| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹37.4 LAccepted-AOC VILL JAMALPUR P O NAYA MAHMMADPUR DISTT BHOJPUR ARA PIN 802163 | ARA | BHOJPUR | BIHAR | 802163 | ₹37.4 L Quoted ₹37.7 L | L1 | Accepted-AOC AWARD |
| 2 | L2₹41.2 L+₹3.5 L (9.20%)Rejected-Finance MAGADH COLONY ROAD NO 6 PS MAGADH MEDICAL COLLEGE PO CHANDAUTI MORE DISTT GAYA BIHAR PIN 823001 | GAYA | BIHAR | 823001 | ₹41.2 L+₹3.5 L (9.20%) | L2 | Rejected-Finance OTHER THAN LOWEST |
| 3 | L3₹41.2 L+₹3.5 L (9.26%)Rejected-Finance | ₹41.2 L+₹3.5 L (9.26%) | L3 | Rejected-Finance OTHER THAN LOWEST |
| 4 | L4₹41.6 L+₹3.9 L (10.4%)Rejected-Finance 32 GRAND SQUARE DANAPUR CANTT PATNA PIN 801503 | PATNA | PATNA | BIHAR | 801503 | ₹41.6 L+₹3.9 L (10.4%) | L4 | Rejected-Finance OTHER THAN LOWEST |
| 5 | L5₹43.6 L+₹5.9 L (15.7%)Rejected-Finance | ₹43.6 L+₹5.9 L (15.7%) | L5 | Rejected-Finance OTHER THAN LOWEST |
Tender Value
₹37.6 L
EMD Value
₹75,200
Closing Date
10 Aug 2022, 6:00 pmClosed
GARRISON ENGINEER
GARRISON ENGINEER (MES) DANAPUR CANTT
PROVN OF 3 X GATE WITH GATE PILLAR AT MAIN OFFICE DRONE DWAR AND TRG AREA OFFR MESS AND 02 X GATE PILLARS AT ENTRANCE OF NEW KLP OF RECORDS AT BRC AND SPL REPAIR TO TOILET BATH PORTION INCLUDING PLASTERING DISTEMPERING AND JOINERY REPLACEMENT
2022_MES_539414_1
GE/DNR/T-33 OF 2022-23 8603/E8
Open Tender
Civil Works
Item Rate
180 days
DANAPUR
AS PER TENDER DOCUMENT
8 documents required · 8 mandatory
₹500
GARRISON ENGINEER
₹75,200
Yes
31 Aug 2022
20 Jul 2022
12 Aug 2022
20 Jul 2022
10 Aug 2022
4 Aug 2022
Amount
Boring holes 3m deep in soil for Single under reamed piles and getting out and disposal of soil to a distance of n.exc 50m, dia of pile 300mm complete all as specified and as directed.
Excavation in trenches n.exc 1.5 m wide and n.exc 1.50m in depth for foundation, pier holes etc n exc 10 sqm on plan and getting out in any type of soil complete all as specified and as directed.
M&L reinforced cement concrete (Nominal mix) 1:1.5:3 type A1 using 20 mm graded aggregate in foundation, footing, foundation beams,plinth beams, bases for columns,pedestal, under reamed piles, mass concrete, etc complete all as specified and as directed.
M&L reinforced cement concrete (Nominal mix) 1:1.5:3 type A1 using 20mm graded aggregate as in columns, pillars, posts, struts etc complete all as specified and as directed.
Form work to sides of rough finished surfaces of concrete flat foundations, footings, bases of columns, sides and sofits (if any) of foundations & plinths beams and similar wk flat etc complete all as specified and as directed.
Form wk to rough finished square, rectangular or polygonal concrete surfaces as in sides of columns, pillars, posts, struts,etc complete all as specified and as directed.
M&L for 20 mm thick prepolished granite stone slab, machine cut to size, as in dado/skirting etc, set and jointed in neat cement slurry and pointed in white or coloured cement to match over and including 10 mm thick on backing coat in CM 1:4 complete all as specified and directed by Engr-in-Charge.
M&L Cement concrete 1:2:4, type B-1 (using 20 mm graded stone aggregate) as in levelling course, roof padding, coping, etc complete all as specified and directed by Engr-in-Charge.
Supply and fixing of aluminium composite panel for external wall cladding the panel consisting of 3mm thick thermoplastic core with 2 coats of metallic finish of approved colour. Rate shall include to fix the main frame into masonary wall / RCC concrete surface with necessary items fixed with Anti Corrosive Resistant 50x50x3mm thick MS angle. CI coated Anchor Fasteners, Galvanized bolt nuts and washer screws and aluminium rivets and other hardware's materials and to ensure water and air tightness complete all as specified and directed.
S & F Stainless Steel Letters or figures (Block, Roman, Italic or Indian) exc. 30cm height and 50mm Thick complete all as specified and directed.
Returning filling in including spreading levelling watering and well ramming in layers not exc 25 cm in any type of soil complete all as specified and directed by Engr-in-Charge.
Removing excavated material exc. 50m but n exc 250m and depositing where directed at a level n.exc. 1.5 m above the starting point.
Taking up or down steel tubing and connections, complete all as specified and directed for following sizes :-
20 mm dia of bore
25 mm dia of bore
Re-fixing of old steel GI tubing and connections in new or old position with all pipe fitting such as bends, tees, elbows, reducers, unions, plugs, sockets etc, fixed to walls and in ceiling or laid in floors etc for following bore:- Note :- Old GI pipe obtained from item No. 14.00 shall be re-used after cleaning.
20 mm dia of bore
25 mm dia of bore
S&F GI steel tubes, medium grade galvanised with all pipe fittings such as bends, tees, elbows, reducers, unions, plugs, sockets etc, fixed to walls and in ceiling or laid in floors etc for following bore:-
20 mm dia of bore
25 mm dia of bore
Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing), removing rubbish off the premises complete all as specified and as directed.
M&L 100mm thick PCC 1:2:4 type B-2 using 40mm graded aggregate as in Sub base flooring for receiving kota stone complete all as spd and directed.
M&L Terrazzo tiles 20cm x 20cm x 20mm thick, with size of chips upto 6mm; set, jointed and pointed in neat cement slurry in floors, and cut and polished including Screed bed or bedding layer of Cement Mortar (1:6), 15 mm thick for laying floor finishes, necessary grinding, rubbing, rounding to exposed edges and polishing in granite finish and treating the surface with beeswax polish complete all as specified and directed.
M&L Terrazzo tiles with bullnosed edge 32 cm x 20 cm x 40 mm thick, set, jointed and pointed in neat cement slurry with grey cement and pigments as in treads, and cut polished incl rubbing and polishing complete incl 10mm thick plaster in CM 1:6 complete all as specified and directed.
M & L for Non skid ceramic colour tiles (square / rectangular) joint free of 7 to 8mm thick, area of each tile exceeding 0.11 sqm but not exc. 0.18sqm as in floor etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match the surface over and including 15 mm thick screed bed in CM 1:6 complete all as specified and directed.
M & L for glazed coloured ceramic tiles 450x300 x7 mm thick (Digital pattern) including highlighter as in dado/ skirting and vertical serfaces set & jointed in neat cement slurry and pointed in colored cement 0ver and incl 10 mm thick cement mortar 1:4 to match the Shade, pattern, laying etc of tiles complete all as specified and directed.
M & L Mirror polishing on old Kota stone/ terrazo flooring, etc where ever required to give high gloss finish complete all as specified and directed.
Cutting chases in brick walls, pinning in. making good to facings where required and pointing in cement mortar 1:3 to ends or edges of landings, steps, cills, sunshades, shelves, lintels, etc.; and cutting chases for concealed water tubing or concealed conduit wiring, etc., and making good, cutting not exc 10 cm girth complete all as specified and directed.
S&F in repair vitreous china WHB size 530x445x195 mm white including PVC waste pipe but excluding taps, waste, chain & plug & porcelain stopper but including brackets with two coats of synthetic enamel painting over a coat of red oxide primer etc complete all as specified and directed.
M&L Granite tiles 18-20mm thick machine cut , bedded and jointed with grey cement slurry and pointed with white cement with admixture of pigment to match the shade of granite stone incl grinding and polishing over and incl 15mm thick screed bed CM 1:4 all as specified complete.
S & F in repair water closet white vitreous china ware Orissa pattern of size 580x440mm with integral foot rest ‘P’ or ‘S’ trap front or back inlet incl provision of PCC bedding type B1, 1:2:4 ( 20 mm graded aggregate) and connection pipes ( excluding flushing cistern but including flushing pipe 32 mm dia ) (rate also include for taking off unhygienic of WC). complete all as specified and directed.
S & F in repair PVC valve less, syphonic action type flushing cistern of 10 ltr capacity, low level with inlet, ball valve, float and handle including brackets incl PVC connection with CP brass nuts on both sides complete all as specified and directed.
S & F in repair bib tap 15mm chromium plated fency type long body with crutch butterfly handle, screw down screwed for iron pipe or for brass ferrule etc complete all as specified and directed by the Engineer-in-Charge.
Supply and fixing in repair 15mm dia pillar taps, cast copper alloy, with capstan heads, chromium plated , screwed down high pressure, with or without lettered ‘hot’ or ‘cold’ with long screwed shanks and fly-nuts, screwed for iron pipe complete all as specified and directed.
S&F in repair CP towel rail, 20mm dia, D type,60cm long complete all as approved complete all as specified and directed.
S&F in repair 15 mm bore concealed type stop valves, cast copper alloy, screwed down, high pressure, with capstan head, fancy type, chromium plated, with long shank and cup, screwed both ends for iron pipe or for unions and fixed complete all as specified and directed.
S&F in repair 15mm bore angle cock, cast copper alloy CP, fency type high presure with capstan head handle, screwed both ends for iron pipe of for unions all as specified
S&F in repair of stainless steel soap dish, of standard size and shape complete all as specified and directed.
S & F in repair brass chromium plated shower rose fancy type with swivel joints ,125 mm dia with CP arms 300 mm long including fixing to steel pipe or union complete all as specifiedand directed.
S&F PVC (SWR) 'P' trap for 110 mm dia etc complete all as specifiedand directed..
Taking down PVC/AC pipes (including all fittings), with spigot and socket ends of 100/75 mm dia pipe complete all as specified and directed.
S&F PVC (SWR) pipes 110mm bore single socketed in any length with rubber ring joints laid in floors, trenches complete all as specified and directed.
S&F110 mm dia PVC (SWR) pipes single socketed in any length with rubber ring joints fixed to walls with brackets etc complete all as specified and directed.
S&F PVC (SWR) pipes 75mm bore single socketed in any length with rubber ring joints laid in floors, trenches complete all as specified and directed.
S&F 75 mm dia PVC (SWR) pipes single socketed in any length with rubber ring joints fixed to walls with brackets etc complete all as specified and directed.
S&F PVC (SWR) bend/shoes any radius of 110 mm dia complete all as specified and directed.
S&F PVC (SWR) bends any radius With access door of 110 mm dia complete all as specified and directed.
S&F PVC (SWR) bends any radius With access door of 75 mm dia complete all as specified and directed.
S&F PVC (SWR) bend/shoes any radius of 75 mm dia complete all as specified and directed.
S&F PVC (SWR) vent cowl of 110 mm dia complete all as specified and directed.
Dismantling water tanks of capacity exc 500 and n exc 1000 ltrs complete all as specified and directed.
S&F Rotational moulded polyethylene water storage tanks (cylindrical vertical with closed top) three layered hoisted and fixed in position all as specified in SSR Pt-I of 1000 Ltr capacity including CP tank nipple complete all as specified and directed.
S&F Ball valves 20mm dia high pressure of PTMT with epoxy coated Aluminium rod & high density plastic ball screwed for iron pipe and fixed. (Minimum weight 20mm-210gms) complete all as specified and directed.
S & F in repair 25mm dia gun metal gate valve with iron wheel head, screwed both ends for iron pipe and fixed complete all as specified and as directed.
S & F 75/100 mm bore PVC (SWR) floor trap, plain with grating including jointing to waste pipe, all as specified and directed.
Taking down cement plaster on brick / concrete wall etc incl racking out joints, hacking for key and scrubbing down with water complete all as specified and directed.
M & L for rendering 15 mm thick in cement mortar 1:4, in two layers (1st layer 10 mm thick rendering coat and 2nd layer 5 mm thick finishing coat) on brick work or concrete surfaces, second layer (finishing coat) mixed with liquid water proofing compound @ 200 ml / 50 Kg bag of cement as per manufacturer's instructions and finished the surfaces even and fair without using extra cement complete all as specified and directed. Note:- Liquid WPC will be measured and paid separately.
M & L Rendring 15mm thick in cement mortar 1:6 on fair faces of brick/concrete surfaces finished even and smooth without using extra cement complete all as specified and directed.
M & L rendering 10mm thick in cement mortar 1:3 on fair face of bricks/concrete surfaces in ceiling finishing even and smooth without using extra cement complete all as specified and directed.
Supply only water proofing compound (liquid), ISI marked.
Demolition of brick work built in cement mortar or cement lime mortar including removal to a distance exc 250 m but n.exc 500 m complete all as specified and as directed.
M & L for Brick work with sub class ‘B’ bricks straight or curved on plan exc 6m mean radius built in cement mortar 1:6 complete all as specified and as directed.
M&L Brick work with sub class ‘B’ bricks straight or curved on plan to any radius in half brick thick walls, built in CM 1:4 complete all as specified and directed.
M&L two coat of cement base paint over a coat of primer on wall including preparation of newly plastered surfaces complete all as specified and directed.
M&L for preparation of old decorated plastered/ unplastered surfaces of walls of any description by washing, rubbing down and applying one coat of cement base paint complete as specified and directed.
M&L for preparation of old decorated plastered/ unplastered surfaces of external walls of any description by washing, rubbing down and applying one coat of weather coat paint complete as specified and directed.
Ditto all as per item No 63.00 above but one coat of weather coat paint over a coat of cement primer complete all as specified and as directed.
M & L preparation of newly plastered surface and applying two coats of oil bound distemper over a coat of primer complete all as specified and directed.
M&L for preparation of old plastered/unplastered surfaces of walls by brooming down or steel wire brushing, scrapping down smoke soot, moulds, moss, and efflorescent salts and trading oil and greasy spots and applying two coats of distemper oil emulsion, white or tinned (change of colour as required) complete all as specified and directed.
M & L Preparing new plastered surfaces of ceiling and applying two coats of oil emulsion distemper complete all as specified and directed.
M&L for preparation of old decorated plastered/unplastered surfaces of ceiling surface by brooming down or steel wire brushing, scrapping down smoke soot, moulds, moss, and efflorescent salts and trading oil and greasy spots and applying two coat of oil emulsion distemper complete all as specified and as directed. .
Demolition of cement concrete (unreinforced) in ground floors and paving n exc 15 cm thickness (below or above ground level) including all type of tiling, marble chips , terrazo finish where ever existing etc all as specified and directed
M&L for 75mm thick PCC 1:3:6 type C2 using 40mm graded stone aggregate as in floor/plinth protection laid in suitable panels finished even and fair all as spd . 6mm Joints should be filled with bitumen mastic filling comprising of one part of heated bitumen 85/25 or 80/100 gde and three part of sand ( all by weight) complete all as specified and directed.
Demolition of reinforced cement concrete of any description and in any position not otherwise specifically provided for water tank of old pattern including staging and removing the same exc 1.5 Km from defence land complete all as specified and directed
M&L Providing reinforced cement concrete type A-1 (1:1.5:3) (20 mm graded agg) in Door or window lintel, lintel bends/plinth bend incl necessary formwork complete all as specified and as directed.
M & L for mild steel TMT bars 10 mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9 mm dia or securing with clips complete all as specified and directed.
M & L for mild steel TMT bars 5 mm dia and over upto and including 8 mm dia as in stirrups, spacers and binders, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9 mm dia or securing with clips complete all as specified and directed.
Cutting holes into or through brick or concrete wall, built in cement mortar superficial area n.exc 150 Sqcm complete all as specified and directed.
Taking down chowkat with shutter (without taking off shutters from the frame) n. exc 1.5 Sqm complete all as specified and directed.
Taking down chowkat with shutter (without taking off shutters from the frame) exc 1.5 Sqm but not exc 4.0 Sqm each complete all as specified and directed.
Taking down Shutters of any description exc 1 sq. m and n exc 2 sqm each complete all as specified and as directed.
Solid PVC door frame of size 50mm x47mm made out of 5mm plain clour PVC sheet reinforced with MS square tube, supplying and fixing in opening as per specification and drawing complete all as specified and directed.
S & F 28 to 30 mm(stiles) Factory Made Solid PVC Moulded door shutter with particle board core , with 2, 3 or 6 raised panel design with 2mm thick moulded PVC sheet on the front face & 2mm plain colour PVC sheet on back face, in frame at site as per specification & drawings as given in SSR part - II (2010 print) on serial page No. 161 complete all as specified and directed.
S&F aluminium Butt hinges (ISI marked), medium weight of size 100 mm complete all as specified and directed.
S&F Pressed steel frames (Factory made) made out of 1.25 mm thick black MS sheet for doors, with one or more rebates including necessary fixing lugs(hold fast), Butt hinges, lock strike plate, etc complete, size of frame 125x60mm incl bottom of each chowkat to be welded with 2 nos 25x25x3mm thick flat iron projecting 10 cm on either side and back fill to chowkats with PCC 1:3:6 type C-O using 12.5 mm graded crushed stone aggregate complete all as specified.
S&F alumnium sheet 0.5mm thick for crumplel joint with necessary materials fixed with screws complete all as directed by Engr-in-Charge
S & F factory made 35mm thick 2nd class hardwood plain framed, panelled shutter (two panel) with lock rail and panel of 9mm B.W.P commercial ply or 12mm veneered particle board with commercial veneering on both faces , size of rail and stile as per IS:1003 (Part-I), Klin seasoned and chemically pressure treated all as per SSR complete all as directed.
S & F 2nd class hard wood 35 mm thick glazed and gauzed skelton shutters, open rebated and prepared to receive glass, gauze etc (without sash bars) edges of framing plain, chamfered or rounded, fitted with cut and shutters as specified in SSR Part I, Section 8, clause 8.24 (a) complete all as specified and directed.
S & F steel windows with side hung shutter incl hold fast, box type butt hinges with bow handle,steel peg stay, tower bolts ( each shutter having two tower bolts 100mm long ) complete (with glazing bars) dovetailed or welded complete all as specified and as directed.
~Ditto~ all as per item No 86.00 above but without glazing bars complete as specified and as directed.
S & F Steel ventilator with top hung shutter including, hinges, peg stay, complete all as spesified and directed
S & F Mild steel framed works such as grills,gratings,etc, with ends of bars shouldered and/or riveted, or forged into spikes; framed guard bars; barred iron doors; ladders; framed balusters; walk ways; railings; framework of water tanks and similar work for portions framed and hung as gates, including pintle hinges, stops, hand made sliding bolts, etc conforming to Fe 290 Gde -E-165. complete all as specified and directed.
M & L PCC 1:2:4 type B1 (20mm graded aggregates) as in bed blocks for hold fasts, coping etc including form work wherever necessary complete all as specified and directed.
S & F Galvanised mild steel wire cloth 0.56 mm nominal dia of wire and average width of aperture 1.18 mm and fixed with tinned tacks etc complete all as specified and directed.
Hacking out old boken glass (any thickness, size, quality or description) from wooden frames/steel frames glazed with oil putty or fixed with beads complete all as specified and directed..
S& F 4 mm thick sheet glass ordinary quality and glazing with oil putty in square n. exc 0.5 Sqm in each pane complete all as specified and directed...
S & F 4 mm thick figured glass pin head type and glazing with oil putty in squares n exc 0.5 Sqm in each pane etc complete all as specified and directed...
S & F in repair Galvanised mild steel wire cloth 0.56 mm nominal dia of wire and average width of aperture 1.18 mm and fixed with tinned tacks etc complete all as specified and directed.
S&F Butt hinges (ISI marked), medium weight, cold rolled mild steel of size 100 mm complete all as specified and directed.
S & F 200mm long aluminum anodised barrel tower bolts of extruded section complete all as specified and directed.
S & F Aluminium handles, cast type, anodized 150 mm size complete ISI Marked complete all as specified and directed.
S & F aluminum alloy anodised sliding door bolts with hasp & staple & fixing clips of sheet cast extruded section & fixing bolts & sliding bolts of extruded section 250mm long complete all as specified and directed.
S & F of 150 mm size (Overall length of cover plate) floor door stopper of aluminium body and tongue, anodised, with hard drawn steel spring complete all as specified and directed.
M & L preparing surfaces of new wood and wood based materials of any description and girth, not otherwise described and treated with two coats of synthetic enamel paint over a coat of pink primer complete all as specified and directed.
M&L for preparation of old painted wooden surfaces of any description, not otherwise described, over 10cm width or girth and applying two coat of synthetic enamel paint complete all as specified and as directed
M&L for preparation of new steel / iron surfaces of any description over 10 cm width or girth and applying two coat of synthetic enamel paint over a coat of red-oxide primer complete all as specified & directed.
M&L for preparation of new steel / iron surfaces of any description over 10 cm width or girth and applying two coat of synthetic enamel paint complete all as specified & directed.
M&L for preparation of old painted steel surfaces of any description, not otherwise described, over 10cm width or girth and change of existing colour including removal of sclaed paint and applying two coats of synthetic enamel paint complete all as specified and as directed.
Demolition of concrete of any description and in any position not otherwise specifically provided for complete.
M&L for PCC 1:3:6 type C-2 (Using 40 mm graded stone aggregate) in mass concrete, roof padding/kerbs/sunken slab etc complete all as spd and directed,
M & L average thickness 25mm for plain cement concrete 1:2:4 type B-0 (using 12.5 mm graded stone aggregate), as in padding / levelling course for maintain to proper slope of roof including necessary form work as required complete all as specified and directed.
M&L 15 mm thick screed bed mixed with water proofing compound at 200ml/per beg of cement on roof surfaces/concrete surface in CM 1:4 complete all as specified as directed. Note : WPC shall be measured separately under appropriate item
M&L for water proofing treatment on non approachable / non accessible roof surface horizontal and vertical surfaces in following sequence through manufacturer / authorized applicator of the manufacturer complete all as specified and directed :- (i) Properly cleaning and drying concrete surfaces. (ii) Applying a coat of oxidized bitumen based solvent primer @ 0.3 Kg / sqm. (iii) Applying evenly tack coat of industrial bitumen 85 / 25 grade @ 1.2 Kg / sqm. (iv) Laying unrolled over the bitumen coat surfaces polymeric water proofing membrane, hyperplas standard weight not less than 3 Kg / sqm with 100 mm over laps shall be sealed by flame as per manufacturer instruction. (v) Applying a coat of aluminium paint @ 100 gm / sqm over and including a coat of hot air blown grade bitumen of grade 85 / 25 @ 1.2 Kg / sqm duly sanded over polymeric membrane complete. NOTE:- The polymeric water proofing membrane shall be extended upto parapet walls and inserted in walls by cutting groove and making good with cement mortar 1:3 as directed.
Preparing surface of sunken slab and applying 15 mm thick cement plaster 1:4 cement sand mortar with integral water proofing compound both on floor and wall. The surface shall then be cured and allowed to dry then applying Epoxy Resin coating polymer modified cementitious coating like brush bond of Fosroc, Pidilite and Bostic as per manufacturer's instructions both on floor as well as on wall and sunken floor shall be filled with graded cinder complete all as specified.(IWPC will be paid separately)
Supplying and laying of CPVC pipes 40mm outer dia SDR 11 & Plain CPVC SDR 11 fittings on walls/ceiling or laying in floors complete all as specified
M&L for taking down, chipping and removing the loose, split, damaged cement concrete, cement mortar surfaces of RCC Columns, beams, walls, chajjah etc and exposing the reinforcement, wire brushing and cleaning the exposed steel reinforced bar and wash the re-bar with clean water for removing all rusts from the old re-bar surfaces, applying rust remover over the cleaned re-bar surface , fixing new reinforcement for strengthen the members as required, applying two coats of epoxy zinc primer on new and old steel surfaces, saturate the substrate with water applying one coat of polymer modified bond coat on affected concrete surfaces and finally providing polymer modified cement and sand mortar in CM 1:3 mix (polymer @ 10-15% of cement qty), 20mm thk in two coats, using polymer as per manufacturer's instructions complete all as specified and directed. Make : Fosroc/sicka/STP/pidilite or equivalent as approved by GE (Note :- New reinforcement and MS Sections will be measured and paid separately)
S&F welded steel wire fabric, cut to length, fixed to steel members / reinforcement steel, weight per Sqm exc 2.5 kg but not exc. 4 Kg complete all as specified and as directed.
Taking down carefully copper / aluminium point wiring (light, fan, switch, socket or power, Bell & Two way point) complete with fitting such as switches, sockets, ceiling rose, sketch light fittings etc, and making good the disturbed surface of walls and floors etc complete all as specified and directed.
Taking down carefully main switches DB's/ MCB DB's with MCB and making good the disturbed surfaces of walls complete all as specified and directed.
Taking down carefully copper / aluminium sub main wiring including teak wood batten / conduit and making good the disturbed surface of walls complete all as specified and directed.
M&L Point wiring complete with cable PVC, insulated, unsheathed, 1100 volts grade conforming to IS-694, 1.5 Sq mm (nominal area) FRLS stranded with copper conductor single core drawn through and including non metallic rigid PVC conduit 20mm dia,medium grade and conduit accessories concealed wiring systeb by cutting of wall and making good in walls disturbed surface, with sunken type pressed steel/welded MS terminal boxes not less than 1.6mm thick MS Sheet concealed in wall with hold fasts duly painted with two coat of black bituminious paint over a coat of red oxide, 3 mm thick laminated sheet cover for mounting of fittings like switches, socket outlets, regulators etc., including a run of PVC insulated unsheathed 1.5 Sq mm FRLS copper conductor cable as earth continuity conductor and connecting to common earth dolly complete all as specified and directed for the following: -
One light/ fan point controlled by one, one-way switch, SP, 5 Amps complete all as specified & directed.
One 5 Amps socket out let point controlled by one switch on same board with other switches.
One 5 Amps socket out let point on independent board controlled by one switch.
All as per item no 118.00 above but wiring with 2.5 sq mm single core copper conductor for one socket out let 15/16 amps point on the independent board. Make of cable: Polycab/Havell's/Finolex and Make of PVC conduit: Plaza/Harsh/Kalinga Premium/AKG.
Supply and fixing switch piano flush button single pole one way 5 amps, 240 Volts complete all as specified and directed.
Supply and fixing socket outlet flush type 5 Amps, 5 pin, 240 Volts complete all as specified and directed.
Supply and fixing switch piano flush button single pole one way 15 Amp 240 volt complete all as specified and directed.
Supply and fixing socket outlet flush type multipurpose 2 in 1, 3 pin 5 and 15 Amp, 240 volts complete all as specified and directed.
Supply and fixing Ceiling rose surface bakelite 63.5 mm dia three terminal complete all as specified and directed.
Supply and fixing for batten/angular fittings complete all as specified and directed.
Supply and fix LED Lamp 7/8 watt complete all as specified and directed.
Supply and fix for electronic Fan regulator 450 watt step type complete all as specified and directed.
Supply and fixing double door TPN DBs 4 way of powder coated DB's suitable for MCB's fitted with bus bar,Neutral link,Earth bar and Din ral & DB's will be fitted concealed in wall / surface as per site required complete all as specified and directed.
Supply and fixing double door SPN DBs eight way of powder coated DB's suitable for MCB's fitted with bus bar,Neutral link,Earth bar and Din ral as per existing finishing complete all as specified and directed .
Supply and fixing with MCB SPN 5 to 40 amps 10 KA ,C-series including connection with suitable size aluminium / copper lugs complete all as specified and directed .
Supply and fixing MCB SP 240 volts 5 to 32 Amps, 10 KA breaking capacity, 'C' type including connection with suitable size aluminium / copper lugs complete all as specified and directed .
Supply and fixing MCB TPN 50 to 63 Amps, 10 KA, C-Series including connection with suitable size aluminium / copper lugs complete all as specified and directed.
S&F in LED tube light fitting batten type single tube 1x 18/20 watt 230 volt wall/ ceiling mounted luminaire industrial type made of sheet metal box type suitable for T- 8 tube complete with electronic driver and bipin holder including one No tube 18/20 watt fixed with wall/ceiling incl fittings accessories and connecting with all accessories internally pre wired and incl connecting up with twin core twisted flexible copper conductor cable suitable size all as specified. Make of tube light fitting- Havells Cat No: REGALBATTENT8UPTO1X22WDSBSWH or equivalent model of Bajaj / Wipro/Crompton Greaves Make of Tube:- Havells Cat No. CRYSTAL1213T8DSTL18WLED865SGLASS or equivalent model of Bajaj/Philips/ CG.
S&F in LED tube light fitting single tube 1x 9 watt 230 volt wall mounted luminaire industrial type made of sheet metal box type suitable for T- 8 tube complete with electric electronic driver and bipin holder including one no tube18/20 watt fixed with wall/ceiling incl fittings accessories and connecting with all accessories internally pre wired and incl connecting up with twin core twisted flexible copper conductor cable suitable size all as specified. Make :- Havells Cat No. LUMILINEBS9WLED840SPCWH or equivalent model of Bajaj/Philips/ CG.Jaquar electric/Orient Electric
Supply and fixing metal body air fan / ventilator with louver 230 mm sweep and grouting with nut , bolts & Fastenar on the wall and make good the disturbed surface and electric connection with 1.5 Sqmm three core PVC insulated round flexible copper conductor and sheathed cable upto ceiling rose complete all as specified and directed .Make: HAVELLS Cat No-Ventil Air - DS equivalent make
M&L for Sub main wiring two single core PVC insulated unsheathed cable 1100 volts grade, 6 Sqmm size with multistranded copper conductor, drawn in but excluding non metallic rigid PVC conduit including PVC insulated unsheathed 4 Sqmm cable with multistranded copper conductor green PVC insulated as contineous earth conductor cable connected to earth dolly complete. Note : Two run of 6 sqm copper cable & one rune of 4 sqm copper cable shall be measured & paid as one unit.
M&L sub main wiring with 2 run of 4.00 sqmm (nominal cross-sectional area) PVC insulated (FRLS) unsheathed single core cable of working voltage 1100 volts grade with multi stranded copper conductor including one run of 2.50 sqmm (nominal cross sectional area) PVC insulated (FRLS) unsheathed cable with stranded copper conductor as continuous earth wire connected in common earth dolly drawn in PVC rigid non- metallic conduit complete all as specified and as directed. (NOTE : (i) PVC non rigid nonmetallic conduit shall be measured & paid separately under relevant item of this Schedule ‘A’. (ii) Two run of submain wiring cable alongwith one run of earth wire shall be measured as one length). Make of cable:-Polycab/Havell's/ Finolex
Supply and fixing in repair of Earthing to panel with galvanised steel earth plate electrode 60cm x 60cm x 6mm thick, buried directly in ground (earth pit not less than 2.25m below normal ground level) with top edge of earth plate not less than 1.5m below normal ground level connected to galvanised earth lead wire 4.0mm dia by means of bolts, nut, check nuts and washers of galvanized iron or steel all as shown in electrical plate No.3 of MES Schedule pt-I 2009, GI earth lead wire protected by GI pipe 15 mm dia light grade and connected to earth test point including excavation in any type of soil,returning filling, disposal of soil, providing charcoal dust and common salt upto top edge of earth plate, construction of PCC pit with RCC cover, funnel, watering pipe of 20mm dia GI light grade and provision of earth test point including testing on completion complete.
M/S Sweta Construction
M/S Harsh Traders
M/s KUMAR ENTERPRISES
M/S SHEO KUMAR SINGH AND SONS
RC GUPTA AND SONS
M/s Mukesh and company
M/S ANAND MOHAN ENTERPRISES
MS JODHI PRASAD SINGH SONS
stage.html
html • 0.07 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .