Loading…
Loading…
| # | Company | Status |
|---|---|---|
| 1 | Admitted-Finance | Admitted-Finance |
| 2 | Admitted-Finance | Admitted-Finance |
| 3 | Admitted-Finance | Admitted-Finance |
| 4 | Admitted-Finance | Admitted-Finance |
Tender Value
Refer Docs
EMD Value
₹8,400
Closing Date
14 Jun 2024, 11:00 amClosed
SO1 (Works)
DIMAPUR PIN 797112
Repair, Servicing and Refilling of Gas, Change of Spare parts for existing Air Conditioner of HQ 6 Sector Assam Rifles at Kashiram Basti.
2024_ARMHA_809895_1
I.15032/NIT/Engr/MW/6 Sect/2024-25/86
Open Tender
Civil Works - Others
Item Rate
240 days
Dimapur
2 documents required · 2 mandatory
₹1,000
Yes
DIG AR, 6 SECTOR AR
₹8,400
27 Jun 2024
5 Jun 2024
15 Jun 2024
5 Jun 2024
14 Jun 2024
5 Jun 2024
5 Jun 2024 - 14 Jun 2024
SCHEDULE ‘A’ PART - I (Repair of Air Conditioner)
M & L for Gas refilling and charging of R-22 refrigerant to the 1.50 Ton capacity Split type AC, including testing of leak the complete system as specified and as per direction of Engineer - in - Charge.
M & L for Gas refilling and charging of R-22 refrigerant to the 2 Ton capacity Split type AC, including testing of leak the complete system as specified and as per direction of Engineer - in - Charge.
M & L for Gas refilling and charging of R-22 refrigerant to the 1.5 Ton capacity Window Type AC, including testing of leak the complete system as specified and as per direction of Engineer - in - Charge.
M & L for Gas refilling and charging of R- 32 refrigerant to the 1.5 ton capacity Split Type AC, including testing of leak the complete system as specified and as per direction of Engineer - in - Charge.
M & L for Gas refilling and charging of R- 32 refrigerant to the 2 ton capacity Split Type AC, including testing of leak the complete system as specified and as per direction of Engineer - in - Charge.
Dismantling, Taking down carefully from the installed position and re installing in its original position and testing on completion of proper servicing complete all as directed by the Engineer – in – Charge of 1.5 Ton capacity Split type AC.
Dismantling, Taking down carefully from the installed position and re installing in its original position and testing on completion of proper servicing complete all as directed by the Engineer – in – Charge of 2 Ton capacity Split type AC.
Disconnect and remove unserviceable main PCB/display PCB and Supply and fixing New main PCB/display PCB suitable for existing model for 1.5 Ton capacity Split type AC (Display PCB) AC complete all as specified and as per direction of Engineer – in – Charge.
Disconnect and remove unserviceable main PCB/display PCB and Supply and fixing New main PCB/display PCB suitable for existing model for 1.5 Ton capacity Split type AC (Inverter type) AC complete all as specified and as per direction of Engineer – in – Charge.
Disconnect and remove unserviceable main PCB/display PCB and Supply and fixing New main PCB/display PCB suitable for existing model for 2 Ton capacity Split type AC (Display PCB) AC complete all as specified and as per direction of Engineer – in – Charge.
Disconnect and remove unserviceable main PCB/display PCB and Supply and fixing New main PCB/display PCB suitable for existing model for 2 Ton capacity Split type AC (Inverter type) AC complete all as specified and as per direction of Engineer – in – Charge.
Disconnect and remove unserviceable main PCB/display PCB and Supply and fixing New main PCB/display PCB suitable for existing model for 1.5 Ton capacity Window Type AC (Display PCB) AC complete all as specified and as per direction of Engineer – in – Charge.
Disconnect and repair of main PCB/display PCB and re fixing of repaired main PCB/display PCB suitable for 1.5 Ton capacity Split type AC (Display PCB) complete all as specified and as per direction of Engineer – in – Charge
Disconnect and repair of main PCB/display PCB and re fixing of repaired main PCB/display PCB suitable for 2 Ton capacity Split type AC (Display PCB) complete all as specified and as per direction of Engineer – in – Charge
Disconnect and repair of main PCB/display PCB and re fixing of repaired main PCB/display PCB suitable for 1.5 Ton capacity Window Type AC (Display PCB) complete all as specified and as per direction of Engineer – in – Charge
Taking out the burnt fan motor from the 1.50 Ton capacity Split type AC and supply and fixing new fan motor suitable for existing model complete all as specified and as per direction of Engineer – in – Charge
Taking out the burnt fan motor from the 2 Ton capacity Split type AC and supply and fixing new fan motor suitable for existing model complete all as specified and as per direction of Engineer – in – Charge
Taking out the burnt fan motor from the 1.50 Ton capacity Window Type AC and supply and fixing new fan motor suitable for existing model complete all as specified and as per direction of Engineer – in – Charge
Taking down unserviceable blower motor (for Indoor unit) of 1.50 Ton capacity Split type AC and supply and fixing new blower motor suitable for existing model of indoor unit of split type AC, including necessary connections and testing on completion complete all as specified and as per direction of Engineer – in – Charge.
Taking down unserviceable blower motor (for Indoor unit) of 2 Ton capacity Split type AC and supply and fixing new blower motor suitable for existing model of indoor unit of split type AC, including necessary connections and testing on completion complete all as specified and as per direction of Engineer – in – Charge.
Taking down unserviceable swing motor of 1.5 ton/2 ton capacities split type AC and supply and fixing new swing motor suitable for existing model of indoor unit of split type AC including necessary connections and testing on completion complete all as specified and as per direction of Engineer – in – Charge.
Taking down unserviceable capacitor from Split type/Window type AC and supply and fixing New Capacitor (50/55 MFD) , including testing on completion etc complete all as specified and as per direction of Engineer – in – Charge.
Taking down unserviceable capacitor from Split type/Window type AC and supply and fixing New Capacitor (60 MFD) , including testing on completion etc complete all as specified and as per direction of Engineer – in – Charge.
Disconnect and remove unserviceable 1.50 Ton capacity Split type AC compressor and Supply and fixing of new rotary/reciprocating compressor including brazing the suction/discharge lines suitable for existing model following capacity ACs and testing on all as specified and as per direction of Engineer – in – Charge
Supply and fixing on Wall MS factory made pre painted bracket for Out door Unit fixed with Nut bolt/ Screw.
Supply and fixing of copper gas pipe ½” nominal bore
Supply and fixing of copper liquid pipe ¼ ” nominal bore
Providing and fixing 20 mm nominal dia CPVC pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in Charge for Internal work, Exposed on wall
M/S. MAHESHWARI CONSTRUCTION
M/S. SHIVAM ENTERPRISES
aarav enterprises
stage.html
html • 0.03 MB
tech_bid_open.pdf
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .