| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹31.0 LAccepted-AOC | L1 | Accepted-AOC Due to lowest bidder | |
| 2 | L2₹34.7 L+₹3.6 L (11.7%)Rejected-Finance | L2 | Rejected-Finance Due to not lowest bidder | |
| 3 | L3₹35.4 L+₹4.3 L (13.9%)Rejected-Finance BEHIND POWER HOUSE WARD NO 6 UDASAR BIKANER RAJASTHAN 334022 | BIKANER | RAJASTHAN | 334022 | L3 | Rejected-Finance Due to not lowest bidder |
| Sl No | Description | Qty | Unit | M/s Chopra Associates L1 | BIDAWAT ENTERPRISES L3 | PUNIYA POWER CONSTRUCTION L2 |
|---|---|---|---|---|---|---|
| 1.00 | Comprehensive & preventive maintenance/overhauling of Pump-Motors (any type) of Various Capacities at KLP Filtration Plant and Raw water Pump House Beechwal in Bikaner Military station area, including daily servicing/Maintenance of all installations comprising with booster/pump houses by qulified Technical/experience rep, check/inspect and maintain all pumps and their connected items, Motors with their connected items, Electric or control panel with all connected items (for all), inspection and maintenance of all type of assets at Filtration Plant & Raw water beechwal primises for smooth & trouble free functioning of Pump-Motor complete all as specified and as directed by Engr-in-charge. (all pumps repair/overhauling/servicing done in pump house premises, only damage part will be sent to workshop if found necessary)
Job Consist with the follwing :-
(i) Regular inspection and servicing of all EM assets/installation comprising with Filtration plant & Raw Water Pump house Beechwal, with Techanically qualified/experience person (manpower is available for 24 hrs for regularly/emergency) and rectify the issues on immediate basis.
(ii) Taking down/dismantling of defective induction/Sumbersible or (any types) motor of any capacity and make from the foundation, disconnecting the electric connection, coupling, pulley, with all connected items for cleaning, servicing, Minor/Major repair and refixing in the same position, making necessary electric connection and testing of induction/sumbersible/(any type) motor after rectification of issue complete all as specified and as directed by Engineer-in-Charge as per site requirment. | 3 | Each Job(quaterly) | 42,000 ₹1,26,000 | 46,000 ₹1,38,000 | 10,000 ₹30,000 Lowest |
| 1.01(iii) Taking down from foundation, base frame by disconnecting suction & delivery lines and coupling, opening including dismantling of centrifugal/Sumbersible/Monoblock or (any types) pump set of any make & any capacity for servicing/cleaning/Major or Minor Repair/replacement of worn out spare parts as per site requirment and re-assembling, installation in same location including testing after complete rectification all as specified and directed by Engr-in-Charge. (iv) M&L for finding and Repair/rectification of all type of complaints against Pumps/motors/NRV/Sluice Valve/Starter/water supply pipe lines (Sunction/Delivery lines inside primises) like Motor not working/pump not working/leakage/blockage/no water supply/no suction of pump etc,(any type) against day to day maintainence/services complaints. Contractor shall be responsible for complete check and found exact issue, Complaint shall be rectified by the contractor within 12 hrs from the launch of complaint time through complaint slip/ teliphonically/messaging. If contractor fail to rectified the above said complaint in given time period then a penalty @ Rs 200/hr will be recovered agaist the each job. Complete site cannot be handed over to contractor, site of defective pump/motors & leakage/blockage/no water supply as per complaint received by operator is only handed over to the contractor on site requirment basis. M&L for cleaning & Checking for make proper serviceable of suction & delivery water supply pipe line, foot valve,sluice valve, NRV, | ||||||
| 1.02instruements, starters, connected control cabling/wiring including electrical panels with switchgears complete as per direction of Engr-in-charge. (v) M&L for opening the gland cap from both side of centrifugal pumps (any type) and taking out the rusted gland dori completely and refilling the new gland dori with grease both side of pump and refixing the gland cap in same position as per requirment on site. (vi) M&L for opening the gland cap from both side of centrifugal/Any type pump and taking out the old/rusted gland dori completely and refilling the new gland dori with grease both side of pump and refixing the gland cap in same position as per requirment on site (as complaint/requirment seen on ground) all as directed by Engr-in-Charge. (vii) Contractor shall provide Techanically qualified/experience person for fault attending within 8 hrs. If the Supply/Filtration plant/Pump-Motor is off load/break down more than 8 hrs, a penalty at the rate of Rs. 5000/- per day shall be levied and deducted from the contractor's payment. The contractor shall be provide/arrange alternate option for defective pump/motor of any capacity or make as per site for avoiding supply failure in case repair/replacement of defective parts takes longer time in genuine condition (condition is fixed by Engr-in-Charge), the expense is deemed in quoted rate and no extra amount paid on this account. | ||||||
| 1.03(viii) During entire contract period any defective components or any other materials which is not specified in Sch 'A' but required repair/replacement to make plant/ machinery fully functional such as Shaft seal/Keys/seals/sleeves/studs or as per site requirment the cost of same shall be deemed included in quoted rates and nothing extra shall be paid to the contractor on this account. (ix) M&L for checking/dismantling/repair//Replacement of U/S leather washers heavy duty with new leather washer heavy duty (ISI marked) suitable for foot valve of existing size dia bore at all booster/pump houses. Complaint for same given in complaint slip/telephonically, during Four month quarter repair of foot valve & NRV will be done as per complaint received. Complaint should be rectify within 8 Hours after launch of complaint, if contractor fail to done that recovery of Rs. 200/- per hours shall be levied and deducted from the contractor's payment. (x) M&L for dismantling of NRV (any size & Make) carefully after disconnecting from suction/delivery line of pumping set unscrewing the both side taking out seat with level and labour and material from replacement of leather washer cleaning inside seat space reassembling, reinstalling back complete as per site requirment. (xi) M&L for applied super quality Grease for Bearing through gun machine in two times in a month complete all as specified and directed by Engr-in-Charge. (xii) Checking of motors with complet Electric connection and rectifying with requird assesories (minor) including | ||||||
| 1.04making connections/ Disconnection for making serviciable or for routine check as per direction of Engineer-in-charge. (xiii) Shifting of pump-Motor set or pump & motor separately in emergency requirment complete with required fittings as per site complete and rate is include in quoted rate all as specified and directed by engineer-in-charge. (xiv) Repair/metal coating/lath work for shaft/impeller/housing case of bearing, body welding/(gas welding) of pump-motor/replacement of petty/minor items for upgradation/repair other than specified in Sch ‘A’ such as shaft seal/ keys/seals/sleeves/fans/studs and other minor repairs as ordered by Engr-in-Charge, transportation to workshop & back to site and make serviceable compete shall be deemed to be included under this job. Note : (i) All complaints for repair/replacement/servicing/cleaning/shifting shall given by department (JE E/M or MCM) on daily basis for this complete job (Ser item No. 1), contractor shall rectify all complaints within 12 hrs after launch of complaint and return the complaint slip with operator sign (for confirmation of rectification) to complaint cell on daily basis. Daily collection of complaint slip, transportation and other necessary equipments shall be arranged/brought by the contractor, hence the bidder is advised to visit the site and assess the quantum of the work to be carried out in the contract and quote their rate accordingly. | ||||||
| 1.05(ii) All above points mentioned in job for the period of four months shall be considered as one Job, Each Job shall be measured and paid in four calendar months. (iii) Dismanling and refiixing of pump & motor job, Gland filling in Pump & Sluice Valve Job is not fixed in numbers, this Job will be done as per site requirment hence contractor dose not denay for the same, and do not claim extra on this account. Refixing is done after rectifying the issue/complaint hence it coverd labour charges for fixing/replacing required spare parts/items and all connected expense, major Spare parts for Repair of pumps and motor shall be measured and paid separately.(iv) Complaints given for regular problems/issue facing by operator and all type of complaints against any type of pumps and motors includind water supply/priming pipe lines shall be rectified by the contractor within 8 hrs from the launch of complaint time through complaint slip/ telephonically/messaging. If contractor fail to rectified the above said complaint in given time period then a penalty @ Rs 200/hrs will be recovered for contractor payment. Complete site cannot be handed over to contractor, site of leakage/pump & Motor not working/foot valve not working/NRV not working/blockage/shifting as per complaint received by operator is only handed over to the contractor on site requirment basis. (v) Contractor should collect complaint slip on daily basis from 09:30 to 10:30 hrs without fail and deposite the same after rectification within time period of 12 hrs, if contractor | ||||||
| 1.06fail to deposite complaint slip with operatort sign with date, then consider as delay in rectification period, which leads to recovery. (vi) Checking of NRV/Foot valve including taking up, cleaning inside and refixing after testing for nonfunctioning complaint is include in this job and no extra cost shall paid to contractor. Repair of foot valve/NRV/ is paid seperatly if any part found unserviceable or required lath work for make functional. (vii) All T&P and vehicles for transpotation will be provide by contractor and no extra payment made out on this account. (viiii) Contractor Shall provide required manpower with all required tools/equipments for attending emergency complaint for 24 hours no extra payment made out on this account. (ix) Quoted rate deemed to be inclusive of all labour, equipment and T&P material/arrangment to attend the day to day maintenance complaint on daily basis . (x) Contractor shall update daily executed work on daily basis with sign of user/operator on complaint slip (maintaining work done register) to concern JE E/M/MCM for updating exact progress of contract agreement. | ||||||
| 2.00Taking down of defective induction motor of the following capacity and make from the foundation, disconnecting the electric connecting coupling pulley, and transporting to work shop cutting down and removing existing burnt out copper windings, cleaning of slots and rewinding with solid copper conductor ( winding wire) complete including varnishing, drying, ovening, overhauling, greasing and fixing in the same position, making necessary electric connection and testing of induction motor complete all as specified and as directed by Engineer-in-Charge. Note : (i) Rate quoted by contractor shall be deemed to be included taking out carefully the burnt/defective motor from the installation to place of winding , removing existing burnt copper wire and rewinding with new wire, fixing the motor in its original place of installation after repair testing etc complete all as specified . Contractor shall report attend and remove the motor with in 48 hrs of repairing & shall reinstall the motor after repair in its original location within 48 hrs from taking out motor from installation failing which panel recovery @ 1500/- per motor per day shall be made from the contractor payment. (ii) Cost of minor repairs /replacement such as fan guard, terminal plate, terminal box, fan etc as directed by Engineer-in-Charge are also included in unit rate of this item. (iii) Make of winding wire shall be Chetak/Devidayal and winding wire shall be conforming to IS and size/gauge of wire shall be as per existing winding wire. (iv) Cost of insulating material viz varnish, packing paper, cotton tape etc are deemed to be included in the rate quoted by contractor for this item. (v) Rate quoted by contractor shall be deemed to include opening of existing electric motor complete and taking out burnt coils from the slots of stator, cleaning of stator slots and rewinding with the same gauge of solid copper conductor ( winding wire) as the previous burnt winding , insulating paper, wooden strips in slots and varnishing the coils, binding with strong threads and reassembling the motor after rewinding. (vi) Contractor shall be taken proper gate pass for repair of motor/pump in out side, civil workshop and maintain record resigter after repair and refixing in existing place of motor/pumping set also inform to concern authority with date. (vii) All motors are issue to contractor undergate pass by AGE E/M office. | ||||||
| 2.01(iv) Cost of insulating material viz varnish, packing paper, cotton tape etc are deemed to be included in the rate quoted by contractor for this item. (v) Rate quoted by contractor shall be deemed to include opening of existing electric motor complete and taking out burnt coils from the slots of stator, cleaning of stator slots and rewinding with the same gauge of solid copper conductor ( winding wire) as the previous burnt winding , insulating paper, wooden strips in slots and varnishing the coils, binding with strong threads and reassembling the motor after rewinding. (vi) Contractor shall be taken proper gate pass for repair of motor/pump in out side, civil workshop and maintain record resigter after repair and refixing in existing place of motor/pumping set also inform to concern authority with date. (vii) All motors are issue to contractor undergate pass by AGE E/M office. (viii) Old Unsv/Replace item retrieved From item No. 01 to 44 Shall be deposited to AGE E/M Store Yard and cost of transportation and T&P shall dem to be included in above quoted rate. | ||||||
| 2.02 | (a) 150 HP capacity, 03 phase 415 volt 50 HZ | 1 | Each Job | 3,000 ₹3,000 Lowest | 4,000 ₹4,000 | 18,500 ₹18,500 |
Tender Value
₹40 L
EMD Value
₹80,000
Closing Date
17 Jul 2025, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE (N) BIKANER
GE (N) BIKANER (Raj)
COMPREHENSIVE MAINT FOR FILTERATION PLANT AND RAW WATER RESERVOIR UNDER GE NORTH AT MIL STN BIKANER
2025_MES_715575_1
GE (N) BKN-TOKEN/01/2025-26
Open Tender
Miscellaneous Works
Item Rate
335 days
GE (N) BIKANER
Please refer Tender documents.
6 documents required · 6 mandatory
₹500
GE (N) BIKANER
₹80,000
Yes
18 Sept 2025
19 Jun 2025
24 Jul 2025
19 Jun 2025
17 Jul 2025
4 Jul 2025
Amount
Comprehensive & preventive maintenance/overhauling of Pump-Motors (any type) of Various Capacities at KLP Filtration Plant and Raw water Pump House Beechwal in Bikaner Military station area, including daily servicing/Maintenance of all installations comprising with booster/pump houses by qulified Technical/experience rep, check/inspect and maintain all pumps and their connected items, Motors with their connected items, Electric or control panel with all connected items (for all), inspection and maintenance of all type of assets at Filtration Plant & Raw water beechwal primises for smooth & trouble free functioning of Pump-Motor complete all as specified and as directed by Engr-in-charge. (all pumps repair/overhauling/servicing done in pump house premises, only damage part will be sent to workshop if found necessary) Job Consist with the follwing :- (i) Regular inspection and servicing of all EM assets/installation comprising with Filtration plant & Raw Water Pump house Beechwal, with Techanically qualified/experience person (manpower is available for 24 hrs for regularly/emergency) and rectify the issues on immediate basis. (ii) Taking down/dismantling of defective induction/Sumbersible or (any types) motor of any capacity and make from the foundation, disconnecting the electric connection, coupling, pulley, with all connected items for cleaning, servicing, Minor/Major repair and refixing in the same position, making necessary electric connection and testing of induction/sumbersible/(any type) motor after rectification of issue complete all as specified and as directed by Engineer-in-Charge as per site requirment.
(iii) Taking down from foundation, base frame by disconnecting suction & delivery lines and coupling, opening including dismantling of centrifugal/Sumbersible/Monoblock or (any types) pump set of any make & any capacity for servicing/cleaning/Major or Minor Repair/replacement of worn out spare parts as per site requirment and re-assembling, installation in same location including testing after complete rectification all as specified and directed by Engr-in-Charge. (iv) M&L for finding and Repair/rectification of all type of complaints against Pumps/motors/NRV/Sluice Valve/Starter/water supply pipe lines (Sunction/Delivery lines inside primises) like Motor not working/pump not working/leakage/blockage/no water supply/no suction of pump etc,(any type) against day to day maintainence/services complaints. Contractor shall be responsible for complete check and found exact issue, Complaint shall be rectified by the contractor within 12 hrs from the launch of complaint time through complaint slip/ teliphonically/messaging. If contractor fail to rectified the above said complaint in given time period then a penalty @ Rs 200/hr will be recovered agaist the each job. Complete site cannot be handed over to contractor, site of defective pump/motors & leakage/blockage/no water supply as per complaint received by operator is only handed over to the contractor on site requirment basis. M&L for cleaning & Checking for make proper serviceable of suction & delivery water supply pipe line, foot valve,sluice valve, NRV,
instruements, starters, connected control cabling/wiring including electrical panels with switchgears complete as per direction of Engr-in-charge. (v) M&L for opening the gland cap from both side of centrifugal pumps (any type) and taking out the rusted gland dori completely and refilling the new gland dori with grease both side of pump and refixing the gland cap in same position as per requirment on site. (vi) M&L for opening the gland cap from both side of centrifugal/Any type pump and taking out the old/rusted gland dori completely and refilling the new gland dori with grease both side of pump and refixing the gland cap in same position as per requirment on site (as complaint/requirment seen on ground) all as directed by Engr-in-Charge. (vii) Contractor shall provide Techanically qualified/experience person for fault attending within 8 hrs. If the Supply/Filtration plant/Pump-Motor is off load/break down more than 8 hrs, a penalty at the rate of Rs. 5000/- per day shall be levied and deducted from the contractor's payment. The contractor shall be provide/arrange alternate option for defective pump/motor of any capacity or make as per site for avoiding supply failure in case repair/replacement of defective parts takes longer time in genuine condition (condition is fixed by Engr-in-Charge), the expense is deemed in quoted rate and no extra amount paid on this account.
(viii) During entire contract period any defective components or any other materials which is not specified in Sch 'A' but required repair/replacement to make plant/ machinery fully functional such as Shaft seal/Keys/seals/sleeves/studs or as per site requirment the cost of same shall be deemed included in quoted rates and nothing extra shall be paid to the contractor on this account. (ix) M&L for checking/dismantling/repair//Replacement of U/S leather washers heavy duty with new leather washer heavy duty (ISI marked) suitable for foot valve of existing size dia bore at all booster/pump houses. Complaint for same given in complaint slip/telephonically, during Four month quarter repair of foot valve & NRV will be done as per complaint received. Complaint should be rectify within 8 Hours after launch of complaint, if contractor fail to done that recovery of Rs. 200/- per hours shall be levied and deducted from the contractor's payment. (x) M&L for dismantling of NRV (any size & Make) carefully after disconnecting from suction/delivery line of pumping set unscrewing the both side taking out seat with level and labour and material from replacement of leather washer cleaning inside seat space reassembling, reinstalling back complete as per site requirment. (xi) M&L for applied super quality Grease for Bearing through gun machine in two times in a month complete all as specified and directed by Engr-in-Charge. (xii) Checking of motors with complet Electric connection and rectifying with requird assesories (minor) including
making connections/ Disconnection for making serviciable or for routine check as per direction of Engineer-in-charge. (xiii) Shifting of pump-Motor set or pump & motor separately in emergency requirment complete with required fittings as per site complete and rate is include in quoted rate all as specified and directed by engineer-in-charge. (xiv) Repair/metal coating/lath work for shaft/impeller/housing case of bearing, body welding/(gas welding) of pump-motor/replacement of petty/minor items for upgradation/repair other than specified in Sch ‘A’ such as shaft seal/ keys/seals/sleeves/fans/studs and other minor repairs as ordered by Engr-in-Charge, transportation to workshop & back to site and make serviceable compete shall be deemed to be included under this job. Note : (i) All complaints for repair/replacement/servicing/cleaning/shifting shall given by department (JE E/M or MCM) on daily basis for this complete job (Ser item No. 1), contractor shall rectify all complaints within 12 hrs after launch of complaint and return the complaint slip with operator sign (for confirmation of rectification) to complaint cell on daily basis. Daily collection of complaint slip, transportation and other necessary equipments shall be arranged/brought by the contractor, hence the bidder is advised to visit the site and assess the quantum of the work to be carried out in the contract and quote their rate accordingly.
(ii) All above points mentioned in job for the period of four months shall be considered as one Job, Each Job shall be measured and paid in four calendar months. (iii) Dismanling and refiixing of pump & motor job, Gland filling in Pump & Sluice Valve Job is not fixed in numbers, this Job will be done as per site requirment hence contractor dose not denay for the same, and do not claim extra on this account. Refixing is done after rectifying the issue/complaint hence it coverd labour charges for fixing/replacing required spare parts/items and all connected expense, major Spare parts for Repair of pumps and motor shall be measured and paid separately.(iv) Complaints given for regular problems/issue facing by operator and all type of complaints against any type of pumps and motors includind water supply/priming pipe lines shall be rectified by the contractor within 8 hrs from the launch of complaint time through complaint slip/ telephonically/messaging. If contractor fail to rectified the above said complaint in given time period then a penalty @ Rs 200/hrs will be recovered for contractor payment. Complete site cannot be handed over to contractor, site of leakage/pump & Motor not working/foot valve not working/NRV not working/blockage/shifting as per complaint received by operator is only handed over to the contractor on site requirment basis. (v) Contractor should collect complaint slip on daily basis from 09:30 to 10:30 hrs without fail and deposite the same after rectification within time period of 12 hrs, if contractor
fail to deposite complaint slip with operatort sign with date, then consider as delay in rectification period, which leads to recovery. (vi) Checking of NRV/Foot valve including taking up, cleaning inside and refixing after testing for nonfunctioning complaint is include in this job and no extra cost shall paid to contractor. Repair of foot valve/NRV/ is paid seperatly if any part found unserviceable or required lath work for make functional. (vii) All T&P and vehicles for transpotation will be provide by contractor and no extra payment made out on this account. (viiii) Contractor Shall provide required manpower with all required tools/equipments for attending emergency complaint for 24 hours no extra payment made out on this account. (ix) Quoted rate deemed to be inclusive of all labour, equipment and T&P material/arrangment to attend the day to day maintenance complaint on daily basis . (x) Contractor shall update daily executed work on daily basis with sign of user/operator on complaint slip (maintaining work done register) to concern JE E/M/MCM for updating exact progress of contract agreement.
Taking down of defective induction motor of the following capacity and make from the foundation, disconnecting the electric connecting coupling pulley, and transporting to work shop cutting down and removing existing burnt out copper windings, cleaning of slots and rewinding with solid copper conductor ( winding wire) complete including varnishing, drying, ovening, overhauling, greasing and fixing in the same position, making necessary electric connection and testing of induction motor complete all as specified and as directed by Engineer-in-Charge. Note : (i) Rate quoted by contractor shall be deemed to be included taking out carefully the burnt/defective motor from the installation to place of winding , removing existing burnt copper wire and rewinding with new wire, fixing the motor in its original place of installation after repair testing etc complete all as specified . Contractor shall report attend and remove the motor with in 48 hrs of repairing & shall reinstall the motor after repair in its original location within 48 hrs from taking out motor from installation failing which panel recovery @ 1500/- per motor per day shall be made from the contractor payment. (ii) Cost of minor repairs /replacement such as fan guard, terminal plate, terminal box, fan etc as directed by Engineer-in-Charge are also included in unit rate of this item. (iii) Make of winding wire shall be Chetak/Devidayal and winding wire shall be conforming to IS and size/gauge of wire shall be as per existing winding wire. (iv) Cost of insulating material viz varnish, packing paper, cotton tape etc are deemed to be included in the rate quoted by contractor for this item. (v) Rate quoted by contractor shall be deemed to include opening of existing electric motor complete and taking out burnt coils from the slots of stator, cleaning of stator slots and rewinding with the same gauge of solid copper conductor ( winding wire) as the previous burnt winding , insulating paper, wooden strips in slots and varnishing the coils, binding with strong threads and reassembling the motor after rewinding. (vi) Contractor shall be taken proper gate pass for repair of motor/pump in out side, civil workshop and maintain record resigter after repair and refixing in existing place of motor/pumping set also inform to concern authority with date. (vii) All motors are issue to contractor undergate pass by AGE E/M office.
(iv) Cost of insulating material viz varnish, packing paper, cotton tape etc are deemed to be included in the rate quoted by contractor for this item. (v) Rate quoted by contractor shall be deemed to include opening of existing electric motor complete and taking out burnt coils from the slots of stator, cleaning of stator slots and rewinding with the same gauge of solid copper conductor ( winding wire) as the previous burnt winding , insulating paper, wooden strips in slots and varnishing the coils, binding with strong threads and reassembling the motor after rewinding. (vi) Contractor shall be taken proper gate pass for repair of motor/pump in out side, civil workshop and maintain record resigter after repair and refixing in existing place of motor/pumping set also inform to concern authority with date. (vii) All motors are issue to contractor undergate pass by AGE E/M office. (viii) Old Unsv/Replace item retrieved From item No. 01 to 44 Shall be deposited to AGE E/M Store Yard and cost of transportation and T&P shall dem to be included in above quoted rate.
(a) 150 HP capacity, 03 phase 415 volt 50 HZ
(b) 125 HP capacity, 03 phase 415 volt 50 HZ
(c) 60 to 75 HP capacity, 03 phase 415 volt 50 HZ
(d) 40 to 50 HP capacity, 03 phase 415 volt 50 HZ
(e) 20 to 30 HP capacity, 03 phase 415 volt 50 HZ
(f) 7.5 to 15 HP capacity, 03 phase 415 volt 50 HZ
(g) 3 to 5 HP capacity, 03 phase 415 volt 50 HZ
(h) 0.5 to 3 HP capacity, single phase 415 volt 50 HZ
Material only the following spare parts for centrifugal pump of 150 HP capacity (any make & Model as per site) required to be replaced under item No 1 above as specified and directed by Engr-in-charge.
(a) Inter stage/shoulder ring
(b) Gland Cap CI with nut/eye bolt complete
(c) Gland/pump sleev bush/bushing SS type
(d) Wear/Split lantern ring CI
(e) Shaft Sleeve Bronze
(f) Shaft Sleeve Nut (Bronze)
(g) SS pump shaft as per existing
(h) Brass/Bronze impellar comlete with impellar key
(i) Gasket set manifold
(j) Air release cock brass type as per site
(k) Cooling pipe for Gland (2 Nos)
Material only the following spare parts for centrifugal pump of 125 HP capacity (any make & Model as per site) required to be replaced under item No 1 above as specified and directed by Engr-in-charge. Note : Old Unsv/Replace items deposited to AGE E/M Store Yard including transportation and labour by contractor no extra payment made on this account.
(a) Inter stage ring
(b) Gland Cap CI with nut bolt complete
(c) Gland/pump sleev bush/bushing SS type
(d) Wear/Split lantern ring CI
(e) Shaft Sleeve Bronze
(f) Shaft Sleeve Nut (Bronze)
(g) SS pump shaft as per existing
(h) Brass/Bronze impellar comlete with impellar key
(i) Gasket set manifold
(j) Air release cock brass type as per site
(k) Cooling pipe for Gland (2 Nos)
Material only the following spare parts for centrifugal pump of 60 to 75 HP capacity (any make & Model as per site) required to be replaced under item No 1 above as specified and directed by Engr-in-charge. Note : Old Unsv/Replace items deposited to AGE E/M Store Yard including transportation and labour by contractor no extra payment made on this account.
(a) Inter stage ring
(b) Gland Cap CI with nut bolt complete
(c) Gland/pump sleev bush/bushing SS type
(d) Wear/Split lantern ring CI
(e) Shaft Sleeve Bronze
(f) Shaft Sleeve Nut (Bronze)
(g) SS pump shaft as per existing
(h) Brass/Bronze impellar comlete with impellar key
(i) Gasket set manifold
(j) Air release cock brass type as per site
(k) Cooling pipe for Gland (2 Nos)
Material only the following spare parts for centrifugal pump of 40/50 HP capacity (any make & Model as per site) required to be replaced under item No 1 above as specified and directed by Engr-in-charge. Note : Old Unsv/Replace items deposited to AGE E/M Store Yard including transportation and labour by contractor no extra payment made on this account.
(a) Inter stage ring
(b) Gland Cap CI with nut bolt complete
(c) Gland/pump sleev bush/bushing SS type
(d) Wear ring CI
(e) Shaft Sleeve Bronze
(f) Shaft Sleeve Nut (Bronze)
(g) SS pump shaft as per existing
(h) GM impellar comlete with impellar key
(i) Gasket set manifold
(j) Air release cock brass type as per site
(k) Cooling pipe for Gland (2 Nos)
Material only the following spare parts for centrifugal pump of 25/30 HP capacity (any make & Model as per site) required to be replaced under item No 1 above as specified and directed by Engr-in-charge. Note : Old Unsv/Replace items deposited to AGE E/M Store Yard including transportation and labour by contractor no extra payment made on this account.
(a) Inter stage ring
(b) Gland Cap CI with nut bolt complete
(c) Gland/pump sleev bush/bushing SS type
(d) Wear ring CI
(e) Shaft Sleeve Bronze
(f) Shaft Sleeve Nut (Bronze)
(g) SS pump shaft as per existing
(h) GM impellar comlete with impellar key
(i) Gasket set manifold
(j) Air release cock brass type as per site
(k) Cooling pipe for Gland (2 Nos)
Material only the following spare parts for centrifugal pump/Monoblock pump of 10 to 20 HP capacity (any make & Model as per site) required to be replaced under item No 1 above as specified and directed by Engr-in-charge. Note : Old Unsv/Replace items deposited to AGE E/M Store Yard including transportation and labour by contractor no extra payment made on this account.
(a) Inter stage ring
(b) Gland Cap CI with nut bolt complete
(c) Gland/pump sleev bush/bushing SS type
(d) Wear ring CI
(e) Shaft Sleeve Bronze
(f) Shaft Sleeve Nut (Bronze)
(g) SS pump shaft as per existing
(h) GM impellar comlete with impellar key
(i) Gasket set manifold
(j) Air release cock brass type as per site
(k) Cooling pipe for Gland (2 Nos)
Material only the following spare parts for centrifugal pump/Monoblock pump of 3 to 10 HP capacity (any make & Model as per site) required to be replaced under item No 1 above as specified and directed by Engr-in-charge. Note : Old Unsv/Replace items deposited to AGE E/M Store Yard including transportation and labour by contractor no extra payment made on this account.
(a) Inter stage ring
(b) Gland Cap CI with nut bolt complete
(c) Gland/pump sleev bush/bushing SS type
(d) Wear ring CI
(e) Shaft Sleeve Bronze
(f) Shaft Sleeve Nut (Bronze)
(g) SS pump shaft as per existing
(h) GM impellar comlete with impellar key
(i) Gasket set manifold
(j) Air release cock brass type as per site
(k) Cooling pipe for Gland (2 Nos)
Material for replacement of old/Unsv Ball bearing of required size as per site suitable for pumps & motors of following capacity complete under item No 1 above as specified and directed by Engr-in-charge.
(a) 0.5 HP to 7.5 HP
(b) 10 HP to 30 HP
(c) 40 HP to 75 HP
(d) 125 HP to 150 HP
Material for repair/replacement of Rigid type coupling suitable for 75 to 150 HP motor-pumping set complete under item No 1 above as specified and directed by Engr-in-charge.
(a) 7.5 to 10 HP
(b) 15 to 60 HP
(b) 75 to 150 HP
Material for replacement of Flexible tyre/star type coupling suitable for 40 to 75 HP motor-pumping set complete under item No 1 above as specified and directed by Engr-in-charge.
(a) 7.5 to 10 HP
(b) 15 to 60 HP
(b) 75 to 150 HP
Material and Labour for repair to unserviceable sluice valve of following size bore by dismantling and opening the gland cap and head of sluice valve (any make & Model as per site) required to be replaced under item No 1 above or any Location in entire station as specified and directed by Engr-in-charge, including taking out the unserviceable lock or check nut/gasket/Gland flange/gland bush/screw/O-ring/Wedge/body Ring/wedge nut/thurst bridge/spindle and taking to workshop for reapir the same as per site requirment including fitting the material, grinding the material cutting the threads as per requirment by lathe machine and fabrication of new lock nut or any unseviceable parts required at site for make serviceable (if Lock check Nut, Spindle & Gland bush cannot repaired then same will be replace with new and rate is inclusive in this account) complete and refixing in the same position with gland filling, testing the sluice valve, complete, all as specified and directed by Engr-in-Charge. Note : all parts of sluice valve is considerd for repair in this Job)
(a) 80 dia mm bore.
(b) 100 dia mm bore.
(c) 150 dia mm bore.
(d) 200 dia mm bore.
(e) 250 dia mm bore.
(f) 300 dia mm bore.
(g) 350 dia mm bore.
(h) 400 dia mm bore.
(i) 450 dia mm bore.
(j) 500 dia mm bore.
(k) 600 dia mm bore.
M&L for suction/delivery/Priming GI pipe line of following size dia bore ISI marked medium grade in short length both side flanged type or as per site requirment with gasket joint nut bolts washers complete with all fittings as per site requirment for any type, for jointing different type of pipes fittings also, laid in trenches or fixed to walls, ceilings or in floors complete fittings all as specified & directed by the Engineer-in-Charge. Make:- Jindal/Swastik/Tata Note- (i) Rates quoted by tenderer incl taking up or down of lines for repair, cleaning of serviceable pipe internally/externally for re-use and refixing after repairing complete including cutting/screwing existing pipe/grinding/welding work as reuqired complete. (ii) Rates quoted by tenderer incl excavation, returning & filling, removing soil and making good disturbed surface on both side, Dewatering from trenches and taking out of mude etc with the help of JCB or mud pump as required at site and taking out of broken/cracked pipe including welding work as reuqired complete. (iii) Rates quoted by tenderer incl labour cost for finding/tracing the exact issue regarding complaint and complete rectification. (iv) Complete site cannot be handed over to contractor, site of leakage/blockage/no water supply as per complaint received by user is only handed over the contractor on site requirment basis.
(a) size 150 mm bore.
(b) size 100 mm bore.
(c) Size 80 mm bore.
M&L in replacement of metallic antivibration pads with rubber cushion for upto 150 HP motor pumping set including drilling hole at necessary places on foundation base frame .
Dismantling and taking down pump set from base foundation frame by disconnecting electrically and from coupling side taking out at side and demolition the old fondation and making foundation with PCC(1:2:4) type By using 20mm graded stone aggregate including grouting of base hole fast 08 Nos and metalic anti vibration pads with rubber cusion including watering leveling at same size after making of foundation installing of Pump motor and fixing same suction and delivery all as directed by Engr - in- Charge , suitable for following capacity in HP. Note : 1. Any connected item is covered in quoted rate. 2.Rate for cleaning of site is covered in quoted rate.
(a) 125 to 150 HP
(b) 50 to 75 HP
(c) 15 to 40 HP
Taking down broken/rusted iron base frame and Supply and fixing new iron base frame for centrifugal pump set of Following capacity in HP as per existing size with two coats of black paint over a coat of red oxide zinc chromate primer complete all as specified by Engr-in-charge. Note : 1. Any connected item is covered in quoted rate. 2.Rate for cleaning of site is covered in quoted rate.
(a) upto 40 HP
(b) 50 to 75 HP
(c) 125 to 150 HP
M&L for cleaning of KLP filtration plant and RAW water beechwal area in surrounding area (entire in fencing) including trimming, grass cutting etc three times in a contract period complete all as specified and as directed by Engineer-in-Charge.
M&L, T&P and labour for laying, fixing/jointing & testing for steel tubing galvanised medium grade with all fittings as per site requirment for any type, for jointing different type of pipes fittings also with pump and PVC water storage tank (tank inlet and outlet fitting include), for priming of pumps or in any required site as per direction of Engr-in-charge, laid in trenches or fixed to walls, ceilings or in floors complete for following sizes bore dia all as specified and directed by Engr-in-charge.
(a) 15 mm bore dia
(b) 20mm bore dia
(c) 25mm bore dia
(d) 40 mm bore dia
(e) 50mm bore dia
M&L for fixing rotational moulded polythylene water storage tank 3 layer ISI Marked with lid cylindrical vertical with closed top hoisted mounted on staging /roof of OTM//Md Accn/pump house or as per directed by Engr-in-charge with proper foundation of following capacity in ltr, including dismantling and taking out old unserviceable service over head tanks with necessary fittings and depositing in store yard of the Sub Division all as specified and directed by Engr-in-charge. Make-Sintex/Polycon/Prayag
1000 Ltr capacity
750 Ltr capacity
M&L for fixing of Gun metal gate valve (ISI marked) with iron wheel head, screwed both ends for iron pipe of following size including dismantling & taking out old unserviceable gate valve including complete, all as specified & directed. Note : 1. Material required for jointing including cutting/screwing existing pipe/grinding/welding work/Earth work as reuqired include in quoted rate 2. All T&P and vehicles for transpotation will be provide by contractor and no extra payment made out on this account.
(a) 15 mm bore.
(b) 20 dia mm bore
(c) 25 dia mm bore.
(d) 40 dia mm bore.
(e) 50 dia mm bore.
M&L for fixing cast iron body sluice valve heavy duty class ‘PN-1.6’ of following mm bore, ISI marked with IS 14846, both flanged ends and drilled, high tensile stainless steel spindle, CI gate with brass ring, non rising type, cast iron wheel handle, cast iron cap, complete with 3mm thick neoprene rubber gasket joint and nuts, bolts (high tensile), washers etc, and testing, including dismantling & taking out old unserviceable CI sluice valve of 150 mm bore, complete, all as specified & directed. Note : 1. Material required for jointing including cutting/screwing existing pipe/grinding/welding work/Earth work as reuqired include in quoted rate 2. All T&P and vehicles for transpotation will be provide by contractor and no extra payment made out on this account.
(a) 80 dia mm bore.
(b) 100 dia mm bore.
(c) 150 dia mm bore.
(d) 200 dia mm bore.
(e) 250 dia mm bore.
(f) 300 dia mm bore.
(g) 350 dia mm bore.
(h) 450 dia mm bore.
M&L for fixing non return valve (NRV) of following size mm bore, cast iron body, as per IS 5312 (ISI marked), heavy duty, both ends flanged and drilled, including nuts, bolts, washer and neoprene rubber gasket joint complete all as specified and as directed including dismantling & taking out old unserviceable non return valve. Note : 1. Material required for jointing including cutting/screwing existing pipe/grinding/welding work/Earth work as reuqired include in quoted rate 2. All T&P and vehicles for transpotation will be provide by contractor and no extra payment made out on this account.
(a) 80 dia mm bore.
(b) 150 dia mm bore.
(c) 200 dia mm bore.
(d) 250 dia mm bore.
M&L for cast iron foot valve flanged type including all jointing materials such as washers, nut bolts, rubber packing etc and testing complete all as specified ISI marked for following mm dia pipe lines complete all as specified and directed by Engr-in-Charge. Make:- kirlosker,Upadhay,Leader
(a) 100 mm dia
(b) 250 mm dia
Material and labour for repair/ re-construction of existing brick masonary valve pit chamber of size 900x 900 x 600 mm (Internal dimension) using sub class ‘B’ bricks complete, earth work, PCC (1:4:8) type D-2 using 40 mm graded stone aggregate in foundation,brick masanary with sub class bricks 23 cm build in cement mortor with 1:6 , plastering of 10 cm thickness internally and 15 cm externally(1:4) cement mortor and below grond level PCC with 1:2:4 type B2 using 20mm grade stone aggregate ,coping 50 mm thick including frame of size 75x75x6mm made of angles iron and chamber cover made of MS sheet of 4 mm thickness double leaf including MS hinges locking arrangement with provision of locks and keys , painting of the steel surfaces with two coats of synthetic enamel paint over a coat of red oxide primer including necesarry excavation , returning & filling& removing of surplus soil etc complete all as specified and as directed by the Engineer in charge.
Material and labour for repair/ re-construction of existing construction of brick masonary valve pit chamber of size 1500x1500x1500 mm (Internal dimension) using sub class ‘B’ bricks complete, earth work, PCC (1:4:8) type D-2 using 40 mm graded stone aggregate in foundation,brick masanary with sub class bricks 23 cm build in cement mortor with 1:6 , plastering of 10 cm thickness internally and 15 cm externally(1:4) cement mortor and below grond level PCC with 1:2:4 type B2 using 20mm grade stone aggregate ,coping 50 mm thick including frame of size 75x75x6mm made of angles iron and chamber cover made of MS sheet of 4 mm thickness double leaf including MS hinges locking arrangement with provision of locks and keys , painting of the steel surfaces with two coats of synthetic enamel paint over a coat of red oxide primer including necesarry excavation , returning & filling& removing of surplus soil etc complete all as specified and as directed by the Engineer in charge.
M&L for replacement PVC insulated sheathed 3 core submersible flat cable for submersible pumps copper conductor cable (stranded) 1100 volt grade of size 10 Sq mm Make:- Plaza/finolex/ Havells
supply and fixing contactor of following cap of motor including disconnecting and taking down old existing unserviceable contactor Make:- L&T/C&S/Siemens.
(a) Contactor rating suitable for 40 Amp, 3 Pole with (01 No + 01 NC)
(b) Contactor rating suitable for 60 Amp,3 Pole with (01 No + 01 NC)
(c) Contactor rating suitable for 80 Amp,3 Pole with (01 No + 01 NC)
(d) Contactor rating suitable for 100 Amp,3 Pole with (01 No + 01 NC)
(e) Contactor rating suitable for 130 Amp,3 Pole with (01 No + 01 NC)
(f) Contactor rating suitable for 160 Amp, 3 Pole with (01 No + 01 NC)
Supply and fix in replacement star delta timer range 0 - 30 second. Make : C&S/L&T /Schiender
M&L for fixing in replacement motor protection relay of following range in amp as per existing type/model with all connected accessories and deposite ols unsv material to store yard of AGE EM complete all as specified and directed by Engr-in-charge.
(a) Range 13-20 Amp
(b) Range 22-30 Amp
(c) Range 25-39 Amp
(d) Rrange 38-60 Amp
M&L for fully automatic star delta starter 3 phase 440 volts 50 HZ, ML type with suitable relay range and contactors complete with all connections for following capacitys including taking down UNSV star delta starter from existing location and testing complete all as specified and directed by Engr-in-Charge. Note : - Contractor will be deposit items ser No 36 to 45 to store and fixing as per direction by JE E/M & Engr -in- Charge. (Make: L&T / Seimens / Havells)
Scraping old Paint of electric induction motor,NC vertivale/horizontal/ multi staging pump, suction and delivery pipes, sluice/NRV valve of any size and make at boosters/pump house (approx area cover 10 Sqmtr outer side) and painting with one coat of red oxide paint and two coat of synthetic enamel paint of shade asb directed by Engr-in-charge incl writing SM/MES No complete as Specified and directed. Note : (i) Taking down and dismentling of connections and reinstallatiom is incl in quoated rate. (ii) Inner side cleaning of Suction and delivery line and one coat of bitumen paint of booster pumps incl in quoated Rate.
Taking down unsv iron chequired sheet /grill/chanel frame & supply and fix New iron chequired sheet of thickness not less than 6 mm/ grill/chanel frame with angle iron as per existing size including welding and two coat of red oxide paint and one coat of black enamel paint complete all as directed by Engr-in -Charge
Dismantiling & Repairing of Reduction gear box vertical type (Ratio 1/40) of Alum flash mixer and Alum chamber including cleaning of all parts of reduction gear box as directed by Engineer-in-Charge.
Supply and fixing in replacement of the following items against item No 39 & 40 above:-
Star cupling as per exiting
Brass gear wheel as per existing
Ball bearing as per existing
Oil Seal as per existing
Supply and installation of reduction gear box vertical type (Ratio 1/60) including of required parts, testing complete all as specified and directed by Engr-in-Charge.
Contactor ML 1.5 Make : L&T/C&F/Legrand
Relay as per sample
Main switch 32 Amp TPN (Make: Havells/HPL/Siemense
ON/OFF Switch
Single Phase preventor
Timer
Supply and fixing of the following spare parts of slip ring with carbon contactor assambly of walk way bridge.
Carbon of size No : 8
Slip ring of copper as per existing
Supply and installation of reduction gear box, horizental type (Ratio 1/60) of walk way bridge with 3 HP motor three phase and movable walk way bridge foundation assembly including dismantling of old unserviceable one and fixing the new setup on same position Complete all as specified and as directed by Engr-n-charge.
Supply and installation of reduction gear box vertical type (Ratio 1/60) including of required parts, testing complete all as specified and directed by Engr-in-Charge.
Supply and installation of reduction gear box vertical type (Ratio 1/50) including of required parts, testing complete all as specified and directed by Engr-in-Charge.
Supply and installation of reduction gear box vertical type (Ratio 1/40) of Alum flash mixer and Alum chamber including of required parts, testing complete all as specified and directed by Engr-in-Charge.
Repair and servicing carefully of reduction gear box vertical type (Ratio 1/50) including replacement of required parts,testing complete all as specified and directed by Engr-in-Charge.
Supply the following items against item No 44, 45 & 46 above:- Star coupling as per exiting
Brass gear wheel as per exiting
Ball bearing as per exiting Make: SKF/NBC
Oil Seal as per existing.
Replacment of Reduction gear box vertical/horizontal type any ration with (Ratio 1/40) of Alum flash mixer in Alum chamber including connection of all parts of reduction gear box as directed by Engineer-in-Charge.
Taking out old damage/broken pipes & Supply, laying , jointing ,testing and commissioning of DI pipe of size 250 mm bore with both side flanged class K-9 confirming to IS-8329/2000 (latest revision ) suitable for push on joint (rubber gaskets) duly ISI marked incl nut,bolts washer etc, complete all as specified and directed by Engr-in-Charge.
M&L in replacement of metallic antivibration pads with rubber cushion for 75/60/50/40/30/25/20 HP motor pumping set including drilling hole at necessary places on foundation base frame .
Supply and fixing in replacement three phase DOL starter suitable for 2 HP Mono block pump set for clariflucators gear boxes, alum mixtures and alum dozers all as specified and directed by Engineer-in-Charge. Make : L&T/Semons/Havells
PUNIYA POWER CONSTRUCTION (BID ID -3362508)
BIDAWAT ENTERPRISES (BID ID -3359334)
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .