Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹20.4 LAccepted-AOC | L1 | Accepted-AOC Accepted being lowest quoted tenderer | |
| 2 | L2₹28.0 L+₹2.5 L (9.83%)Rejected-AOC | L2 | Rejected-AOC Rejected being other than lowest quoted tenderer | |
| 3 | L3₹29.5 L+₹4.0 L (15.7%)Rejected-AOC | L3 | Rejected-AOC Rejected being other than lowest quoted tenderer |
| Sl No | Description | Qty | Unit | Aawadh associates L3 | UJJAWAL ENTERPRISES L2 | Raj Contruction L1 |
|---|---|---|---|---|---|---|
| 1.00 | Excavation in trenches/pits in any type of soft soil not exceeding 1.5 m wide and not exceeding 1.5 m deep and getting out complete all as specified and directed. | 47 | Cum | 142 ₹6,674 Lowest | 150 ₹7,050 | 220 ₹10,340 |
| 2.00 | Returning, filling in with the earth obtained from item No.01 here-in-before including spreading, levelling, watering and well ramming in layers not exceeding 25 cm thick complete all as specified and directed. | 28 | Cum | 85 ₹2,380 | 80 ₹2,240 Lowest | 140 ₹3,920 |
| 3.00 | Removal of surplus excavated soil to a distance not exceeding 50 m and depositing where directed at a level not exceeding 1.5 m above the starting point complete all as specified and directed. | 19 | Cum | 80 ₹1,520 Lowest | 80 ₹1,520 Lowest | 100 ₹1,900 |
| 4.00 | Supply and laying Sub class 'B' bricks(old size) laid flat with width of brick perpendicular to cable length in trenches as cable covers complete all as specified & directed. | 1.5 | Per 1000 Nos | 5,100 ₹7,650 | 5,000 ₹7,500 Lowest | 8,600 ₹12,900 |
| 5.00 | M&L for clean and dry sand (unwashed) in trenches around the cable for cushioning complete all as specified & directed. Note :- Sand cushioning 8cm before laying the cable and 15cm after laying the cable & punned down 18cm,and punned thickness shall be measured and paid complete all as specified and directed. | 14.5 | Cum | 520 ₹7,540 | 500 ₹7,250 Lowest | 800 ₹11,600 |
| 6.00 | Supply, laying, testing and commissioning in pipes/ ducts/ poles/ trenches/under floor/under road XLPE insulated cable screened PVC heavy duty with aluminium conductor,11000 Volt grade(earthed) of cross section area 95 Sqmm,3 core complete all as specified & directed. | 200 | RM | 1,120 ₹2,24,000 | 1,050 ₹2,10,000 | 850 ₹1,70,000 Lowest |
| 7.00 | Supply and laying 80mm bore GI pipe 'light grade' in trenches,under floors,roads,along poles for protection of cables,including sealing ends complete all as specified & directed.
Note:- MS Clamps to be measured and paid under appropriate item. | 20 | RM | 495 ₹9,900 | 500 ₹10,000 | 320 ₹6,400 Lowest |
| 8.00 | M&L for painting of two pole structure of 11m steel poles with cross arms, bracings, clamps of any length and shape for HT overhead line with two coats of aluminum paint including preparation of the existing surface including marking pole numbers in a 15cm dia yellow circle & marking three black & two yellow bands width 30cm by fluoroscent pait, from bottom of pole above coping to 1.5mtr height, complete all as specified and directed. | 4 | Each | 635 ₹2,540 | 600 ₹2,400 Lowest | 800 ₹3,200 |
| 9.00 | M&L for painting of four structure of 11m steel poles with cross arms, bracings, clamps of any length and shape for HT overhead line with two coats of aluminum paint including preparation of the existing surface including marking pole numbers in a 15cm dia yellow circle & marting three black & two yellow bands width 30cm by fluoroscent paint, from bottom of pole above coping to 1.5mtr height, complete all as specified and directed. | 20 | Each | 892 ₹17,840 Lowest | 900 ₹18,000 | 1,450 ₹29,000 |
| 10.00 | Supply and replacement pin type insulator,porcelain,vitreous,white brown or green insulator including one galvanised mild steel spindle,two galvanised iron washers and one galvanised iron nut,150 mm height and 150mm dia suitable for working pressure 11000 volts grade complete all as specified and directed.
Make - Southern insulator/Reychem/Birla 3M/Jaipuria | 5 | Each | 950 ₹4,750 | 1,000 ₹5,000 | 380 ₹1,900 Lowest |
Tender Value
₹30.0 L
EMD Value
₹59,980
Closing Date
8 Nov 2025, 6:00 pmClosed
HQ CWE Prayagraj
HQ CWE New Cantt Prayagraj
PERIODICAL MAINT OF 11 KV DISTRIBUTION TRANSFORMER COMPREHENSIVE REPAIR OF VACUUM CIRCUIT BREAKER VCB TROLLEY BROKEN, 4 POLE AND CONNECTED WORKS IN VARANASI CANTT UNDER GE (EAST) PRAYAGRAJ.
2025_MES_736087_1
82038/E/E8
Open Tender
Civil Works
Item Rate
180 days
Prayagraj
Class D and Category b(ii)
6 documents required · 6 mandatory
₹500
GE (East) Prayagraj
₹59,980
Yes
30 Mar 2026
18 Oct 2025
15 Nov 2025
18 Oct 2025
8 Nov 2025
1 Nov 2025
Amount
Excavation in trenches/pits in any type of soft soil not exceeding 1.5 m wide and not exceeding 1.5 m deep and getting out complete all as specified and directed.
Returning, filling in with the earth obtained from item No.01 here-in-before including spreading, levelling, watering and well ramming in layers not exceeding 25 cm thick complete all as specified and directed.
Removal of surplus excavated soil to a distance not exceeding 50 m and depositing where directed at a level not exceeding 1.5 m above the starting point complete all as specified and directed.
Supply and laying Sub class 'B' bricks(old size) laid flat with width of brick perpendicular to cable length in trenches as cable covers complete all as specified & directed.
M&L for clean and dry sand (unwashed) in trenches around the cable for cushioning complete all as specified & directed. Note :- Sand cushioning 8cm before laying the cable and 15cm after laying the cable & punned down 18cm,and punned thickness shall be measured and paid complete all as specified and directed.
Supply, laying, testing and commissioning in pipes/ ducts/ poles/ trenches/under floor/under road XLPE insulated cable screened PVC heavy duty with aluminium conductor,11000 Volt grade(earthed) of cross section area 95 Sqmm,3 core complete all as specified & directed.
Supply and laying 80mm bore GI pipe 'light grade' in trenches,under floors,roads,along poles for protection of cables,including sealing ends complete all as specified & directed. Note:- MS Clamps to be measured and paid under appropriate item.
M&L for painting of two pole structure of 11m steel poles with cross arms, bracings, clamps of any length and shape for HT overhead line with two coats of aluminum paint including preparation of the existing surface including marking pole numbers in a 15cm dia yellow circle & marking three black & two yellow bands width 30cm by fluoroscent pait, from bottom of pole above coping to 1.5mtr height, complete all as specified and directed.
M&L for painting of four structure of 11m steel poles with cross arms, bracings, clamps of any length and shape for HT overhead line with two coats of aluminum paint including preparation of the existing surface including marking pole numbers in a 15cm dia yellow circle & marting three black & two yellow bands width 30cm by fluoroscent paint, from bottom of pole above coping to 1.5mtr height, complete all as specified and directed.
Supply and replacement pin type insulator,porcelain,vitreous,white brown or green insulator including one galvanised mild steel spindle,two galvanised iron washers and one galvanised iron nut,150 mm height and 150mm dia suitable for working pressure 11000 volts grade complete all as specified and directed. Make - Southern insulator/Reychem/Birla 3M/Jaipuria
M&L for cross arms,bracing,supports,clamps and back plate,fabricated from structural electrical shut down, including nuts, bolts, washers, welding, bending cold or hot,drilling holes for bolts,in any shape or size including two coats synthetic enamel paint over a coat of red oxide primer with & including dismantling and taking out damaged/ruste cross arms,bracings,supports,clamps and back plates from existing poles/dismantled poles/pole structures complete all as specified and directed.
M&L for danger notice plate for HT 25 x20cm x 1.5mm thick mild steel sheet,vitreous enameled white with letters,figures and conventional skull and bones in signal red colour and fixed with MS clamps,bolts and nuts complete all as specified and directed.
Supply and fixing cold shrinkable,straight through joint box for XLPE HT U/G cable,11KV grade suitable for cross sectional area 95 Sqmm 3 core XLPE out door type XLPE cables complete all as specified and directed. Note :- The rates quoted shall be deemed to be include the charges of fault locator machine/eqpt fromUPPCL or any other elect agency as available.
Supply and fixing in replacement cable end termination cold shrinkable type 11KV grade suitable for sizes of XLPE cable 95 Sqmm 3 core outdoor type complete all as specified and directed.
M&L for Calibration of VCB CHECKING (All connections and mechanism) cleaning servicing overhauling,testing complete of 3 phase 11 KV vaccum circuit breakers any make/type as mentioned below :- (a) Taking out incoming and outgoing HT 11 KV 3 core cables from the electric system and checking CTs 03 Nos of each VCB for insulation and saturation calibrating with the help of primary injection & testing kit for primary triping system in presence of Engr-in-Charge/rep of Engr-in-Charge and reconnecting the incoming and outgoing HT cables ,complete all as specified and directed. (b) Inspecting, servicing and testing all connections of control wiring availability of proper D.C. supply,incoming and outgoing connections and tightening them,cleaning the contacts and terminal with CTC solution and using the blower for dusting incl replacement of faulty control fuses,indication lamp & testing for satisfactory operation raising and lowering mechanism in presense of Engr-in-Charge, complete all as specified and directed. (c) Taking out IDMT over current relay 01 Nos and earth fault relay 01 No from the 11KV VCB (2 Nos In each) and calibrating the relays with the help of secondary injection kit and proper setting of relays and refixing back in existing position testing of proper tripping system in presence of Engr-in-Charge complete all as specified and directed. (d) Taking out incoming and outgoing HT 11 KV 3 core cables from the electric system and checking PT 11 KV/110V of each VCB for insulation and accuracy and calibrating the same in presence of Engr-in-Charge/rep of Engr-in-Charge and reconnecting the incoming and outgoing HT cables complete all as specified and directed.
Disconnection & taking out old/defective current transformer (CT) from 11 KV VCB panel and Supply and installation of 11 KV single phase indoor resin cast CT of ratio 400/5-5A class 1.0/ 5P10,burden 15VA complete all as specified and directed. Note:- (i) All the instruments and T & P required for the above jobs shall be arranged by the contractor at site and cost of the deemed to be included in the above rates. (ii) The all above checking ,inspection ,installation and testing work shall be performed by auth HT expert engineer.
Disconnection & taking out old/defective potential transformer (PT) from 11 KV VCB panel and Supply and installation of 11 KV single phase indoor resin cast PT of ratio 11 KV/rt3/110 V/rt3/110V/rt3,Class 0.5-3, Burden 50 VA complete all as specified and directed. Note:- (i) All the instruments and T & P required for the above jobs shall be arranged by the contractor at site and cost of the deemed to be included in the above rates. (ii) The all above checking ,inspection ,installation and testing work shall be performed by auth HT expert engineer.
Taking out trolly from VCB , opening of trolly to clean the parts, cleaning of tank, dismentling of existing unserviceable vaccume interrupter and supply, installation testing of new vacuume interrupter matching to existing one suitable for 11 KV 630 amps HT VCB complete all as specified and as directed.
Supply, installation, Testing & Commissioning of Electronic Numerical self powered programmable type digital Relays having high tourque, low burden ( not more than 5.5 VA) and low over shoot triple pole non directional suitable for 5 Amp current rating and having three over current and one earth fault elements with over current IDMT/ definit time and instant trip, range 20% to 200% in step of 1% per phase and earth fault range of 10% to 80% fault and time setting of 3.0 seconds to 10 times of current setting in steps of 0.1 seconds and accuracy of class 5 confirming to IS 3231 of 1965 including 4.5 volt alkaline battery, flush pattern with accessories duly connected with trip and alarm system - 01 No complete all as specified and directed. Note: The contractor has to visit the site to check the existing relay & wiring of 11 KV VCB panel for installation of Microprocessor based relay.
Dismantling of existing unserviceable bus bar spout after disconnecting all incoming and outgoing connections and S/F new bus bar spout of 11 KV 630 Amps VCB matching to existing one including all incoming and outgoing connection complete all as specified and directed.
Supply and Fix in replacement charging gear for crompton/ABB make trolly mechanism 11 KV 630 Amps VCB, complete all as specified & directed
Supply & fix VCB Tulip contacts male & female patrs for 630A VCB of existing make & model complete all as specified & directed
Supply and Fix in replacement operating mechanism for breaker 11 KV 630 Amps VCB of make crompton/ABB as per required make & model complete all as specified & directed
Supply and Fix in replacement teflon hexagonal interlocking bush to complete interlocking with strip complete all as specified & directed as per sample
Supply and Fix in replacement of push button complete all as specified & directed as per sample
Supply and Fix in replacement ON/OFF Indicator complete all as specified & directed as per sample
M&L for replacing of phase indicator light LED type for panel in three colours ( R,Y,B) complete all as specified and directed.
S&F in repairs of motor & gear assembly 220 volts AC/DC or as per model suitable for 630Amps HT VCB as per existing make and model and directed.
Supplying, fixing, testing and commissioning of digital electronic volt meter 0-500 V range suitable for LT 415 Volts panel flush pattern square type 96 Sqmm with adopter complete with button including taking out old unserviceable Volt Meter all as specified and directed. Make: ENERCON/AE or of equivalent. Note :- The rate quoted shall be deemed to be include the following:- (i) Control wiring for auxiliary supply 440/230 Volts AC if required. (ii) Cutting the sheet of the panel suitable for fixing the voltmeter. (iii) Calibration and testing the meter.
M&L for checking (All connections and mechanism) cleaning servicing overhauling,testing complete of 3 phase 11 KV Ring main unit any type/make outdoor type respectively as mentioned below :- (a) Taking out incoming and outgoing HT 11 KV 3 core cables from the electric system and checking CTs 03 Nos of each breaker for insulation and saturation calibrating with the help of primary injection & testing kit for primary triping system in presence of Engr-in-Charge and reconnecting the incoming and outgoing HT cables complete of panels ,complete all as specified and directed. (b) Inspecting, servicing and testing all mechanical & electrical parts and the connections of control wiring availability of proper DC supply and AC supply,incoming and outgoing connections and tightening them,cleaning the contacts and terminal with CTC solution and using the blower for dusting testing it for satisfactory operation raising and lowering mechanism in presense of Engr-in-Charge complete all as specified and directed. (c) Taking out existing over current relay 02 Nos and earth fault relay 01 No from the 11KV breaker B (3 Nos In each) and calibrating the relays with the help of secondary injection kit and proper setting of relays and refixing back in existing position testing of proper tripping system in presence of Engr-in-Charge complete all as specified and directed. Note : (i) All the instruments,primary and secondary injection kit and T&P required for the above job shall be arranged by the contractor at site and cost of the deemed to be included in the above rates. (ii) All the test record shall be mentioned and signed by the testing engineer and contractor and Engineer-in-Charge. (iii) The above work shall be performed by HT expert/ Engineer.
Supply and fix in replacement only Battery for RMU, maintenance free, 12 V, 60 AH including taking down unserviceable battery any type complete all as specified and directed.
Supply and fix in replacement Printed circuit board for RMU scada operation suitable for 630Amps HT as per existing make and model and complete all as specified and directed.
M&L for filteration and centrifuging of transformer oil complete all as specified and directed. Note :- Centrifuging machine to be arranged by contractor and its cost shall be deemed included in the quoted rate. BDV of test to be noted before and after centrifuging. Centrifuging and cleaning will be carried on until BDV of 50KV with 2.5mm gap . Heaters not less than 5KW should be used. Oil required for top up or replacement will be measured separately
M&L for transformer oil for top up in transformer. Note : Sealed container only will be brought at site with minimum BDV 60 KV complete all as specified and directed. Make : Transol,Power Oil
Supply & Replacement of silica gel breather of transformer 11/0.433 KV of capacity 63-160KVA complete all as specified and directed.
Supply & Replacement of silica gel breather of transformer 11/0.433 KV of capacity 200-350KVA complete all as specified and directed.
Supply & Replacement of silica gel breather of transformer of transformer 11/.433 KV of capacity 415 -500 kVA complete all as specified and directed.
Supply & Replacement of silica gel only in transformers etc of any capacity complete all as specified and directed.
Supply & Replacement of LT bushing of transformer 11/0.433 KV of capacity 63-160KVA complete all as specified and directed.
Supply & Replacement of HT bushing of transformer 11/0.433 KV of capacity 63-160KVA complete all as specified and directed.
Supply & Replacement of LT bushing of transformer 11/0.433 KV of capacity 200-500KVA complete all as specified and directed.
Supply & Replacement of HT bushing of transformer 11/0.433 KV of capacity 200-500KVA complete all as specified and directed.
Taking down the defective unserviceable transformer from existing site from pole and Sub Stn with the help of man power & chain pully block or by crane etc including dieconnecting all electrical and mechanical connections from the site and carrying to workshop for repair and replacement of old burnt u/s item including transporting of capacity 63 KVA to 250 KVA(including 250 KVA) including transporting back after repair to the site where recieved complete all as specified and directed.
All as per srl item No. 44 above here in before but for 300 KVA to 500 KVA.
Opening Dismantling the transformer of capacity 100 KVA to 250 (including 250 KVA capacity of trs ) KVA by lifting the top cover taking out the HT/LT core and draining out the transformer oil in barral including cleaning the transformer chamber (body) inside and out side throughly with emery paper and cloth than checked the winding and other worn-out parts such as HT/LT coils silicor stamping and other connected items as Tap-changer, breather assembly etc and replacement of HT and LT coil and connected to existing serviceable strip by jointing with soldring and re insulated of cotton tape over strip including using insulating material like varnish to limb coil fire proof type and sleeves etc by drying and baking of Insulating material in heating chamber in adequate temprature Reassenbling the transformer LT/HT connection with help of soldering. Testing of transformer after reassembly complete testing of transformer after repair incl painting to the transformer with super enammed paint all as specified and directed. Note :- HT/LT coils and other connected items shall be measured & paid seperately.
All as per srl item No. 46 above here in before but for 300 KVA to 500 KVA complet all as specified and directed .
M&L for winding HT coil with DPC or enamelled copper wire/ of existing size & guage winding wire for winding the transformer coil incl insulating material complete all as specified and directed .
M&L for LT coil winding with DPC or enamelled copper wire strip of existing size & guage winding for winding the transformer coil LT coil all as specified and directed .
Supply & replacement of HT/LT bush Insulator complete with rod as per existing material & size and nut suitable for indoor/outdoor type transformer 63 KVA complet all as specified and directed .
All as per srl item No. 50 above but 100 KVA to 250 KVA.
All as per srl item No. 50 here in before but 300 KVA to 500 KVA.
Supply & replacement of tap changer for adjusting the voltage with brass parts as per sample of existing for indoor/ outdoor type transformer 63 KVA all as specified and directed.
All as per srl item No. 53 above but 100 KVA to 250 KVA.
All as per srl item No. 53 here in before but 300 KVA to 500 KVA.
M&L for painting of Transformers of any capacity & any size complete, on all four sides incl top portion of transformer with one coat of synthetic enamel paint after removing dust, dirt & preparation the surface by scratching with emery paper for painting incl transformer details all as specified & directed.
M&L for shifting of transformer 11/ 0.433 KV of any capacity from Main Power house to required location at the AGE MES Varanasi station incl. making all HT/ LT electric connections and disconnectiong all HT / LT connections of faulty transformer of any capacity and restore the electric supply of affected area complete all as spd and directed by Eng-in-charge.
M&L for periodical cleaning the area around all the sub station of electrical installation all by cutting/removing unwanted grass and grass bushes including herb/shrub on pole & cutting, treaming & prooning of tree branches complete all as specified and directed. Note : Tools will be provided by the Contractor.
M&L for earthing complete with galvanised steel earth plate electrode 600x600x6 mm thick buried directly in ground (earth pit not less than 2.25m deep below GL with top edge of plate not less than 1.50 m below normal ground level) connected to galavanised earth lead strip 25mm x 4 mm (7.5m) as means of bolts, nuts, check nuts and washer besides brazing at all joints as shown on drawings and including excavation, earth work, GI pipe (ISImark) light grade 40mm bore for protection of GI strip from earth electrode to and including the earth test point, supplying and laying charcoal dust, common salt, PCC 1:3:6, type C-1(using 20 mm graded crushed stone aggregate ) chamber and mild steel angle iron frame 40 x 40 x 3 mm and 40 mm thick pre-cast RCC cover 1:2:4 , type B-1(using 20 mm graded crushed stone aggregate ) reinforced with 8 mm dia TMT bars @ 75 mm C/C both ways with mild steel handle 12 mm dia, PGI funnel and wire mesh, 20 mm dia GI pipe light grade(ISI marked) for watering all as shown in electrical plate No 3 of SSR Part-I and connected to earth test point including testing & taking down of old/ ineffective earthing complete all as specified and directed. Note:- The rates quoted shall also deemed to include the cost of Earth test point and earth wire and protection pipe upto 7.5 meter beyond the earth plates electrode.
M&L for repair of earth pits at substation and of lightining protection by cleaning in and around the chamber,repair /replacement of MS chamber cover /PCC cover slabs ,removing wild growth needs from the area around earth chamber ,provn of salt water in to earth pits ,repair /replacement of funnel ,checking of earth contunity connecting checking and recording of earth results and painting the results and date of testing etc on the chamber , complete all as specified and as directed.
Supply and installation,testing and commissioning of HT 11 KV, 3 phase, 50 Hz ,totally enclosed metal clad switchgear complete with Vacuum circuit breaker having rupturing capacity upto 350 MVA , overload and earth fault protection, ammeter, voltmeter and of rating upto 630 Amp complete all as specified and directed. The unit shall include the following with all necessary standard fitting required at site complete all as specified and as directed. (i) Vaccum circuit breaker fitted with vaccum interrupters, triple pole metal clad indoor type , totally enclosed & fully interlocked draw out type VCB as per IEC 62271-100/200/IS 13118 including coupling with existing VCBs with new coupling arrangement all as specifed and directed. (ii) Single break trip breaker with motor operated spring charged mechanism,mounted on a truck carriage/ cassette, complete with self contained operated fully interlockedrack in & Rack out mechanism ON /OFF Indicator with hand trip device.
(iii) Spring operated Motor(230 V AC ) shunt trip coil (30V DC) & Auxillary switch of 4 NO + 4 NC, manually operated spring closing mechanism complete auxillary switches trunk type with ON/OFF indicator of rupturing capacity of 350MVA and rating up to 630 Amp as mentioned with one set of triple pole IDMT numerical relay with three overcurrent relay 50% to 200 % in step of 25 % in range of 5 amps and one ,earth fault relay 20 % to 80% in steps of 10% range 5 Amps. (iv) Fully compartmentalised sheet steel enclosure floor mounting type with automatic safety shutters,independent pressure discharge flaps with heat shrinkable PVC sheeves. (v) The system shall be 11 KV ,630 Amps ,18.4 KA for 3 sec and incomer cum outgoing feeder with line PT. (vi) Degree of protection shall be IP 42. (vii) Equipment shall be horizontal draw out horizontal isolation. FACTORY INSPECTION :- (i) A factory inspection program will be scheduled by contractor before supply of VCB and no extra cost admissible on this account. Before supply of VCB contractor shall inform to Accepting officer through GE for factory inspection and the representative of Accepting officer shall visit the factory to ascertain the quality of VCB. (ii) Unit to be used as outgoing at sub stn No 1 and necessary fixing arrangement shall be made by contractor, nothing extra shall be paid on this account and shall be deemed in quoted rates.
M&L for old size brick work with fly ash bricks straight or curved on plan to any radius half brick thick wall built in CM (1: 4), complete all as specified and directed.
M&L old size brick work with fly ash bricks straight or curved on plan exc 6 m mean radius built in CM 1: 6 complete all as specified and directed.
Dismantling brick tiles any size laid bedded and pointed in any mortor complete all as specified and directed.
Demolition of mud in roofs any thickness and in any position and leaping over roof terrace ,removing the demolished material to a distance exc 250 m & n exc 500 m and depositing where directed at a level n exc.1.5 m above starting point, complete all as specified and as directed.
M&L for PCC 1:2:4 type B0 (using 12.5 mm graded crushed stone aggregate) as in roof padding, coping , kerb etc finishing the surface fair & even. complete all as specified and directed.
M&L for 10mm thick in CM 1:3 rendering on fair faces of concrete surfaces /roof top mixed with liquid water proofing compound finished even and smooth without using extra cement complete all as specified and directed. Note :- Liquid WPC shall be measured and paid separately.
M&L preparation of newly plastered surfaces of roof including cleaning the surfaces by using wire brush/ pressure hose and applying high performance polyurethene liquid membrane waterproofing coating in two coats @ 1.5 Kg/Sqm/ 2 coats spray/ brush applied, with an elongation of 300% to 700% and tensile strength of not less than 3 N/Sqmm as per ASTM D412 and ASTM D2370, crack bridging ability of 3.5mm as per ASTM C1305, shore a hardness of not less than 60 as per ASTM D2240. The item includes applying epoxy primer @ 0.15Kg/Sqm and a geotextile of 40 GSM to be applied over first coat while first coat is still wet, complete as per manufacturer's instrructions complete all as specified and directed. Note:- The contractor shall submit a gurantee of 10 years the date of completion of work for waterproofing treatment alongwith manufacturer's guarentee. The amount of Rs. 40 (Forty) oer Sqm and min of Rs. 4000/- for waterproofing treatment shall be withheld from contractor's final bill till the expiry of gurantee period. The contractor at his own option may furnish fix deposit receipt pledged in favour of GE(I) Kanpur against gurantee money. 2. The water proofing shall be carried out by authorised applicator of manufacturer. The name of applicator shall be got approved from GE before commencement of work.
Demolition of cement Concrete in ground floors and pavings not exc 15 cm thickness (below or above ground level) incl chequered tiling and Paver blocks complete all as specified and directed.
M&L for 75 mm thick PCC 1:3:6 type C1 (using 20 mm graded stone aggregate) as in plinth protection, finishing cement concrete surface even and fair complete all as specified and directed.
M&L for 75 mm thick cement concrete type-C-2, 1:3:6 using 40mm graded crushed stone aggregate finished cement concrete surface even and fair as in floor complete all as specified and directed.
Taking down cement plaster on brick or stone walls or ceiling etc including racking out joints, hacking for key, scrubbing down with water etc. complete all as specified.
M&L for rendering 15 mm thick on fair faces of brick work in CM in 1:4 finished even and fair and mixing with water proofing liquid as per manufacturer instruction (but excluding the cost of water proofing liquid ) external surface complete all as specified and directed.
Supply only Liquid water proofing compound of approved make.
M&L for rendering 10mm thick in CM (1:6) on Brick/ Conc surface finished even and fair on internal surfaces of wall complete all as specified and directed.
M&L for rendering 5 mm thick in CM 1:3 on concrete surface in ceiling complete all as specified and directed.
M&L for preparation of new plastered surface and applying two coat of oil bound distemper on walls over a coat of primer incl 3 mm thick wall care putty complete all as specified and directed.
M&L for preparation of old plastered surface and applying two coat of oil bound distemper on walls over a coat of primer and 3 mm thick wall care putty including complete removal of existing treatment complete all as specified and directed.
Complete removal of existing treatment on wall/roof projections including facia, cornices etc by scrapping with mechanical sander (having mechanical vacuum mechanism) with sanding pad of appropriate grit to make surface clean, free from dust, loose paint etc by skilled labour complete all as specified and directed.
M&L for 1mm thick wall care putty with one coat of acrylic water based exterior grade primer @0.9 ltrs (undiluted)/10sq mtrs diluted with water 1:1 ratio to be applied with fully automatic airless spray machine of paint application with a flow speed of min 1 ltr per minute having a pressure of 3300 PSI. Allow 6-8 hrs to dry the surface for painting of subsequent coats, complete all as specified and directed. Make of Manufacturer : ASIAN/BERGER/NEROLAC or equivalent make as mentioned in appx B
M&L for two coats of water based premium acrylic smooth exterior emulsion of approved coulur with silicon addictive & color stay technology excellent dirt pick up resistance with low VOC less than 50 gram/ltr as per the LEEDS specification anti algal propertiess in two coats @ 1.79 ltrs (undiluted)/10sq mtrs diluted with water as per manufacturer instruction applied over priming coat with fully automatic airless spray machine of paint application with a flow speed of min 1 ltr per minute having a pressure of 3300 PSI and capable of operating single spray gun with a max material hose length of 30 m. the spray machine should be of reputed paint manufacturer as mentioned in PS and accessories for applying emulsion should be able to spray in hard to reach areas and penetration of emulsion on the surface using auto roller for making the surface uniform complete all as specified and directed. Allow 6-8 hrs to dry the surface for painting of subsequent coats complete all as specified and directed. Make of Manufacturer : ASIAN/BERGER/NEROLAC or equivalent
M&L for preparation of new plastered surfaces of ceiling and applying three coats of white wash complete all as specified and directed.
M&L for preparation of old surfaces of ceiling and applying two coats of white wash complete all as specified and directed.
Taking down chowkhat or frame with shutter (without taking off shutter from the frame) Area not exc 1.5 Sqm each complete all as specified and directed.
S&F Stainless steel wire cloth, 0.36mm nominal dia of wire and average width of aperture 1.40mm and fixed with stainless steel wire staples complete all as specified and directed.
M&L for preparation of old steel surfaces of any description over 10 cm width or girth and applying two coats of synthetic enamel paint complete all as specified.
M&L for preparation of old wooden surfaces of any description over 10 cm width or girth and applying two coats of synthetic enamel paint complete all as specified.
S&F Powder Coated aluminium frame for doors, windows, ventilators powder coated (thickness of powder coating not less than 50 micron) with one or more rebates including jointing cleat for fixing etc complete all as specified and directed.
S&F Powder coated aluminium (minimum thickness of powder coating 50 micron) for shutters of doors, windows & ventilators including providing and fixing hinges/ pivots and making provision for fixing of fittings wherever required including the cost of EPDM rubber/neoprene gasket required with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS: 733 and IS:1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing/ paneling, C.P. brass/ stainless steel screws all complete as per architectural drawings and the directions of Engineer-in-charge. Note:- 1. The rate is inclusive of all fixings of builders hardware such as hinges, bow handles, locking arrangements rubber beading for fixing of glass etc complete all as directed by Engr-in-Charge. 2. Glass and wiremesh shall be measured and paid separetely
M&L for 4.8 mm thick frosted sheet glass ordinary quality and glazing with beading n exc 0.5 sqm in each pane complete all as specified and as directed.
M&L for 4.8 mm thick sheet glass ordinary quality and glazing with aluminium beading n exc 0.5 Sqm in each pane complete all as specidfied and as directed.
Dismantling wrought iron or mild steel work of any description not otherwise provided for. complete all as specified and directed.
S&F Rolled MS Joist, channel, angle, or tee sections, fixed independently, without connection plate, etc. (cut to ordinary lengths i.e. within 20 mm of the length indicated) Fe 410 -W (Gde- E-250) quality A, complete all as specified and directed.
Demolition of brick work or stone boulder masonry laid dry complete all as specified and directed.
UJJAWAL ENTERPRISES (BID ID -3474736)
Aawadh associates (BID ID -3475293)
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Tendernotice_1.pdf
PDF • 0.49 MB
Tenderdocument.pdf
Tender Documents • 0.73 MB
Makes.pdf
Additional Documents • 0.53 MB
Specialcondition.pdf
Additional Documents • 0.49 MB
Particularspecifications.pdf
Additional Documents • 0.57 MB
BOQ_824231.xls
BOQ • 0.41 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .