| 1 | 1₹20.1 LAccepted-AOC | 1 | Accepted-AOC Due to L-1 and credit | |
| 2 | 2₹23.8 L+₹2.4 L (11.4%)Rejected-Finance H NO 2 ADARSH NAGAR ARJUN NAGAR NEAR MITTAL NURSING HOME AGRA 282001 | AGRA | AGRA | UTTAR PRADESH | 282001 | 2 | Rejected-Finance Being other than L-1 | |
| 3 | 3₹24.0 L+₹2.7 L (12.5%)Rejected-Finance | 3 | Rejected-Finance Being other than L-1 | |
| 4 | 4₹24.2 L+₹2.9 L (13.5%)Rejected-Finance 43 VIMAL ENCLAVE CHAMRAULI MODE SHAMSHABAD ROAD AGRA UP 282001 | AGRA | AGRA | UTTAR PRADESH | 282001 | 4 | Rejected-Finance Being other than L-1 | |
| 5 | 5₹24.5 L+₹3.2 L (14.9%)Rejected-Finance 64 250 2 COD ROAD HASTINAPURI MADHU NAGAR AGRA 282001 | AGRA | AGRA | UTTAR PRADESH | 282001 | 5 | Rejected-Finance Being other than L-1 |
Tender Value
₹30 L
EMD Value
₹60,000
Closing Date
12 Jun 2024, 6:00 pmClosed
GE (AF) ADM AREA AGRA
GE (AF) Adm Area Agra 282008
REPAIR REPLACEMENT OF INTERNAL WIRING INCLUDING FITTING, FIXTURE AND OTHER CONNECTED WORK IN OFICER ACCN, MAP AREA ANC , 2 AREA UNDER GE (AF) ADM AREA AGRA.
2024_MES_654452_1
8000-2143/E8
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
GE (AF) ADM AREA AGRA
Please refer Tender documents.
4 documents required · 4 mandatory
₹500
GE (AF) ADM AREA AGRA
₹60,000
Yes
12 Jul 2024
17 May 2024
14 Jun 2024
17 May 2024
12 Jun 2024
31 May 2024
Amount
Taking down copper/ aluminium point wiring (light, fan, socket or power) complete including fixture and fittings such as switches, ceiling roses, pendants, regulators, sockets, light fittings etc. removing materials to store for keeping in safe custody or for taking credit and making good disturbed surfaces of walls, floors etc. to match the existing complete all as specified and directed. NOTE: Credit for this items shall be made as per conditions separately.
M&L for point wiring complete for one light/fan/ exhaust fan point controlled by one, one way 5 Amp switch with PVC (FRLSH) insulated unsheathed multistranded copper conductor of size 1.50 sqmm nominal cross sectional area single core drawn in and including minimum 20 mm dia 'medium grade' PVC concealed conduits ISI marked and fittings, including anodised pressed steel concealed terminal switch boxes not less than 1.20 mm thick of reqd size factory made duly painted inside and outside with one coat red oxide primer, 3mm thick plastic laminated bakelite sheet top cover (ISI Marked) fitted with chromium plated brass screws & washers complete including 1.50 sqmm nominal cross sectional area PVC(FRLSH) insulated unsheathed multistranded copper conductor green as earth wire connected to earth dolly with all accessories including cutting chases for concealed piping and making good disturbed surface to match the existing surface complete all as specified and directed.
All as per srl item No 2 above but for call bell point complete all as specified and directed.
All as per srl item No 2 above but for 5 pin 5 amps socket outlet independent board complete all as specified and directed.
All as per srl item No 2 above but for 3 pin 5 amps socket outlet on the same board with other switch complete all as specified and directed.
All as per srl item No 2 above but for one light point controlled by two Nos 2 way switches complete all as specified and directed.
All as per Item No 02 above but for one 6 pin 15/16 amps socket outlet point on an independent board with cables of size 2.50 Sqmm and green colour earth cable of size 2.50 Sqmm.
M&L for point wiring complete with PVC (FRLSH) insulated unsheathed multistranded copper conductor of size 4 sqmm nominal cross sectional area single core drawn in and including not less than 20 mm dia 'medium grade' PVC concealed conduits ISI marked and fittings, complete including 4 sqmm nominal cross sectional area PVC(FRLSH) insulated unsheathed multistranded copper conductor green as earth wire connected to earth dolly with all accessories including cutting chases for concealed piping and making good disturbed surface to match the existing surface complete all as specified and directed.
S&F in replacement switch piano flush type one way 5 amps SP 240 volts complete all as specified and directed.
S&F in replacement switch piano 2- way, 5/6 amps flush type 230 volts complete all as specified and directed.
S&F in replacement bell push flush type 5 amps SP 240 volts complete all as specified and directed.
S&F in replacement switch in replacement piano flush type one way 16 amps SP 240 volts complete all as specified and directed.
S&F in replacement socket outlet 2 in 1, 3 pin 5/6 amps flush type 240 volts complete all as specified and directed.
S&F in replacement socket outlet 2 in 1, 6 pin, 5 and 15 amps flush type 230 volts complete all as specified and directed.
S&F in replacement bell ding dong AC , 230 VOLTS, single pole complete all as specified and directed.
S&F ceiling rose 65 x 50mm three terminals complete all as specified and directed.
S&F in replacement ceiling fan regulator, electronic stepped type 5 stage speed regulation, ISI marked complete all as specified and directed.
S & F in replacement lamp holder/batton holder/angle holder insulated body with bakelite back plate suitable for fittings complete all as specified and directed.
S & F sheet metal single pole and neutral enclosure with socket, plug top complete with one single pole MCB of 20 Amps, 240 volts complete all as spd and directed.
M&L for point wiring complete for one light/fan/ exhaust fan point controlled by one, one way 5 Amp switch with PVC (FRLSH) insulated unsheathed multistranded copper conductor of size 1.50 sqmm nominal cross sectional area single core drawn in and including minimum 20 mm dia 'medium grade' PVC concealed conduits ISI marked and fittings, including concealed terminal switch boxes for modular switches, modular plate and cover of suitable size for fixing switchs, sockets, regulators etc. including 1.50 sqmm nominal cross sectional area PVC(FRLSH) insulated unsheathed multistranded copper conductor green as earth wire connected to earth dolly with all accessories including cutting chases for concealed piping and making good disturbed surface to match the existing surface complete all as specified and directed. Note- (i) Rates include the cost of modular plate modular boxes and covers of suitable modules as required at site. (ii) Modular box, plate and cover shall be of same make as of switch//socket/regulator.
All as per item No. 20 above but for one 5 pin 5/6 Amp socket outlet point on an independent board.
All as per item No. 20 above but for one 5 pin 5/6 Amp socket outlet point on the same board with other switch.
All as per Item No 20 above but for one 6 pin 15/16 amps socket outlet point on an independent board with cables of size 2.50 Sqmm and green colour earth cable of size 2.50 Sqmm.
S & F modular type switch 1- way 6-Amps, with led indication lamp 240 Volt , 1 Module complete all as specified and directed.
S & F modular type switch 1- way 16-Amps, 240 Volt , 1 Module complete all as specified and directed.
S & F modular type socket 3-Pin , 6-Amps, 240 Volt , 2 Module complete all as specified and directed.
S & F modular type socket 3-Pin combined , 6/16-Amps, 240 Volt , 2 Module complete all as specified and directed.
S & F modular type fan regulator, 240 Volt , 2 Module complete all as specified and directed.
S&F in replacement existing U/S light fitting with energy saving decorative LED batten 20 watt (4 Feet), 230 voltas, energy efficient tube light fitting extruded aluminium housing provided for efficient heat dissipation with polycarbonate diffusre & integrated electronic driver complete with all accessories prewired and includeing making connections with 3 core twisted flexible copper cable of size 23/.0076 from ceilling rose/PVC connector to light fittings complete all as specified and directed. Note:- Power factor should not be less thtn 0.95 Make- HALONIX Cat paart No - HLTLD-04-20-CW , ORIENT Cat part No-LBLN-20-C-AL /Phlips Cat part No- BN021C LED22S PSU CW GR
S&F in replacement of old U/S tube light fitting with energy saving decorative batten type 10 watt energy efficient tube light fitting (2 Feet) highly durable surface mounted LED batten constructed of fire retardent engineering grade extruded plastic and decorative end caps with all accessories prewired and making connection with 3 core copper flexible cable of size 23/.0076 from ceilling rose/PVC connector to light fittings complete all as specified and directed. Make- ORIENT Cat part No-LBLN-10-C-SQ/Phlips cat part- BN021LED12S6500PSUGR, HALONIX Cat part no HLTLD-04-10-CW
S&F in replacement of old U/S decorative wall mounting light fittings with opal glass diffuser and stainless steel body suitable for LED lamp 12 Watt (B-22 base) including one number 12 Watt LED lamp complete all specified and directed. Make: HALONIX Cat part No HLWB-01-B22,/Havells - LHFOAJE1TN1I060 /PHLIPS
S&F in replacement enery saving new generation LED 10 Watts, 6000k, IP-65 bulk head luminarie with opal diffuser complete including making connection with 3 core copper flexible cable of size 23/.0076 from ceilling rose/PVC connector to light fittings complete all as specified and directed. Make :- ORIENT /Phlips / Havells
S&F for replacement of existing unsv security light fittings with LED security light fitting 30/36 Watts, excellent thermally managed pressure die cast alumnium come with in-built photo sensor for automatic on/off, IP-66 including GI bracket made out of GI pipe 40 mm bore medium grade bent to an angle of 135 degree and reduced at the end to 32 mm dia, 1.20 mtr long including 2 Nos clamps, suitable size of nut, bolts complete all as specified and directed. Make: Halonix cat part LED SL 30WHLSLD-ML04-30-CWL-INV-RTC-R/ Orient Cat No: LSFT-36-C-PCK-DLS/ SHAKTI CAT REF
S&F in replacement exisitng unsv Lamp with LED Lamp 9 watt, 6500 K, 230 volts B-22 Base complete all as specified and directed. Make: Havells/ Philips/ Bajaj
S&F in replacement 20 W LED tube with in built driver complete all as specified and directed. Make :- Havells Cat part No-LHLDDCXCML8Q020, Orient Cat part No. LTXL-20-C / Halonix - HLTLD-04-20-CW-PC
S&F 20 watt LED building security light made up of pressure die cast aluminium housing with high power LED as lighting source and lens embeded toughened glass having top opening seperate driver compartment with min IP65 protection connecting the same to making connection with 3 core copper flexible cable of size 23/.0076 from ceilling rose complete all as specified and as directed. Make:- Orient Cat No :LSFS-020-C/ Bajaj Cat No-ENXT P 20L WH PO PC SD/ Halonix Cat No- HLSLD-09H20CWL R
Material and labour in replacement of GI tubing light grade 40 mm bore for fixing of garden / gate post top lantern including making hole or for passing through cables laid under the floor, along the wall or along the pole complete all as specified and directed .
S & F in replacement post top lantern 30/35 Watts, 230 volts, 50 Hz with IP65 protection, mushroom or oval shaped in opal/ prismatic finish made out of polycarbonate, suitable all accessories and prewired complete all as spd and directed. Make:- Havells Cat Ref RUBYPT35WLED830PSYMTOPC/ Orient Cat No :LLOP-30-C or equivalent in Phillips.
S & F of bedside light of 3 W capacity of output 70-80 lumen having adjustable heads to change its focus area complete all as specified and directed. Make:Philips 48042/30/31 or equivalent in Havells/Crompton.
S & F in replacement LED bollard of 9/10 watts, 230 volts, 50 Hz with IP 65 protection with robust design and efficient light distribution complete all as spd and directed. Make:- Havells Cat Ref MOUNTBL 10WLED857PSYM TOPMMA(0.6M)/ Orient Cat No :LLSBL-10-W-B/ Phillips Cat Ref BCP400 LED09 D CW PSU GR S1
S & F in replacement decorative gate light made up of high grade unbreakable polycorbonate material suitable for retrofit 20 watt lamp B22 base including 20 watt LED lamp complete all as spd and directed. Make:- Havells MOON (PRISMATIC) Cat Ref LHFXBON1TN6F035 or equivalent in Orient / Phillips /CG.
S&F in replacement sheet metal enclosure MCB distribution board, double door with IP-43 protection single pole and neutral 240 volts, 8 way, including suitable size copper bus bar and neutral link, epoxy powder coated, factory made complete without MCB and with enclosure blank plates for unused way fixed flush in wall including chases wall for fixing DB and making good distributed wall surfaces complete all as specified and directed.
S&F in replacement sheet metal enclosure MCB distribution board, double door with IP-43 protection single pole and neutral 240 volts, 4 way, including suitable size copper bus bar and neutral link, epoxy powder coated, factory made complete without MCB and with enclosure blank plates for unused way fixed flush in wall including chases wall for fixing DB and making good distributed wall surfaces complete all as specified and directed.
S&F in replacement sheet metal enclosure MCB distribution board, double door with IP-43 protection single pole and neutral 240 volts, 12 way, including suitable size copper bus bar and neutral link, epoxy powder coated, factory made complete without MCB and with enclosure blank plates for unused way fixed flush in wall including chases wall for fixing DB and making good distributed wall surfaces complete all as specified and directed.
S&F in replacement sheet metal enclosure MCB distribution board, double door with IP-43 protection TPN 415 Volts, 4 way, including suitable size copper bus bar and metal door, epoxy powder coated, factory made complete without MCB and with enclosure blank plates for unused way fixed flush in wall including chases wall for fixing DB and making good distributed wall surfaces complete all as specified and directed.
S&F in replacement sheet metal enclosures distribution boards, double door three phase 415 volts 4 ways vertical TPN DB for comprising three phase four wire 200 Amp rated copper strip bus bar of appropriate capacity complete all as specified and directed and comprising of the following (a) MCCB four pole 100 Amps AC 415 Volts 25 KA - 01 No. as incoming (b) 12 Nos. MCB SP 40 Amps, C curve rupturing capacity 10 KA as outgoing Note :- (i) The DB shall be flush fixed and making good the disturbed surface matching with existing specifications. (ii) All connection of the MCCBs/ MCBs with cable shall be made through appropriate size pin /bottle type thimble -properly crimped. (iii) All vacant holes of the DB shall be provided with blank plates of appropriate size. (iv) Double continuous earth wire shall be provided for each three phase DB from earthing mains dolly (v) MCB's should have a same make as of DB.
S & F in replacement of MCB single pole 240 volts, 'C' curv of rating from 6 to 32 amps, with rupturing capacity 10 KA,including providing thimble for out going cables.
S & F in replacement MCB SPN 240 volts, 'C' curv of rating from 6 to 32 amps, with rupturing capacity 10 KA,including providing thimble for out going cables.
S&F in replacement MCB TPN 240 volts, 'C' curve of rating from 40 to 63 amps, with rupturing capacity 10 KA, including providing thimble for out going cables complete all as specified and directed.
Supply & laying in replacement rigid PVC conduit of 25mm dia with accessories ISI marked for connection complete all as specified and directed.
S&F in replacement MCCB 100 Amps 415 volts, 50 Hz, 4 pole 16 KA breaking capacity including providing thimbles for out going cable /sprade link for incoming cable with nut bolts complete all as specified and directed.
Supply & laying in replacement PVC insulated, copper conductor FR grade 2.5 sqmm 3 core cable ISI marked for connection complete all as specified and directed.
S&F in repair flexible wire three core, PVC insulated 2.5 Sqmm multi stranded copper conductor, 1100 V grade for making connections from pole to street/flood lights complete all as specified and directed.
Excavation in trenches in soft/loose soil not exc 1.5m wide and not exc. 1.5m depth for laying of cable and getting out in soft / losse soil complete all as specified and directed
Returning, filling in, trenches including spreading, levelling, watering and well ramming in layers not exc. 25cm in any type of soil complete all as specified and directed.
Removing surplus excavated material not exc. 50m and depositing where directed at a level not exc. 1.5m above the starting point complete all as specified and directed.
Material and labour for PCC (1:2:4) type B1 (using 20mm graded stone aggregates) as in foundations, filling and mass concrete for foundation of garden or gate light complete all as specified and directed.
S&F in repair sub main wiring with two single core PVC insulated (FRLS) unsheathed multistranded copper conductor of size 4 sqmm nominal cross sectional area and one run of 4 sqmm nominal cross sectional area PVC insulated (FRLS) unsheathed multistranded copper conductor green colour as continuous earth wire drawn in and including not less than 20 mm dia 'medium grade' PVC concealed conduits (ISI marked) and fittings including cutting chases to walls for laying conduit and making good the disturbed wall surfaces to match with existing specification complete all as specified and directed.
S&F in repair sub main wiring with two single core PVC insulated (FRLS) unsheathed multistranded copper conductor of size 6 sqmm nominal cross sectional area and one run of 6 sqmm nominal cross sectional area PVC insulated (FRLS) unsheathed multistranded copper conductor green colour as continuous earth wire drawn in and including not less than 20 mm dia 'medium grade' PVC concealed conduits (ISI marked) and fittings including cutting chases to walls for laying conduit and making good the disturbed wall surfaces to match with existing specification complete all as specified and directed.
M&L for earthing complete with galvanised steel plate electrode 600mm x 600mm x 6mm thick buried directly in ground (earth pit not less than 2.25 Mts deep below ground level with top edge of the plate not less than 1.50 Mtrs below ground level connected to glavanised iron Wire 4.0 mm dia by means of bolts, nuts check nuts and washers of galvanised iron or steel connected to earthing test point all as specified incl 15 mm GI tubing medium grade and necessary fitting for protection of GI wire incl laying of charcoal dust and common salt in alternate layer, PCC Pit (1:3:6) type C-1 using 20 mm graded stone aggregate, RCC cover 40mm thick (1:2:4) type B-0 using 12.5 mm graded stone aggregate reinforced with 6 mm dia round bar @ 75 mm C/C both ways with MS handle 8 mm dia, plastering 15 mm thick CM (1:6) externally upto 150mm below ground level , GI funnel with 20mm dia medium grade GI pipe for watering and wire mesh incl excavation and earth work and disposal of surplus soil complete all as specified and shown on electrical plate No 3 of SSR Part (2009) and connected to earth test point incl testing and marking Bldg Nos and writing Test Results on a 3.0 mm thick painted M.S. earth pit marking Plate (200mm x 100mm) duly welded with a 450 mm long 10 mm dia round M.S. rod, fixed with the earth pit chamber by grouting complete including taking out old unserviceable earthing system including demolishing old earth pit chambers and removing of debris from the site with levelling the ground all as specified an directed.
H.S.Kochhar n Sons
M/S VIDIT ENTERPRISES
S S TRADERS
Allied Builders
Mani Control System
C P Singh and Co
M/S R.S. CONTRACTOR & SUPPLIER
jmd engineers
stage.html
html • 0.07 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .