Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹17.6 LAccepted-AOC 129 A NICHLI CHOWKI DEVI NAGAR SECTOR 32 PANCHKULA HARYANA 134109 | PANCHKULA | HARYANA | 134109 | L1 | Accepted-AOC Accepted | |
| 2 | L2₹17.8 L+₹24,048 (1.37%)Rejected-Finance | L2 | Rejected-Finance Rates are high | |
| 3 | L3₹18.0 L+₹39,078 (2.22%)Rejected-Finance | L3 | Rejected-Finance Rates are high | |
| 4 | L4₹18.3 L+₹69,138 (3.93%)Rejected-Finance 1442 1 NANADANPURA BABINA CANTT TEHSIL DISTT JHANSI UP | BABINA | JHANSI | UP | L4 | Rejected-Finance Rates are high | |
| 5 | L5₹18.5 L+₹90,180 (5.13%)Rejected-Finance 19 SAINIK COLONY BAIRAGARH BHOPAL MP 462 030 | BHOPAL | MADHYA PRADESH | 462030 | L5 | Rejected-Finance Rates are high |
Tender Value
₹19.4 L
EMD Value
₹38,800
Closing Date
10 Feb 2020, 12:00 pmClosed
GE MIS MHOW
GE MAINT INF SCHOOL, 75 MALL ROAD MHOW
MANNING AND OPERATION OF CENTRAL TYPE AC PLANT AT MHOW FORT UNDER GE MAINT INF SCHOOL MHOW
2020_MES_316731_1
GE MIS MHOW/65 OF 2019-20
Open Tender
Miscellaneous Works
Item Rate
334 days
GE MIS MHOW
Please refer Tender documents.
8 documents required · 8 mandatory
₹500
GE MIS MHOW
₹38,800
Yes
25 Aug 2020
21 Jan 2020
12 Feb 2020
27 Jan 2020
10 Feb 2020
4 Feb 2020
Amount
Manning and operation of 05 Nos DG Sets of capacity 01 x 100 KVA, 01 x 380 KVA, 01 x 160 KVA, 01 x 320 KVA & 01 x 500 KVA alongwith connected control panels and equipment round the clock in three shifts of eight hrs from 0600hrs to 1400hrs, 1400hrs to 2200hrs and 2200hrs to 0600hrs by deploying one high skilled operator in each shift including operation of DG Sets in case of electric power failure and maintaining of log sheets at Inf School complete all as specified and as directed by the Engr-in-Charge.
Manning and operation of 04 Nos DG Set of capacity 1 x 180 KVA and 3 x 75 KVA alongwith connected control panels and equipment round the clock in three shifts each of eight hrs from 0600hrs to 1400hrs, 1400hrs to 2200hrs and 2200hrs to 0600hrs by deploying one high skilled operator in each shift including operation of DG Sets in case of elect power failure and maintaining the log sheets at AMU Node complete all as specified and directed by Engr-in-charge.
Manning and operation of Central type AC plant at MH (capacity 3 x 21 TR) with connected equipment by deploying one Ref Mech in one shift for three shifts ( each shift of eight hours) 0600 to 1400 hrs, 1400hrs to 2200hrs and 2200hrs to 0600hrs including maintenance of daily log sheet all as specified and directed by Engr-in-chage.
Notes :- (for Sl No 1 to 3) 1. The operator must be a skilled FGM /Ref Mech subject to ITI qualified in appropriate trade or fiver years of experience in concerned operation field and fully conversant to maintenance and operation /handling of DG sets and electrical switchgears. 2. The operator must adhere with the dress code as directed. 3. The operator has to attend the telephone and maintain the record. 4. The operator must be smart in conversation and well behaved. 5. The contractor is responsible to the following :- (a) Maintenance of Batteries and battery charger (The cost of distled water and electrolite and other materials required for maintanance of batteries is deemed to be included in the quoted rate) (b) Collection of FOL (Fuel, oil and lubricants) from AGE E/M No 1 FOL Store for maintenance and operation of DG Set. (Transport will be provided by the deptt) (c) Cleaning and upkeep of DG set/AC Plant installation and surrounding area if not found satisfactorily Penal recovery of 500/- per day will be charged. (d) The DG sets are installed in scattered locations in the compound of Inf School, AMU Node, & Inf Musuem. The contractor's operator must be smart to maintain and operation of all DG Sets and keep their records.
Notes :- For all Items of BOQ ; If the quoted amount is less than the estimated cost of the work i.e. 19.40 Lakhs, then the lowest bidder will have to deposit FDR/BGB in favour of Accepting Officer within 07 days of opening of finacial bid for the difference in estimated cost i.e. 19.40 Lakhs & quoted amount. In case the said FDR/BGB is not submitted within stipulated period mentioned above, the contractor shall be banned for 06 months & his bid will be rejected. The said Amt deposited by the lowest bidder will be released after completion of work.
Vinayak Trading House
MODI CORPORATION
M/S SHIVA TRADERS
SUNIL ENTERPRISE
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .