| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹35.2 LAccepted-AOC | L1 | Accepted-AOC Awarded being lowest bidder | |
| 2 | L2₹38.9 L+₹2.6 L (7.06%)Rejected-AOC | L2 | Rejected-AOC Rejected | |
| 3 | L3₹40.0 L+₹3.6 L (9.91%)Rejected-AOC | L3 | Rejected-AOC Rejected | |
| 4 | L4₹40.3 L+₹3.9 L (10.8%)Rejected-AOC PLOT NO 76 CIV SOCIETY MUKUND NAGAR AHMEDNAGAR 414001 | AHMEDNAGAR | AHMEDNAGAR | MAHARASHTRA | 414001 | L4 | Rejected-AOC Rejected | |
| 5 | L5₹40.6 L+₹4.2 L (11.6%)Rejected-AOC | L5 | Rejected-AOC Rejected |
Tender Value
₹46 L
EMD Value
₹92,000
Closing Date
20 Jun 2020, 6:00 pmClosed
Garrison Engineer North Ahmednagar
Military Engineer Services Garrison Engineer North Nagar-Pathardi Road Opp Ahmednagar Fort Ahmednagar-414002
Special Repairs to Building No P-114/01 to 10 ORs MD Accn (Vijay lines AC Records) ACCS and Special Repairs to sewage line to Bldg No P-108 and P-109 ORs MD (Vijay lines ASW) in the area of AGE B/R I under GE (N) Ahmednagar
2020_MES_343667_1
8424 / E8
Open Tender
Miscellaneous Works
Item Rate
180 days
Ahmednagar
Class D Cat a(i)
8 documents required · 8 mandatory
₹500
Yes
Garrsion Engineer North Ahmednagar
₹92,000
Yes
1 Jul 2020
12 May 2020
22 Jun 2020
12 May 2020
20 Jun 2020
13 Jun 2020
Amount
Demolition of cement concrete (unreinforced) in ground floor and paving n.exc 15cm in thickness (below or above ground level) etc complete all as specified and directed by Engineer-in-Charge
Dismantling of stone slabs and tiles of any description or thickness in floors, approns etc laid and bedded in any mortar etc complete all as specified and directed by Engineer-in-Charge
Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing), removing rubbish off the premises etc complete all as specified and directed by Engineer-in-Charge
Demolition of Stone/boulder masonry, built in cement mortar including all quoins, arches, pillars,etc, but excluding ashlar facings, dressed stone work and precast concrete articles etc complete all as specified and directed by Engineer-in-Charge
M&L for 75mm thick PCC (1:3:6) type D-2 using 40mm graded stone aggregate as in sub base etc complete all as specified and directed by Engineer-in-Charge
M&L for Ceramic coloured tiles 7 to 8 mm thick, area of tile exc 0.18 Sqm but not exc 0.38 Sqm as in floor, over and including 15 mm thick screed bedding in cement and sand mortar (1:6), set and jointed in neat cement slurry and pointed in coloured cement to match the shade of tiles etc complete all as specified and directed by Engineer-in-Charge
M&L for ceramic coloured tiles 7 to 8 mm thick, area of tile exc 0.18 Sqm but not exc 0.38 Sqm on vertical surfaces such as skirting / Dado, over and including 10 mm thick backing coat in cement and sand mortar (1:4), set and jointed in neat cement slurry and pointed in coloured cement to match the shade of tiles etc complete all as specified and directed by Engineer-in-Charge
M&L for non skid ceramic coloured tiles 7 to 8 mm thick (square/ rectengular) area of each tile exc 0.06 Sqm but not exc 0.11 Sqm as in floor of Kitchen / toilet / bathroom etc over and including 15 mm thick screed bedding in cement and sand mortar (1:6), set and jointed in neat cement slurry and pointed in coloured cement to match the shade of tiles etc complete all as specified and directed by Engineer-in-Charge
M&L for glazed ceramic coloured tiles of size 350 X 250 X 7 mm thick on vertical surfaces such as skirting /dado over and including 10 mm thick backing coat of cement and sand mortar (1:4) set and jointed in neat cement slurry and pointed in coloured cement to match the shade of tiles etc complete all as specified and directed by Engineer-in-Charge
Taking down cement plaster on brick / stone walls including raking out joints, hacking for key, scrubbing down with water etc complete all as specified and directed by Engineer-in-Charge
M&L for rendering, 15 mm thick on any type of face of stone masonry / brick work / concrete surfaces in cement and sand mortar (1:4) on wall surface finished even and smooth without using extra cement etc complete all as specified and directed by Engineer-in-Charge
M&L for rendering, 15 mm thick on any type of face of stone masonry / brick work / concrete surfaces in cement and sand mortar (1:6) on wall surface finished even and smooth without using extra cement with sagol finish all as sepecified and directed.
M&L for rendering, 10 mm thick on concrete surfaces in cement and sand mortar (1:4) on ceiling surface finished even and smooth without using extra cement with sagol finish etc complete all as specified and directed by Engineer-in-Charge
M&L for two coats of acrylic antifugal paint on newly / old plastered surfaces including preparation of surfaces on wall etc complete all as specified and directed by Engineer-in-Charge
M&L for applying two coats of oil bound distemper on newly plastered surfaces of walls including preparation of surfaces etc complete all as specified and directed by Engineer-in-Charge
M&L for complete removal of existing treatment and applying two coats of Oil Bound Distempar (OBD) on plastered surfaces of walls including preparation of surfaces etc complete all as specified and directed by Engineer-in-Charge
M&L for precast cement concrete block masonry with solid blocks,exc 10 cm in width and setting in cement and sand mortar (1:4) etc complete all as specified and directed by Engineer-in-Charge
M&L for applying 2 coats of white wash on newly/old plastered surfaces including preparation of surfaces, on wall etc complete all as specified and directed by Engineer-in-Charge
M&L for applying 2 coats of white wash on newly/old plastered surfaces including preparation of surfaces etc. complete as on ceiling etc complete all as specified and directed by Engineer-in-Charge
Material and labour for special treatment to sunken slab floor incl WC trap etc including cleaning and preparing the surface area for carrying out membrane water proofing treatment, then injection grouting the weak areas on the concrete surface with cementitious grout and applying 10mm thick cement plaster in cement and sand mortar (1:4). Then providing and laying Mineral Top APP (Atactic Polypropylene Polymer) modified prefabricated 5 layer 4mm thick water proofing membrane, black finished reinforced with non woven polyester matt consisting of a coat of bitumen primer for bitumen membrane @ 0.40 Litre per Sqm by the same membrane manufacturer of density at 25ºC, 0.87-0.89 Kg per litre and viscosity 70-160 cps. Over the primer coat the layer of membrane shall be laid using Butane Torach and sealing all joints etc and preparing the surface complete. and providing PCC (1:5:10) type E2 using 40mm graded mechanically crushed stone aggregates in sunken slab and 75mm thick PCC (1:4:8) type D2 using 40mm graded mechanically crushed stone aggregates as base, 40mm bore GI pipe, light grade of length not less that 50 cm as spout, including WC viterous china squatting pan 580x440mm with integral footrests/pedastal pan incl seat cover, white, area of WC exc 1.00 Sqm but nexc 5.00 sqm etc after dismantling the existing sunken floor etc complete all as specified and directed by Engineer-in-Charge
M&L for Shahabad stone 20mm to 25mm thick flooring screed bed or bedding layer of cement and sand mortar 15 mm thick finished to receive tiles and stone slab all as specified and directed.
M&L chequered cement concrete tiles 20cm x 20cm x 25mm thick, set, jointed and pointed in neat cement slurry with grey cement and no pigmentas as in flooring etc complete all as specified and directed by Engineer-in-Charge
M&L for kota stone slab 20-25mm thick as in riser of steps, skirting, dado and pillar laid over and including cement screed in cement and sand mortar (1:4) and jointed and pointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing etc complete all as specified and directed by Engineer-in-Charge
M&L for screed bed or bedding layer of mortar 10mm thick in cement and sand mortar (1:3) by using 100% course sand on roof/chajja mixed with & including WPC @ 3% by weight of cement and finished the surfaces even and smooth without using extra cement to receive water proofing treatment etc complete all as specified and directed by Engineer-in-Charge
M&L for providing waterproofing treatment on roof / chajja as per latest zonal specification, as per manufacturer's instructions and as specified after taking down / out as existing at site etc complete all as specified and directed by Engineer-in-Charge:- (a) M&L for cleaning the newly plastered surface with wire brushes and applying two coats of bituminous primer @ 0.25 ltrs / sqm and allow to dry. (b) M&L for applying and laying torch APP polymer midified bituminous membrane 3mm thick with non woven polyster matt as reinforced weighing not less 3 kg / Sqm with white gravel/mineral finished by thermofusion process.
S&F Mild steel TMT bars 6mm to 8mm dia, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips including cutting & removal of old decayed reinforcement etc complete all as specified and directed by Engineer-in-Charge
M&L for machine cut cudappa stone slab 20-25 mm thick laid over and including 15 mm thick screed bed in cement and sand mortar (1:6), set and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing etc compete all as specified and directed by Engineer-in-Charge.
M&L for granite(of any type) work (table rubbed and polished) cooking platform and like set in cement and sand mortar (1:4) including pointing in white cement and sand mortar (1:2) using marble dust with admixture of pigment to match with shade of granite thickness of granite 18 to 20mm complete all as specified and directed.
Rounding to edges of stone slabs one edge, such as in steps, cooking platform, and other similar situations etc complete all as specified and directed by Engineer-in-Charge
Taking down steel windows / ventilators, of any description and size etc complete all as specified and directed by Engineer-in-Charge
S&F Steel windows with side hung shutters including projecting type hinges with steel handle, and steel peg stay, complete with glazing bars, dovetailed or welded etc complete all as specified and directed by Engineer-in-Charge. Note: Wire cloth, glass and guard bars shall be measured and paid separately under appropriate item of this BOQ
S&F Steel ventilator with top hung shutter including hinges, steel peg stay, etc complete all as specified and directed by Engineer-in-Charge Note: Wire cloth, glass and guard bars shall be measured and paid separately under appropriate item of this BOQ
S&F mild steel 10 mm square bar to steel windows/ventilators as in guard bar conforming to Fe-290 Gde E-165 etc complete all as specified and directed by Engineer-in-Charge
Hacking out old broken glass (any thickness, size, quality or description) from metal frame including punching or drilling out old glazing pins/spring clips and providing and fixing new ones etc complete all as specified and directed by Engineer-in-Charge
M&L for glazing with 3 mm thick sheet glass ordinary quality and glazing with oil putty in square not exc 0.50 sqm in each pane etc complete all as specified and directed by Engineer-in-Charge
M&L for glazing with 3 mm thick figured glass, pin head type and glazing with oil putty in squares n exc 0.5 sq. m in each pane etc complete all as specified and directed by Engineer-in-Charge
S&Fstainless steel wire cloth 0.63 nominal dia of wire and average width of aperture 1.40 mm and fixed with stainless steel wire staples etc complete all as specified and directed by Engineer-in-Charge
All as per item No 37 (here-in-before) but fixed in repairs.
Taking down chowkhats or frames of size n' exc 1.5 Sqm each with shutters (without taking off shutters from the frame)
Taking down shutters of any description and size exc 1.0 Sqm but not exc 2.0 Sqm each etc complete all as specified and directed by Engineer-in-Charge
S&F 35 mm thick 2nd class hard wood factory made plain framed, panelled shutter (two panel) with lock rail and panel of 9 mm B.W.P. commercial plywood. The size of rail and stile as per IS : 1003 (Part I), kiln seasoned and chemically pressure treated etc complete all as specified and directed by Engineer-in-Charge
S&F 35 mm thick 2nd class hard wood glazed and skeleton shutters, open rebated and prepared to receive glass, gauze, etc. (without sash bars), edges of framing plain, chamfered or rounded. fitted with cut and mitred beads for securing glass, etc.; sizes of me-mbers of shutters as specified in SSR Part I, Section 8, clause 8.24 (a) etc complete all as specified and directed by Engineer-in-Charge
Solid PVC Door Frame of size 50mm x 47mm made out of 5mm plain colour PVC sheet reinforced with M.S. Square tube, suppling & fixing in opening as per specification & drawing etc complete all as specified and directed by Engineer-in-Charge
S&F factory made solid PVC door shutter 30 mm thick (style) consisting of frame made out of mild steel tubes for top and bottom rails frame shall be covered with heat moulded plain coloured PVC `C' channel having a PVC sheet strip of 20 mm width stuck and plain colour PVC sheets for top rail and bottom rail, panelling of plain colour PVC sheet to be fitted in the mild steel frame welded/sealed to the stiles and rails with suitable PVC sheet beading and jointed together with solvent cement, supplying and fixing in the frame etc complete all as specified and directed by Engineer-in-Charge
S&F 100 mm long butt hinge, medium weight, cold rolled mild steel etc complete all as specified and directed by Engineer-in-Charge
S&F 200 mm long mild steel barrel tower bolt, stove enamelled black, with bright bolt etc complete all as specified and directed by Engineer-in-Charge
S&F 150 mm long mild steel pressed handles, oval type, stove enamelled black etc complete all as specified and directed by Engineer-in-Charge
S&F 300 mm long mild steel sliding door bolts, plate type, stove enamelled black, with bright bolt not less than 12 mm dia with and including a minimum of 6 bolts and nuts, four on bolt plate and two on staple plate etc complete all as specified and directed by Engineer-in-Charge
S&F 200 mm long aluminium anodised barrel tower bolt, of extruded sections etc complete all as specified and directed by Engineer-in-Charge
S&F 150 mm long aluminium anodised handle, cast type etc complete all as specified and directed by Engineer-in-Charge
S&F 150 mm long floor door stopper of aluminium alloy body and tongue, anodised with hard drawn steel spring etc complete all as specified and directed by Engineer-in-Charge
M&L for preparation of new or previously untreated steel surface of any description not otherwise described over 10 cm width or girth and applying two coats of synthetic enamel paint over one coat of priming with red oxide etc complete all as specified and directed by Engineer-in-Charge
M&L for preparation of old painted steel surface of any description not otherwise described over 10 cm width or girth and applying one coat of synthetic enamel paint etc complete all as specified and directed by Engineer-in-Charge
M&L for preparation of new or proviously untreated wooden surface of any description not otherwise described over 10 cm width or girth and apply two coats of synthetic enamel paint over a coat of pink primer etc complete all as specified and directed by Engineer-in-Charge
All as per item No 53 (here-in-before) on old wooden surfaces
S&F Block board, 19/20mm thick, grade 1 quality, exterior grade, decorative type with decorative face veneer on one face, fixed with screws to timber frame work etc complete all as specified and directed by Engineer-in-Charge
M&L plain fillets, square, rectangular or triangular in section, wrought, secured with nails or brads, sectional area exc 3 & n.exc 6 Sq.cm of 2nd class hard wood etc complete all as specified and directed by Engineer-in-Charge
S&F continous (piano) hinges, mild steel, bright finish or electrogalvanised (width of flaps 30mm) etc complete all as specified and directed by Engineer-in-Charge
S&F 125mm hasp and staple, safety type, aluminium anodised with mild steel hinge pin including bolt to hinge plate and fixed with screws etc complete all as specified and directed by Engineer-in-Charge
S&F 125 mm long aluminium anodised handle, cast type etc complete all as specified and directed by Engineer-in-Charge
S&F in repair harrison rails, mild steel, chromium plated with fixing brackets, stops, rollers etc. etc complete all as specified and directed by Engineer-in-Charge
Dismantling of PVC water tanks of capacity n'exc 500/1000 ltrs and removing from site etc complete all as specified and directed by Engineer-in-Charge
Supply and fix in repairs rotational moulded polyethylene water storage tanks double layer ISI marked (cylindrical vertical with closed top) of 1000 litres capacity hoisted and fixed in position including 20 mm dia ball valve, high pressure of PTMT with epoxy coated aluminium rod and high density plastic ball screwed to irin pipe and connecting etc complete all as specified and directed by Engineer-in-Charge
S&F in repair gun metal globe or gate valve with iron wheel head, screwed both ends for iron pipe and fixed of 20mm bore fixed etc complete all as specified and directed by Engineer-in-Charge and as approved by GE.
S&F ball brass valves, high pressure, with polythene float and flynut complete, screwed for iron pipe or brass ferrule and fixed in 20mm dia bore pipe etc complete all as specified and directed by Engineer-in-Charge
Taking down 15 mm steel GI tubing including all connected fittings of any dia and in any position etc complete all as specified and directed by Engineer-in-Charge
All as per item No 66 (here-in-before) but 20mm dia pipe.
S&F 15 mm dia galvanised steel tubing medium grade including necessary fittings like sockets, tees, elbows, reducers, unions etc fixed to walls / ceiling etc complete all as specified and directed by Engineer-in-Charge
All as per item No 68 (here-in-before) but 20mm dia pipe.
Taking down eaves gutters and rainwater pipes (any size or pattern) including all fittings, heads, shoes, bends, swan-necks etc. (measured overalll as fixed along the centre line over fittings and accessories) etc complete all as specified and directed by Engineer-in-Charge
S&F 110 mm dia PVC SWR pipe, single socketed in any length with rubber ring joints fixed with clamps to walls etc complete all as specified and directed by Engineer-in-Charge
S&F 75 mm dia PVC SWR pipe, single socketed in any length with rubber ring joints fixed with clamps to walls etc complete all as specified and directed by Engineer-in-Charge
S&F 110 mm dia PVC (SWR) vent cowl etc complete all as specified and directed by Engineer-in-Charge
S&F 110 mm bore PVC (SWR) branch piece double (single Y) equal or unequal etc complete all as specified and directed by Engineer-in-Charge
S&F 110 mm dia PVC (SWR) bend any radius etc complete all as specified and directed by Engineer-in-Charge
S&F 75 mm dia PVC (SWR) bend with access door any radius etc complete all as specified and directed by Engineer-in-Charge
S&F PVC (SWR) floor trap, 75 mm dia with grating including jointing with solvent cement etc complete all as specified and directed by Engineer-in-Charge
S&F in repair chromium plated grating 100mm dia etc complete all as specified and directed by Engineer-in-Charge
Supply and fix in repair bib tap, 15 mm dia, CP cast copper alloy with crutch or butterfly handle screwed down for iron pipe or for brass ferrule etc complete all as specified and directed by Engineer-in-Charge. Make:- Cat part No MOR 1020 A (Orintal series) of MARC or equivalent in PLUMBER / ESS-ESS / Jaquar
Supply and fixing in repairs stop valve cast copper alloy, fancy type screwed down, high pressure with crutch or butterfly handle screwed both ends for iron pipe or for union and fix of size 15 mm bore etc complete all as specified and directed by Engineer-in-Charge Make:- Cat part No MOR 1320(Orintal series) of MARC or equivalent in PLUMBER / ESS-ESS / Jaquar
Supply and fix in repairs, shower rose with shower arm etc complete all as specified and directed by Engineer-in-Charge Make:- Cat part No MARC MSR1050 (Shower) and MOR 1260 (Shower arm) of MARC or equivalent in Make Plumber / ESS-ESS / Jaquar
S&F PVC connections 15 mm size with PTMT nuts of length 450 mm etc complete all as specified and directed by Engineer-in-Charge
Supply and fix tubular towel rail, brass chromium plated 20 mm dia `D' type, 60 cm long between flanges including a pair of brackets all as directed. Make:- Cat part No UO911 of PLUMBER or equivalent in MARC, ESS-ESS
Supply and fix in repairs looking mirror of size 600 mm X450 mm all as directed. Make:- Cat part No C 8606 Of Parryware or equivalent in Jaquar / Cera / Hindware
S&F in repairs 32 mm dia low density polyethylene pipes (HDPE) of pressure rating 6 kgf/cm2 fixed complete to walls, ceilings or in floors etc complete all as specified and directed by Engineer-in-Charge
Supply and fix in repairs PVC valveless, syphonic action type, flushing cistern,low level wtih all accesories etc complete all as specified and directed by Engineer-in-Charge. Make :- Sleek essence series Of Hindware or Cat part No E8303 of Parryware or equivalent in Cera / Jaquar
Supply and fix in repairs vitreous China white squatting pan, Orissa pattern of size 580 X 440 mm width with integral foot rest set in cement concrete including flush pipe and connecting to trap / flushing cistren etc complete all as specified and directed by Engineer-in-Charge. Make :- Cat Part No C0117 Of Parryware or Cat Part No 20042 of Hindware or equivalent in Cera / Jaquar
Supply and fix in repairs wash hand basin vitreous China white, flat back type of size 550 X 400 mm pedastal type including pedastal, pillar tap, CP waste chain and plug and porcelain stopper, waste pipe, a pair of brackets,or errecting stand and PVC connection etc complete all as specified and directed by Engineer-in-Charge Make :- Cat Part No 10098 of Hindware or equivalent in Parryware / Cera / Jaquar
Supply and fix in repair 15 mm dia pillar tap, cast copper alloy, with capstan heads, chromium plated, fancy type, screwed down high pressure, with or without lettered 'Hot' or 'Cold' with long screwed shanks and fly-nuts, screwed for iron pipe etc complete all as specified and directed by Engineer-in-Charge. Make:- Cat part No MOR 1010(Orintal series) of MARC or equivalent in PLUMBER / ESS-ESS
Supply and fixing stainless steel kitchen plate rack made out of 0.63 mm thick stainless steel sheet of size 750x900mm including screws etc complete all as specified and directed by Engineer-in-Charge.
S&F expanded metal, weld mesh jali n.exc 4kg/sqm cut to length, bent to shape required and tying with and including annealed mild steel wire not less than 0.9 mm dia or fixing with galvanixed steel staples supplied and fixed complete to wood or steel members etc complete all as specified and directed by Engineer-in-Charge
M&L for taking down and refixing in same opening shutters of any description of size exc 1.0 Sqm but not exc 2.0 Sqm Each etc complete all as specified and directed by Engineer-in-Charge
Excavation in trenches not exc 1.5m wide and not exc 1.5m in depth for foundation etc or for walls, shafts, manholes, laying of cable, pipe, not exc 10 Sqm on plan and getting out, in soft/loose soil etc complete all as specified and directed by Engineer-in-Charge
Excavation in trenches exc 1.5m wide and not exc 3m in depth for foundation etc or for walls, shafts, manholes not exc 10 Sqm on plan and getting out, in soft/loose soil etc complete all as specified and directed by Engineer-in-Charge
Demolition of cement concrete (un-reinforced), of any description, in any position, from the foundation of manhole including benching etc complete all as specified and directed by Engineer-in-Charge
Demolition of reinforced cement concrete of any description and in any position not otherwise provided for including reinforced cut as required to facilitate demolition etc complete all as specified and directed by Engineer-in-Charge
Demolition and breaking up 150 mm bore drain pipe i.e. salt glazed ware, AC or reinforced concrete pipe , set in cement mortar etc complete all as specified and directed by Engineer-in-Charge
All as per item No 97 (here-in-before) but 200mm bore pipe
Returning filling in including spreading leveling watering and well ramming in layers not exc 25 cm thick each etc complete all as specified and directed by Engineer-in-Charge
Removing excavated materials to a distance not exc 50m and depositing where directed at a level not exc 1.5 m above the starting point in soils etc complete all as specified and directed by Engineer-in-Charge
Material & labour for 150 mm bore Reinforced cement concrete pipe, type NP2 , haunching against the sides of pipe in PCC (1:4:8) type D-2 using 40mm graded mechanically crushed stone aggregates and making necessary connection after cutting into existing sewer line/manhole to make it functional etc complete all as specified and directed by Engineer-in-Charge for the following :- . Note :- (i) Cutting into existing sewer line/manhole shall be measured & paid seperately under appropriate item of this BOQ (ii) Earth work shall be measured and paid separetely once either while demolition or white laying SGSW pipe under appropriate item of this BOQ
Material & labour for 200 mm bore Reinforced cement concrete pipe, type NP2 , haunching against the sides of pipe in PCC (1:4:8) type D-2 using 40mm graded mechanically crushed stone aggregates and making necessary connection after cutting into existing sewer line/manhole to make it functional etc complete all as specified and directed by Engineer-in-Charge Note :- (i) Cutting into existing sewer line/manhole shall be measured & paid seperately under appropriate item of this BOQ (ii) Earth work shall be measured and paid separetely once either while demolition or white laying SGSW pipe under appropriate item of this BOQ
Material and labour for reinforced cement concrete (1:2:4) type B-1 using 20mm graded mechanically crushed stone aggregates as in cover slab for drain or manhole including necessary form work set and jointed in cement and sand mortar (1:6) etc complete all as specified and directed by Engineer-in-Charge
M&L for PCC (1:3:6) type C-1 using 20mm graded mechanically crushed stone aggregates as in cills, steps, bands, copings, bed plates, kerbs, hold fasts blocks etc including weathering slightly rounded or chamfered angles of throating including form work etc complete all as specified and directed by Engineer-in-Charge
M&L for PCC (1:3:6) type C-1 using 20 mm graded mechanically crushed stone aggregates as in surface channel & drain etc complete all as specified and directed by Engineer-in-Charge
M&L for PCC (1:4:8) type D2 using 40mm graded mechanically crushed stone aggregates as in foundation, filling and mass concrete or similar works etc complete all as specified and directed by Engineer-in-Charge
Material and labour brick work with fly ash straight or curved on plan exc 6m mean radius, built in built in cement and sand mortar (1:6) etc complete all as specified and directed by Engineer-in-Charge
Material & Labour for rendering 10 mm thick in cement and sand mortar (1:4) on concrete surfaces of wall finished even & smooth without using extra cement mixed with water proof compound @ 3% of the weight of cement as per the manufecturer's instructions etc complete all as specified and directed by Engineer-in-Charge Note :- WPC shall be measured and paid separetely under appropriate item of this BOQ
Supply only integral water proofing compound etc complete all as specified and directed by Engineer-in-Charge
Supply and fix mild steel deformed bars or TMT bars, 8 mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with mild steel wire (annealed) not less than 0.9 mm dia etc complete all as specified and directed by Engineer-in-Charge
Cutting into existing manholes for connecting new drains 200mm internal dia of pipe making good to pipe abd rendering, cutting out existing benching for and forming branch channel (1/2 round or 3/4 section) in cement concrete (1:2:4) type B-1 smooh finished and reforming benching as required etc complete all as specified and directed by Engineer-in-Charge
Cutting into existing manholes for connecting new drains 150mm internal dia of pipe making good to pipe abd rendering, cutting out existing benching for and forming branch channel (1/2 round or 3/4 section) in cement concrete 1:2:4 type B-1 smooh finished and reforming benching as required etc complete all as specified and directed by Engineer-in-Charge
M&L for Machine pressed precast concrete interlocking paver block any shape and size confirming to IS 15658-2006 of 60 mm thickness, M-35 Grade as including 30 mm thick low grade and cushining etc complete all as specified and directed by Engineer-in-Charge
M&L for Surface dressing n. exc 15 cm deep and removal of wild groth / shurps, roots, incl spraying of deweding chemical 1 m each side on both sides along sewage line etc complete all as specified and directed by Engineer-in-Charge
Taking down/out the cover from septic tank / soakage well and dewatering the contaminated / waste material from septic tank/soak well/sump well of any depth/capacity by means of using mechanical pumps diesel driven with fuel or by operator sewage sucking machine or by way of any other suitable means including desludging foreign material, sand, ashes, fibre, silt, grease, night soil, etc and removing the taken out sludge mixed material/liquid out side MD land by any means/source and refixing the covers back to its original position etc complete all as specified and directed by Engineer-in-Charge Note :- For payment purpose volume of sludge will be measured and paid only
Supplying and fixing precast manhole cover (LD) of size 12" x 12" made up of steel fiber reinforced concrete M-30 grade as per IS etc etc complete all as specified and directed by Engineer-in-Charge
All as per item No 116 (here-in-before) but size 18" x 18"
All as per item No 116 (here-in-before) but size 18" x 36"
M&L for cleaning blockage of manholes circular size 1.5 mtr dia (inner) and square size 1200 x 900mm , depth exc 1.5 m n exc 3.0m, including getting out snd removal of undissolved materials, debries, sewage sludge, plastic, thermocoal, gunney bags, etc accumulated at sewage line using sewage non clog pumps of sutable rating and removing the taken out material out side the MD land etc complete all as specified and
All as per item No 119 (here-in-before) but depth exc 3.00 m & n.exc 6 m
Formwork to soffits of suspended slabs such as roof slab, floor slab, landings and similar work not exceeding 200 mm thick etc complete all as specified and directed by Engineer-in-Charge
S&F in repair sinks made of stainless steel 1.0 mm thick kitchen or laboratory with plugs, washers and wastes; including bedding in cement and sand mortar (1:3) on to dwarf wall or including fixing cantilever brackets and connecting union to pipe, overall size 495mm x 420mm bowl size 410mm x 330mm x 160mm etc complete all as specified and directed by Engineer-in-Charge
M&L for applying 3 mm thick wall care putty on wall (One layer) etc complete all as specified and directed by Engineer-in-Charge
Taking down carefully aluminium point wiring (light, fan, bell, socket, power point etc.) with or without conduit, casing caping, along with all connected accessories such as ceiling rose, switches, sockets, switch boards, fan regulator etc complete and all as directed by EIC
M & L for point wiring complete with 1.5 Sqmm single core, multistranded copper conductor of 1100 volts grade PVC insulated and unsheathed FRLS cable drawn through and including PVC Casing & Caping with necessary accessories with and provision of pressed steel terminal box powder coated of suitable size with and including 3 mm thick plastic laminated sheet top cover fixed by using CP machine screw, cup washer for housing of switch / fan regulator etc. with and including 1.5 Sqmm single core multistranded copper conductor FRLS 1100 volts grade PVC insulated and unsheathed cable as earth continuity conductor to common earth & connecting to earth dolly etc complete all as specified and directed by Engineer-in-Chargefor the following :-
(a) One light point controlled by one, one way switch single pole.
(b) One Fan point controlled by one, one way switch single pole.
(c) One 3 pin 5 Amp socket out let on independent board
(d) One 3 pin 5 Amp socket out let on Sameboard
(e) One bell point controlled by one bell push on independent board.
(f) One light point controlled by one, two way switch single pole.
All as per item No 125 (here-in-before) but with 2.5 Sqmm Copper conductor cable for phase, neutral & earth for one 3 pin, 15 Amps socket out let on independent board
S&F switch piano flush type 230/250 Volt, 5 Amps single pole one way etc complete all as specified and directed by Engineer-in-Charge
All as per above item No 133 but two way switch etc complete all as specified and directed by Engineer-in-Charge
S & F bell push, switch flush type, 5 Amp etc complete all as specified and directed by Engineer-in-Charge
S & F bell, AC, 230 Volts, single pole etc complete all as specified and directed by Engineer-in-Charge
S& F stepped type electronic fan Regulator flush type on the existing phenolic laminated etc. as reqd single pole 240 volts grade 100 watts heavy duty ISI marked etc complete all as specified and directed by Engineer-in-Charge
S&F switch socket combination multi purpose 2 in 1, 6 pin 5 Amp, flush type, ISI marked etc complete all as specified and directed by Engineer-in-Charge
S&F switch socket combination 5 in 1 ,5Amp/15 Amp, flush type, ISI marked etc complete all as specified and directed by Engineer-in-Charge
S&F ceiling rose surface bakelite 65mm x 50mm three terminal etc complete all as specified and directed by Engineer-in-Charge
S&F Lamp holder, PVC/Polycarbonate type with cord grip cap suitable for pendant fittings etc complete all as specified and directed by Engineer-in-Charge
S & F in replacement double door Sheet metal enclosures factory made DBs 8 way SPN ,240 volts ,protection class IP-42, suitable for fixing of MCBs, Isolators etc, confirming As per IEC 61439-3 ,Suitable for Flush Mounting and Surface Mounting, With 100 A Copper Busbar ,With Neutral bar, Earthbar and Cable ties for Cable management,Fully shrouded Neutral bars, Prefitted masking sheet etc complete all as specified and directed by Engineer-in-ChargeMake: Legrand ,Cat No: 5076 11 or equivalent in Simens/ Hager
S & F in replacement double door Sheet metal enclosures factory made DBs 4 way, TPN , 415 volts ,protection class IP-42, suitable for fixing of MCBs, Isolators etc, confirming As per IEC 61439-3 ,Suitable for Flush Mounting and Surface Mounting, With 100 A Copper Busbar ,With Neutral bar, Earthbar and Cable ties for Cable management,Fully shrouded Neutral bars, Prefitted masking sheet complete all as specified and as directed. Make: Legrand ,Cat No:5076 70 or equivalent in Simens/ Hager/L& T
S&F isolators of the under mentioned type and rating and fixing in DBs (DBs measured and paid for separately) (Note :- Make of the isolator should be the same as that of DB) for the following :-
MCB Single Pole of 240 volts 5-32 Amps,10 KA Capacity, etc complete all as specified and directed by Engineer-in-Charge
MCB Single pole + Neutral 240 volts, 32 -63 Amps,10 KA Capacity etc complete all as specified and directed by Engineer-in-Charge
MCB Triple pole + Neutral 415 Volts ,40 -63 Amps,10 KA Capacity etc complete all as specified and directed by Engineer-in-Charge
Taking down Existing tube light fitting & Supply & fix LED tube light along with fixture,20 W etc complete all as specified and directed by Engineer-in-Charge
Taking out old building security light ( HPSV/Tube light fitting) & Supply and fix LED bldg security light 25 W IP 65 etc complete all as specified and directed by Engineer-in-Charge
M&L for earthing complete with galvanised steel earth plate electrode 60cmx60cm x 6 mm thick buried directly in ground vertically to depth not less than 2.25 mtr below ground level with top edge of earth plate at a depth not less than 1.5 mtr below ground level connected to and including GI wire 4mm as earth lead up to 7.5 mtr length by means of bolts, nuts check muts and washers etc. of galvanised iron or steel all as shown in electrical plate No. 3 including provn of GI protection pipe light grade of 32mm bore upto 7.5m length and connected earth strip to earthing test point all as shown in electrical plate No. 3 of SSR Part - I 2009 and as specified or indicated and testing on completion including necessary excavation & earthwork in any type of soil, PCC (1:3:6) type C1 chamber, precast slab 50mm thick in cement concrete (1:2:4)type B1 (rein forced with welded steel wire fabric (XPM) of weight not less than 4kg/sqm) with frame, funnel with watering pipe of 20mm bore medium grade, wire mesh and lugs test point etc.
M&L for sub main wiring with two runs of PVC insulated and unsheathed FRLS cable 650/1100 Volts grade, conforming to IS-1536-1977 multi-stranded 4 Sqmm single core, copper conductor drawn through existing conduit and 4 Sqmm single core multistranded copper conductor FRLS PVC insulated and unsheathed cable 1100 volts grade, ISI marked as earth continuity wire complete all as specified and directed (Note : Two runs of conductor with one run of earth wire and PVC casing capping will be measured & paid as one unit)
Supply and fix in replacement industrial type switch socket for Geysers with 20 Amps MCB etc complete all as specified and directed by Engineer-in-Charge
M & L for Supply,laying ,connecting ,testing and commissioning and jointing , LT underground cable in replacement 10 Sqmm, 4 core, 1100 volts grade, XLPE insulated, armored with galvanized round steel wire or steel strip, electric power cables heavy duty, with multi stranded aluminum conductor, laid in ducts, fixed on poles/walls with proper size saddles and clamp complete all as specified and as directed by the Engineer-in-Charge of following Sizes :-
M&L for sand cushioning for UG cables using dry river sand; gently punning down all as directed and specified. ( Note : For measurement purpose punned thickness shall be considered)
M&L un-reinforced pre cast concrete cable covers CLASS LV type 2, flat size 300mm x 180mm x 40 mm to be laid transverse to cable
M&L for sub class `B' burnt clay bricks for cable protection etc complete all as specified and directed by Engineer-in-Charge.
An amount of Rs 1,02,294.75 shall be deducted from BOQ on account of schedule of credit
OM SAI ASSOCIATES
Ms. M.D. Auty
HG PATHAN CONSTRUCTION COMPANY
M/s.Abhay Kulkarni and Associates
M/s. Sagar Traders
Priyadeep Construction
MS. G.A. CONSTRUCTION
MS. A.S. CONSTRUCTION
Manak landmarks
M/s AG PATHAN
stage.html
html • 0.07 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .