Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹25.0 LAccepted-AOC | L1 | Accepted-AOC Being Lowest | |
| 2 | L2₹25.9 L+₹44,432.92 (1.74%)Rejected-Finance B XXIII 56 A PREM NAGAR SAINGARGH PATHANKOT 145001 PUNJAB | PATHANKOT | PATHANKOT | PUNJAB | 145001 | L2 | Rejected-Finance Not Lowest | |
| 3 | L3₹27.7 L+₹2.2 L (8.76%)Rejected-Finance | L3 | Rejected-Finance Not Lowest | |
| 4 | L4₹28.2 L+₹2.7 L (10.5%)Rejected-Finance 225 NAROT COLONY MODEL TOWN PATHANKOT PB 145001 | PATHANKOT | PATHANKOT | PUNJAB | 145001 | L4 | Rejected-Finance Not Lowest |
Tender Value
Refer Docs
EMD Value
₹62,000
Closing Date
29 Oct 2021, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE (SOUTH) PATHANKOT
GE (SOUTH) PATHANKOT
SPL REPAIR TO BLDG NO P 069 OF MD ACCN AT MIL STN UNCHIBASSI UNDER GE SOUTH PATHANKOT
2021_MES_478921_1
GES/PKT/T-30/2021-22
Open Tender
Civil Works - Others
Item Rate
180 days
GE (SOUTH) PATHANKOT
Please refer Tender documents.
9 documents required · 9 mandatory
₹500
GE (SOUTH) PATHANKOT
₹62,000
Yes
17 Feb 2022
30 Sept 2021
1 Nov 2021
30 Sept 2021
29 Oct 2021
15 Oct 2021
60 days
Amount
Taking down chowkats of frames (without taking down shutter from the frame) not exceeding 1.5 Sqm each and removing from site, complete all as specified & directed.
Taking down chowkats of frames (without taking off shutter from the frame) exceeding 1.5 Sqm but not exceeding 4 Sqm each and removing from site complete all as specified & directed.
Taking down shutter of any description exceeding 1 Sqm and not exceeding 2 Sqm each and removing from site complete all as specified & directed.
Factory made 2nd class hard wood 35mm thick glazed and skeleton shutter, open rebated and prepared to receive glass gauge etc, (with sash bars any numbers) edges of framing plain chamfered or rounded fitted with cut and mitered beads for securing glass etc sizes of members of shutter as specified in SSR Part-I section 8, clause 8.24 (a) kiln seasoned and chemically pressure treated completed all as specified & directed.
Factory made 35mm thick plain framed panelled shutter (two panel) of second class hard wood rail and style with lock rail and panel of 9mm BWP commercial ply. The size of rail and style as per IS 1003 Part-I kiln seasoned and chemically pressure treated, all as specified and directed.
Pressed steel frame for door with one or more rebates including necessary fixing lugs, hinges,lock strike plate etc of size 105x60mm made out of 1.25mm thick MS sheet, complete all as specified and directed.
Pressed steel frame for door with one or more rebates including necessary fixing lugs, hinges,lock strike plate etc of size 125x60mm made out of 1.25mm thick MS sheet complete all as specified and directed.
PCC 1:3:6 Type C-1 (using 20mm graded aggregate) as in back filling of pressed steel frames and similar work, complete all as specified and directed.
M&L solid PVC door frame of size 50mmx47mm made out of 5mm plain colour PVC sheet reinforced with MS square tube supplying and fixing in opening, complete all as specified and directed.
Factory made solid panel PVC door shutter 30mm thick (style) consisting of frame made out of MS tubes for top and bottom rails. MS frame shall be covered with heat molded plain colour PVC 'C' channel having a PVC sheet strip of 20mm width stuck inside with solvent cement or stiles and plain colour PVC sheets for top rain lock rail and bottom rail on either side and as gap insert for top rail and bottom rail. Panelling of plain colour PVC sheet to be fitted in the MS frame welded/ sealed to the stiles and rails with suitable PVC sheet beading and joined together with solvent cement supplying and fixing in the frame at site as per specification in SSR Part-I.
Steel windows of Z section with side hung shutters including projecting type hinges with steel handles,2 Nos steel tower bolts 100mm long peg stay complete with glazing bars, devetailed or welded including locking arrangements complete all as specified directed.
All as per serial item No-11 above but without glazing bars.
M&L for Steel windows or ventilators, fixed type, with glazing bars, complete all as specified and directed.
M&L for Steel ventilator with top hung shutter including hinges, steel peg stay, complete all as specified and directed.
M&L for mild steel framed work such as grills grating etc with ends of bars shouldered and or riveted etc, complete all as specified and directed.
Galvanized mild steel wire cloth 0.46mm nominal dia of wire and average width of aperture 1.18mm and fixed with tinned tacks or galvanized wire staples, complete all as specified and directed.
Hacking out old broken glass (any thickness, size quality or description) from wooden/steel frames or stone concrete or brick surrounds glazed with putty or fixed with beads, complete all as specified and directed.
M&L for sheet glass ordinary quality 3mm thick and glazed with oil putty or wooden beads in square n.exc 0.5 Sqm each pane, complete all as specified and directed.
M&L for 3mm thick figured glass, pin head type and glazing with oil putty in squares n exc 0.5 sq. m in each pane, complete all as specified and directed.
S&F Mild steel sliding door bolts,plate type, stove enamelled black, with bright bolt not less than 12mm dia with and including a minimum of 6 bolts and nuts, four on bolt plate and two on staple plate and fixed 300mm long, complete all as specified and directed.
S & F Aluminium anodized barrel tower bolt of extruded section of size 150mm long, complete all as specified and directed.
S&F Aluminum Handle cast type anodized of size 150mm, complete all as specified and directed.
S&F floor door stopper of aluminium body two legged 50mm size, complete all as specified and directed.
Supply only butt hinges, medium weight cold rolled mild steel 100mm size, complete all as specified and directed.
Material & labour for 25mm thick flush shutter, solid core construction, with block board core and plywood face panels, commercial type on both sides, including fixing Ist class softwood beading of size 20x20mm over all sides and fixed with screws to frame, complete all as specified and directed.
Supply only butt hinges, medium weight cold rolled mild steel 75mm size, complete all as specified and directed.
Hasp and staple aluminium anodized size 100mm including bolt to hinge plate and fixed with screws, complete all as specified and directed.
S&F framed work as in doors or gates of angle or other section with gusset plates, rails, braces, etc., complete, drilled for fixing of steel sheeting or other covering. Doors, etc. to be prepared for hanging or sliding with and including either hooks and hinges or steel hanging door fittings (exclusive of steel sheeting or other covering, running rails and guides) and hanging; also fastening and fixing, complete all as specified and directed.
S&F mild steel stove enameled helical door spring 150mm size fixed to pressed steel frame/MS frame/ wooden chowkhats including necessary welding work etc (if required) , complete all as specified and directed.
Dismantling floor, hearth or wall tiling including cement mortar bedding (But not backing) removing serviceable tiles to store and rubbish off the premises, complete all as specified and directed.
M&L for glazed ceramic tiles in vertical surfaces joint free 300x200x7mm th set and jointed in neat cement slurry and pointed in white cement to match, including rendering 15mm thick in cement mortar 1:4 on fair faces of brick work or concrete surfaces finished fair and even to receive tiles as on walls, complete all as specified and directed.
M&L for edge cut joint free glazed/matt finish coloured or printed ceramic tile surface area exc 0.11 Sqm and n.exceeding 0.18 Sqm of size 400x400x7 to 8mm thick as in floors set and jointed in neat cement slurry. including screed bed or bedding layer of cement mortar (1:4) 15mm thick for, complete all as specified and directed.
All as per serial item No-33 above but as in skirting on 10mm thick rendering in cement mortar 1:4 complete all as specified and directed.
M&L for PCC (1:2:4) Type B-I, using 20mm graded aggregate as in floor 25mm thick finished even & fair, complete all as specified and directed.
Material and Labour Chequered cement concrete tiles 30cm x 30cm x 22 to 25mm thick, set, jointed and pointed in neat cement slurry with grey cement and pigment in floors, complete all as specified and directed.
M&L for providing 100mm thick type D-2, 1:4:8 (using 40mm graded crushed stone aggregate) as in sub base flooring, complete all as specified and directed.
M &L 75mm thick PCC (1:3:6) Type C-1 (using 20mm graded stone aggregate) as in plinth protection/paving finished even & smooth w/o using extra cement, complete all as specified and directed.
Roughening surfaces of old concrete floor and cleaning of all foreign materials such as fungus, moss, dust etc. by wire brushing and dusting picking, sweeping clean and washing down with water to remove dust, etc with and including taking out existing roof treatments, brushing neat cement slurry with 3.0 Kg of cement per sqm, complete all as specified and directed.
M&L for screed bed or bedding layer 10mm thick in cement mortar 1:3 mixed with water proofing compound on concrete surface in roof complete all as specified and directed. (Note :- WPC shall be measured separately)
Providing and laying of water proofing treatment of roof APP (Atactic Polypropylene) modified prefabricated five layered 3mm thick water proofing membrane, super thermolay non woven polyester mat reinforcement of 160 gms, weight of membrane @ 3.60 Kg/Sqm over a solvent based bitumen primer, Shalitex Primer @ 0.30 Ltr per Sqm by the same manufacturer conforming to IS:3384-1986 , The membrane shall be laid using bitumen torch. The end lap should be 100mm and the side lap must be minimum 75 mm the membrane shall be first laid up to the parapet wall junction and then shall be overlapped with another membrane (flashing) with an overlap covering up to a distance of 300mm. In case parapet height is less than/up to 500mm, membrane shall be terminated at the top of parapet. All rain water pipe opening shall be suitably sealed with the APP membrane all as specified and directed. (NOTE:- The work shall be executed through authorized applicator approved by the manufacturers of membrane).
PCC (1:2:4) type B-0 (using 12.50 mm graded crushed stone aggregate) as in roof padding with liquid WPC laid to slopes as directed and approx thickness 75mm or less and finished the surfaces even and smooth without using extra cement complete all as specified and directed.( WPC shall be measured separately)
PCC(1:2:4) type B-1 using 20mm graded crushed stone aggregate as in coping benching, path etc, complete all as specified and directed.
Demolition of cement concrete (reinforced) of any description and in any position not otherwise specifically provided for reinforcement cut as required to facilitate demolition, complete all as specified and directed
Providing precast cement concrete (1:2:4) type B-1 using 20mm graded crushed stone aggregate as in cover slabs and similar articles including necessary moulds/ formwork set in cement mortar (1:6) complete all as specified
Mild steel TMT bars 6mm to 8mm dia cut to length bent to shape required including cranking, bending, binding with mild steel wire (annealed) not less than 0.9mm dia all as specified and directed.
Mild steel TMT bars 10mm dia and over cut to length bent to shape required including cranking, bending, binding with mild steel wire (annealed) not less than 0.9mm dia, complete all as specified and directed.
M& L for brushing & cleaning surface of sunken floors & surface painting with layer of blown bitumen of any penetration and applied hot @ 1.7kg/Sqm, complete all as specified and directed.
M&L for PCC (1:4:8) type D-2 using 40mm graded crushed stone aggregate as in foundation filling and mass concrete, complete all as specified and directed.
M&L for PCC (1:2:4) Type B-I, using 20mm graded aggregate as in sunken floor 50mm thick(avg thickness) finished even & fair using WPC compound.( WPC shall be measured separately)
M & L for rendering 15mm thick in cement mortar 1:3 on fair faces of brick work or concrete surfaces finished even and smooth without using extra cement with waterproofing compound as in sunken floor or external plaster complete all as specified. Note : ( WPC shall be measured separately).
Supply only Liquid Water proofing compound, complete all as specified and directed.
Demolition of cement concrete in ground floors and pavings n.exc 15cm thickness below or above ground level.
Demolition of brick work built in CM including all quoins, pillars, complete all as specified and directed.
M&L for brick work with sub class 'B' bricks straight or curved on plan exceeding 6mm cum radius built in CM (1:6), complete all as specified and directed.
All as per serial item No 55 above but except bricks.
M&L for brick work with sub class 'B' bricks straight or curved on plan to any radius built in CM (1:4) half brick thick, complete all as specified and directed.
Rendering 15mm thick in cement mortar 1:4 on fair faces of brick work or concrete surfaces finished even and smooth without using extra cement complete all as specified.
Extra for forming fair finished drain or channel 30 cm inner girth in CM, using extra cement incl forms, moulds etc
M&L for PCC 1:2:4 type B1 (using 20mm graded stone aggr) in surface channels and drains incl all necessary form work
Taking down old broken cast iron pipes from existing sewage line or along plumbing stack along the walls including necessary excavation in trenches where required, removal of surplus soil and returning filling in complete, supplying, laying in trenches or along the walls with MS clamps of standard specifications and jointing of new 110mm PVC (SWR) pipes single socketed, in any length with rubber ring joints, laid in trenches / floors or in walls pipe complete all as specified and directed.
All as per serial item No. 61 above but for 75mm dia PVC (SWR) pipes all as specified
S&F for PVC(SWR) cowls for 110mm dia bore pipe, complete all as specified and directed.
S&F for PVC (SWR) junction single, (Single T) equal or unequal for 110mm dia bore with access door.
S&F PVC (SWR) junction single, (Single T) equal or unequal for 75mm dia bore with access door, complete all as specified and directed.
S&F PVC(SWR) bend any radius for 110mm dia bore pipe with access door, complete all as specified and directed.
S&F PVC(SWR) bend any radius for 75mm dia bore pipe with access door, complete all as specified and directed.
S&F PVC (SWR) traps 110/110mm bore 'P' type all as specified, complete all as specified and directed.
S&F PVC (SWR) floor trap 75mm dia, plain with grating including jointing with solvent cement all as specified
S&F PVC (SWR) multi floor trap 75mm dia, plain with grating including jointing with solvent cement all as specified
S&F stainless steel Plate rack of size 900x600mm with 1mm thick steel complete all as specified and directed.
Drapery rod (curtain rod) of 25mm dia, of length 1.5 m to 1.8 m each complete with end brackets/caps complete.
Taking down cement plaster on brick or stone walls etc including raking out joints, hacking for key scrubbing down with water etc.
Rendering 10mm thick in cement mortar 1:3 on fair faces of brick work or concrete surfaces finished even and smooth without using extra cement as in ceiling complete all as specified.
Rendering 15mm thick in cement mortar 1:4 on fair faces of brick work or concrete surfaces finished even and smooth without using extra cement complete all as specified
Rendering 15mm thick in cement mortar 1:6 on fair faces of brick work or concrete surfaces finished even and smooth without using extra cement complete all as specified
Taking up or down steel tubing and connection and removing to store bore of pipe 15mm dia, complete all as specified and directed.
S&F GI tubes medium grade bore of pipe 15mm fixed to wall of laid in floors etc complete with all fittings, complete all as specified and directed.
All as per serial Items No-78 above but fixing only
Taking up or down steel tubing and connection and removing to store bore of pipe 20mm dia
S&F GI tubes medium grade bore of pipe 20mm fixed to wall of laid in floors etc complete with all fittings
All as per serial Items No-81 above but fixing only
S& F brass chromium plated shower rose 125mm size including fixing to steel pipe, complete all as specified and directed.
S& F bib tap cast copper alloy CP brass 15mm bore of pipe, complete all as specified and directed.
S&F in repairs 15mm bore, Angle valve fancy type chromium plated cast copper alloy ISI marked with crutch or butter fly handle high pressure screwed both ends for iron pipe or for union and fixed, complete all as specified and directed.
M&L Pillar taps, cast copper alloy with capstan heads chromium plated fancy type screwed down high pressure with or without lettered hot or cold with long screwed, shanks and fly nuts, screwed for iron pipe 15mm dia fixed in repairs, complete all as specified and directed.
S& F CP brass Stop valve concealed type 15mm dia fancy type chromium plated with long sank and cup complete all as specified.
S&F Gun-metal, globe or gate valves 20mm bore, with iron wheel head, screwed both ends for iron pipe and fixed complete all as specified
S&F PVC low level flushing cistern white 10 ltr capacity with PVC flush complete fixed in repairs.
S&F Tubular towel rail, brass chromium plated, 20mm dia, D type, 60cm long between flanges, complete all as specified and directed.
S&F Shelf PTMT fixed with and including chrominum plated brass screws and wooden/plastic cleats (minimum weight 300gms), complete all as specified and directed.
S& F PVC connection 15x600mm long with PTMT nuts & bolts, complete all as specified and directed.
S&F Vitreous China (flat back or angle back type) wash hand basin, white, flat back, size 450x 300mm including brackets any size, PTMT waste coupling 32mm, waste pipe 32mm dia, cutting for and pinning in ends of brackets or erecting stand.complete all specified and directed.
S& F in repair Vitreous China squatting pan, ‘Orissa’ pattern, size 580 x 440 mm white, with integral foot rests (excluding flushing cistern and flush pipe) including connection to trap, and to flushing pipe, anti-syphonage pipe,etc. complete including making good to floor, complete all as specified and directed.
Supply & fixing rotational molded polyethylene water storage tank (cylindrical vertical with closed top) hoisted and fixed in position of 500 liters capacity each triple layered including dismantling / demolition of any type of storage tank.
Preparation of new or untreated wood or wood based surfaces of any description exc 10cm in width or girth and applying two coats of synthetic enamel paint over a coat of pink primer, complete all as specified.
Preparation of new or untreated steel surface of any description exc 10cm in width or girth and applying two coats of synthetic enamel paint over a coat of red oxide primer, complete all as specified.
M&L for applying one coat of synthetic enamel paint on steel surface of any description not otherwise described over 10cm width of girth incl preparation of old painted surfaces all as specified and directed.
M&L for preparation of old surfaces and applying two coats of white wash on ceiling incl complete removal of existing treatement, complete all as specified and directed.
M&L for preparation of new surfaces and applying three coats of white wash on ceiling incl complete removal of existing treatement, complete all as specified and directed.
Preparing of new plastered or unplastered surface of wall including and applying one coat of oil bound distemper over a coat of primer on walls as per specified and directed.
Preparing of old plastered or unplastered surface of wall and applying one coat of oil bound distemper on walls, complete all as specified and directed.
Preparing of new plastered or unplastered surface of wall including and applying two coat of cement base paint over a coat of primer on walls, complete all as specified and directed.
Preparing of old plastered or unplastered surface of wall and applying one coat of cement base paint on walls, complete all as specified and directed.
Demolition of stone slabs and tiles of any description or thickness in floors, aprons etc set in any type of mortar.
M&L for Granite (of any type) work, 16-18mm thick (table rubbed and polished) in steps, jambs, pillars, window cills, cooking platforms and like, incl 20mm thick cement mortar (1:4) including pointing in white cement (1:2) using marble dust with admixture of pigment to match with shade of granite incl rounding to edge of stone slab complete all as specified and directed.
Machine cut kota stone slab flooring 16-18mm thick laid over screed bed or bedding layer in cement mortar 1:4, 15 mm thick for laying floor finishes and jointed with grey cement slurry mixed with pigment to match the shade the slab including machine cutting to make it square or rectangular, rubbing and cutting and polishing with wax polish, ,incl rounding to edge of stone slabs one edge as in steps, complete all as specified and directed.
Kota stone slab 10-12mm thick in riser of steps, skirting, dado and pillar laid over cement screed and jointed with grey cement slurry mixed with pigment to match the shade of the slab including machine cutting to make it square or rectangular, rubbing and cutting and polishing with wax polish complete and including rendering 15 mm thick on fair faces or other than fair faces of brick work in cement mortar 1:3, finished even and fair as in backing layer, complete all as specified and directed.
S&F for Plain, Aluminium sheeting, Alloy 31000 H4, 056mm thick in ridges, hips, valley gutter, drip and straight flashing (length and girth as fixed, complete all as specified and directed.
Taking down carefully point wiring of any type, size and description from hard/ teak wood batten/through pipes/casing capping (light, fan, sockets and socket outlets etc) including removal of battens, pipes, plug sockets, socket outlets, switches, shades, ceiling roses, light fittings etc. complete and making good the disturbed surface to match with existing all as directed by Engr-in-Charge.
Taking down main switches, distribution boards and cut outs etc. of any type and capacity along with the existing boards and removing the same from site and making good the disturbed surface/portion of walls all as directed by Engr-in-Charge.
Taking down carefully sub main wiring of any nos of wire and size with earth wire from wooden batten/surface conduit/casing caping complete with its all accessories
M & L for point wiring complete with PVC insulated unsheathed, 1100 volts grade cable 1.5 Sqmm (nominal area) FRLS type multi stranded copper conductor, single core drawn in and including not less than 20 mm dia rigid PVC conduit 'medium grade' ISI marked including all conduit accessories on surface wiring with top cover of 03 mm thick plastic laminated sheet of required colour for mounting switch, sockets, fan regulator etc including 1.5 Sqmm FRLS type PVC insulated unsheathed cable multi-stranded copper conductor as continuous earth wire and connected to earth dolly as required at site& including chases cutting & making good disturbed surface & applying finishes to match existing surface etc. all as specified for the following :-
One light/fan point controlled by one, one way switch single pole.
One 3 pin 5 Amps socket point on the same board.
One 3 pin 5 Amps socket point on independent board.
One light point controlled by two,two way switch .
One buzzer/bell point controlled by one, one way bell push.
All as per item No 113 above but point wiring with 2.5 sqmm cable and 2.5 sqmm earth continuity conductor for 3 pin / 5 pin 15 Amps socket, complete all as specified and directed.
All as per item No 113 above but point wiring with 4 sqmm cable and 4 sqmm earth continuity conductor for 3 pin / 5 pin 15 Amps socket, complete all as specified and directed.
S&F switch piano, single pole one way 5 Amps 240 Volt capacity flush type, complete all as specified and directed.
S&F Switch socket combination2 in 1, 5 pin , 5 Amps flush type, complete all as specified and directed.
S&F 3 pin 15Amps switch socket combination flush type multi purpose 2 in 1 type (3 pin 5 Amps and 15 Amps), complete all as specified and directed.
S&F in repair ceiling rose of size 65 x 50 mm surface bakelite 240 Volts three terminal as specified and directed.
Supply and fixing sheet metal enclosure single pole and neutral with a 2 pin and earth plug and socket 20 A 240V complete with one single pole MCB of capacity 20 A complete all as specified and directed.
S&F in repair stepped type electronic fan regulator flush type AC 230 volt suitable for any type of ceiling fan all as specified and directed.
S&F in repair Lamp holder, PVC/ Polycarbonate type with back plate suitable for batten fittings complete all as specified and directed.
M & L for replacement of existing un-serviceable bell push ISI marked, complete all as spd and directed.
S&F electric bell ding dong type AC 230 volt 50 Hz single phase single pole all as specified and directed.
Supply & Fix LED bulkhead fittings luminaires with opal diffuser including (LED lamp type 10W LED 6000K) lamp holder etc. complete all as required or directed.
Supply & Fix inverter type LED fitting 1 x 20W, including LED tube 4' long having bipin holder, connector blosk, driver etc 230 Volts, duly prewired and electrical connections upto ceiling rose using PVC insulated overall sheathed flexible copper conductor cable of size 0.5 Sq mm 03 core complete all as required or directed.
Supply and fixing LED light fitting mirror type with high out put diffuser 2 feet, 10 watt 220 V AC decorative type with driver holder and LED lamp including connecting up with three core flexible copper conductor cable of suitable size complete.
S&F LED Lamp 230 volts,50 Hz,inverter LED 12/15 watt ,lumen 900 lm, rated current 0.045A, CRI less than 80, Charging time 8 to 10 Hours, operating temperature -10 to 50 degree celcius,back time 04 Hours, complete all as specififed and direccted.
Supply & Fix in replacement ceiling fan AC single phase 230/240 volts of size 1200 mm sweep complete type BEE rated BLDC rated complete with blade set ,down rod, copper wound fan motor , canopy set, shackle kit etc including connecting to ceiling rose with 3 core 0.5 sqmm flexible copper wire all as required or directed . Note: Old retrieved fans shall be deposited to MES store yard by contractor
Supply and fixing in repair Ventilation fan AC sinlge phase 230/240 volts of size 225 to 250 mm sweep PVC body with louvre including connecting to ceiling rose and dismantling old UNSV fan and depositing to MES store yard all as specified and directed.
Supply & Fix Exhaust fan AC sinlge phase 230/240 volts of size 300 mm sweep steel body with louvre including connecting to ceiling rose and dismantling old UNSV fan and depositing to MES store yard, complete all as specified and directed.
Supply and fixing in repair LED inverter street light 45W with RTC having luminium housing with clear toughened glass front coveer, IP 66 protection, operating voltage of 140V to 270V, having an efficiency of upto 02 hrs backup, reserve polarity protection , hight voltage cut off at 300V+- 10V and 5 KV internal surge protection with a power factor greater than 0.95 complete making connection with street light box or OH line using PVC insulated and sheathed single core multi stranded alumn conductor cable of size 2.5 Sqmm, complete all as specified and directed.
Supply fixing and testing storage type electric water heater of 25 ltr capacity, BEE 5 star rated suitable for 8 bar pressure with nano polymer coated tank, incoloy heating element, rust proof ABS body etc including dismantiling old unservicable geysers complete all as specified and directed.
Supply and draw sub main wiring in repairs of two run 6.0 sqmm single core PVC insulated, unsheathed multistranded copper conductor cable 1100 Volt grade, drawn through and including PVC conduit medium duty and accessories of not less than 25 mm size ISI marked including all conduit accessories for concealed to the surfaces of the wall/ceiling including one run of 6.0 sqmm single core PVC insulated unsheathed copper earth continuity conductor all as specified and as directed. (NOTE : Two runs of single core cable with one run of earth continuity conductor including PVC conduit accessories shall be measured and paid as one length.) including making good disturbed surface all as specified and directed.
M & L for LT underground Cable XLPE insulated, heavy duty armoured sheathed 1100 volts grade 16Sq mm, 4 core, with aluminium conductor, ISI marked as per IS : 7098 (Part-1), complete all as specified and directed.
M&L for Sub class ‘B’ bricks old size laid dry flat over the cable abutting each other, length of cable equal to width of brick all as required.
Supplying & Laying in trenches clear sand for cushioning under ground cable 8 cm below and 15 cm above complete in level all as specified.
S&F in replacement iron clad, with double door 4 way IP-54, 1K-09 protection, cement sprill prptector sutable for MCCB as incommmer AC 415 Volts three pole with thermal release adjustable type (80% to 100%) and MCB as outgoing complete with appropriate size copper bus bar and neutral link complete with one MCCB 3 ple 415 Volts 125 Amps rating with rupturing cap 25 KA of the same make as of distribution board & including cutting chases to wall for fixing DB and making good the disturbed wall surface all as required at sit or directed. ( Outgoing MCB will be measured speparately)
Supply and fixing sheet metal enclosure for double door MCB DBs, phosphatised, powder coated, Single Pole & Neutral (SPN), suitable for 8 way, 240 volts, IP 43 & IK 09 fixed on wall with din rail, neutral and earth bar, in proper position and takingdown old one, complete all as specified and directed.
Supply & fixing MCB Single Pole and Neutral (SPN) of capacity 32 to 63 Amps, 240 Volts, breaking capacity 10 KA, ‘C’ series, fixed in proper position and takingdown old one, complete all as specified and directed.
Supply & fixing in repair MCB Single Pole (SP) of capacity 6 to 32 Amps, 240 Volts, breaking capacity 10 KA, ‘C’ series, fixed in proper position all as directed by the Engineer-in-Charge.
Earthing complete with galvanized steel earth plate electrode 60cmx60cmx6 mm thick buried directly in ground (Earth pit not less than 2.25 Mtr deep below normal ground level )with top edge of the plate not less than 1.5 Mtr below normal ground level connecting with galvanized iron GI earth wire 4mm dia by means of bolt nut check nuts and washers of galvanized iron and provision of GI tubing medium grade (ISI marked) of size 15mm for protection of GI earth wire upto test point, 20mm dia GI light grade watering pipe with funnel and wire mesh, RCC pit cover of size 300x300x40mm reinforced with XPM having weight not less than 4Kg/ sqmm including 6mm thick MS bar handle made to shape, PCC pit with 1:3:6 type C1 with angle iron frame made of angle iron of size 40x40x4mm, adequate qty of charcoal dust and salt layers all around the earth plate, excavation , earth work in any type of soil, removal of excavated soil and returning filling in all as required at site complete all as specified in plate No 3 of SSR Part-I and all as specified or indicated including testing on completion.NOTE :-Rates inclusive of necessary excavation in any type of soil, earth work, PCC pit, RCC cover, funnel with watering pipe, GI earth strip upto 7.5 m long for connecting to test point etc. all as required at site for complete earthing).
Disconnecting and taking down existing tamper proof electric meter single phase, Re-assembling and refixing to the same /other location alongwith replacement of meter fixing box made out of thermoplastic grey colour with transparent cover, cable entry cover, hinged flap, protection cover including cable entry integrated elastic membrane suitable to accomodated two single phase KWH meter and fixing meter box to flush wall and making connection with proper thimbles, good disturbed surfaces, refixing seals and wires of the fixing the existing meter in meter box complete all as specified and directed. Note : Any damage caused to old serviceable meter while opening/refixing the same shall be make good/replace with new meter by contractor without claiming any extra cost on this account.
Excavation in trenches not exc 1.5 m wide and not exc 1.5 mtr deep hard /dense type of soil getting out and levelling of bottom surface to required level for poles/stay assebly/cable all as specifed and directed.
Returning filling in, including spreading, leveling, watering and well ramming in layers not exc 25m thick, complete all as specified and directed.
Removing excavated material from site to a distance not exc 50 mtr away and depositing where directed not exc 1.5mtr from the starting point all as directed.
M & L GI Pipe light grade 40 mm bore for cable protection as a guard pipe, complete all as specified and directed.
Cutting existing steel tubing for alternations or additions and screwing existing steel tubing for alternations or addtions or lengthening screwd on pipe to from connector up to 50 mm bore, complete all as specified and directed.
Supplying & Laying of 50mm bore GI pipe medium grade in trenches indluding all fittings, complete all as per specified & directed.
Supplying & Laying of 40mm bore GI pipe medium grade in trenches indluding all fittings, complete all as per specified & directed.
Supply and fix 50mm bore gun metal gate valves with iron wheel head, screwed both ends for iron pipe ISI marked as per IS 778, complete all as per specified & directed.
All as Srl Item No. 156 above but for 20mm bore.
Construction of valve chamber of size 70 cm x 70 cm x 70 cm with PCC base foundation of thick 15 cm and the wall with PCC hollow blocks with necessary internal plaster of thickness 15mm complete with chamber cover made up 3.15 mm thick MS black sheet hinged both ends including necessary locking arrangement and fixing the same with angle iron frame of size 40x40x6mm thick and all steel structures to be painted with one coat of primet over one coat of black bitumen paingt all as per the direction of Egnr -in - charge.
Note: In case the tenderer quotes different rates for similar item then lowest rate shall only be applicable for payment and contractor shall not have any claim on this account.
SATISH AND CO
INDERJIT SINGH
M/S SHRI RAM BUILDERS
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .