| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹28.6 LAccepted-AOC 219 10 NEW SARVODAY COLONY YADGARPUR MEERUT CITY INDEX NO D 308 HQ CE CC | L1 | Accepted-AOC Found lowest bidder | |
| 2 | L2₹28.8 L+₹3,300 (0.11%)Rejected-Finance 150 BC LINE MALL ROAD MEERUT CANTT 250001 | MEERUT | UTTAR PRADESH | 250001 | L2 | Rejected-Finance 2nd lowest | |
| 3 | L3₹33.8 L+₹5.0 L (17.3%)Rejected-Finance D 249 GREEN ESTATE A2Z BUILDER DEVELOPERS NH 58 ROORKEE ROAD MODIPURAM MEERUT UP 250110 | MEERUT | MEERUT | UP | 250110 | L3 | Rejected-Finance 3rd lowest |
Tender Value
₹45 L
EMD Value
₹90,000
Closing Date
29 Apr 2024, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE (North) Meerut Cantt
GE (North) Meerut Cantt
REPAIR/CLEANING OF SEWAGE LINE, SEPTIC TANK, SOAK WELL, MAN HOLES AND OTHER CONNECTED WORKS UNDER AGE B/R-II OF GE (NORTH) MEERUT CANTT
2024_MES_648674_1
8492/E8
Open Tender
Civil Works
Item Rate
240 days
Meerut
Class D Category a (i)
8 documents required · 8 mandatory
₹500
GE (North) Meerut Cantt
₹90,000
Yes
8 Jun 2024
30 Mar 2024
1 May 2024
30 Mar 2024
29 Apr 2024
15 Apr 2024
Amount
Cleaning of underground Horizontal sewage pipe of any dia upto 200mm (Cleaning length not exceeding 30m from manhole to manhole or from manhole to septic tank) including taking off manhole cover and cleaning of manholes of any size and depth and removing waste material/sludge to a distance of n.exc 300m and burying in a pit and replacing manhole cover in position after cleaning complete all as specified and directed.
Cleaning and maintenance of sewage line of size 150mm dia and 2 to 6 meter depth manholes (as per MAP QTR COMMON CENTRAL SEWAGE LINE and MANHOLES) in the following steps:- (i) Dewatering of manholes (ii) Removing of all sludge/waste material from all manholes, desalting of floor, lean the floor and walls of the manhole after removing complete sludge/materials with clean water (iii). Removing the temporary blockage of inlet/outlet pipe and making functional the manholes. (iv) Remove all taken out sludge/ waste materials in covered containers out side the Defence Land. any means and getting out and removing sludge to a distance up to 3 km out side of defence land limit and disposal in low lying area and including removing of all types of blockage of any length between two consecutive deep manholes and to keep smooth functioning without any blockage in any situation by mechanical means with manual and mechanical process including removal and refixing of man hole covers complete all as specified and as directed.
Dewatering of Septic tank soakage well and manhole of any depth in any position by pumping out and removing outside Military/Defence land by mechanical means (trolley mounted) and burying in pits all as directed including digging of pits in any type of soil and covering pits with earth after absorption of water and including providing and spreading required quantity of bleaching powder around the pit or dispose of waste material as per state protocol and washing the top of septic tank & soakage wells and surrounds with fresh water and sprinkling lime to make hygienic complete all as specified and as directed. Note : 4000 Ltr container considered for one trip.
De-sludging of Septic tank of any capacity including connected intercepting chamber, manhole shaft, sludge chamber & filter beds of any description and in anomy position by pumping out and removing of sludge outside Military/ Defence land by mechanical means (trolley mounted) and burying in pits all as directed including digging of pits in any type of soil and covering pits with earth after filling of sludge and including providing and spreading required qty of bleaching powder or dispose of waste material complete as per state protocol, including taking down of slab cover and placing the same in existing position complete all as specified and as directed.
Attending and rectifying sewage complaint such as blockage of chocked bathroom / WC / kitchen block / WHB drainage / chamber and also tightening of loose rain water pipe and outlet PVC pipe and making functional open drainage main hole sewage line etc complete all as specified and directed and directed any type any time between 9 AM to 6 PM including holiday all as specified and as directed. Note : (1 )Only experienced 04 Nos sewage cleaners shall be used to attend day to day complaints for above mentioned complaint shall be issued under respective item. (2.) Contractor or his representative shall collect the complaints at 0830hrs from complaint cell of AGE B/R-II and the complaints shall be attended / make good/rectified within 24hrs on receipt of the complaints and info the status of the complaint at 1700hrs every day to complaint cell. On failure of the same a penalty of Rs 250/- per day per complaints shall be charged.
Cutting of grass, growth/vegetations, bushes or like and similar work and making the workable space for carrying out cleaning of sewage line/manholes in any location or condition etc all as specified and directed.
Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing) removing serviceable to store and rubbish off the premises complete all as specified and directed.
M&L 25 mm thick PCC 1:2:4 Type B-1 (20mm graded aggregate) as in sub-floor, sub-base, floor and pavings, etc. complete all as specified and directed.
S&F Non skid coloured ceramic tiles 7 to 8 mm thick (square/rectangular) area of each tile exceeding 0.11Sqm but not exceeding 0.18Sqm (400x400mm), as in floors etc. set and jointed in neat cement slurry and pointed in coloured cement to match the coloured tiles 15mm thick screed bed or bedding layer in CM 1:6 for laying floor finishes complete all as specified and directed.
M&L coloured glazed ceramic tiles in vertical surface 450X350X7mm thick set and jointed in neat cement slurry and pointed in white or colored cement laid over and including 10mm thick rendering in cement mortar 1:4 complete all as specified and directed.
S&F in repairs vitrious china squatting pan Orissa pattern size 580x440mm white with integal foot rest, including concrete bedding, P or S trap lime concrete bedding and all internal fitting, inlet, outlet pipe connections etc & making good floor complete all as specified and directed.. Make CERA/Hindware
S&F in repair vitreous china wash down water closet pan (pedestal pattern), white with 'P' or 'S' trap (excluding flushing cistern and flush pipe) including seat and cover and connection to drain or out going pipe and to flushing pipe, antisyphonage pipe etc complete all as specified and directed Make CERA/Hindware
S&F in repair PVC valveless flushing cistern 10 Ltr capacity (white), syphonic action type, flushing cistern, low level, white, with inlet, ball valve, float and handle including brackets and flushing pipe complete all as specified and directed.
S&F in repairs PVC connection 15mm size with PTMT nuts of length 450mm long complete all as specified and as directed by Engineer-in-Charge.
S&F in repair 15mm dia stop valves of cast copper alloy screwed down high pressure with crutch or butter fly handle screwed both ends for iron pipe or for union complete all as specified and directed.
M&L for construction of Soakage wells of size 2.40m dia & 6.00m depth ( effective depth 4.5 m ) in ordinary Soil, Foundation in PCC 1:3:6, wells of Honey combed and solid in M-25 RCC including intercepting chamber, screen chamber Brick work in cement mortar 1:4, RCC cover slab in M-25/ RR masonry / Filling with brick bats, all as including necessary earth work in any type of soil (soft / loose / hard / dense) all as shown on drg No TD-309 Sheet Nos 1/4 to 4/4. complete all as specified and directed. Note - (i) All types of equipments and safety kit required for working in foul condition shall be provided by the contractor to his workmen. The Engineer-in-Charge shall verify these aspects during currency of work. Al precautions/safety measures shall be kept in mind during execution of work. (ii) Old soak well and septic tank shall be left abandoned.
M&L for construction of septic tanks, foundation in PCC 1:2:4, brick work in cement mortar 1:4, RCC Slab covers including RCC precast manhole cover having 6mm plate embedded all around/fiber reinforced cover with angle iron frame Vent shaft and sludge chambers etc. for 25 users including necessary earth work in any type of soil (soft/loose/hard/dense) all as shown on drg No TD-217 sheet No 17/ to 7/7 complete all as specified and directed.
M&L for construction of septic tanks, foundation in PCC 1:2:4, brick work in cement mortar 1:4, RCC Slab covers including RCC precast manhole cover having 6mm plate embedded all around/fiber reinforced cover with angle iron frame Vent shaft and sludge chambers etc., for 50 users including necessary earth work in any type of soil (soft / loose / hard / dense) all as shown on drg No TD-217 sheet No 1/7 to 7/7 complete all as specified and directed. Note - (i) All types of equipments and safety kit required for working in foul condition shall be provided by the contractor to his workmen. The Engineer-in-Charge shall verify these aspects during currency of work. Al precautions/safety measures shall be kept in mind during execution of work. (ii) Old soak well and septic tank shall be left abandoned.
Excavation in trenches not exc 1.5 m wide and not exc 1.5 m in depth for cesspits, manholes etc, and getting out soft/loose soil even in foul position complete all as specified and directed.
-Ditto- as per item No 19 above but exc 1.5m and n.exc 3.0m deep complete all as specified and directed.
Returning, filling in and including spreading, leveling, watering & well ramming in layers n.exceeding 25 cm in soft/loose soil complete all as specified and directed.
Removing of excavated materials to a distance n. exc 50m and depositing where directed at a level n exc 1.5m above the starting point in oft/loose soil complete all as specified and directed.
Demolition and breaking up drain pipes of internal dia 150mm (SGSW/PVC/RCC etc) set in cement mortar including bed concrete and removal of debris to low lying area of distance not exceeeding 100m complete all as specified and directed. by Engr-in-Charge.
All as per serial Item No 23 mentioned here-in-before but internal dia of pipe 200mm complete all as specified and directed. by Engineer -in-Charge
M&L for 200mm bore of reinforced concrete pipe class NP2 laid in trenches and jointed with collar complete all as specified and directed.
M&L for Concrete bed to drain pipes of size 200 mm bore packing under and haunching against the sides of pipes after they are laid and fitted in cement concrete,Type C-2 1:3:6 using 40 mm graded stone aggregate complete all as specified and as directed.
M&L Ultra P E,DWC (Double wall corrugated) pipe confirming IS-16098 Part-2 2013 pertaining structure wall plastics pinning system for sewage 150 mm bore and above bore pipe SN-8 and all necessary fittings and fixtures complete all as specified and as directed.
M&L 150mm bore Salt-glazed stone ware drain pipes laid in trenches and jointed complete all as specified and directed.
M&L 200mm bore Salt-glazed stone ware drain pipes laid in trenches and jointed complete all as specified and directed.
M&L for Concrete bed to drain pipes of size 150 mm bore packing under and haunching against the sides of pipes after they are laid and fitted in cement concrete,Type C-2 1:3:6 using 40 mm graded stone aggregate complete all as specified and as directed.
Demolition of brick work built in cement mortar for cracked wall of drain,manholes, sepic tank, soak pit etc in foul position complete all as specified and directed.
Demolition of old decayed / damaged brick work in cement or cement lime mortar and in any condition including removal of same complete all as specified and directed.
M&L for PCC 1:4:8 type D-2 (using 40mm graded stone aggregate) in foundation filling and mass concrete for bottom of manhole complete all as specified and directed.
M&L brick work with fly ash old size bricks, straight or curved on plan exceeding 6 cm mean radius built in cement mortar 1:4 complete all as specified and as directed.
M&L for (Except brick) brick work with Sub class ‘B’ bricks straight or curved on plan exceeding 6m mean radius built in CM 1:4 complete all as specified and directed by Engr-in-Charge.
M&L for Plain cement concrete (1:3:6) type C-2 (using 40mm graded stone aggregate) as in surface channel and drain complete all as specified and directed.
Taking down cement plaster from inside/outside of existing septic tank/manholes etc incl raking out joints, hecking for key scrubbing down with water and removal of rubbish off the premises complete all as specified and directed.
M&L for Rendering 15mm thick in CM 1:4 on brick / concrete surfaces finished even and smooth without using extra cement including mixing water proofing compound as per Manufacturer's instructions complete all as specified. Note: Water proofing compound shall be measured and paid separately.
Supply only Liquid water proofing compound (ISI Marked) of approved make complete all as specified and directed.
M&L for providing PCC 1:3:6 type C-1 (using 20 mm graded stone aggregate) as in coping of manholes and similar work inclussive of form work complete all as specified and directed.
M&L for Precast RCC 1:2:4, Type B–1 using 20mm graded stone aggregate as in landings, cover slabs [for manholes etc], chullah hoods, Chajjas, water troughs, mangers, Shelves and similar articles with plain faces including formwork, set in cement mortar 1:4 complete all as specified and as directed
M&L for mild steel TMT bar 10mm dia and over, cut to length bent to shape required including cranking bending spirally for hooping for column, hooking end binding with binding wire and including mild steel wire(annealed) not less than 0.9mm dia complete all as specified & directed by Engineer in Charge.
M&L for filling of brick bats of size (as directed by Engr-in-Charge) in soak well laid dry complete all as specified and directed.
Demolition of cement concrete (Unreinforced) in ground floor and paving n exc 15 cm thick below or above ground level complete all as specified and directed.
M&L for 100 mm thick PCC 1:2:4 Type B-2 (40mm graded aggregate) as in sub-floor, sub-base, floor and pavings, etc. complete all as specified and directed.
M&L for 75mm thick PCC 1:3:6 Type C-2 (40mm graded aggregate) as in sub-floor, sub-base, floor and pavings, etc. complete all as specified and directed.
M&L for Sand filling under floors or in foundation including watering and consolidation, complete all as specified and directed.
M&L for Machine pressed precast concrete interlocking paver block laid in floor, any shape and size conforming to IS-15658-2006 of 60mm thickness M-35 grade with grey cement & pigment, (glossy finish) complete all as specified and directed.
M&L for Cement concrete 1:3:6 type C-1 (using 20mm graded stone aggregate) in roof kerbs or mud stops, rounded or chamfered on edges complete all as specified and directed.
M&L for cutting and removing of bushes, small trees, vegetation (Peepal, bad small plants etc) of any ida and girth from roof projection, chajjas, wall junction, parapet etc at any height by necessary demolition of brick work, cement plaster, digging out roots from concrete or brick wall filling holes on building wall/roof/chhajja/water tank staging area etc and making good with cement mortar 1:4 complete all as specified and directed.
Taking down eaves gutters and rainwater pipes (any size or pattern), including all fittings, heads, shoes, bends, swan-necks, etc., including cleaning or refixing or removal to Store (measured overall as fixed along the centre line over fittings and accessories) complete all as specified and directed.
M&L in repair 110mm bore, PVC (SWR) pipes, single socketed, in any length, with rubber ring joints fixed on walls excluding clamps fixed to wall properly including fixing of pipe with PCC (1:2:4) complete all as specified & directed.
M&L in repair 75mm bore, PVC (SWR) pipes, single socketed, in any length, with rubber ring joints,laid in trenches or in floors or wall complete all as specified & directed.
S&F in repair 110mm bore PVC (SWR) bends any radius complete all as specified and as directed by Eng-in-Charge
All as per item No.35 mentioned here-in-above but with access door complete all as specified and directed.
S&F in repair 110 mm bore PVC (SWR), junction single, (single T), equal or unequal with access door complete all as specified and directed.
S&F in repair 110 mm bore PVC (SWR), junction double, (double T), equal or unequal with access door complete all as specified and directed.
S&F in repair PVC (SWR) reducers of 110 mm bore complete all as specified and directed.
S&F in repair 110 mm PVC (SWR) branch piece, single Y equal or unequal complete all as specified and directed
S&F in repair 75mm bore PVC (SWR) bends with rubber ring joints fixed to wall and jointed complete all as specified and directed.
All as per item No. 47 mentioned here-in-above but with acees door complete all as specified and directed.
S&F in repair 75 mm bore PVC (SWR), junction single, (single T), equal or unequal with access door complete all as specified and directed.
S&F in repair 75 mm bore PVC (SWR), junction double, (double T), equal or unequal with access door complete all as specified and directed.
S&F in repair 110mm bore PVC(SWR) vent Cowl complete all as specified and directd.
S&F in repair 75mm bore PVC(SWR) vent Cowl complete all as specified and directd.
S&F in repair 75mm bore PVC (SWR) floor trap, plain with grating including jointing with solvent cement complete all as specified and directed.
S&F in repair CP grating (with and without hole) of size 125mm complete all as specified and directed.
Cutting of roads for removing damaged drain pipes and laying of pipes with all neccessary fittings any length with collers, laid in trenches or in floors 150/200mm bore complete all as specified and as directed including making good the road cutting complete all as specified and directed. Note. pipe will be measured separately in respective item.
Cutting into exisiting manholes 150mm dia for connecting new drains, making good to pipe and rendering, cutting out existing benching for and forming branch channel (1/2 round or 3/4 section) in cement concrete 1:2:4 type B-1 smooth finished and reforming benching as required complete all as specified and directed.
VIRAT CONSTRUCTIONS
Tridev Construction Company
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.PDF
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .