Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹3.6 LAccepted-AOC NEAR SOLAPOKHARI PO INS CHILKA DIST KHURDA ODISHA 752 037 | KHORDHA | ODISHA | 752037 | L1 | Accepted-AOC Accepted being L1 bidder | |
| 2 | L2₹4.0 L+₹27,965 (7.48%)Rejected-Finance JANUGANJ REMUNA GOLAI BALASORE 756 019 ODISHA | BALESHWAR | ODISHA | 756019 | L2 | Rejected-Finance Being L2 | |
| 3 | Rejected-Technical | - | Rejected-Technical Due to not in appropriate category |
Tender Value
₹4 L
EMD Value
₹8,000
Closing Date
20 Aug 2021, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Shri Avinash Mishra IDSE GE
Garrison Engineer (I) (CG) Bhubaneswar Near NTPC Guest House Post Pokhariput Bhubaneswar 751020
REPAIR AND MAINT OF COOLING APPLIANCES
2021_MES_461803_1
8249/BBSR/04/E8
Open Tender
Miscellaneous Works
Item Rate
180 days
Paradip
Please refer Tender documents.
8 documents required · 8 mandatory
₹300
Yes
GE (I) (CG) Bhubaneswar
₹8,000
Yes
21 Oct 2021
22 Jul 2021
23 Aug 2021
22 Jul 2021
20 Aug 2021
5 Aug 2021
23 Jul 2021 - 2 Aug 2021
60 days
Amount
Repairs and maintenance and Servicing of Split type AC's, Refrigerators, Water coolers installed at any location including attending complaints received from User, to rectification of Electric circuits in AC's, water coolers, refrigerators, periodical maintenance to outdoor and indoor unit of Split AC or other cooling appliance by attending any numbers of breakdown calls during contract period complete all as specified and directed :- (a) Split Air Conditioner 2.0 ton
Split Air Conditioner 1.5 ton (including inverter model)
Split Air Conditioner 1 ton
Water cooler capacity 40/80 Ltrs.
Cassette Air Conditioner 1.5 ton
Refrigerator capacity 320 Ltrs Note :- for item No-1.00 to 1.05 (i) Air filter should be properly cleaned in every month of indoor unit deemed to be included in unit rate. (ii) out door units should be properly cleaned with the use of pressurized air/water in every three months deemed to be included in unit rate. (iii) Spare parts if any replaced, shall be measured and paid separately as under schedule 'A' Part-II by supply only. Old unserviceable spare parts removed from the Installations and shall be accounted as under schedule of credit. Material & Labour for item Nos 20, 26, 27, 28, 33, 34, 36, 37, 39 & 40 shall not included in this unit rate . (iv) The price included for tracing out leakage in AC installed upto G+3 level in discharge line and providing suitable thermal insulation upto 10 m and cleaning de-humidification drain out pipe to prevent seepage of water on the wall. If any minor leakage will be rectify with brazing /welding (v)The required stationary, tools and registers (i.e Complaint register, complaint slip book etc) , cleaning materials such as cotton waste, grease etc and any minor comsumable parts, all transpotations cost to ensure smooth operation should be included in rate quoted for this item. (v) cost of minor points ie bolts,nuts,washers are deemed to be included in unit rate.
Supply only of starting capacitors as per suitable Mfd for 1.5 ton/2 ton Air Conditioner's complete all as specified and directed.
Supply only of starting capacitors as per suitable Mfd for 1 ton Air Conditioner /water cooler/Referegerator complete all as specified and directed.
Supply only of running capacitor as per suitable Mfd for 1.5 ton/2 ton Air Conditioner's complete all as specified and directed.
Supply only of running capacitor (36-45) Mfd for 1 ton Air Conditioner /water cooler/Referegerator complete all as specified and directed.
Supply only in replacement of printed circuit board (PCB) for non inverter model 1.5/1 Ton AC's for indoor/outdoor unit complete all as specified and directed. Make : LG.
Supply only in replacement of printed circuit board (PCB) for Splint AC inverter model/casette inverter model 1.5 Ton AC's for indoor/outdoor unit as per site requirement complete all as specified and directed. Make : LG/Hitachi.
Supply only in replacement of printed circuit board (PCB) for non inverter model 2Ton AC's for indoor/outdoor unit complete all as specified and directed. Make : LG.
Supply only of hermetically sealed rotary type compressor of capacity 1.5 Ton suitable for air conditioner of any make/type including replacement of foundation bolts, rubber pad etc, complete all as specified and directed.Make : Hitachi / Voltas / LG /Copeland / Blue Star.
All as per item No.9 here-in-before but 2.0 TR capacity.
All as per item No.9 here-in-before but 1.0 TR capacity.
Supply only of fan motor outdoor unit with suitable blade for 1/1.5 ton capacity Split type Air Conditioner's complete all as specified and directed.Make: CG/Kirlosker/ Carrier.
All as per item No.12 here-in-before but 2.0 TR capacity.
Supply only of fan motor indoor unit with all accessories for 1.5 ton capacity Split type AC's complete all as specified and directed.
Supply only of remote for Split type 1.5 TR Air Conditioner's of any make and model of capacity complete all as specified and directed.
Supply only copper capillary tube 3/8+5/8" as suitable size for split Air Conditioner of any capacity with proper insulation all as specified and directed. (Note:2 run of Copper copper capillary tube including insulation shall be measured as one length.)
Supply only copper capillary tube(1/4"+ 3/4" ) or (1/4"+5/8") or (1/4"+1/2") or (1/4"+1/2") as suitable size for split Air Conditioner of any capcity with proper insulation all as specified and directed. . (Note:2 run of Copper copper capillary tube including insulation shall be measured as one length.)
Supply only gun metal discharge valve of any size of capillary tube as suitable size for split AC of any capacity complete all as specified and directed.
Supply only Push cock spring loader 15mm dia cast copper alloy chorumium plated alongwith gasket complete all as specified and directed.
Removing the existing insulation from suction line of Split Air Conditioner's of various size inserting of new insulation PPN black foam complete with spacers and saddle etc. on walls without damage to existing pipe complete all as specified and directed.
Supply in replacement of outdoor unit of Split type Air Conditioner of capacity 1.5 TR including copper condensing coil, , coil frame, wiring kit, starting and running capacitor, relay condensing motor with blade, expansion valve etc complete all as specified and directed.
Supply in replacement of outdoor unit of Split type Air Conditioner of capacity 2.0 TR including copper condensing coil, energy efficient compressor, coil frame, wiring kit, starting and running capacitor, relay condensing motor with blade, expansion valve etc complete all as specified and directed.
Supply in replacement of indoor unit of Split type Air Conditioner of capacity 1/1.5 TR with anti corrosive fins, complete all as specified and directed.
All as per item No-23 here-in-before but 2.0 TR capacity complete all as specified and directed.
Supply only in replacement of Air filter made out of Nilon or suitable make for any type and make of Split type Air Conditioner 1.5/2.0 TR capacity any model complete all as specified and directed.
Dismantling and opening of stabilzer unit and taking out of old Unservesable PCB unit replaced with new PCB same as exist and refixing on existing places of capacity 5 KVA/4KVA stabilizer complete all as specified and directed.
Dismantling and opening of stabilizer unit and taking out of Auto cut relay replaced with auto cut relay same as exist and refixing on existing places of capacity 5 KVA/4KVA stabilizer complete all as specified and directed.
Dismantling and opening of stabilizer unit removing variable transformer and taking out of old burnt transformer replaced with new transformer of same rating refixing on existing places of capacity 5 KVA/4KVA stabilizer complete all as specified and directed.
Supply only of Copper Cooling Coil (Evaporator )unit of Split type Air Conditioner of capacity 1.5 TR complete with complete all as specified and directed.
All as per item No-29 here-in-before but 2.0 TR capacity complete all as specified and directed.
Supply only of starting relay unit suitable for refrigerator 310 litres capacity complete all as specified and directed.
Supply only wall mounting stand complete set suitable for split Air Conditioner outdoor unit of cap 1.5/ 2TR complete all as specified and directed.
Preparation of old painted surface of the water cooler 40 / 80 litres cooling capacity and painting the same with two coats of synthetic enamel paint over a coat of red oxide primer including removing corroded portion of steel surfaces including any leakage on water storage tank welded in leakage if any and provision of new mild steel sheet 18 guage fixed in position duly welded and suit the adjoining surfaces complete all as specified and as directed.
Disconnecting all electrical connection and remove the Split Air Conditioner including copper pipes of Split AC from uniform position and shifted the same to near location and reconnection the A/c after making suitable hole with drill machine and connection to electrical lines including closing the hole with brick masonry and matching with existing colour of wall complete all as specified and directed.
Supply only Eco friendly refrigerant gas HFC (R-410 A) / R-22 charging any type in air conditioners, refrigerator and water cooler any make and type, testing and commissioning the equipment complete all as specified and directed.
M&L pressure testing the compressor including connecting pipe line with nitroen gas and rectify the leakages by means of welding, soldering, brazing etc for split Air Conditioner / watercooler/refrigerant of any capacity complete all as specified and directed.
S&F in repairs PVC (HDPE) Pipe of pressure rating 6 kgf/cm2 of size 20 mm dia heavy grade with L bend, Elbow, Tee, etc suitable to connect split type AC drain line. Pipe lines shall be fixed on wall or floor upto G+3 level of the building with necessary clamping arrangement complete all as specified and directed.
Supply only 2.5 sqmm PVC insulated unsheathed three core cable 1100 volts grade, multistranded with copper conductor complete all as specified and directed.
Supply and fixing in replacement of sheet metal enclosure, SP type with two pin & earth plug and socket (Industrial type DB) with and including one MCB SP, C Curve type of capacity 20/32 Amp, 10 kA complete all as specified and directed.
Supply and fixing in replacement of MCB C type, 10 kA, 10 to 32 Amp, Single Pole with over load and short circuit protection complete all as specified and directed.
M/s LADHANIA BROTHERS
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .