| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹48.1 LAccepted-AOC FLAT NO 301 PEARL APARTMENT PLOT NO 121 SECTOR 8A AIROLI NAVI MUMBAI 400708 | NAVI MUMBAI | THANE | MAHARASHTRA | 400708 | L1 | Accepted-AOC AOC | |
| 2 | L2₹50.8 L+₹1.9 L (3.97%)Rejected-Finance SHOP NO 10 BMC SHOPPING CENTRE MITHA NAGAR GOREGAON WEST MUMBAI 400 104 | MUMBAI | MUMBAI SUBURBAN | MAHARASHTRA | 400104 | L2 | Rejected-Finance Not L1 | |
| 3 | L3₹51.7 L+₹2.9 L (5.85%)Rejected-Finance SWAGAT CO OP HSG SOCIETY LTD 22 303 CHAITANYA SHIVAJI RAJE COMPLEX MHADA COMPLEX OPP EKA NAGAR KANDIVALI W MUMBAI 400 067 | MUMBAI | MUMBAI SUBURBAN | MAHARASHTRA | 400067 | L3 | Rejected-Finance Not L1 | |
| 4 | L4₹51.7 L+₹2.9 L (5.86%)Rejected-Finance 1 14 SUJAL MANSION B BLOCK BHANGWADI KALBADEVI ROAD MUMBAI 400 002 | MUMBAI | MAHARASHTRA | 400002 | L4 | Rejected-Finance Not L1 | |
| 5 | L5₹52.3 L+₹3.4 L (7.02%)Rejected-Finance FLAT NO 404 A WING HILL SIDE RESIDENCY BEHIND KIRTI POLICE SOCIETY KATRAP BADLAPUR EAST DIST THANE MAHARASHTRA 451503 | 451503 | L5 | Rejected-Finance Not L1 |
| Sl No | Description | Qty | Unit | R J ENTERPRISES L1 | Shree Ayyappa Engineering L2 | Chakshu Enterprise L4 | cooltech engineering services L3 | M/S SOMANATH ENTERPRISES L5 |
|---|---|---|---|---|---|---|---|---|
| 1.00 | Taking down carefully point wiring of any type & pattern (Light/Fan/Socket or power) including fittings such as switches, ceiling roses, pendants, regulators, sockets, light fittings of any type etc and making good disturbed surfaces of walls/ roof etc, complete all as specified and directed. | 590 | Point | 50 ₹29,500 Lowest | 50 ₹29,500 Lowest | 60 ₹35,400 | 100 ₹59,000 | 105 ₹61,950 |
| 2.00 | M & L for point wiring with PVC insulated FRLS unsheathed 1100 Volts grade single core multistranded copper conductor cable 1.5 Sqmm drawn in and including PVC casing-caping, fixed on wall / ceiling with all accessories, fittings, PVC junction boxes etc, with suitabe sunk pressed steel boxes for modular fittings not less than 1.6 mm thick, etc with necessary fixing accessories and earth continuity conductor cable of 1.5 Sqmm size connected to common earth and earth dolly including 1.6 mm thick pressed steel terminal boxes concealed in wall covered with laminated sheet top cover 3 mm thick for mounting switches / sockets / fan regulators fixed with Cadmium plated machine screws all as specified for one light / fan / bell point controlled by one switch. | 300 | Point | 960 ₹2,88,000 | 725 ₹2,17,500 | 990 ₹2,97,000 | 600 ₹1,80,000 Lowest | 605 ₹1,81,500 |
| 3.00 | -Ditto- all as per item No 02 here-in-before but for one 5A 2pin/3pin socket out let multipurpose on the same board with other switches. | 80 | Point | 250 ₹20,000 | 165 ₹13,200 Lowest | 230 ₹18,400 | 200 ₹16,000 | 205 ₹16,400 |
| 4.00 | -Ditto- all as per item No 02 here-in-before but for one 5A 2pin/3pin switch socket out let multipurpose on independent Board. | 120 | Point | 980 ₹1,17,600 | 725 ₹87,000 Lowest | 970 ₹1,16,400 | 800 ₹96,000 | 805 ₹96,600 |
| 5.00 | All as per item No. 02 above but wiring complete with 2.5 Sqmm for 3 pin 15A socket multipurpose on independent board | 90 | Point | 1,300 ₹1,17,000 | 875 ₹78,750 | 1,400 ₹1,26,000 | 600 ₹54,000 Lowest | 601 ₹54,090 |
| 6.00 | S&F modular type 6A one way SP switch 1 module confirming to IS: 3854-1997 with fingure proof terminal complete all as specified and directed. | 200 | Each | 115 ₹23,000 | 250 ₹50,000 | 110 ₹22,000 Lowest | 300 ₹60,000 | 310 ₹62,000 |
| 7.00 | S&F modular type 2/3 pin combined shuttered type 6 Amps socket 2 module conforming to IS: 1293-2005 complete all as specified and directed. | 100 | Each | 350 ₹35,000 | 325 ₹32,500 | 360 ₹36,000 | 300 ₹30,000 Lowest | 310 ₹31,000 |
| 8.00 | S&F modular type 2/3 pin combined shuttered typr 16 Amps socket 2 module conforming to IS: 1293-2005 complete all as specified and directed. | 50 | Each | 380 ₹19,000 Lowest | 500 ₹25,000 | 390 ₹19,500 | 510 ₹25,500 | 512 ₹25,600 |
| 9.00 | S&F modular type 16 A one way SP switch 1 module confirming to IS: 3854-1997 with finguer proof terminal complete all as specified and directed. | 50 | Each | 390 ₹19,500 | 340 ₹17,000 Lowest | 610 ₹30,500 | 500 ₹25,000 | 510 ₹25,500 |
| 10.00 | S&F modular type 120W step fan regulator of 2 module size conformng to IS: 11037-1984 complete all as specified and directed. | 150 | Each | 590 ₹88,500 | 1,000 ₹1,50,000 | 570 ₹85,500 | 500 ₹75,000 Lowest | 510 ₹76,500 |
Tender Value
Refer Docs
EMD Value
₹99,000
Closing Date
30 Jul 2025, 6:00 pmClosed
GE NW Mankhurd
GE NW Mankhurd MUMBAI-88
REPAIR / MAINTENANCE OF INTERNAL ELECTRIFICATION AT DOMESTIC AREA, SECURITY LIGHTS, UG CABLES, POST TOP LANTERN AND GARDEN LIGHTS AT TECHNICAL AREAS AT MANKHURD AND OTHER MAINT WORKS AT NRS THANE AND 31 WEU UNDER GE (NW) MANKHURD
2025_MES_719419_1
8461/E8
Open Tender
Civil Works
Item Rate
270 days
GE NW Mankhurd
As per Tender Documents
8 documents required · 8 mandatory
₹500
GE NW Mankhurd
₹99,000
19 Sept 2025
9 Jul 2025
1 Aug 2025
9 Jul 2025
30 Jul 2025
23 Jul 2025
Amount
Taking down carefully point wiring of any type & pattern (Light/Fan/Socket or power) including fittings such as switches, ceiling roses, pendants, regulators, sockets, light fittings of any type etc and making good disturbed surfaces of walls/ roof etc, complete all as specified and directed.
M & L for point wiring with PVC insulated FRLS unsheathed 1100 Volts grade single core multistranded copper conductor cable 1.5 Sqmm drawn in and including PVC casing-caping, fixed on wall / ceiling with all accessories, fittings, PVC junction boxes etc, with suitabe sunk pressed steel boxes for modular fittings not less than 1.6 mm thick, etc with necessary fixing accessories and earth continuity conductor cable of 1.5 Sqmm size connected to common earth and earth dolly including 1.6 mm thick pressed steel terminal boxes concealed in wall covered with laminated sheet top cover 3 mm thick for mounting switches / sockets / fan regulators fixed with Cadmium plated machine screws all as specified for one light / fan / bell point controlled by one switch.
-Ditto- all as per item No 02 here-in-before but for one 5A 2pin/3pin socket out let multipurpose on the same board with other switches.
-Ditto- all as per item No 02 here-in-before but for one 5A 2pin/3pin switch socket out let multipurpose on independent Board.
All as per item No. 02 above but wiring complete with 2.5 Sqmm for 3 pin 15A socket multipurpose on independent board
S&F modular type 6A one way SP switch 1 module confirming to IS: 3854-1997 with fingure proof terminal complete all as specified and directed.
S&F modular type 2/3 pin combined shuttered type 6 Amps socket 2 module conforming to IS: 1293-2005 complete all as specified and directed.
S&F modular type 2/3 pin combined shuttered typr 16 Amps socket 2 module conforming to IS: 1293-2005 complete all as specified and directed.
S&F modular type 16 A one way SP switch 1 module confirming to IS: 3854-1997 with finguer proof terminal complete all as specified and directed.
S&F modular type 120W step fan regulator of 2 module size conformng to IS: 11037-1984 complete all as specified and directed.
Supply & Fix Modular Bell push flush type 6 Amp, 1 module, 230 Volts complete all as specified and directed.
Supply and fix bell ding dong AC 230 V single pole. complete all as specified and directed.
S & F Modular Blank plate 1 module suitable for Modular switch boards all as specified and as directed
S & F Modular cover plate 8 modules
S & F Modular cover plate 4 modules
S & F Modular cover plate 3 modules
S & F Modular cover plate 6 modules
S & F Modular cover plate 1 modules
S&F ceiling rose three terminal, 230 Volts PVC / Polycarbonate body, complete all as specified and directed.
S&F in repairs Surface, hanging and wall mounted batten (Double side connection) suitable for LED tube 20/22 watts, 230 volts alongwith tube rod 22 watt (double side connection), including fixing mounting blocks 2 Nos, 15 mm MS conduit, 1.5 sqmm 3 core pvc insulated copper conductor cable including fixing arrangements complete all as specified and directed. Make :- BAJAJ/ PHILLIPS/ JAQUAR/ WIPRO
Supply and fixing Electronic Meter 10-60 amps Single phase tamper proof with Class 1 accuracy Optical port,LED Indication for earth leakage ,Elegant Polycarbonate Enclosure,High Surge withstand up To 8kv ,anti tamper features,Electromagnetic compatible & 6 digit Display. Make L&T/ HPL or equivalent as approved by GE. Note : Old unserviceable Meter will be deposit to MES.
M&L for testing of old earthing using calibrated earth tester & submitting result to engr -in -charge all as directed. Note : (i) Watering of earthing with 2 Buckets (30Ltrs) water mixed with salt (total 20Kg) shall be carried out one day before the testing & the cost of the same shall deemed included in unit rate quoted.
M&L for painting on wall with synthetic enameled paint of black colour as background of 200 x 150 mm size and writing for earth test result with date & year all as specified and directed at site by Engineer-in-Charge.
Excavation in trenches not exc 1.5 mtr wide and not exc 1.5 mtr in depth and getting out in in any type of soil Note - Cable Cover Found serviceable shall be kept in safe custody and shall be relayed under respective item.
Returning filling in , excavated soil including spreading, leveling and well ramming in layers not exc 25cms each any type of soil.
Removing the excavated materials not exc 50mtr and depositing where directed at a level not exceeding 1.5 mtr above the staring point all as directed by Engr - in- Charge.
M&L for sand cushioning by spreading in trenches fine dry river sand by gently by punning down manually as in cable protection all as specified and as directed by EIC.
Supply and laying precast concrete cable cover class LV ISI Marked, type-I, flat size 250mm x 150mm x 40mm laid in trenches all as specified.
Laying only precast concrete cable cover class LV type in trenches all as specified.
M&L for locating of faults of LT under ground cable PILCA/XLPE upto 400 Sqmm size by using computerised / primary current injection method including cutting and removing the faulty portion of the cable and jointing with suitable cable joint and testing after jointing all as required and directed at site. Notes:-(i) Excavation, earth work, sand cushioning, PCC cover etc will be measured and paid separately under relevant items of BOQ. (ii) Cable joint will be measured and paid separately. (iii) Additional length of cable required at site for jointing will be measured and paid separately.
M&L for straight through joint (HEAT SHRINKABLE TYPE KITS) for underground cable including joint kits and labour complete for making joints suitable for LT, XLE/PILC/PVC sheathed armoured heavy duty cable with aluminium conductor 3.5/4 core up to to 50 Sqmm incl taking down existing terminal joints.
-Ditto- all as per item No 33 here-in-before but 3.5/4 core 70 Sqmm to 150 Sqmm size -do-
-Ditto- all as per item No 33 here-in-before but 3.5/4 core 185 Sqmm to 400 Sqmm size -do-
Supply & Lay or fixing or passing through pipe, XLPE/PVC insulated, armoured heavy duty 1100 volt grade electric LT UG cable with aluminium conductor of size 10 Sqmm 4 Core in trenches/along the wall/including takingdown old unsv cable and making all connections complete with lugs as required at site and as directed by Engr-in-Charge. Make - Havells/Polycab/Plaza/KEI.
M&L for cutting existing road/hard standing not exc 45x45 cm in wide & depth getting out excavated material for laying GI tube ;returning filling & well rammaing watering finish suraface 10 cm from top using PCC 1:3:6; including removal of surplase soil all as directed
S& F in replacement of GI steel tubing light grade 40 mm dia for laying in ground, along the pole in coping, road crossing etc for cabe protection including necessary fittings , clamps for supports, etc all as directed by Engineer in charge Make - Tata/Jindal/Surya Prakash
Supply and fix in replacement of FRP looping box of size 155x210x92 mm with connector, MCB 6 Amps, Din Rail, GI clamps made out of GI flat of size 25mm X 3 mm channel including providing detachable GI 3 mm thick plate inside looping box as cable gland plate and including cable gkands as required at size and making connections all as specified and directed by Engineer –in –Charge.Make - National / Sintex
M&L for taking down old unsv and supply & lay 3 Core 1.5 Sq mm size multistranded copper conductor PVC unsheathed 650 / 1100 Volt Grade As per IS 694 with and including 20 mm dia PVC conduit and passing through PVC conduit with necessary saddle, clamps, bolts & nuts, all For interconnection of cable looping box to Street Light Fitting, Post Top Lantern etc all as Directed.
M&L for Multistandarded Copper Conductor cable of 3 Core 1.5 Sq mm size drawn through steel tubular poles for interconnection of cable looping box to Street Light Fitting, Post Top Lantern etc taking down old unsv cable all as Directed. Make :- Havells/ Polycab/Plaza/KEI
M&L for sub main wiring with two single core 2.5 Sqmm PVC insulated FRLS multistranded flexible copper conductor cable 660/1100 volts grade down in through non metalic PVC casing caping with and including PVC insulated 2.5 Sqmm single core single strand copper conductor as continous earth wire in green colour connected to common earth dolly all as specified and as directed. (Make :- PRESFIT/ PRECISION - Casing caping), (Make :- FINOLEX/ KEI/ POLYCAB - PVC Copper wire) Note : 1. Two runs of cable, one run of earth wire, one run of PVC casing capping of 2.5 sqmm will be measured and paid one unit.
M&L in repairs 1 output 16 A-250 V 50/60 Hz Digital Time Switch with Astronomical function 56 for switching on/off lights and other electric devices with daily astronomical calculation of the sunrise/sunset times based on the entered location or location coordinates complete all as directed by Engr-in - Charge .Make legrand Cat No. 412654 or equivalent of L&T/Indo Asian as approved by GE
M&L in repairs for 24 Hrs 240 V FM1 Quartz type Time switches astronomical type (Having longitude and latitude of Indian cities in memory) timer for controlling street lights contactors complete all as directed by Engr-in - Charge .Make :-Legrand/ L&T/Indo Asian as approved by GE
M&L to attend the LED Solar Light fittings of 18 wattage. Service Representative will Carry scheduled preventative maintenance checks as per details given below at Mankhurd
a)Solar PV Modules - Check the Circuit Voltage and current characteristics. Also, check the mechanical integrity of the Solar PV Modules.
b)Battery Bank -Check the Specific Gravity of the Electrolyte, Electrolyte level, battery terminals, Battery Bank box and adding Electrolyte solution if required. NOTE Electrolyte solution will be measured seprately under this Schedule.
c)Solar PCU - Check DC input Voltage and Current, Check AC input Voltage and Current, checking the wiring.
d)Module Mounting Structures -Check the mechanical integrity of the Solar PV Modules Mounting Structures. Ensure that there is no corrosion set up on the MMS and the module is firmly fixed.
e) System Wiring - Check the system wiring including the insulations, cable lugs and rewiring/soldering ifa any required
f)Module Cleanliness - Cleaning of the dust accumulated over the Solar Module, and taking corrective measures
M&L for preparation of old painted surfaces of Solar Street Light Poles including acessories by scarping old paint and applying two coats of paint including numbering of pole with black oil paint all as directed by Engineer in Charge
Supply and fix in replacement of LED 18 watt DC solar light fitting Make - Emvee / ICPC Solar
Supply and fix inreplacement of low maintenance VRLA lead acidic battery of 120 AH suitable for 1 x 18 watt Soalr Light fitting all as per recommanded by Manufracturer
Supply and fix inreplacement of charge controller suitable for 18 watt Solar Light fittings incluing any wiring as required
Supply only electrolyte solution to be incorporated in servicing, suitable for Solar charged battery of any capacity.
Supply and fix in replacement street light fittings in street light poles/Buildings the fitting shall be of LED type 60 Watts complete with and including drivers, pressure die cast aluminium housing, prewired complete. Make-Havells/Crompton/Bajaj.
Supply and fix in replacement flood light fittings in street light poles/Buildings the fitting shall be of LED type 120 Watts complete with and including drivers, pressure die cast aluminium housing, prewired complete. Make-Havells/Crompton/Bajaj.
Supply and fix in replacement flood light fittings in street light poles/Buildings the fitting shall be of LED type 300 Watts complete with and including drivers, pressure die cast aluminium housing, prewired complete. Make-Havells/Crompton/Bajaj.
M & L for PCC 1:2:4, type B-1, (using 20mm graded stone aggregate) as in coping including necessary use & waste of form work including demolition of PCC foundation / Pole coping from ground level complete all as specified and directed.
Supply and fix in replacement 8/9 Watt LED Bollard garden light fitting with efficient high output COB LED, pressue die cast powder coated housing with PC diffuser driver nut bolt ,washer base plate foundation 0.3 mtrx0.3 mtr x.40 mtr by PCC 1:2:4 type B-1 using 20mm grade stone aggegates of size including excavtion and earth work , provision of GI bend of size 50MM dia in the PCC for cable entry all as specified and directed in EIC. Make:- HAVELLS/ PHILLIPS/ JAQUAR/ WIPRO/BAJAJ.
Suply and fix New generation , Post-top LED warm light 35/40 W,energy saving, environmental friendly, long life aesthetically designed with symmetrical light distribution,spun aluminium landscape luminaire with high power LEDs as light provision of GI bend of size 40 mm dia in the PCC for cable entry the fitting with nut bolts,washer all as specified and directed in EIC. Make:- HAVELLS/ PHILLIPS/ JAQUAR/ WIPRO.
Suply and fix New generation , Post-top LED warm light 15/ 20 W,energy saving, environmental friendly, long life aesthetically designed with symmetrical light distribution,spun aluminium landscape luminaire with high power LEDs as light provision of GI bend of size 40 mm dia in the PCC for cable entry the fitting with nut bolts,washer all as specified and directed in EIC. Make:- HAVELLS/ PHILLIPS/ JAQUAR/ WIPRO.
S & F MCB DB, 12 way, SPN, double door, 240 Volts and including cutting chases in wall, concealing DB in wall, making good the disturbed surfaces and making all connections complete including taking down old u/s DB's all as specified and directed. Note: Quoted rate shall be deemed to include for provision of copper bus bar of 200 Amps rating.
S & F MCB DB, 8 way, SPN, double door, 240 Volts and including cutting chases in wall, concealing DB in wall, making good the disturbed surfaces and making all connections complete including taking down old u/s DB's all as specified and directed. Note: Quoted rate shall be deemed to include for provision of copper bus bar of 200 Amps rating.
S & F MCB DB, 4 way, SPN, double door, 240 Volts and including cutting chases in wall, concealing DB in wall, making good the disturbed surfaces and making all connections complete including taking down old u/s DB's all as specified and directed. Note: Quoted rate shall be deemed to include for provision of copper bus bar of 200 Amps rating.
S & F in repairs MCB SPN 40 Amps, 240 / 415 Volts, 50 Hz, 10 KA Breaking capacity 'C' Series complete all as specified and directed. Make - Legrand/ L&T/ Schneider/Bentec
S & F in repairs MCB SP 5 to 32 Amps, 240 / 415 Volts, 50 Hz, 10 KA Breaking capacity 'C' Series complete all as specified and directed. Make - Legrand/ L&T/ Schneider/Bentec
Supply and fix in replacement street light fittings in street light poles/Buildings the fitting shall be of LED type 35 Watts complete with and including drivers, pressure die cast aluminium housing, prewired complete. Make-Havells/Crompton/Bajaj.
M&L Earthing complete with galvanised steel earth plate electrode 60 x 60 CM x 6mm thick buried directly in ground (earth pit not less than 2.25 metres deep below ground level)with top edge of the plate not less than 1.5 metres below normal ground level,connected to galvanised earth lead wire 4.0mm dia by means of bolts nuts check nuts and washers of galvanised iron or steel all as shown in electrical plate No.3 connected to earthing test point all as specified or indicated including testing on completion including dismantling of existing earthing Complete all as specified and directed.
S&F piano type 5A one way SP switch 1 module confirming to IS: 3854-1997 with fingure proof terminal complete all as specified and directed.
S&F flush type 2/3 pin combined shuttered type 5 Amps socket 2 module conforming to IS: 1293-2005 complete all as specified and directed.
S&F flush type 2/3 pin combined flush type 5/15 Amps socket 2 module conforming to IS: 1293-2005 complete all as specified and directed.
S&F flush type 15 A one way SP switch 1 module confirming to IS: 3854-1997 with finguer proof terminal complete all as specified and directed.
Supply and fixing condenser 2.5 MFD with PVC clamp.
Supply and fix exhaust fan made of sturdy Engineering plastic complete with louvers shutter, voltage 230V, 50 Hz, RPM 1200, Copper winding of sweep 250m complete all as specified and directed. Make :- ALMONARD / ORIENT
Daily door to door repair/replacement of maintenance for Md Accn bldg covered under GE (NW) Mankhurd area (a) Thane by team of contractor's comprises of (a) One Electrician and 01 x Helper will be carried out daily under restective area :- Note 1 :- (a) Contractor will be assigned to visit one area daily alongwith man and material as per as per direction of Engineer-In-Charge and he will perform all petty repair work as demanded by user of bldg. (b) Contractor will make his own arrangement for to and fro of his team and his rates shall be inclusive of this aspect. (c) The material component require for above complaint will be measured and paid as “Supply only” under respective item of this schedule. Certain material may be issued from the department free of cost for fixing only as per direction of Engineer-in-Charge. (d) If contractor fails to attend the area, a sum of Rs 4000/- per days will be recovered on account of non attedance of petty repair work from any legitimate payment due to contractor. A sum of Rs 500 per false complaint/wrong signature will also be recovered from the contractor.
(e) Contractor will also attend the petty repair work on all days of week i.e Working day as per direction of Engineer-in-Charge. (f) Contractor will obtain log sheet of repair work perform by him duly signed by occupant user and authorised user rep both. (g) Rep of contractor, Rep of GE Office and Rep of User alongwith labour team (Carpenter, Plumber, Electrician and helper) will visit door to door and get the user complaint and rectified on the same day. (h) A detailed log of complaints with completion/ non-completion remarks from users/MES will be maintained by the contractor and same will be updated on daily basis in consulatation with Engr-in-Charge or JE detailed by him. (j) The contractor will make suitable arrangment for emergent complaints and will notify auth rep/Engr-in-Charge about extraordinary circumstances for probable non-completion or delay in rectification of complaints beyond state time limit set for disposal of complaint. In case of any dispute the decision of accepting officer will be final and binding in this regard. (k) The quoted rate deemed to be inclusive of transportation and other expenses required for the resource deployment at the complaint site around scattered Naval Depot and area like Mahul, Thane etc. Note 3. Contractor should includes cost of fixing joinery, plumbing and electricals works like screws, teflon tapes, insulation tapes, washers etc
Supply and fix in repairs hi wall split units indoor complete with cordless remote control unit and with in built air ioniser and plasma filter for better indoor air quality including taking down old u/s indoor AC unit of capacity 2 Ton electric driven single phase 230 Volt complete all as specified and directed.
-ditto- all as per item No 70 above but for 1.5 Ton capacity complete all as specified and directed.
Supply and fix in repairs hi wall split units outdoor (Condener unit) of capacity 2 Ton including filling of refrigerant including taking down old u/s outdoor AC unit complete all as specified and directed.
-ditto- all as per item No 72 above but for 1.5 Ton capacity complete all as specified and directed.
Supply only in repairs cordless remote control unit suitable for capacity of 2 / 1.5 Ton suitable for window/ Split AC complete all as specified and directed.
Material and labour for servicing of A/C window type or split type A/C, tower AC of capacity 1.5/2/2.5 TR including washing with sodash the cooling coil/condensor coil base body drying with air blower checking complete wiring testing and re-installing in situ and testing the unit.
M & L for dismentling unserviceable compressor from the window type AC, Split type A/C 1.5 TR/ 2.0 TR capacity from any location , supply and fix new hermatically sealed compressor unit , assembling, brazing pressure/vaccum testing initial oil charging, gas charging,reinstalling A/C in situ and connecting to electric supply and testing all as directed and specified. Make : Voltas/Carrier/Kirloskar /bluestar Note : (i) Job including removing A/C from any site/height/location (ii) Transporting A/C unit to repair workshop and back to site (iii) Loading/unloading etc
Supply and fix in repair Relay for A/C split/window type,Tower AC complete all as specified and directed.
Supply and fix in repair Relay for WATER COOLER/DEEP FREEZER complete all as specified and directed.
Supply and fix in repair Thermostat for A/C 1.5 TR/2 TR,Tower AC complete all as specified and directed.
-ditto- all as per item No 79 but for water cooler of any capacity complete all as specified and directed.
Supply and fix in repair Air filtter for window type/split type AC, Tower AC as per sample complete all as specified and directed.
Supply and fix in repair Starting capacitor 80-100 mfd 220 volt 50 HZ complete all as specified and directed.
Supply and fix Starting capacitor of capacity 120 - 150 MFD for 2 TR, 2.5 TR capacity complete all as specified and directed.
Supply and fixing in repair of Running capacitors of capacity 45 MFD 220 volt 50Hz complete all as specified and directed by Engr-in-Charge
Supply and fix in repairsLED Light fitting 1 x 16 Watt flame proof MM52 CMRI certified recommended for gas/vapour group IIA & IIB,zone 1&2 and IP 65 protection with die cast aluminium housing with heat resistant toughened glass with LED tune light fixtures drivers holders connectors etc including taking down complete all as specified and directed.
Supply and fixing in repairs ceiling fans complete with blades,down rods,electronic regulator and accessories,230V,1200mm sweep Min air delivery 210CFM with service value 6.00 BEE five star rated with brushless direct current motor.including taking down of existing fan and deposit in MES Stores.Make: Bajaj Energos 26,Orient,Havells,Almonard.
Supply and fix in repairs Water heater storage type steel body with copper inner tank and heating element upto 2KW capacity 25 Litre,BEE 5 star rated including taking down and deposit in MES Store complete all as specified and directed.
Note : A SUM OF RS 73890.00 TOWARDS SCHEDULE OF CREDIT SHALL BE DEDUCTED TO ARRIVE THE CONTRACT SUM
Shree Ayyappa Engineering (BID ID -3377174)
cooltech engineering services (BID ID -3377502)
Chakshu Enterprise (BID ID -3377496)
M/S SOMANATH ENTERPRISES (BID ID -3377622)
stage.html
html • 0.06 MB
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .