Loading…
Loading…
Tender Value
₹32.3 L
EMD Value
₹64,600
Closing Date
10 Jul 2026, 3:30 pmClosed
No
No
Single Packet System
Normal Tender
No
Not Applicable
Lowest to Highest
60 days
Expenditure
Capital (Works)
Above/Below/Par
DRM/WORKS
26 conditions · 3 needing a document upload
"The said suppliers of goods and/or services would be subject to GST Act and Rules as applicable from time to time. Tenderers are requested to submit their offers as per GST Tax regime. All the bidders/tenderers should ensure that they are GST compliant and their quoted tax structure/rates are as per GST Law"
Successful tenderers are required to submit the number of labour to be employed for this particular work. Also the list showing names, along with all other details, of male and female workers employed in this work, should be submitted to office, at the time of submitting performance guarantee and before executing contract agreement. They should also ensure that 1) The payment to the contract labour should be made through bank/cheque. 2) Identity Cards should be issued to all contract workers. 3) Necessary steps should be taken to deduct provident fund from the payment made to contract labour and ensure that the same is credited to their Provident Fund account. 4)Medical facilities from ESI should be ensured, if applicable.
Please enter the percentage of local content in the material being offered. Please enter 0 for fully imported items, and 100 for fully indigenous items. The definition and calculation of local content shall be in accordance with the Make in India policy as incorporated in the tender conditions.
Tenderers are required to submit a copy of cancelled cheque in order to facilitate the payments regarding refund of EMD etc. in their proper accounts.
Format of Declaration and Self certificate in case of small value tenders, (i.e. tender value less than Rs. 50 lakhs), is being attached in Documents Tab. Tenderers should download, fill and submit both the proforma along with their offer, failing which offer may be rejected summarily. ( Click here to download Format)
In addition to latest provisions of GCC, and all contents of tender documents, all other latest instructions of Railway Boards issued vide various letters received from time to time on concerned matters and related to tender, will also be applicable for the tenders as per necessity and tenderers have to co-operate with Railways and ensure the compliance
Indian Railways Standard General Conditions of Contract, April 2022 (GCC, April 2022) has been introduced and available on website with all correction slips issued up to date for inviting tender and same will be applicable for this tender. Advance Correction Slip No. 1, 2, 3, 4, 5, 6, 7, 8, 9, 10 and 11 to Indian Railways Standard General Conditions of Contract, April - 2022 circulated by the Railway Board vide letter No. 2022/CE-I/ CT/GCC-2022/Policy dated 14.07.2022, 13.12.2022, 26.04.2023, 07.08.2023, 20.10.2023 , 21.12.2023, 25.09.2024, 20.12.2024, 09.01.2025,04.03.2025 and 13.03.2026 are applicable to this tender.
I/We agree to carry out all works with use of modern equipments of required capacity for the work without extra payment. The decision of railway engineer shall be final and binding in this regard.
It is the responsibility of contractor to arrange the payment of the labour employed for the work through bank and to deduct PF as per the provisions of Minimum Wages Act.
The quantities shown above are approximate and to give a general guideline. Railway reserves a right to increase, decrease or to delete any of the items mentioned in schedule.
As per ACS 1 to GCC April 2022, issued vide Railway Board's letter dt. 14.07.2022, PVC Clause shall be applicable only in tenders having advertised value above Rs. 2 Crores provided to the provisions as per clause 46A-1. Tenderers should take a note and quote their rates accordingly.
In case Civil work tenders, the quantity of cement required in the items where necessary, will be used by the contractor on the same rates as accepted in tender, as per the quantity mentioned against each item in USSOR/DSR, though not mentioned in tender schedule.
Tenderers are advised to quote their rates including all type of taxes and levies etc. to be paid by them. Any extra payment will not be made on account of taxes/Levies etc., in excess of Contract Agreement Value,
In case of submission of Bid Security in the form of Bank Guarantee, a scanned copy of Original BG valid for a period of 90 days beyond the validity period of tender, and addressed in favour of Sr. DFM/WCR/BPL, shall be uploaded on IREPS portal while applying for tender. And As per ACS 2 to GCC April 2022, circulated vide Railway Board letter dt. 13.12.22, original BG should be delivered in person to the Concerned Official in Office before closing date for submission of bid (i.e. Excluding the last date of submission of bid) without fail. Any failure in this connection shall lead to summary rejection of bid.
Maintenance Period for this work will be 18 Months after successful completion of work.
Annexure V (A) certificate attached in technical eligibility criteria: Clarification Regarding submission of Annexure-V(A) asper NIT: In case of Partnership firm/Joint Venture (JV) / Hindu Undivided Family (HUF) / Limited Liability Partnership (LLP) etc, the Annexure-V(A) must be submitted in the format as given in technical eligibility criteria link, by each partner in case of partnership firm / each member in case of HUF/ each JV member through their authorized signatory in case of Joint Venture firm as self-certification in individual capacity (not as bidder). Nonsubmission of the certificate, or submission of certificate either not properly filled in, or in a format other than the prescribed format shall lead to summary rejection of offer. For avoidance of doubt it is to make clear that this self-certification as they are individually not blacklisted/debarred......, shall be submitted by1. Each partner in case of partnership firm/Limited Liability Partnership (LLP) 2. Each member in case of HUF. 3. Each JV member through their authorized signatory.
Bhopal Division- Centralized Medical Gas Pipeline System at Nishatpura (Divisional Railway Hospital) in connection with Upgradation of medical equipments under ADEN(Works)Bhopal.
WCR-BPL-W-26-27-HQ-13-50
WCR-BPL-W-26-27-HQ-13-50
Open
Works - General
4 Months
Bhopal, Madhya Pradesh
₹0
₹64,600
10 Jul 2026
16 Jun 2026
26 Jun 2026
27 items across 1 schedule · ₹32,28,002.1 total
| # | Description | Unit | Qty | Rate | Amount |
|---|---|---|---|---|---|
| 1 | NS-01). MEDICAL GAS SYSTEM OXYGEN SYSTEM:- Supply, installation, testing & commissioning of Oxygen Manifold: Main 10+10 Cylinder Oxygen Manifold-WALL MOUNTING TYPE GAS MANIFOLD FABRICATED WITH 5/8"X 15 SWG COPPE PIPE AS PER BS EN 1057 & BRASS BLOCKS AS PER IS 319 EQUALLY SPACED AT 250 MM FITTED ON DULY POWDER COATED MS FRAME (95 X 45) HYDRAULICALLY TESTED AT 300 BAR WITH HIGH PRESSURE NON RETURN VALVE, 1.25 METRE LONG 5/16" X 16G COPPER TAIL PIPE TESTED AT 300 BAR & MIDDLE FRAME FOR OXYGEN | Set | 1.00 | 1,15,640 | 1,15,640 |
| 2 | NS-02). Supply, installation, testing & commissioning of Emergency Oxygen manifold System :5+5 Cylinder Oxygen Manifold -WALL MOUNTING TYPE GAS MANIFOLD FABRICATED WITH 5/8"X 15 SWG COPPER PIPE AS PER BS EN 1057 & BRASS BLOCKS AS PER IS 319 EQUALLY SPACED AT 250 MM FITTED ON DULY POWDER COATED MS FRAME (95 X 45) HYDRAULICALLY TESTED AT 300 BAR WITH HIGH PRESSURE NON RETURN VALVE, 1.25 METRE LONG 5/16" X 16G COPPER TAIL PIPE TESTED AT 300 BAR & MIDDLE FRAME FOR OXYGEN/complete along with double stage Regulator. | Set | 1.00 | 56,640 | 56,640 |
| 3 | NS-03). Supply, installation, testing & commissioning of Oxygen Control Panel. Control Panel (Fully automatic changeover panel) The Control pannel shall be of fully integrated type with all saftety futures inbuilt for high pressure and high flow upto 1350 Itrs/min Oxygen system The Pannel shall have the necessary instruments, gauges, etc. Pressure for manifold system Green signal for Normal Pressure & Red signal for low pressure. Left bank Green signal for Normal Pressure & Red for Low pressure. In Right bank Green signal for Normal Pressure & Red for Low pressure. Main Line Green signal for Normal Pressure & Red for Low pressure, | Numbers | 1.00 | 1,47,500 | 1,47,500 |
| 4 | NS-04). Supply, installation, testing & commissioning of Oxgyen gas Metal outlets, gas outlet point for oxygen outlet points Conforms to: BS 5682: 2015, IS/ISO 9170-1:2017, IS/ISO 7396- 1:2016 A1: 2017, HTM 02-01. Totally leak proof, safe & easy to operate having non interchangeable specific gas/vacum probes equipped with non return valves to facilitate on sevicing and repair. indentfication with colour for specific gas/vacum beside name of the gas is punched on its face. BS Type. | Numbers | 26.00 | 3,274.5 | 85,137 |
| 5 | NS-05). Supply, erection, installation, testing & commissioning of anodised aluminium body & control knob oxygen flow meter with Humidifier Bottle. 0-15 L/min standard flow rate. Conforms to: IS/ISO 15002 : 2008, IS/ISO 7396-1:2016 + A1: 2017, HTM 02-01. | Numbers | 15.00 | 1,327.5 | 19,912.5 |
| 6 | NS-06). VACUUM CENTRAL SYSTEM Supply, installation, testing & commissioning of VACCUM SUPPLY SYSTEM COMPLETELY IN ALL RESPECTS make ingersoll rand/Anest Iwata/: The pump installation shall be duplex system consisting of 2 (1W+1S BY) .5 HP having 1699 Ipm. | Set | 2.00 | 1,85,850 | 3,71,700 |
| 7 | NS-07). Supply, installation, testing & commissioning of Vacuum storage reservoir tankr Capacity: 1000 liters water capacity Vacuum storage reservoir tank, Rated for full vacuum services with the storage capacity of approx 1000 Liter or as per standard recommendation. It should be equipped with an vacuum gauge and provision for manual draining by pass valve. The inside of the tank should be coated with a two- component coating to provide a hard, durable lining for rust protection. | Numbers | 1.00 | 1,00,300 | 1,00,300 |
| 8 | NS-08). VACUUM BACTERIAL FILTERATION: Suitable Medical Vacuum filters are used for removal of bacteria & other contamination from the suction side of vacuum pumps, preventing infection of pump and the atmosphere. | Numbers | 1.00 | 2,65,500 | 2,65,500 |
| 9 | NS-09). Supply, erection, installation, testing & commissioning of Vacuum Metal Gas outlets, gas outlet point for Vacuum outlet points Conforms to: BS 5682: 2015, IS/ISO 9170-1:2017, IS/ISO 7396-1: 2016+A1:2017, HTM 02-01, leak proof safe & easy to operate having non- interchangeable specific gas/vacum probes Equipped with non return valve to facilitate on servicing & repair. identification with colours for specific gas/vacum beside name of the gas is punched on its face. Double locking system. | Numbers | 19.00 | 3,274.5 | 62,215.5 |
| 10 | NS-10). Supply installation & testing commissioning of ward vaccum unit with Polycorbonate jar capacity of 700 ml. | Numbers | 15.00 | 2,906.34 | 43,595.1 |
| 11 | NS-11). Supply, installation, testing & commissioning of THEATRE SUCTION TROLLEY WITH S.S. STAND, PLASTIC BASE, VACUITY SUCTION REGULATOR & 2200 ML ALL POCYCARBONATE SUCTION LOCK JARS | Numbers | 2.00 | 23,895 | 47,790 |
| 12 | NS-12). Supply, installation, testing & commissioning of Medical grade copper tube/pipe the pipe distribution system shall use copper pipe manufactured from phasphorous die oxidiesd non arsenical copper to BS EN 1412:1996 grade CWO24A (Cu-DHP), manufactured to metric outside diameters and having mechanical properties in accordence with BS EN 13348:2016 in either R250 (half hard) or R290 (hard), degreasing of pipe shall be such that there is less than 20mg/m2 (0.002mg/cm2) of hydrocarbon on the degreased surface when tested by the method specified BS en 13348:2008. The copper pipes should be Lloyd's/Bsi/TUV tested & certifief for the chemical properties as per EN 13348:2016 standard. Copper Pipes of 12mm ODX 0.7mm thk | Metre | 120.00 | 483.8 | 58,056 |
| 13 | NS-13). Supply, installation, testing & commissioning of Medical grade copper tube/pipe the pipe distribution system shall use copper pipe manufactured from phasphorous die oxidiesd non arsenical copper to BS EN 1412:1996 grade CWO24A (Cu-DHP), manufactured to metric outside diameters and having mechanical properties in accordence with BS EN 13348:2016 in either R250 (half hard) or R290 (hard), degreasing of pipe shall be such that there is less than 20mg/m2 (0.002mg/cm2) of hydrocarbon on the degreased surface when tested by the method specified BS en 13348:2008. The copper pipes should be Lloyd's/Bsi/TUV tested & certifief for the chemical properties as per EN 13348:2016 standard. Copper Pipes of 15mm ODX 0.9mm thk | Metre | 265.00 | 755.2 | 2,00,128 |
| 14 | NS-14). Supply, installation, testing & commissioning of Medical grade copper tube/pipe the pipe distribution system shall use copper pipe manufactured from phasphorous die oxidiesd non arsenical copper to BS EN 1412:1996 grade CWO24A (Cu-DHP), manufactured to metric outside diameters and having mechanical properties in accordence with BS EN 13348:2016 in either R250 (half hard) or R290 (hard), degreasing of pipe shall be such that there is less than 20mg/m2 (0.002mg/cm2) of hydrocarbon on the degreased surface when tested by the method specified BS en 13348:2008. The copper pipes should be Lloyd's/Bsi/TUV tested & certifief for the chemical properties as per EN 13348:2016 standard. Copper Pipes of 22mm ODX 0.9mm thk | Metre | 275.00 | 1,073.8 | 2,95,295 |
| 15 | NS-15). Supply, installation, testing & commissioning of Medical grade copper tube/pipe the pipe distribution system shall use copper pipe manufactured from phasphorous die oxidiesd non arsenical copper to BS EN 1412:1996 grade CWO24A (Cu-DHP), manufactured to metric outside diameters and having mechanical properties in accordence with BS EN 13348:2016 in either R250 (half hard) or R290 (hard), degreasing of pipe shall be such that there is less than 20mg/m2 (0.002mg/cm2) of hydrocarbon on the degreased surface when tested by the method specified BS en 13348:2008. The copper pipes should be Lloyd's/Bsi/TUV tested & certifief for the chemical properties as per EN 13348:2016 standard. Copper Pipes of 28mm ODX 0.9mm thk | Metre | 150.00 | 1,368.8 | 2,05,320 |
| 16 | NS-16). Supply, installation, testing & commissioning of Medical grade copper tube/pipe the pipe distribution system shall use copper pipe manufactured from phasphorous die oxidiesd non arsenical copper to BS EN 1412:1996 grade CWO24A (Cu-DHP), manufactured to metric outside diameters and having mechanical properties in accordence with BS EN 13348:2016 in either R250 (half hard) or R290 (hard), degreasing of pipe shall be such that there is less than 20mg/m2 (0.002mg/cm2) of hydrocarbon on the degreased surface when tested by the method specified BS en 13348:2008. The copper pipes should be Lloyd's/Bsi/TUV tested & certifief for the chemical properties as per EN 13348:2016 standard. Copper Pipes of 35mm ODX 1.2mm thk | Metre | 140.00 | 2,171.2 | 3,03,968 |
| 17 | NS-17). Supply, installation, testing & commissioning of Area Alarm panel & Area Valve Box, Conforms to: IS/ISO 7396-1 : 2016 + A1 : 2017, HTM 02-01 Part A IS/ISO IEC 60601-1 : 2015 + A1 : 2020 Area alarm 2 Gases (1gas + 1 Vaccum) | Numbers | 4.00 | 22,420 | 89,680 |
| 18 | NS-18). Supply, installation, testing & commissioning of Area Alarm panel & Area Valve Box, Conforms to: IS/ISO 7396-1 : 2016 + A1 : 2017, HTM 02-01 Part A IS/ISO IEC 60601-1 : 2015 + A1 : 2020 Area Valve Box 2 Gases (1gas + 1Vac) | Numbers | 4.00 | 17,110 | 68,440 |
| 19 | NS-19). Supply, installation, testing & commissioning of Master Alarm for Manifold and Plant Room. | Numbers | 1.00 | 47,200 | 47,200 |
| 20 | NS-20). Supply, installation, testing & commissioning of ine Isolation valves Confirmed to BS EN 331: 2015, IS/ISO 7396- 1:2016+A1:2017 12mm line isolation valve | Numbers | 21.00 | 1,593 | 33,453 |
| 21 | NS-21). Supply, installation, testing & commissioning of ine Isolation valves Confirmed to BS EN 331: 2015, IS/ISO 7396- 1:2016+A1:2017 15mm line isolation valve | Numbers | 26.00 | 1,947 | 50,622 |
| 22 | NS-22). Supply, installation, testing & commissioning of ine Isolation valves Confirmed to BS EN 331: 2015, IS/ISO 7396- 1:2016+A1:2017 22mm line isolation valve | Numbers | 14.00 | 2,655 | 37,170 |
| 23 | NS-23). Supply, installation, testing & commissioning of ine Isolation valves Confirmed to BS EN 331: 2015, IS/ISO 7396- 1:2016+A1:2017 28mm line isolation valve | Numbers | 10.00 | 5,015 | 50,150 |
| 24 | NS-24). Supply, installation, testing & commissioning of ine Isolation valves Confirmed to BS EN 331: 2015, IS/ISO 7396- 1:2016+A1:2017 35mm line isolation valve | Numbers | 4.00 | 9,735 | 38,940 |
| 25 | NS-25). Supply, installation, testing & commissioning of Electrical Control Panel for Vacuum Pump | Numbers | 1.00 | 1,00,300 | 1,00,300 |
| 26 | NS-26). Supply, installation, testing & commissioning of Vacuum hoses- Antistatic Single braided PVC hoses ( Yellow color ) | Metre | 50.00 | 118 | 5,900 |
| 27 | NS-27). BED HEAD PANEL FOR ICU ( Doubel duct) | Metre | 15.00 | 21,830 | 3,27,450 |
| Schedule total | ₹32,28,002.1 | ||||
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
HTML
nit.pdf
NIT
AnnexureVforsmallvaluetenders.pdf
ATTACHMENT
AnnexureVAforsmallvaluetenders.pdf
ATTACHMENT
SpecialconditionmedicalgaspipelineF.pdf Special Condition of Contract
ATTACHMENT
BRANDLISTFORMEDICALEQUIPMENTS.pdf Approved Brand List
ATTACHMENT
PublicProcurementOrder.pdf
ATTACHMENT
TDGCCMarch_262.pdf
ATTACHMENT
SpecialconditionmedicalgaspipelineF.pdf
ATTACHMENT
BRANDLISTFORMEDICALEQUIPMENTS.pdf
ATTACHMENT
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .