes (or similar holes) each not exceeding 0.5 Cum, getting out, returning, filling in and ramming earth or broken rubble mixed with earth around, in layers not exceeding 25cm, watering and removing surplus soil to a distance not exceeding 50m and making good surface in soft/loose soil as directed.
M&L for plain cement concrete (1:4:8) type D-2 (using 40 mm graded stone aggregate) as in foundation, filling, sub base of floors and mass concrete, etc complete all as specified and as directed.
M&L for use and waste form work to sides of foundation, footings, bases of columns, plinth beams flat rough finished surfaces of concrete complete all as specified and as directed.
M&L for reinforced cement concrete (1:2:4) type B-1 (Nominal Mix) (Using 20 mm graded stone aggregate) as in foundation including footing, plinth beams, bases of column etc complete all as specified and as directed.
M&L for use and waste formwork to sides of pillars, posts, struts, piers, columns and stanchions for flat rough finished surfaces of concrete complete all as specified and as directed.
M&L for reinforced cement concrete (1:2:4) type B-1 (Nominal Mix) (Using 20 mm graded stone aggregate) as in columns, pillars, post and struts etc complete all as specified and as directed.
M&L for use and waste form work to soffits and sides of lintel beam, roof beam, cantilevers, shelvers, for flat rough finished surfaces of concrete complete all as specified and as directed.
M&L for reinforced cement concrete (1:2:4) type B-1 (Nominal Mix) (Using 20 mm graded stone aggregate) as in beam, lintel, cantilevers etc complete all as specified and as directed.
M&L for use and waste gorm work to soffits of suspended slabs such as roof slabs, floor slabs, landings and similar work; not exceeding 200 mm thick (horizonal or sloping) for flat rough finished surfaces of concrete complete all as specified and as directed.
M&L for reinforced cement concrete (1:2:4) type B-1 (Nominal Mix) (Using 20 mm graded stone aggregate) as in slabs supported on wall, roof beams etc complete all as specified and as directed.
M&L for use and waste formwork to edges of concrete flats, treads, breaks in floors, window cills, concrete railings, openings in concrete walls, floor and roofs not exceeding 20 cm wide and sides of RCC/PCC bands in walls, horizontal or sloping and similar work exceeding 10cm but not exceeding 20cm wide complete all as specified and as directed.
S&F for TMT steel bars 8mm dia., and over cut to length, bend to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9 mm dia or securing with clips quality complete all as specified and as directed.
S&F for TMT steel bars 10 mm dia., cut to length, bend to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9 mm dia or securing with clips quality complete all as specified and as directed.
S&F for TMT steel bars 6mm dia., and over cut to length, bend to shape required, including cranking, bending spirally as in nibs, stirrups, spacers and binders binding with and including providing mild steel wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified and as directed.
M&L for brick work using locally available first class bricks sub class 'B' bricks (old size brick), straight or curved on plan exc 6 m mean radius, built in cement mortar (1:6) complete all as specified and as directed.
M&L for brick work with sub class 'B' bricks, straight or curved on plan to any radius, built in cement mortar (1:4) as in half brick thick walls complete all as specified and as directed.
M&L for rendering 15 mm thick in cement mortar (1:6) on other than fair faces of brick masonry or concrete surfaces and finishing the surfaces even and smooth without using extra cement complete all as specified and as directed.
M&L for rendering 10 mm thick in cement mortar (1:4) on fair faces of brick masonry or concrete surfaces and finishing the surfaces even and fair without using extra cement complete all as specified and as directed.
M&L for rendering 5 mm thick in cement mortar (1:3) on concrete surfaces as in ceilings (sunshed, chajja etc) and finishing surfaces even and smooth without using extra cement complete all as specified and as directed.
M&L for preparing newly plastered surfaces of walls, etc and applying three coats of white wash complete all as specified and directed.
M&L for preparation of new plastered surfaces of ceiling and applying three coats of white wash complete all as specified and as directed.
M&L for preparation of newly plastered surfaces of walls and applying two coats of cement base paint over a coat of alkali resistant primer complete all as specified and as directed.
M&L for hardcore of gauge not exceeding 63 mm of broken stone or boulders, deposited, spread and levelled in layers not exceeding 15 cm thick, watered and rammed to a true surface complete all as specified and as directed.
M&L for 100 mm thick, plain cement concrete (1:4:8) type D-2 (using 40 mm graded stone aggregate) as in sub base etc complete all as specified and as directed.
M&L for 40 mm thick, plain cement concrete (1:2:4) type B-1 (using 20 mm graded stone aggregate) as in floors & finishing the surfaces even & smooth with using extra cement complete all as specified and as directed.
M&L for anodised aluminium section, medium anodic coating of grade AC 15 for frame of doors, windows, ventilators with one or more rebates including joining cleats for fixing etc complete all as specified and as directed.
M&L for anodised aluminium window and ventilator shutters, fixed type, with or without sash bar, using aluminium section weighing not less than 0.55Kg per metre including necessary joining cleats, glazing clips, rubber neoprene packing, aluminium handles 2 numbers in each shutter, hinges, anodised aluminium snap beading, screws etc complete all as specified and as directed.
S&F for solid PVC door frames of size 50mm x 47mm made out of 5mm plain colour PVC sheet reinforced with MS square tube complete all as specified and as directed.
S&F for factory made solid panel PVC door shutter 30 mm thick (style) consisting of frame made out of MS tubes for top & bottom rails. MS frame shall be covered with heat moulded, plain colour PVC 'C' channel having a PVC sheet strip of 20 mm width stuck inside with solvent cement for stiles and plain colour PVC sheets for top rail, lock rail & bottom rail on either side & as gap insert for top rail & bottom rail, panelling of plain colour 5mm thick PVC sheet to be fitted in the MS frame welded/sealed to the stiles & rails with suitable PVC sheet beading and jointed together with solvent cement, as per specification and drawing and as directed.
S&F for 100 mm long, stainless steel butt hinges fixed with stainless steel hinge pin etc complete all as specified and as directed.
S&F for 200 mm long, aluminium, barrel tower bolts of extruded section of aluminium alloy, anodised finish not be less than Grade AC 10 of IS 1868:1996 with transparent anodic film complete all as specified and as directed.
S&F for 125 mm size, aluminium handles, cast type, anodised to a bright natural, mat finish not be less than Grade AC 10 of IS 1868:1996 complete all as specified and as directed.
M&L for 25 mm thick, plain cement concrete (1:2:4) type B-0 (using 12.5 mm graded stone aggregate) as in sub-base of flooring, etc and finished the surface even and rough complete all as specified and as directed.
Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing) and disposing the rubbish off the premises complete all as specified and as directed.
M&L for non-skid, ceramic, coloured tiles 7 to 8 mm thick (square/ rectangular) area of each tile exceeding 0.06 sqm but not exceeding 0.11 sqm, in floors etc, including 15 mm thick screed bed in cement mortar (1:6) and set & jointed in neat cement slurry and pointed in white or coloured cement to match with the shade of tiles complete all as specified and as directed.
M&L for non skid coloured tiles 7 to 8mm thick (square/ rectangle) area of each tiles exceeding 0.11Sqm but not exceeding 0.18Sqm in floor etc. inciuding 15 mm thick cement mortar (1:6) screed bed or bedding layer set and joined in neat cement slurry and pointed in white or coloured cement to match complete all as specified and as directed.
M&L for non skid coloured tiles 7 to 8mm thick (square/ rectangle) area of each tiles exceeding 0.11Sqm but not exceeding 0.18Sqm in skirting, dado,etc inciuding 10 mm thick cement mortar (1:4) screed bed or bedding layer set and joined in neat cement slurry and pointed in white or coloured cement to match complete all as specified and as directed.
M&L for glazed, ceramic, coloured tiles of size 350mm x 450mm x 7mm thick, on vertical surfaces such as skirting, dados etc, including 10 mm thick bedding in cement mortor (1:4) and set & jointed in neat cement slurry & pointed in white or coloured cement to match with the shade of tiles complete all as specified and as directed.
M&L for 75 mm thick, plain cement concrete (1:3:6) type C-2 (using 40mm graded stone aggregate) as in footpath, plinth protection, etc, finishing cement concrete surface even and smooth without using extra cement including making joints with bitumastic filing in proportion of bitumen and sand (1:2) making impressions of expanded metal whilst the concrete is green complete all as specified and as directed.
M&L for machine pressed precast conctete interlocking paver block, glossy finish of approved colour, design & shape and size confirming to IS 15658-2006 of 60 mm thickness, M-35 Grade with grey cement and pigment including 75 mm thick compacted bed of coarse sand, filling the joints with fine sand etc. complete all as specified and as directed.
M&L for plain cement concrete (1:2:4) type B-1, (using 20 mm graded stone aggregate) as in lintel upto 1.5m span, cills and other similar band, plinth course, parapet, railing upto 60cm height, coping, kneelers, bed plates etc including weathering slightly rounded or chamfered angles including necessary form work complete all as specified and as directed.
S&F for 1000 litres capacity rotational moulded polyethylene water storage tanks (Cylindrical vertical with closed top) as per IS 12701:1996, hoisted and fixed in position including provision of 20/15mm bore medium grade pipe for connecting inlet, outlet, overflow and washout pipe all as specified in SSR Part I and as directed.
S&F for 20 mm bore, ball valves high pressure of PTMT with epoxy coated aluminium rod and high density plastic ball screwed for iron pipe and fixed. (Minimum weight - 210 gms) complete all as specified and as directed.
S&F for 20 mm bore, stop valves, cast copper alloy, screwed down, high pressure, with crutch or butterfly handle, screwed both ends for iron pipe or for unions complete all as specified and as directed.
Supply, laying, connection and testing, 20mm bore, CPVC pipes SDR 11 & plain CPVC SDR 11 including all fittings on walls/ceiling or laying in floors complete all as specified
Supply, laying, connection and testing, 25mm bore, CPVC pipes SDR 11 & plain CPVC SDR 11 including all fittings on walls/ceiling or laying in floors complete all as specified
Supply, laying, connection and testing, 32mm bore, CPVC pipes SDR 11 & plain CPVC SDR 11 including all fittings on walls/ceiling or laying in floors complete all as specified
Cutting chases, pinning in, making good to facings where required and pointing in cement mortar (1:3) to ends or edges of landings, steps, cills, sunshades, shelves, lintels, etc.; and cutting chases for concealed water tubing or concealed conduit wiring, etc., and making good, cutting exceeding 10 cm but not exceeding 20 cm girth complete all as specified and as directed.
S&F for 15 mm bore, stop valves, cast copper alloy, chromium plated, screwed down, high pressure, with crutch or butterfly handle, screwed both ends for iron pipe or for unions complete all as specified and as directed.
S&F for 15 mm bore, bib taps, cast copper alloy, chromium plated with crutch or butterfly handle, screwed down, screwed for iron pipe or for brass ferrule complete all as specified and as directed.
M&L for drilling and tapping cast iron water mains (in position) for branch connections of the internal dia 25/40/50mm complete all as specified and as directed.
S&F for swival shower of PTMT 15mm bore (minimum weight 40 gms) including shower arm 15mm size, 195mm long with bend of 45 degree with flange of PTMT any colour (minimum wt 40 gms) complete all as specified and as directed.
S&F for vitreous china wash basin, size 550 x 400mm, white, flat back, with PVC waste pipe, CP waste coupling, chain, plug and porcelean stopper & backets including cutting for and pinning in ends of brackets but excluding tap complete all as specified and as directed. Make : Cat No C0406 of Parryware /Hindware/ Cera.
S&F for 15 mm bore, pillar taps, fancy type, cast copper alloy, chromium plated with capstan heads, screwed down high pressure with or without lettered 'Hot or Cold' with long screwed shanks and fly nuts, screwed for iron pipe complete all as specified and as directed.
S&F for 15mm bore, PVC connection pipe 600mm long with PTMT nuts at both ends complete all as specified and as directed.
S&F for vitreous china squatting pan, 'Orissa' pattern, size 580 x 440 mm white with integral foot rest and 'P' or 'S' trap, including provision of lime concrete bedding, connection to trap and flushing pipe providing 110mm PVC WC connector etc complete including making good to disturbed surfaces of floor to match with existing specifications complete all as specified and as directed. Make : Cat No- C0117 of Parryware or equivalent.
S&F for semi-pedestal pattern (Anglow-Indian type), vitreous china water closet pan, white, with 'P' or 'S' trap, including flushing pipe, etc complete and making good to disturbed surfaces of floor by filling with PCC 1:4:8 type D-2 to match with the existings including taking down the existing old one complete all as specified and as directed.
S&F for 10 litre capacity, PVC valve less syphonic action type, flushing cistern, low level, white, with inlet, ball valve, flush pipe, float and handle including brackets complete all as specified and as directed.
S&F for PVC (SWR) pipes type 'B' 110mm bore, single socketed in any length with rubber ring joints laid in floors or trenches etc complete as required and as specified and as directed.
S&F PVC (SWR) pipes type 'B' 110mm bore, single socketed in any length with rubber ring joints fixed to walls using MS holder bat, fixed complete all as specified and as directed.
S&F for PVC (SWR) pipes type 'B' 75mm bore, single socketed in any length with rubber ring joints laid in floors or trenches etc complete all as specified and as directed.
S&F for 110 mm bore, PVC (SWR) bends of any radius complete all as specified and as directed.
S&F for 75 mm bore, PVC (SWR) bends of any radius complete all as specified and as directed.
S&F for 110mm bore, PVC (SWR) junction single, (single T) equal or unequal complete all as specified and as directed.
S&F for 75 mm dia outlet , PVC (SWR) floor trap, with grating including jointing to waste pipe fixed in cement concrete type B-1 (1:2:4) complete all as specified and as directed.
M&L for salt glazed stone ware drain pipes 150 mm bore, grade 'A' laid in trenches, jointed and tested complete all as specified and as directed.
M&L for plain cement concrete (1:3:6) type C-2 (using 40 mm graded stone aggragate) as in concrete bed to drain pipes including packing under and haunching against the sides of pipes after they are laid and tested for 100 mm bore SGSW drain pipes complete all as specified and as directed .
M&L for precast reinforced cement concrete (1:2:4) type B-1 (using 20 mm graded stone aggregate) as in cover slab of drain, etc and set in cement mortar (1:4) including necessary form, moulds, etc complete all as specified and as directed. Note : Reinforcement shall be measured and paid separately.
M&L for water proofing treatment on RCC roof etc. comprising with the following operation and as specified herein below and as directed:- (a) Taking down existing old tarfelt, bituminous compound including cleaning & removing debris to a distance exceeding 100m & not exceeding 250m. (b) 15 mm thick plastering in cement mortar (1:4) finished even & smooth. (c) Preparing & cleaning of fully dried cement plastered surface. (d) Applying one coat of cold bituminous primer to the plastered surface @ 0.25 liters per sqm conforming IS-3384 (e) A layer of APP based polymeric membrane membrane 3mm thick (minimum) weighing 3.5 kg per sqm reinforced with polyster non woven fabric (weighing not less than 160 gms/sqm )shall be applied over bituminous primer as specified above. Application of polymeric membrane shall be by torch application. The over lap shall be minimum 100 mm on transverse direction and 75 mm in longitudinal direction. (f) One coat of aluminium paint over the APP based membrane @ 0.11 Kg/Sqm
Dismantling posts or struts in normal ground (wood,steel or RCC) any section, including taking out embedded portion and making good disturbed ground.
Dismantling fencing wire mesh any type (barbed wire fence) complete all as specified and as directed.
S&F for mild steel angle posts and struts in fencing including cutting tops to shape as directed, drilling holes, notching for wire etc flat iron fillets ( for securing wire mesh etc) including all necessary drilling, bolting or riveting etc and similar work conforming to Fe-290, Gde E-165 complete all as specified and as directed.
S&F forhand rails, half round or other stock section or core for wooden hand-rail straight portion, drilled and countersunk for balusters running bars, for doors, balusters, nosing to steps including embeding in concrete and screwing etc. wind ties for roof including securing bolts; posts and struts in fencing including cutting tops to shape as directed, drilling holes, notching for wire, etc.; flat iron fillets (for securing wire mesh etc.) including all necessary drilling, bolting or riveting, etc., and similar work conforming to Fe-290 Gde E-165 complete all as specified and as directed.
Supply only chain link MS galvanised fencing any size or type as directed by Engr in charge.
Fixing only chain link fencing including line wires, any mesh, size and type of standard, rail straining bolts, etc including provision of binding wire as directed by Engr in charge.
S&F for mild steel screw bolts of 11 to 15mm dia of shank (machine made) with hexagonal or square heads at one end and screwed the other, or screwed both ends, each screwed end to be fitted with washers and one hexagonal or square nut, length of bolt not exceeding 10cm long complete all as specified and as directed.
S&F for galvanised 2 strand, steel barbed wire 2.24mm dia barbed with 2mm dia barbs at 75mm spacings and straining and fixing to any type of standard rails straining bolts, including, securing or tying at crossings with and provision of galvanised mild steel wire, staples or steel pins, etc. as directed (each line wire to be measured) complete all as specified and as directed.
M&L for mild steel round bar 10mm dia and over cut into length, bend to shape required including cranking bending spirally for hoping as in tie bar for fixing chain link fencing complete all as specified and as directed.
M&L for mild steel framed work as in doors or gates of angle or other section with gusset plates, rails, braces, etc., complete, drilled for fixing of steel sheeting or other covering, doors, etc. to be prepared for hanging or sliding with and including either hooks and hinges or steel hanging door fittings (exclusive of steel sheeting or other covering, running rails and guides) and hanging; also fastening and fixing complete conforming to Fe-290 (Gde E-165) complete all as specified and as directed.
M&L for preparation of new or previously untreated steel surfaces of any description, n.exc 10 cm width or girth when unconnected with other painting or when painted in different tint and applying two coats of synthetic enamel paint over a coat of red oxide, zinc chrome primer complete all as specified and as directed.
M&L for preparation of new steel surfaces of any description, over 10 cm in width or girth, not otherwise described and applying two coats of synthetic enamel paint over a coat of zinc chrome red oxide primer complete all as specified and as directed.
Demolition of cement concrete (unreinforced) of any description and in any position not other wise specifically provided complete all as specified and as directed.
M&L for pavement quality concrete (PQC) 200 mm thick of flexural strength 45 Kg per sq cm (lower control limit-LCL) after 28 days in pavement slab using minimum 450 Kg of cement per cubic metre and using non circular synthetic fibre @0.25 % by weight of cement with crushed stone aggregate of grading as per specification laid in panels including use and waste of necessary formwork for laying pavement concrete in bays between joints and contraction expansion joint/or between the two contraction joints spread and compacted using mechanical paver, mechanically vibrated and bull nosing/rounding off edges, curing, brooming, belting etc complete all as specified and as directed. NOTES :- (i)The rate of Polyester triangular synthetic fibre as secondary reinforcement mixed in cement concrete shall be included in quoted rate (ii) No price adjustment shall be applicable if more cement than minimum quantity of cement shall be used in the work.
Forming 25 mm thick expansion joint for full depth of PQC or concrete slab and filled with 20 mm thick pre-moulded compressible polythelene closed cell type filler board as specified and applying closed cell, medium density, cross linked polythelene/polysulphide based sealant, applying masking tape on edges of joint to prevent accidental spillage of sealant and removing the masking tape after filling of sealant all as per the direction of the manufacturer, complete all as specified and as directed.
Forming construction joint 25mm deep X 10mm wide using diamond cutter with closed cell, medium density, cross linked polythylene foam back up rod of 12 mm dia, for complete width of joint, priming top 10 mm with specifed primer and filling with polythelene/polysulphide based sealant, applying masking tape on edges of joint to prevent accidental spillage of sealant and removing the masking tape after filling of sealant as directed by the manufacturer, comlete all as specified and as directed.
M&L for preparing new concrete/ bituminous surface and Painting lines, dashes (continuous/un-interrupted), arrows, letters, etc on roads, pavement, and the like n.exc 10cm wide with two coats of waterbased road marking paint white or golden yellow over a coat of primer for the desired result complete all as specified and as directed.
M&L for concealed point wiring with 1.5 Sqmm (nominal area), FRLSH PVC insulated, multistranded, single core unsheathed, copper conductor cables passing through and including PVC conduit with all fittings and accessories of PVC conduit (like Tee, bend etc.) complete with and including 1.5 Sqmm (nominal area) FRLSH PVC insulated, unsheathed, stranded, single core, copper cable green in colour as earth continuity wire connecting to common earth point terminated in metal flush box of suitable size for mounting switches, sockets, regulators etc including cutting chases and making good by using cement mortar (1:4) complete for one light/fan/bell/buzzer point controlled by one ,one way switches complete all as specified and as directed.
S&F for switch piano, 5/6 Amp single pole, flush type one way 230 volts bearing ISI marked complete all as specified and as directed.
Supply, installing, testing and commissioning of Exhaust fan, suitable for Single Phase AC supply, earthing etc, 220/240 V, 300 mm sweep size, fan speed 950 RPM, 4 nos. blades, copper winding, Air delivery minimum 6500 CMM and including all fixing accessories complete all as specified and as directed. Make : Crompton/Bajaj as approved.
S&F for 20 W surface and wall mounted LED Battern with polycarbonate housing and intigrated electronic driver complete all as specified and as directed. Make : Cat part no: LUMILINEBS20WLED865SPCWH of Havells/Philips/Bajaj.
S&F for factory made board distribution (DB) Double Door in sheet steel enclosure with common bus bar at incomming end, SPN, 4 way, 240 Volts suitable for housing MCBs complete all as specified and as directed. Make : Cat No. DBDD04 of HPL/L&T/Havells.
S&F for MCB, 'C' Series, SPN, 240 Volts, 40 Amps, 'C' Series, 10KA capacity complete all as specified and as directed. Make : HPL/L&T/Havells.
S&F for MCB, 'C' Series, SP, 240 Volts, 6 to 32 Amps, 'C' Series, 10KA capacity complete all as specified and as directed. Make: Cat No. 408587 to 408595 of Legrand or equivalent.
M&L for sub main wiring with two run of 4 Sqmm (Nominal area) single core cable PVC insulated, multistranded, unsheathed, copper conductor cables (FRLSH), 1100 Volts grade drawn through PVC casing-caping/conduit of suitable size, fixed to wall/ceiling etc including one run of 4 Sqmm (nominal area) single core, PVC insulated, multistranded, unsheathed, copper conductor (FRLSH) as earth wire and duly connected to common earth point complete all as specified and as directed. Note : (a) PVC Casing-caping/conduit, two run wiring cables and one run of earth wire will be measured as one length. (b) All incoming and outgoing cable shall be connected by using proper lugs & sockets.
M&L for earthing complete with GI earth plate electrode 600 mm x 600mm x 6 mm thick burried directly in ground vertically to a depth not less than 2.25 m below ground level with the top edge of earth plate at depth not less than 1.5 m below ground level connected to galvanised earth lead wire 4.0 mm dia by means of bolts, nuts, check nuts and washers protected by 15mm bore light grade GI pipe, funnel with 20mm bore GI medium grade pipe for watering, wire mesh, including concrete pit in PCC (1:3:6) type C-1, pre-cast RCC 1:2:4 type B-1 cover slab of size 350x350x50mm reinforced with 8mm dia TMT steel bars @15cm centre to centre in both direction and 10mm dia MS handle of suitable size, charcoal or coke and salt in alternative layers,necessary earth work in soft/loose soil all as shown in Electrical Plate No 3 of MES Schedule Part I and testing complete inclduing taking down old one/ dismantling complete all as specified and as directed.
M&L for sand cushioning with dry clean sand 15cm below cable and 8cm above the cable complete all as specified and as directed. Note : Punned thickness shall be measured for payments.
M&L for bricks laid in trenches for LT cable protection with length of brick perpendicular to length of cable complete all as specified and as directed.
M&L for 32 mm bore, steel tubes, galvanised, light grade with all fittings, laid in floor/road crossing/drain etc as in UG cable protection complete to walls and ceilings or laid in floors complete all as specified and as directed.
M&L for 40 mm bore, steel tubes, galvanised, light grade with all fittings, laid in floor/road crossing/drain etc as in UG cable protection complete to walls and ceilings or laid in floors complete all as specified and as directed.
Boring hole below the road for pipe crossing upto 100mm bore, using trenchless technology complete all as directed. (Note: Cost of accessories required for making hole/bore deemed to be included in the quoted rate).
Supply, laying, jointing, testing and commissioning cross-linked polyethylene (XLPE) insulated, armoured, 2 core, nominal cross sectional area of main conductor 10 Sqmm, stranded aluminium conductor, ISI marked as per IS-7098 (Part-I) 1988 including cable glands, lugs etc to suit the cable size and to be laid in trenches, under floors, through GI Pipe complete all as specified and as directed. Note : (1) Pipes shall be measured and paid separately under relevant items of this schedule. (2) Excvation and earth work shall be measured and paid seperately.
Supply, laying, jointing, testing and commissioning cross-linked polyethylene (XLPE) insulated, armoured, 4 core, nominal cross sectional area of main conductor 10 Sqmm, stranded aluminium conductor, ISI marked as per IS-7098 (Part-I) 1988 including cable glands, lugs etc to suit the cable size and to be laid in trenches, under floors, through GI Pipe complete all as specified and as directed. Note : (1) Pipes shall be measured and paid separately under relevant items of this schedule. (2) Excvation and earth work shall be measured and paid seperately.
Supply, laying, jointing, testing and commissioning cross-linked polyethylene (XLPE) insulated, armoured, 4 core, nominal cross sectional area of main conductor 16 Sqmm, stranded aluminium conductor, ISI marked as per IS-7098 (Part-I) 1988 including cable glands, lugs etc to suit the cable size and to be laid in trenches, under floors, through GI Pipe complete all as specified and as directed. Note : (1) Pipes shall be measured and paid separately under relevant items of this schedule. (2) Excvation and earth work shall be measured and paid seperately.
M&L for steel tubular swaged poles complete with cast iron base plate, finial taper plug, bolts, nuts & screws as specified type 410 SP-31 (9.0 metres long) including two coats of aluminium paint over a coat of primer except the planting depth which shall be painted with black bituminous paint including writing pole number using suitable paint complete all as specified and as directed. Note : Excavation and Earth work, PCC filling shall be measured and paid separately.
M&L for cross arms bracing supports clamps and back plates fabricated from structural steel sections including nut bolt washers welding bending cold or hot drilling holes for bolts in any shape or size as indicated or directed and including one primer coat of red oxide zinc chrome primer, one under coat and one finishing coat of aluminium paint complete all as specified and as directed.
M&L for cement concrete (1:3:6) type C-1 (using 20 mm graded stone aggregate) as in foundation filling and mass concrete for street light pole and embedd the aviation light over the OHT complete all as specified and as directed.
S&F modular junction box made of SMC/FRP of size 240x130x110mm with provision of MCB SP, and connector terminal 4 pole indicating RYB Phase Colour and Neutral colour complete fixed to street light pole with suitable size of mild steel clamps, nuts and bolts complete all as specified and as directed. Make : Cat No. GSJB 1414 of Sintex equivalent model as approved.
S&F three run service cable with PVC insulated, stranded copper conductor served with an inner seathing of FRLSH suitable for outdoor uses and PVC sheathed 3 core stranded conductor of 2.5 Sqmm nominal cross sectional area passing through the MS conduit alongwith the pole with MS clamp supports complete all as specified and as directed.
S&F for integral compact wide beam high performance LED flood light luminaire with IP 66 protection, tampered protective toughened glass cover, thermal shock impact resistance cover, epoxy black powder coated finish, high purity , 70W LED of luminous efficiency greater than >120 Lm/watt with built in control gear including connecting up with 2.5 Sqmm multistranded Aluminium/Copper conductor cables of suitable length with fixed to pole/wall, etc and testing complete all as specified and as directed. Make : JETA QUANTO PLUS FLP70WLED757SYMLENS of Havells / Crompton /Jaqua /Phillips /Century.
FREEZCON
M/s GANDHESWAR PHUKAN
AFTAB ENTERPRISES
jitendra narayan goswami
G S Enterprises & Co
M/S BORAH BROTHERS
M/S A K BROTHERS
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .