Loading…
Loading…
Tender Value
₹41.1 L
EMD Value
₹82,300
Closing Date
13 Jul 2026, 3:00 pm
Similar tender results from the same govt authority in the past 3 years.
Provision of lift TDL-FZD section. (Phase-I). Provision of lift PRYJ-CNB section. (Phase-I). Provision of lift CNB-ETW section. (Phase-I). Provision of Lifts at Subedarganj Railway Station Prayagraj Division. Provision of 04 Nos. lift in GM NCR office Complex Subedarganj. Provision of 02 Nos. lift in old GM building/ CPRO office PRYJ. Provision of Lifts for Amrit Bharat and other important stations over Prayagraj Division.
ELG-32-2627
ELG-32-2627
Open
6 Months
Prayagraj, Uttar Pradesh
₹0
₹82,300
19 Jun 2026
19 Jun 2026
29 Jun 2026
Item Breakup - 1-NS Schedule
Supply and laying of B class, 50 mm dia, GI pipe Metre of Approved make for cable riser/road crossing as required and as per relevant technical specification. Inspection by- Consignee. PRAYAGRAJ DIVISION-ELECTRICAL/NORTH CENTRAL RLY
Collecting, Transporting from SSE/PS store to site, Metre laying, testing, and commissioning of LT cable of size , direct in ground (Including excavation, sand cushioning, protection brick covering and refilling the trench etc.), direct in RCC/Metal pipes in rod/track crossings and on surface/in wall/in concrete floor by cutting recessed and finished originally as required per relevant technical specifications.(Cable will be supplied by Railway).
Drilling of charges of cable in road crossing for laying 110 mm dia HDPE pipe through it.
Supply a n d laying o f HDP E Pipes (Upto P N 8.0 Metre Pressure Rating Material Grade: P E 6 3 , Pressure Rating: P N 8.0, Nominal Dia(mm): 110) as per relevant IS suitable for HT/LT XLPE cable & as r e q u i r e d a n d as per r e l e v a n t technical specification. Inspection by- RITES.
Termination of LT XLPE cables of following sizes Job with proper size of approved make crimping sockets/ lugs/ PG clamps as required including testing and commissioning.
Supply, erection, testing and commissioning of Numbers 140.00 single earth electrode of 50 mm. dia 4000mm long GI pipe class B complete with earth box with CI cover hinged to CI frame including connection from earth electrode to MDB/SDB/poles/with 8 swg GI wire/strip as per attached drawing.Inspection by- Consignee.
Supply, commissioning of maintenance free Earthing RDSO spec no. RDSO/SPN/197/2008 or Latest consisting of. Earth electrode of copper bonded high tensile low carbon steel rods, specially designed for electrical grounding as per RDSO Spec. No RDSO/SPN/197/2008 or latest. RDSO approved earth enhancing compound in 10 Kg pack - 05 No. Copper tape of 25mm x 6mm x 300mm with 99.9% purity - 2 Nos and another of 25mm x 6mm x 150mm to terminate one earth electrode Supply of insulated connecting cable as per RDSO Spec No RDSO/SPN/197/2008 or latest to connect equipment bus bar 10 meter each earth Installation of Unit Earth consisting materials covered in item 1 in accordance to RDSO Spec No RDSO/SPN/197/2008 or latest Digging of earth to the required depth Insertion of electrodes - 1 Nos Filling of earth enhancing compound, provision of exothermic weld connection on copper tape of 25mmx6mmx 150mm to the earth electrodes. (All materials tools and fixtures required for the weld to be arranged by the contractor) -5No. 25mm x 6mm x 150mm to the earth electrodes (All materials tools and fixtures required for the weld to be arranged by the contractor)- 1 No. Provision of exothermic weld connection on copper tape of 25mm x 6mm x 150mm to the earth electrodes (All materials tools and fixtures required for the weld to be arranged by the contractor) - 1 No. Provision of exothermic weld one to connecting cable to the earth electrodes and another to the copper tape to be fixed inside the Equipment/Relay rack/apparatus room (features for mounting the copper tape inside the relay room, weld materials, tool, fixtures and other materials required for the weld shall be arranged by the contractor). Inspection by- Consignee. PRAYAGRAJ DIVISION-ELECTRICAL/NORTH CENTRAL RLY
Design, manufacture, supply, erection, testing & Numbers commissioning of LT switch gear panel board of 2mm thick dia pressed CRC steel sheet panel shall be treated for anti corrosion treatment and finished with smoke gray paint as per technical specification No. Sr. DEE/G/ALD/Panel-94/113 . MCCB of 250 A, 36 kA Standard breaking capacity, 415 volt, 3 phase 4 pole .
MCCB of 125 A, 36 kA Standard breaking Numbers 106.00 capacity, 415 volt, 3 phase 4 pole .
03 Nos Indication lamps with suitable holder.
Supply, commissioning of Outgoing/Feeder Panel Mounted Multi-function meter with Accuracy Class 1 as per IEC 62053-21 or Class 0.5, 0.5S, 0.2, 0.2S as per IEC 62053-22.LED meter Cl 1 with RS485: of similar model No.WL440521OOOO of L&T. Meter should have following features built-in LED • Flush mounting 96 x 96 mm • True RMS measurement • Password protection provision for security • Site selectable for 3 Phase 4 wire, 3 Phase 3 wire, 1 Phase, CT Secondary 1A/5A, Universal Auxiliary Supply 80-300 VAC/DC, Input Voltage Measurement 50-500 VAC, • 64 samples/ cycle The Meter should be able to read/display following parameters Instantaneous Parameters (V1, V2, V3, V12, V23, V31, Avg (VLN, VLL), A1, A2, A3, Aavg, F, PF-1, PF-2, PF-3, PF (Avg) W1, W2, W3, W (total) VA1, VA2, VA3, VA (total) Cumulative Parameters (Import Wh, Import Vah, Import load hours, Reset (old) Cumulative parameters (Import Wh, Import load hours, Communication (RS485 Modus RTU) complete with all accessories.
Fabrication works and insulated Aluminum bus Job bars of 300 Amps capacity for phases & 150 Amps capacity for neutral. Bus bar shall be suitably insulated with heat shrinkable sleeves / epoxy coating/Insulating tap to withstand the test voltage of 2.5 KV. Copper strips for connection outgoing as well as incoming with suitable size be provided. LT Panel form item No. 08 to 12 will be Inspection by-RITES.
Fabrication works and insulated Aluminum bus Job bars of 500 Amps capacity for phases & 250 Amps capacity for neutral. Bus bar shall be suitably insulated with heat shrinkable sleeves / epoxy coating/ Insulating tap to withstand the test voltage of 2.5 KV. Copper strips for connection outgoing as well as incoming with suitable size be provided. LT Panel form item No. 08 to 11 and 13 will be Inspection by-RITES. Total 4113390.74
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
HTML
nit.pdf
NIT
2026_03_13GCCAdvanceCorrectionSlipNo_11.pdf
ATTACHMENT
2022_CE-I_CT_GCC-2022PolicyAdvancecorrectionslip1.pdf
ATTACHMENT
GCC correction
ATTACHMENT
CTIndianRailwaysStandardGeneralConditionsofContractApril-
ATTACHMENT
GCC_April-2022_2022__27_04_227.pdf
ATTACHMENT
Annexure-VA.pdf
ATTACHMENT
2022_12_13RBCE_CE-I-CTIndianRailwaysStandardGeneralConditionsofContractApril2022ACSNo_21.pdf
ATTACHMENT
2023_04_26RBCE_CE-I-CTIndianRailwaysStandardGeneralConditionsofContractApril-2022AdvanceCorrectionSlipNo_3ACS-31.pdf
ATTACHMENT
2023_08_07RBCE_CE-I-CTIndianRailwayStandardGeneralConditionsofContractApril-2022AdvanceCorrectionSlipNo_4ACS-4.pdf
ATTACHMENT
2023_10_20RBCE_CE-I-CTIndianRailwayStandardGeneralConditionsofContractApril-2022AdvanceCorrectionSlipNo_5ACS-5.pdf
ATTACHMENT
2023_12_21IndianRailwaysStandardGeneralConditionsofContractApril-2022AdvanceCorrectionSlipNo_6ACS-6.pdf
ATTACHMENT
Likelysourceofsupply.pdf
ATTACHMENT
ACS_7to10.pdf
ATTACHMENT
tenderdocument_1.pdf
ATTACHMENT
Download all tender documents and submit your bid