| 1 | L-1₹15.8 LAccepted-AOC | L-1 | Accepted-AOC Being the lowest bidder | |
| 2 | L-2₹18.9 L+₹2.2 L (13.5%)Rejected-AOC B XXIII 56 A PREM NAGAR SAINGARGH PATHANKOT 145001 PUNJAB | PATHANKOT | PATHANKOT | PUNJAB | 145001 | L-2 | Rejected-AOC Not being the lowest bidder |
Tender Value
Refer Docs
EMD Value
₹33,000
Closing Date
31 Dec 2020, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
LT COL SANGRAM SINGH
GE Kaluchak Pin-900673 C/o 56 APO
REPAIR REPLACEMENT OF EM SECURITY INFRA AND STANDBY POWER SUPPLY EQUIPMENTS AT KALUCHAK MIL STN UNDER GE KALUCHAK
2020_MES_389206_2
GE/KC/NIT-53/2020-21
Open Tender
Electrical and Maintenance Works
Item Rate
270 days
Kaluchak
Please refer Tender documents.
9 documents required · 9 mandatory
₹500
GE Kaluchak
₹33,000
Yes
23 Jan 2021
11 Dec 2020
2 Jan 2021
11 Dec 2020
31 Dec 2020
19 Dec 2020
11 Dec 2020 - 18 Dec 2020
60 days
Amount
Servicing of DG Set 62.5/ 63 KVA of any Make, checking entire system as per manufacturers catalogue such as checking all parts for serviceablity, taking down defective parts such as fuel filter assy, by pass filter assembly, lub oil filter assembly, air cleaner assy, flexible hose pipe, coolent etc and replacing the same with same size, make and capacity of parts, draining out the old used burnt engine oil from the sump cleaning all serviceable filters and oil sump with cleaning solution such as petrol/ diesel and refilling new engine oil upto required level including testing of DG Set to the entire satisfaction of Engr-in Charge. Make : Kirloskar/ Ruston Notes:- (i) Spare parts/ Engine oil/ Check kit/ filter shall be measured and paid for saperately under respective items of BOQ as 'Supply only'. (ii) Minimum 6 months gap/ 500 Hrs of run whichever is earlier shall be considered for next service. (iii) Repair guarantee for replaced parts/ servicing of DG Set shall be for six month/ 500 Hrs run from the date of service whichever is earlier.
All as per Srl item No.01 above but DG set of capacity 45 KVA.
All as per Srl item No.01 here-in-before but DG set of capacity 40 KVA.
All as per Srl item No.01 here-in-before but DG set of capacity 30 KVA.
All as per Srl item No.01 here-in-before but DG set of capacity 25 KVA.
All as per Srl item No.01 here-in-before but DG set of capacity 20 KVA.
All as per Srl item No.01 here-in-before but DG set of capacity 15 KVA.
Supply only lubricant oil filter suitable for 62.5/ 63 KVA DG set.
Supply only lubricant oil filter suitable for 45 KVA DG set.
Supply only lubricant oil filter suitable for 40 KVA DG set.
Supply only lubricant oil filter suitable for 30 KVA DG set.
Supply only lubricant oil filter suitable for 25 KVA DG set.
Supply only lubricant oil filter suitable for 20 KVA DG set.
Supply only lubricant oil filter suitable for 15 KVA DG set.
Supply only fuel filter with set of 'O' Ring for 62.5/ 63 KVA DG set.
Supply only fuel filter with set of 'O' Ring for 45 KVA DG set.
Supply only fuel filter with set of 'O' Ring for 40 KVA DG set.
Supply only fuel filter with set of 'O' Ring for 30 KVA DG set.
Supply only fuel filter with set of 'O' Ring for 25 KVA DG set.
Supply only fuel filter with set of 'O' Ring for 20 KVA DG set.
Supply only fuel filter with set of 'O' Ring for 15 KVA DG set.
Supply only air filter inner & outer suitable for 62.5/ 63 KVA DG set
Supply only air filter inner & outer suitable for 45 KVA DG set
Supply only air filter inner & outer suitable for 40 KVA DG set
Supply only air filter inner & outer suitable for 30 KVA DG set
Supply only air filter inner & outer suitable for 25 KVA DG set
Supply only air filter inner & outer suitable for 20 KVA DG set
Supply only air filter inner & outer suitable for 15 KVA DG set
Supply only engine oil 15W/ 40, complete all as specified & directed. Make: Kirloskar/ Castrol/ HP
Supply only coolent, complete all as specified & directed. Make: Servo/ Shell/ Castrol/ HP
Supply only distilled water for filling in batteries, complete all as specified & directed.
Supply only V belt suitable for 62.5/63 KVA DG set, complete all as specified & directed.
Supply only V belt suitable for 45 KVA DG set, complete all as specified & directed.
Supply only V belt suitable for 40 KVA DG set, complete all as specified & directed.
Supply only V belt suitable for 30 KVA DG set, complete all as specified & directed.
Supply only V belt suitable for 25 KVA DG set, complete all as specified & directed.
Supply only V belt suitable for 20 KVA DG set, complete all as specified & directed.
Supply only V belt suitable for 15 KVA DG set, complete all as specified & directed.
Supply, installation, testing and commissioning of lead acid battery, 12V, 105 AH conforming to IS:7372 including dismantling of old unserviceable battery, complete all as specified & directed. Make : Exide / Amaron/ Standard/ Furkkava
Supply, installation, testing and commissioning of lead acid battery, 12V, 90 AH conforming to IS:7372 including dismantling of old unserviceable battery, complete all as specified & directed. Make : Exide / Amaron/ Standard/ Furkkava
Steel flexible fuel pipe, superior quality, of 10mm dia approximate length 2 RM, tightening the same with two nos of jublee clips on both ends including taking down old unserviceable fuel pipe,complete all as specified & directed.
On load change over switch in sheet metal enclosure, 63 Amps, 415 volts, 4 pole, modular type, positive isolation, door interlock & padlock facility, conforming to IS:13947 (Part-3); IEC:60947-3 including all connecting/ jointing materials & taking down old unserviceable change over switch, complete all specified & directed. Make. C&S Electric Cat Part No.E-CSCS63NM4CO (NM Series) or equivalent model of make specified in List of Makes/ Manufacturers/ Producers here-in-after.
On load change over switch in sheet metal enclosure, 100 Amps, 415 volts, 4 pole, modular type, positive isolation, door interlock & padlock facility, conforming to IS:13947 (Part-3); IEC:60947-3 including all connecting/ jointing materials & taking down old unserviceable change over switch, complete all specified & directed. Make. C&S Electric Cat Part No.E-CSCS100NM4CO (NM Series) or equivalent model of make specified in List of Makes/ Manufacturers/ Producers here-in-after.
On load change over switch in sheet metal enclosure, 160 Amps, 415 volts, 4 pole, modular type, positive isolation, door interlock & padlock facility, conforming to IS:13947 (Part-3); IEC:60947-3 including all connecting/ jointing materials & taking down old unserviceable change over switch, complete all specified & directed. Make. C&S Electric Cat Part No.E-CSCS160NM4CO (NM Series) or equivalent model of make specified in List of Makes/ Manufacturers/ Producers here-in-after.
MCCB of capacity 200 Amps, 4 pole, 415volt, 50Hz, rupturing capacity 25 KA (minimum) or higher, thermal magnetic release, adjustable overload 80-100%, fixed short circuit in confirming to IS/IEC 60947-2 including taking down old unserviceable MCCB, complete all as specified & directed. Make. C&S Electric Cat Part No.CSE2M250ATM4P200 or equivalent model of make specified in List of Makes/ Manufacturers/ Producers here-in-after.
MCCB of capacity 160 Amps, 4 pole, 415volt, 50Hz, rupturing capacity 25 KA (minimum) or higher, thermal magnetic release, adjustable overload 80-100%, fixed short circuit in confirming to IS/IEC 60947-2 including taking down old unserviceable MCCB, complete all as specified & directed. Make. C&S Electric Cat Part No.CSE2M250ATM4P160 or equivalent model of make specified in List of Makes/ Manufacturers/ Producers here-in-after.
MCCB of capacity 100 Amps, 4 pole, 415volt, 50Hz, rupturing capacity 25 KA (minimum) or higher, thermal magnetic release, adjustable overload 80-100%, fixed short circuit in confirming to IS/IEC 60947-2 including taking down old unserviceable MCCB, complete all as specified & directed. Make. C&S Electric Cat Part No.CSE2M125ATM4P100 or equivalent model of make specified in List of Makes/ Manufacturers/ Producers here-in-after.
MCCB of capacity 63 Amps, 4 pole, 415volt, 50Hz, rupturing capacity 25 KA (minimum) or higher, thermal magnetic release, adjustable overload 80-100%, fixed short circuit in confirming to IS/IEC 60947-2 including taking down old unserviceable MCCB, complete all as specified & directed. Make. C&S Electric Cat Part No.CSE2M125ATM4P63 or equivalent model of make specified in List of Makes/ Manufacturers/ Producers here-in-after.
Intergral LED security light luminaire 60W LED, 230 volts made up of pressure die-cast aluminium housing with toughned glass and high power LEDs and secondry lenses with IP66 protection, efficacy not less than 110 lumens per watt including 10 KV surge protection device, mounted on GI bracket fixed on PCC/Steel pole, making connection with PVC copper conductor cable of 1.5 sqmm and taking down old unserviceable light fitting, complete all as specified & directed. Make. Crompton Greaves : Cat Part No. LSTP-60-CDL-M or equivalent model of make specified in List of Makes/ Manufacturers/ Producers here-in-after.
Intergral LED security light luminaire 90W LED, 230 volts made up of pressure die-cast aluminium housing with toughned glass and high power LEDs and secondry lenses with IP66 protection, efficacy not less than 110 lumens per watt including 10 KV surge protection device, mounted on GI bracket fixed on PCC/Steel pole, making connection with PVC copper conductor cable of 1.5 sqmm and taking down old unserviceable light fitting, complete all as specified & directed. Make. Crompton Greaves : Cat Part No. LSTP-90-CDL-M or equivalent model of make specified in List of Makes/ Manufacturers/ Producers here-in-after.
Integral LED security FLOOD light luminaire 120W LED 230 volts made of pressure die-cast aluminium housing with high power LED’s lens & toughned glass, IP-66 mounted on bracket/ fixed on PCC/ steel pole/ Sentry post with 02 Nos. clamps of flat iron (40 x 6mm), nuts, bolts and washers including painting with two coats of aluminium paint over a coat of red oxide zinc chrome primer, making connection with PVC copper conductor cable of 1.5 sqmm and taking down old unserviceable flood light fitting, complete all as specified & directed. Make. Crompton Greaves : Cat Part No. LFLN-120-CDL/60-M or equivalent model of make specified in List of Makes/ Manufacturers/ Producers here-in-after.
Excavation in trenches not exceeding 1.5 mtr wide and not exceeding 1.5 mtr in depth and getting out in any type of soil for foundation of pole, stay, taking up or laying of cable etc, complete all as specified & directed. Note : Due care shall be taken while deciding cable route for excavation. However any damage to Signal, BSNL, MES cable water/sewage pipe or any other service while excavation will be made good by the contractor and cost of the same for jointing material & labour is deemed to be included in the cost of excavation.
Excavation in trenches n.exc 1.5 mtr wide exc 1.5 mtr in deep but not exceeding 3.0 mtr deep and getting out for foundation of poles etc. in any type of soil, complete all as specified & directed. Note : Due care shall be taken while deciding cable route for excavation. However any damage to Signal, BSNL, MES cable water/sewage pipe or any other service while excavation will be made good by the contractor and cost of the same for jointing material & labour is deemed to be included the cost of excavation.
Returning, filling in (soil), including spreading, leveling, watering and well ramming in layers not exc. 25cm, complete all as specifed & directed.
Removing excavated material to a distance not exc. 50m and depositing where directed at a level not exc. 1.5m above the starting point, complete all as specified & directed.
Sand cushioning to under ground cable, laid in trenches 8cm thick below the cable and 15cm thick above the cable after laying and stretching the cable complete punned to 18cm, complete all as specified and directed. Note:- Punned thickness of sand will be measured and paid.
Brick well burnt locally available sub class 'B' laid over sand cushioning for mechanical cable protection in trenches with width of brick perpendicular to the length of cable, complete all as specified & directed.
PCC 1:4:8 type D-2 using 40mm graded crushed stone aggregate as in foundation of poles etc including necessary form work, complete all as specified & directed.
PCC 1:2:4 type B1 using 20mm graded crushed stone aggregate as in coping of pole etc including necessary form work, complete all as specified & directed.
PVC insulated weather proof twin core 2.50 sqmm (nominal area) aluminium conductor cable, 1100 volts grade, drawn in & including PVC conduit of suitable size with clamps (3 Nos), nuts, bolts etc from junction box to street light connection, complete all as specified & directed.
XLPE insulated, armoured heavy duty electric cable (heavy duty) with aluminium conductor, 1100 volts grade, cross-sectional area 25 Sqmm 3.5 core connected with suitable cable gland and aluminium lugs, laid in trenches or passing through pipes including testing after completion, complete all as specified and directed. (Earth work, brick protection and sand cushioning shall be measured and paid for separately)
Street light bracket made out of 40mm bore medium grade pipe of 1.50m length, bent to required shape, fixed on PCC/Steel pole with 02 Nos. clamps of flat iron (40 x 6mm), nuts, bolts and washers including painting with two coats of aluminium paint over a coat of red oxide zinc chrome primer and taking down old unserviceable bracket, complete all as specified & directed.
Galvanised iron tube 40mm bore light grade (ISI marked) for cable protection to poles/ under floor/ under roads/ alongwith walls complete including MS clamps of flat iron 25x3mm duly painted, GI nuts, bolts and washers & sealing of pipe ends with approved sealing compound, complete all as specified & directed.
Galvanised iron tube 25mm bore light grade (ISI marked) for cable protection to poles/ under floor/ under roads/ alongwith walls complete including MS clamps of flat iron 25x3mm duly painted, GI nuts, bolts and washers & sealing of pipe ends with approved sealing compound, complete all as specified & directed.
Pole mounted distribution box powder coated for street light made of CRCA sheet of 3mm thick, dust and vermin proof, outdoor type of size 300mm x 260mm x 165mm with arrangement of incoming and outgoing feeder comprising of TPN aluminium bus bar of capacity 32 Amp 415 volts, single MCB SP, 230 V, 10 Amp 10 KA (in accordance with IS/IEC 60898-1), fixed on porcelain insulators, making holes on strips for connecting cables, fixed to street light pole with and including 2 Nos MS clamps made of FI 25x5mm with nut, bolt & washer duly painted with two coats of synthetic enamel paint over a coat of red oxide zinc chrome primer , complete all as specified & directed. Note : Wiring from DB to light fitting shall be measured & paid saperately under respective item of Sch 'A'.
Earthing complete with galvanized mild steel earth plate electrode size 600mm x 600mm x 6mm thick buried directly in ground (preferably in vertical position) earth pit not less than 2.25 meter below normal ground level with top edge of the earth plate not less 3 meter (BGL), connected to galvanized iron earth strip 32x6mm size by means of bolts, nuts, check nut and washer of galvanized iron including PCC pit in RCC 1:2:4 type B-1, precast RCC cover with suitable handle, excavation and earth work in any type of soil, 20mm bore “medium grade” galvanized iron water tubing fixed with cast iron funnel and wire mesh and 50mm bore 'light grade' galvanized iron protection pipe for earth lead wire upto 5m length, charcoal, common salt etc including connected to test point and testing on completion, complete all as shown in electrical plate No 3 of SSR Part-I 2009 & as directed.
Taking out old/ unserviceable damaged existing steel/concrete poles of any size/length from existing position including necessary excavation and demolition of PCC foundation and removing the same from site, complete all as specified & directed.
Steel tubular swaged poles in vertical position swaged type 410-SP-31, 9 Mtr long, ISI marked complete with cast iron base plate, finial taper plug, bolts, nuts washers and screws as required duly painted with two coats of aluminium paint over a coat of red oxide primer above ground level including painting throughout internally & below GL (externally) with two coats of bituminous paint, numbering of poles with cut stencil lettering in size 6mm thick and 50mm high and yellow and black strips of size 30cm width each with synthetic enamel paint upto 1.5m above coping etc, complete all as specified and directed. Note:- 1. Earth work and PCC will be measured and paid seperately under appropriate items.
Structural steel work as in cross arms, bracings, supports, clamp and back plate fabricated from steel sections including nuts, bolts, washers, welding, bending cold or hot, drilling holes for bolts, in any shape or size as indicated or directed by Engineer-in-Charge and applying two coats of aluminium paint over one coat of red oxide zinc chrome primer after preparation of surfaces including dismantling of existing cross arms, complete all as specified & directed.
Shackle type insulator porcelain vitreous white, brown or green 75mm high and 90mm dia for conductor of working pressure 1100 volts including galvanised mild steel straps of 31x5mm size, 14mm dia insulator bolts, washers and nuts including dismantling of existing insulators, complete all as specified & directed.
Pin type insulator porcelain, vitreous, white/brown or green including one galvanized mild steel spindle, two galvanized iron washers and one galvanized iron nut, 65mm dia and 100mm height for working pressure 1100 volts grade including dismantling of existing insulators, complete all as specified & directed.
SATISH AND CO
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart shows the information on this page on a best-effort basis and does not guarantee that it is accurate, complete or current. Check it against the buyer's official notice and documents before you act on it; the official record prevails. TenderKart is not liable for any loss or claim arising from the use of this information. If you notice any error or omission, please let us know at .