Tender Value
₹12.8 L
EMD Value
₹25,500
Closing Date
15 Dec 2020, 6:00 pmClosed
GE 867 EWS
GE 867 EWS C/O 99 APO PIN 913867
SPL REPAIRS FOR AUGMENTATION OF STANDBY POWER SUPPLY OF PERIMETER FENCING AT PEDONG AND SPL REPAIRS TO BLDG NO. T-228 AT TEESTA TCP UNDER GE 867 EWS
2020_MES_387552_2
CA NO GE / 867 / TOKEN / 53 OF 2020-2021
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
Pedong
Refer tender documents
8 documents required · 8 mandatory
₹500
GE 867 EWS
₹25,500
Yes
5 Jan 2021
25 Nov 2020
16 Dec 2020
25 Nov 2020
15 Dec 2020
2 Dec 2020
25 Nov 2020 - 30 Nov 2020
Amount
S&F 0.63 mm thick galvanised, corrugated mild steel sheeting with two corrugation side lap fixed with "L" or "J" type hook bolts and bitumen washers as in roof covering etc., with grade of Zinc coating 275 Grms/Sqm including taking down existing steel sheetng of any type complete all as specified and directed by Engineer-in-Charge.
S&F 0.80 mm thick galvanised, plain mild steel sheeting fixed with "L" or "J" type hook bolts and bitumen washers as in ridges, hips,valley gutters, drip and straight flashing etc.,with grade of Zinc coating 275 Grms/Sqm including taking down existing steel sheetng of any type complete all as specified and directed by Engineer-in-Charge.
Taking down existing 0.63 mm thick galvanised, corrugated mild steel sheeting and refixing in same location or in new location in same building with two corrugation side lap fixed with "L" or "J" type hook bolts and bitumen washers as in roof covering etc., complete all as specified and directed by Engineer-in-Charge.
Dismantling timber scantlings 40 Sqcm and over in section, framed work in any position complete all as specified and directed by Engineer-in-Charge.
S&F Fe 410-W (Gde-E- 250) quality-A Rolled steel sections, as in Roof trusses (framed), trussed, purlins, crane gantries, rails and fastenings and heavy bracket framing (Beam, tee, angle, channel or flat sections) including distance pieces, cleats etc., complete all as specified and directed by Engineer-in-charge.
M&L preparing new wooden surfaces of any description over 10 cm width or girth and applying two coats of synthetic enamel paint over one coat of pink primer complete all as specified and directed by Engineer-in-Charge.
M&L for preparation of new or previously un treated surfaces of steel and iron surfaces of any description, over 10cm in width or girth, not otherwise described and applying two coats of synthetic enamel paint over a coat of red oxide primer all as specified and directed. Make for Item No. 6&7: ASIAN/ SHALIMAR/ BERGER/ JENSON&NICHOLSON/IEL/NEROLAC/IEL
M & L for modular fly ash bricks as in brick work straight or curved on plan exceeding 6m mean radious built in cement mortar 1:6 including demolition of existing brickwork complete all as specified and directed by Engineer-in-charge.
Taking down cement plaster on brick or stone masonry surfaces of walls etc., including raking out joints, hacking for key, scrubbing down with water etc., and removing rubbish off the premises complete all as specified and directed by Engr-in-charge.
M&L for rendering 15 mm thick on brickwork or concrete surfaces in cement mortar 1:6 finished even and smooth without using extra cement complete all as specified and directed by Engr-in-charge.
M&L for rendering 15 mm thick on brickwork or concrete surfaces in cement mortar 1:4 finished fair and even including waterproofing compound @ 3% by weight of cement as per manufacturer's instructions complete all as specified and directed by Engr-in-charge.
M&L for preparing newly plastered surfaces and applying three coats of white wash complete all as specified and directed by Engineer-in-charge. Make: LOVELYCEM/ SURYACEM/ JANATHACEM / LUCKYCEM or equivalent make as approved by GE.
Taking down chowkats or frames with shutters (without taking off shutters from frames) area exceeding 1.5 Sqm and not exceeding 4 sqm each, including cutting holes for taking out hold fasts or dismantling brick work and making good in PCC 1:2:4 type B1 or cement mortar 1:4 (holes cut and any other damage to jambs, walls for taking out hold fast shall be finished identical to existing finish without any extra cost to Govt.) complete all as specified and as directed.
Taking down chowkats or frames with shutters (without taking off shutters from frames) area not exceeding 1.50 sqm each, including cutting holes for taking out hold fasts or dismantling brick work and making good in PCC 1:2:4 type B1 or cement mortar 1:4 (holes cut and any other damage to jambs, walls for taking out hold fast shall be finished identical to existing finish without any extra cost to Govt.) complete all as specified and as directed.
S&F steel window with side hung shutters (glazed or wire mesh shutters) fitted with box type hinges with suitable MS handles, peg stays, with glazing bars for receiving glass / MS flat for receiving wire mesh complete all as directed by Engr-in-charge. Make: M/s Madhu industries / M/s.SEN Harvick / AVA STEELS /M/s. Shiv Mular / M/s. AGEW. / M/s. Multiwyn Industries Corpn/ M/s Ganesh rolling shutters/M/s Venkateswara rolling shutters or equvalent make as approved by GE.
S&F Mild steel works as in grills, framed guard bars, and similar works conforming to Fe-290, Gde E-165 all as specified and directed.
S & F 3mm thick sheet glass ordinary quality fixed with oil putty and necessary clips/nut bolts area not exceeding 0.5Sqm in each pane complete all as directed by Engr-in-Charge. Make: TRIVENI/ SAINT GOBAIN/ MODIGUARD/ATUL/ HINDUSTAN or equivalent as approved by GE.
S & F galvanised mild steel wire cloth, 0.63 mm nominal dia of wire and average width of aperture 1.40 mm and fixed with tinned tacks or galvanised wire staples or wooden beeds all as specified and directed by Engr-in-Charge. Make: -Kamal/Shalimar or equivalent as approved by GE.
S & F galvanised mild steel wire cloth, 0.63 mm nominal dia of wire and average width of aperture 1.40 mm and fixed with tinned tacks or galvanised wire staples or wooden beeds including taking down existing wire cloth complete all as specified and directed by Engr-in-Charge. Make: -Kamal/Shalimar or equivalent as approved by GE.
S&F 125x60 mm size pressed steel door frame for doors with one or more rebates including necessary fixing lugs, hinges, lock strike plate, etc., including PCC 1:3:6 type C0 filling complete all as directed by Engr-in-Charge. Make: - DIWAN STEELS/Ajanta Ispat/AVA Steels or equivalent as approved by GE.
S&F 105x60 mm size pressed steel door frame for doors with one or more rebates including necessary fixing lugs, hinges, lock strike plate, etc., including PCC 1:3:6 type C0 filling complete all as directed by Engr-in-Charge. Make: - DIWAN STEELS/Ajanta Ispat/AVA Steels or equivalent as approved by GE.
S&F 30mm thick factory made flush shutters, solid core construction with block board core and plywood face panels, commercial type on both faces complete all as specified and directed by Engineer-in-Charge. Make: - Green Ply/Archid Ply or equivalent as approved by GE.
S&F 200 mm long Aluminium anodised barrel tower bolts of extruded aluminium section all as specified and directed.
S&F 150 mm long Aluminium alloy handles cast type anodised all as specified and directed.
S&F 250mm long aluminium alloy anodised sliding door bolts with hasp & staple (bolt type) and fixing clip of sheet , cast or extruded sections and fixing bolts and sliding bolts of extruded sections or cast aluminium alloy complete all as specified and directed. Make for Item No. 23 to 25: - CROWN/ CLASSIC/ JYOTHI/ AMIT/ MOWJEE/ARGENT/Bharat/Alans/Hettich/Everlite or any ISI marked make as approved by GE.
M&L 75 mm thick PCC 1:3:6, type C2 (using 40mm graded stone aggregate) in plinth protection laid in alternative bays finished even and smooth without using extra cement including making 6 mm wide grooves to full depth at 2m to 3m interval and at every change of direction and filling the grooves with mixture of bitumen and sand mixed in the ratio of 1:3 by weight including demolition of existing plinth protection and removing rubbish off the premises complete all as specified and directed by Engineer-in-Charge.
Forming 65 mm deep x 10 mm wide construction (Dummy) joint filled with sealing compound grade A complete all as specified and directed by Engineer-in-Charge.
M&L for 40mm thick plain cement concrete 1:2:4 type B1 (using 20mm graded stone aggregate) as in floors as sub base and finishing even and rough to receive toping layer including demolition of existing flooring and removing rubbish off the premises complete all as specified and directed by Engineer-in-Charge.
M&L for non skid ceramic coloured tiles 7 to 8 mm thick square/rectangular area of each tile exceeding 0.06 Sqm but not exceeding 0.11 Sqm, in floors etc., jointed in neat cement slurry and pointed in white or coloured cement to match with the colour of tiles laid on and including 15mm thick screed bed in cement mortar 1:6 complete all as specified and directed by Engr-in-charge.
M&L for non skid ceramic coloured tiles 7 to 8 mm thick square/rectangular area of each tile exceeding 0.06 Sqm but not exceeding 0.11 Sqm, ion vertical surfaces such as skirting/dado, jointed in neat cement slurry and pointed in white or coloured cement to match with the colour of tiles laid on and including 10mm thick rendering in cement mortar 1:4 backing coat complete all as specified and directed by Engr-in-charge.
M&L for coloured glazed ceramic tiles of size 300x200x7mm thick on vertical surfaces such as skirting/dado, jointed in neat cement slurry and pointed in white or coloured cement to match with the colour of tiles laid on and including 10mm thick rendering in cement mortar 1:4 backing coat complete all as specified and directed by Engr-in-charge. Make for Item No 29 to 31: NITCO/ SOMANY/ ASIAN / JOHNSON/ORIENT
M&L for point wiring with 1.5 Sqmm (nominal area) PVC insulated un - sheathed single core stranded copper conductor FRLS cable 1100 volts grade (conforming to IS) drawn through and including rigid non metallic PVC casing and capping, medium grade of suitable size with all necessary fittings, fixed on walls/ceilings etc., including 1.5 Sq mm PVC insulated copper conductor FRLS cable for earth continuity conductor and connected to earth dolly and to be terminated in 1.6 mm thick pressed steel terminal boxes concealed type/surface type for mounting fittings like switch, socket, fan regulator etc. with 3 mm thick laminated bakelite sheet cover (Make: Hylem or equivalent ) for housing switches, socket outlet, regulator etc., for one light /fan point controlled by one switch/one bell / buzzer point controlled by one bell push/one 3 / 5 -pin switch socket outlet 5 amps on independent board including taking down existing unserviceable point wiring including switches, sockets, regulators, ceiling roses, terminal boxes and making good disturbed surfaces including testing on completion complete all as specified and directed by Engineer-in-Charge.
All as per item No. 32 above but for One 3/5 pin switch socket outlet 5 amps on same board along with other switches complete all as specified and directed by Engineer-in-Charge.
M&L for point wiring with 2.5 Sqmm (nominal area) PVC insulated un - sheathed single core stranded copper conductor FRLS cable 1100 volts grade (conforming to IS) drawn through and including rigid non metallic PVC casing and capping, medium grade of suitable size with all necessary fittings, fixed on walls/ceilings etc., including 2.5 Sqmm PVC insulated copper conductor FRLS cable for earth continuity conductor and connected to earth dolly and to be terminated in 1.6 mm thick pressed steel terminal boxes concealed type/surface type for mounting fittings like switch, socket, fan regulator etc. with 3 mm thick laminated bakelite sheet cover (Make: Hylem or equivalent ) for housing switches, socket outlet, regulator etc., for one 5 / 6 -pin switch socket outlet 15 amps on independent board including taking down existing unserviceable point wiring including switches, sockets, regulators, ceiling roses, terminal boxes and making good disturbed surfaces including testing on completion complete all as specified and directed by Engineer-in-Charge.
M&L for sub main wiring complete with 2 runs of 4 Sqmm PVC insulated heavy duty and unsheathed FRLS cable with multistranded copper conductor and drawing through and including non metalic rigid PVC casing & caping of 25mm size fixed on wall/ceiling and connecting terminal ends including provision of 1 run of 4 Sqmm PVC insulated heavy duty and unsheathed FRLS cable with multistranded copper conductor as earth continuity conductor and connecting to earth dolly including taking down old unserviceable wiring and making good disturbed surfaces complete all as directed by Engr-in-charge. Note: 2 runs of 4 Sqmm and one run of 4 Sqmm and one run of Casing&Caping shall be measured as one unit length. Make for Item No. 32 to 35 Cable: (i) Finolex, (ii) Plaza, (iii) Havells, (iv) Polycab, (v) KEI, (vi) Anchor Casing&Caping: (i) Kinjal, (ii) Alwyn (iii) Harsh, (iv) Finolex (v) Berlia (vi) Plaza
S&F switch piano, flush button, single pole, 5 amps, one way complete all as specified and as directed by Engineer-in-Charge.
S&F switch socket combination 2 – in – one, 3 Pin / 5 Pin, 5 amps flush type complete all as specified and as directed by Engineer-in-Charge.
S&F switch socket combination 2 – in – one 6 Pin , 5 / 15 amps flush type complete all as specified and as directed by Engineer-in-Charge.
S&F lamp holder, PVC/Polycarbonate insulated body with back plate suitable for batten fittings complete all as specified and as directed by Engineer-in-Charge.
S&F ceiling rose 3 terminal PVC/Polycarnonate, isolated body complete all as specified and as directed by Engineer-in-Charge. Make for Item No. 36 to 40: (i) Anchor (ii) Plaza, (iii) Havells (Crabtree) (iv) ABB (v) Shalabh
S&F sheet metal enclosure DB SPN 8 way 240 V with 200 Amp rated bus bar, powder coated, double door including taking down existing DB complete all as specified and as directed by Engineer-in-Charge. Make: Legrand/Siemens/Schindler
Supply and laying in trenches, fixed to wall or drawn through pipe etc., XLPE Insulated screened PVC bedded, galvanized steel strip or wire armored, electric power cables (heavy duty) 1100 Volts grade with solid aluminium conductor of size 10 sqmm 2 core and connecting with necessary lugs including taking out exising unserviceable cable complete all as specified and directed by Engineer-in-Charge.
Supply and laying in trenches, fixed to wall or drawn through pipe etc., XLPE Insulated screened PVC bedded, galvanized steel strip or wire armored, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 16 sqmm 2 core and connecting with necessary lugs including taking out exising unserviceable cable complete all as specified and directed by Engineer-in-Charge.
Supply and laying in trenches, fixed to wall or drawn through pipe etc., XLPE Insulated screened PVC bedded, galvanized steel strip or wire armored, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 50 sqmm 3.5 core and connecting with necessary lugs including taking out exising unserviceable cable complete all as specified and directed by Engineer-in-Charge. Note for Item No. 42 to 44:- Excavation, earth work, brick protection, protection pipe and sand coushioning shall be measured and paid separately. Make of cable shall be CCI / Gloster / ICC / Unistar / NICCO / Asian (RPG) / Havells / Polycab/PRG/Universal/Plaza/Crystal cables/Terracom/ Rallison/Mescab/Jeypore/KEI
Excavating in trenches, not exceeding 1.5m wide and not exceeding 1.5 in depth for taking out /laying of cable etc., and getting out in soft/loose soil.complete all as specified and directed by Engineer-in-Charge.
Returning, filling in soil, including spreading leveling, watering and wall ramming in laying not exceeding 25 cm thick complete all as specified and directed by Engineer-in-Charge.
Removing excavated soil to a distance n.exe 50m and depositing where directed at alevel n.exe 1.5m above the starting point complete all as directed by Engineer - in -Charge.
Supply and spreading of dry sand in trenches for cable coushioning and punned down complete all as specified and directed by Engineer-in-Charge. Note:- Punned thickness only shall be measured for payment purpose.
M&L for common burnt bricks, sub class 'B', of size 250 x 125 x 75 mm laid in trenches for cable protection complete all as specified and directed by Engineer-in-charge.
Material and labour for 50 mm dia bore GI tubing Light grade, laid under roads/ floor, or fixed to wall or along the pole with suitable size M.S.flat iron clamps, nuts, bolts and washers for cable protection including taking down/out existing pipe complete all as specified and directed by Egineer-in-Charge. Make: TATA/ZENITH/JINDAL
Earhing complete with galvanized steel earth plate electrode 600X600X6 mm buried directly in ground (earth pit not less than 2.25 m deep below ground level) with top edge of the plate not less than 1.5m below ground level, connected to GI earth strip of size 32x6mm, by means of galvanized iron or steel bolts, nuts, check nuts and washers, and conneced to equipments as directed, including funnel with GI med grade watering pipe 20 mm bore, wire mesh charcoal or coke and common salt in alternate layers, of 15 cm compacted thickness all around the earth electrode, with concrete pit in PCC 1:3:6 type C-1 , 50 mm thick pre cast RCC 1:2:4 type B1 cover slab reinforced with 8 mm dia reinforced bar 15 cm C/C and suitable handle of 10 mm dia round bar, 40 mm GI medium grade pipe for earth lead protection including necessary excavation earth work in soft/loose soil and disposal of spoil to a distance n.exc. 50 m and necessary testing complete all as shown on electrical plate No. 3 of MES SSR Part-I including taking out existing earth plate etc., complete all as specified and as directed by Engineer-in-Charge. NOTE: Rate quoted shall be deemed to include for earth lead and protection pipe upto 7.5m.
M & L for DK Thermoplastic cable junction boxes IP 65 of size 185x165x60mm of metric knockouts for cable entry, weather proof for outdoor installation with and including glands and with 4 terminals for terminating one incoming and outgoing UG cable of size 16/25sqmm 2 core and fixed to the PSC/Steel Poles by means of suitable size of clamps with nut and bolts incl provn of 01 No of single pole MCB 6-32 amps,10KA ‘B’ series inside the box complete including taking down existing existing junction box all as specified and directed by Engineer-in-Charge. NOTE: Make of Junction box shall be Sintex/Hensel or equivalent as approved by GE.
Sub Total of Schedule 'A'
Schedule of Credit (Minus) Rs. 66,720.00 B/F from Ser page No. 30 NOTE: Bidder shall insert credit amount as rate Rs. 66,720.00 in Green field under Col-M. If bidder does not insert the amount the same will be deducted from total amount of Schedule 'A' and accordingly total amount of tender will be considered in deciding the lowest tender.
Sub Total of Schedule of Credit
SANJAY SAW MILL
M/S G. K. SUTHAR
JAYSHREE CONCERN
MS MAYA PRAKASH GOEL AND SONS
GARGO TRADERS
MS BRAHMA CONSTRUCTION
RAJU TAMANG
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .