Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L_1₹15.0 LAccepted-AOC NEAR MES FILTER PLANT SANGOOR UDHAMPUR J K 182101 | UDHAMPUR | UDHAMPUR | J K | 182101 | ₹15.0 L | L_1 | Accepted-AOC Being L-1 |
| 2 | L-2₹18.2 L+₹3.1 L (20.8%)Rejected-Finance 53 HOUSING BOARD COLONY PHASE II UDHAMPUR 182101 J K | UDHAMPUR | UDHAMPUR | J K | 182101 | ₹18.2 L+₹3.1 L (20.8%) | L-2 | Rejected-Finance other than L-1 |
| 3 | L-3₹18.5 L+₹3.5 L (22.9%)Rejected-Finance | ₹18.5 L+₹3.5 L (22.9%) | L-3 | Rejected-Finance other than L-1 |
| 4 | L-4₹22.8 L+₹7.8 L (51.7%)Rejected-Finance 6 RAILWAY STATION ROAD ONKAR INDUSTRIES GULAMALI PURA BAHRAICH UTTAR PRADESH 271801 | BAHRAICH | UTTAR PRADESH | 271801 | ₹22.8 L+₹7.8 L (51.7%) | L-4 | Rejected-Finance other than L-1 |
| 5 | L-5₹24.5 L+₹9.5 L (63.1%)Rejected-Finance NEAR INDUSTRIAL ESTATE THANDA PADDAR UDHAMPUR J K 182101 | UDHAMPUR | JAMMU AND KASHMIR | 182101 | ₹24.5 L+₹9.5 L (63.1%) | L-5 | Rejected-Finance other than L-1 |
Tender Value
₹29.9 L
EMD Value
₹59,850
Closing Date
22 Jul 2020, 6:00 pmClosed
Sh A K Dubey, IDSE , SE CWE
Military Engineer Services, Commander Works Engineer, Udhampur, PO - Garhi, Udhampur-182121
Repair / maint of HT UG cable, switch gear and allied works in MPH and CPH area under GE (Utility) Udhampur
2020_MES_350498_1
CWE/U(U)-43/2020-21
Open Tender
Electrical and Maintenance Works
Item Rate
240 days
Udhampur
AS PER TENDER
7 documents required · 7 mandatory
₹500
GE (Utility) Udhampur
₹59,850
Yes
25 Aug 2020
6 Jun 2020
24 Jul 2020
6 Jun 2020
22 Jul 2020
10 Jul 2020
Amount
Maintenance & servicing of 33 KV VCB including control & relay panel and OLTC panel incl setting of operating mechanism parts, checking of wiring,tightening of loose connections, spring charging mechanism, well cleaning with petrol and CRC-226 ,oiling/ greasing of moving parts and well cleaning of pole insulator, checking of vaccum, interupters well cleaning of mechanism links feeble reinforced plastic frame around the vaccum interupts including routine and periodical test including testing, calibration and checking of tripping system of 33 KV control panel through all protective relays installed on each C&R panel including testing and adjust/ repair the alarm circuit as per time current characteristics by primary injection test at 60%, 75%, 100% plug including well cleaning and decarbonizing of relay contracts complete all as specified and directed by Engr-in-Charge.
Servicing, repairing and overhauling of 33 KV isolator including cleaning of complete moving and fixed contacts including oiling/ greasing pf operating mechanism tightening connections and replacement of unserviceable parts including reassembling the isolator after complete repair all as specified and directed.
Replacement of post insulator of 33 KV air break switch isolator rotating type complete all as specified and directed.
Replacement of terminal pad of 33 KV air break switch isolator rotating type complete all as specified and directed.
Replacement of arching horn of 33 KV air break switch isolator rotating type complete all as specified and directed.
Replacement of connector of 33 KV air break switch isolator rotating type complete all as specified and directed.
Replacement of operating down pipe of 33 KV air break switch isolator rotating type complete all as specified and directed.
Replacement of operating box of 33 KV air break switch isolator rotating type complete all as specified and directed.
Replacement of pad locking of 33 KV air break switch isolator rotating type complete all as specified and directed.
Replacement of fixed contact assembly of 33 KV air break switch isolator rotating type complete all as specified and directed.
Replacement of moving contact assembly of 33 KV air break switch isolator rotating type complete all as specified and directed.
Supply, installation & testing HT out door type gang operated rotating type, triple pole, mechanically operated air break switch 33 KV rating, 400 Amps capacity, horizontal mounting, double break, mounted on insulation and steel frame, Gl operating rod of suitable length to be worked from ground level complete complete all as specified and directed by Engr-in-Charge.
Maintenance of 33 KV yard comprising of painting the yard with one coat of synthetic enamel paint as required and writing the designation of equipments in English albhabets/ letters as specified & as directed by Engr-in-charge and mainly the following:- (i) Structure of LA set (ii) Structure of isolator (iii) Misc structure (iv) Iron gate-01 No
Spray painting of transformer 33/11 KV of capacity 6.3 MVA at site with one coat of weather proof grey synthetic enamel paint after removing all dust, rust, carbon and oily spots, including well preparation of surfaces and writing /marking SM/MES No as 25mm stencil using white paint complete all as specified including cleaning of temperature gauge and silica gel , oil temperature level complete all as specified and directed by Engr-in-Charge.
Complete draining out the transformer oil from radiators after closing the inlet valve from main body of 6.3 MVA power transformer including filling transformer oil of good quality having not less than 70 KV dielectric strength, having low viscosity and testing of Transformer after filling new oil complete upto 10 Hrs minimum all as specified and directed by Engr-in-Charge. Make: Savita/Power oil as per IS 335 of 1983
Replacement silica gel breathers assembly filled complete suitable for transformer cap 6.3 MVA (As per Sample) complete all as specified and directed by Engineer-in-Charge.
Replacement of current transformer CT Ratio 150/75/5-5A of 11 KV, 15VA, Core 1, class-0.5, STC 18.4 KA for 1 sec complete all as specified and directed by Engr-in-charge. Make:-AREVA/ ABB / L&T
Replacement of current transformer CT Ratio 400/200/5-5A of 33 KV, 15VA, Core 1, class-0.5, STC 20 KA for 1 sec complete all as specified and directed by Engr-in-charge. Make:-AREVA/ ABB / L&T
Replacement of current transformer CT Ratio 200/100/5-5A of 11 KV, 15VA, Core 1, class-0.5, STC 18.4 KA for 1 sec complete all as specified and directed by Engr-in-charge. Make:-AREVA/ ABB / L&T
Dismantling of unserviceable steel tubular swaged pole/ PCC pole complete with accessories all as directed by Engieer-in-Charge.
Taking down carefully old unserviceable insulator (any type/size) from existing over head lines complete all as specified and directed.
Dismantling of unserviceable ACSR Conductor of any size from existing over head lines completed all as specified and directed.
Dismantling/ taking down of unserviceable/ damaged Air break switch of any cap.& removing from site of works all as specified and directed.
Dismantling of cross arms of MS fabricated complete with all accessories viz nut, bolts, washer etc. complete all as specified and directed.
Dismantling/ taking down of unserviceable/ damaged Lightning arrestor, high tension,any type & removing from site of works all as specified and directed.
Pin insulator porcelain viterous brown including 01 galvanized M.S.spindle, two galvanised iron washers and one gal. iron nut suitable for HT 33000 Volts complete all as specified and directed by Engineer-in-Charge.
Disc Insulator with 3 in a row 11 KV hardware, clamps,etc complete suitable for 33 KV HT porcelain viterous brown complete all as specified and directed by Engineer-in-Charge.
ACSR conductor of required size for Over head lines on poles including streching, tightining of poles insulator with winding wire of suitable size with insulator/streching of ACSR conductor all as specified and directed by Engineer-in-Charge.
Painting to steel tubular swaged pole of Overhead lines (11 Mtr long) complete with and including comprising the following works :- (a) Scraping out wornout old paint and making the surface smooth. (b) Painting the pole and all MS work mounted on pole with two coats of synthetic enameled paint (Aluminium shade) as directed by Engg.-in-charge. (c ) Forming five nos coloured bands at lower portion of pole each 300 mm wide alternatively with white and black colour (or any colour as approved by Engg.-in-charge)synthetic enameled paint and marking pole no. with black and white paint complete all as specified.
Steel tubular swaged pole erected to truly vertical or planted as strut complete with 6 mm thick MS Base plate,welded to pole,finial taper cap, bolts, nuts, screws,11 Mtr long, type 410 SP - 55,including drilling of holes of required size for fixing of cross arms,painting the exposed surfaces of pole with two coats of aluminium paint over a coat of red oxide zinc chrome primer and with two coats of black bituminous paint on the portion embedded in concrete, and marking pole no. with black paint at suitable height all as specified and directed by Engr-in-Charge. Note:- The earthwork, PCC foundation, steel clamps, MS Cross arms & bracing of angle iron etc will be measured and paid separately under relevant items of Sch ‘A’
XLPE insulated screened PVC bedded galvanised steel strip or wire armoured electric power cable (Heavy Duty) with aluminium conductor 33000 volts grade cross sectional area 185 sq mm, 3 core including taking down of U/S Cable complete all as specified and directed by Engineer-in-Charge
XLPE insulated screened PVC bedded galvanised steel strip or wire armoured electric power cable (Heavy Duty) with aluminium conductor 11000 volts grade cross sectional area 150 sq mm, 3 core including taking down of U/S Cable complete all as specified and directed by Engineer-in-Charge
XLPE insulated screened PVC bedded galvanised steel strip or wire armoured electric power cable (Heavy Duty) with aluminium conductor 11000 volts grade cross sectional area 120 sq mm, 3 core including taking down of U/S Cable complete all as specified and directed by Engineer-in-Charge
Excavation in trenches in any type of soil not exceeding 1.50 m wide and not exceeding 1.50 mtr in depth and getting out for pipe, cable pole, stay etc, all as specified and directed by engineer-in-Charge.
Description all as per Srl item No. 34 here in before but depth exceeding 1.5m but not exceeding 3m complete all as specified & directed by Engineer-in-charge.
Returning filling in ( soil ) including spreading leveling watering and well ramming in layers not exceeding 25cm thick, all as specified.
Removal of excavated material (soil) to a distance not exceeding 50 m and depositing where directed at a level not exceeding 1.5m above the starting point all as specified.
Dry sand cushioning to underground cable provided with layer of 8 cms deep before laying the cable and 15 cms deep after laying and stretching the cable complete all as specified. Note : Punned thickness shall be measured.
Precast unreinforced concrete cable cover (ISI Marked) class HV, TYPE 2, flat, size 300mmx180mmx40mm conforming to IS-5820 (1970), for protection of under ground cable, complete all as specified and as directed by Engr-in-Charge.
Cable jointing kit for 11 KV (Earthed) grade cable for outdoor termination heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 95 sqmm complete, all as specified and directed by Engineer-in-Charge.
Description al as per Srl items No 40 here-in-before but for 120 to 185 sqmm complete, all as specified and directed by Engineer-in-Charge.
Cable jointing kit for 33 KV (Earthed) grade cable for outdoor termination heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 185 sqmm complete, all as specified and directed by Engineer-in-Charge.
Cable jointing kit for 33 KV (Earthed) grade cable for indoor termination heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 185 sqmm complete, all as specified and directed by Engineer-in-Charge.
Tubing 'light grade' galvanised iron of 150 mm bore with all fittings and fixed to poles, walls etc. with flat iron clamps/bolts/nuts/washers or laid in floors/under roads complete all as specified and directed.
HT insulation empire tape yellow colour of width 25mm 10 mtr long ISI marked complete all as specified and directed.
Plain cement concrete 1:3:6 type C-2 (using 40mm graded stone aggregate) as in foundations filling and mass concrete complete, all as specified and directed by Engr-in-Charge.
Plain cement concrete 1:2:4 type B-1(using 20 mm graded stone aggregate) for coping of poles complete in cluding necessary form work, all as specified and directed by Engr-in-Charge.
Lightning arresters for non linear resistance type for 11 KV normal discharge count 5 Amps and high current impulse withstand 65 Kilo Amps conforming to IS-3070 Part-I for OH line including bracket, clamps, nuts and washers in repair complete all as specified and directed by Engineer -in-Charge.
Cross arms of any sizes with drilled hole (hot and cold etc) in position M.S. work including MS nut and bolts, washers and two coats of aluminium paint over one coat of redoxide primer, all as specified and directed by Engineer-in-Charge.
Cutting/ trimming of tree branches not exc 10cm girth touching/approaching the HT overhead lines upto 3 metre width on each side with hacksaw/axe to clear the HT line including disposal of trimmed branches 100 Metre away inside the cantonment area & clearing site complete all as specified and directed by Engineer-in-Charge.
Remoing of existing stone aggregates from 33 KV sub station upto 15cm deep including unwanted grass and refilling the same after complete cleaing entire satisfaction of Engr-in-charge complete all as specified and directed.
Supply and spreading stone aggregates of size 20mm evenly at outdoor 33/11 KV sub stations after removing uprooting of tiny trees, bushes, beeds, grass, elephant grass, removing poly bags, brick bats, stone pebbles and other debris etc complete all as specified and directed by Engr-in-charge.
vijay kumar gupta and co
proach associates
MOHAN LAL AND SONS
K S BUILDERS
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .