| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | Ist₹4.1 LAccepted-Finance 00 HAIDARPUR JAMALPUR ROAD SADAR JAUNPUR UTTAR PRADESH 222001 | JAUNPUR | UTTAR PRADESH | 222001 | Ist | Accepted-Finance L-1 Bidder | |
| 2 | IInd₹4.7 LRejected-Finance | IInd | Rejected-Finance L-2 Bidder | |
| 3 | IIIrd₹5.0 LRejected-Finance | IIIrd | Rejected-Finance L-3 Bidder | |
| 4 | Rejected-Technical | - | Rejected-Technical Documents not found as per PQC | |
| 5 | Rejected-Technical GOPALPUR BANSI RANIGANJ DISTRICT PRATAPGARH | PRATAPGARH | UTTAR PRADESH | - | Rejected-Technical Documents Not found as per PQC |
Tender Value
₹5.3 L
EMD Value
₹5,500
Closing Date
24 Mar 2025, 12:00 pmClosed
SE, ETC-I, Varanasi
Bhikharipur, DLW, Varanasi
REPLACEMENT OF 132 KV MAIN BUS BAR OF SINGLE ACSR MOOSE CONDUCTOR TO TWIN ACSR MOOSE CONDUCTOR ALONG WITH OTHER ASSOCIATED WORK/ MATERIALS
2025_UPTCL_990966_4
Short Term E-Tender No. 21/2024-25/ETC-I/VNS
Open Tender
Electrical Works
Item Rate
30 days
132 KV Substation BHU
Fee/EMD/PAN/GST Registration and experience for execution of work as per specification
2 documents required · 2 mandatory
₹590
SE, ETC-VARANASI
₹5,500
28 May 2025
18 Mar 2025
24 Mar 2025
18 Mar 2025
24 Mar 2025
19 Mar 2025
Amount
Supply
Bolted type Double tension fitting for twin moose bundle ACSR conductor without turn buckle for 132 KV Main Bus comprising with D-Shackle socket, Ball link, Yoke Plate, D-Clip and 250 mm spacing for 120KN disc with hardware set as per technical specification.
Bolted type Double tension fitting for twin moose bundle ACSR conductor with turn buckle for 132 KV Main Bus comprising with D-Shackle socket, Ball link, Yoke Plate, D-Clip and 250 mm spacing for 120KN disc with hardware set as per technical specification.
132 KV Isolator clamp made up of LM-6 aluminium alloy suitable for double Twin conductor with HDG nuts, Bolts and washers of and as per Sample.
132 KV CT clamp made of LM-6 aluminium alloy suitable for Twin Moose conductor and as per Sample.
132 KV CB clamp made of LM-6 aluminium alloy suitable for Twin Moose conductor and as per Sample.
132 KV Post Insulator clamp made Up of LM-6 aluminium alloy suitable for Twin Moose conductor and as per Sample.
Spacer for twin moose conductor for 250mm spacing for 132 KV system complete with hot dip galvanized nut bolt & washers as per Sample.
Opening of all jumpers of ACSR Moose/Zebra conductor from 132 KV main bus bar to bus isolators and Line bay .
Dismantling of existing 132 KV 3phase Main Bus of single ACSR Moose conductor (in 4 Sections) including de-hoisting of disc insulator strings, tension fittings, opening of all bay jumpers, opening of section isolator jumpers etc. along with shifting of conductor/materials from erection site to store of 132 KV sub station Cantt Varanasi.(1 job=one phase per section of bus bar)
Stringing of 132 KV 3 phase Main Bus of twin ACSR Moose conductor (in 4 Sections) including hoisting of disc insulator strings, tension fittings, connecting of all bay jumpers to bus bar, connecting of section isolator by twin moose conductor/Jumpering between two sections etc. along with shifting of conductor/materials(to be provided by department) from store of 132 KV sub station Cantt Varanasi to erection site(1 job=one phase per section of bus bar)
Fixing of rigid spacer clamps at an equal interval between both moose conductors of twin bus bar.
Fixing and tightening of moose/Zebra conductor jumpers by way of cutting, binding, clamping of conductor with suitable spacer/PG clamps from 132 KV main bus to various bus isolator, section isolator, BKR Etc.
M/S P B ENTERPRISES (BID ID -5069823)
M/S SHRI RAMRAJ TRADERS (BID ID -5067822)
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .