Loading…
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Tender Value
Refer Docs
EMD Value
₹5,500
Closing Date
27 Jan 2026, 1:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Executive Engineer (A-M) Burdwan (A-M) Division
Kalna Road, Near Agril Farm, Purba Bardhaman- 713101
Repairing and maintenance of Electric Lighting system and installation of new Lighting arrangement within Burdwan(AM) Sub Division office and store Compound of Purba Bardhaman District under EE(AM) Burdwan(AM) Div
2026_WRDD_990475_3
WBWRDD EEAM BDN eNIT-35 (Sl No 01-03) NP 2025-26
Open Tender
Miscellaneous Works
Percentage
30 days
Burdwan AM SD, Burdwan Block
Please refer Tender documents.
3 documents required · 3 mandatory
₹5,500
2 Feb 2026
19 Jan 2026
29 Jan 2026
19 Jan 2026
27 Jan 2026
19 Jan 2026
Repairing and maintenance of Electric Lighting system and installation of new Lighting arrangement within Burdwan(A-M) Sub- Division office & store Compound of Purba Bardhaman District under Executive Engineer(AM) Burdwan (AM) Division during the Financial Year 2025-26 under Non plan.( Please see the details in Sheet Barge)
BoQ_Ver3.0
Bidder Name :
PRICE SCHEDULE (This BOQ template must not be modified/replaced by the bidder and the same should be uploaded after filling the relevent columns, else the bidder is liable to be rejected for this tender. Bidders are allowed to enter the Bidder Name and Values only )
Supply and fixing of greenline V2 street light (115 Watt) complete with all accessories to be fixed /projected from the wall of the building or on pole incl. making holes/providing clamping arrangement & necy. GI reducer as required. S&F 40 mm GI pipe (ISI-Medium) quality 1.5 mts. average length having suitable bend S&F necy. length of 1.5 sqmm PVC insulated single core stranded annealed copper wire and making connections as required and mending good damages to wall incl. painting etc.Make: Philips, 115 watt. VIDE PAGE :125; ITEM :5.3 F.11.0.1 USOR / I & W (M & E)
Supply and fixing of smart bright essential street light Watt) complete with all accessories to be fixed /project from the wall of the building or on pole incl. making hol providing clamping arrangement & necy. GI reducer required. S&F 40 mm GI pipe (ISI-Medium) quality 1.5 m average length having suitable bend S&F necy. length of sqmm PVC insulated single core stranded annealed copp wire and making connections as required and mendi good damages to wall incl. painting etc.Make: Philips, 68 watt. VIDE PAGE :118; ITEM :5.3 H.8.0.6 USOR / I & W (M & E)
Supplying of Swaged Steel Tubular pole (IS 2713, Pt. II 1980) for following designation and of following dimensions:410-SP-1; 7.0 mtrs: 62.00Kg [SOR UDMA.ELECTRIC-MECH.WORK(VOL-1)OCT18 A-series Item 1(d)]
S/F double arm projected lamp bracket (Single pip bending) of 50mm (2") dia G.I. pipe (ISI medium) of 2.5 mtr long each having 105 degree curvature with reducing socket to be fitted at the top of the pole with bolts, nuts clamps etc. as required[SOR UDMA.ELECTRIC-MECH.WORK(VOL-1)OCT18 A-series Item 23]
S/F projected lamp bracket of G.I. pipe (I.T.C.) (Class-B of 40 mm bore dia and 1.5 m) length with tie rod and “S” type ornamental scroll to be fitted at a point 600 mm from the top of the pole by means of clamps, bolts, nuts etc. as required. [SOR UDMA.ELECTRIC-MECH.WORK(VOL-1)OCT18 A-series Item 18]
Erection of Single Steel tubular pole of length as given below with/without sole plate & Cap etc. in CC foundation (Proportion and dimension indicated below), having 600x600x150 mm thick CC (4:2:1) base block below sole plate/pole with hard jhama metal including CC (6:3:1) muffing 0.30 mts. dia and 0.30 mts. above ground level including 3 mm thick neat cemented finish and GI earth bolt after making drilled holes etc. on pole & carriage of pole upto 1.6 Km from Store to work-site including filling up the excavated earth pit with shifted soil and ramming properly. a) Upto 9.0 mtr. Size 0.6x0.6x1.70 mts (PWD elec. Sh. 2017 Page-H 1, item-1 )
Supplying & Fixing 40 mm dia 3.20 metre long Vertical Type service bracket for carrying 2 wires and an earth wire complete with Galv. clamp for stay, insulators etc., 7/14 SWG stranded Galv. (Hot Dip) wire for stay with 230x13 mm dia straining serews, 75x88 mm porcelain shackle insulators with Galv. (Hot Dip) strips etc. and painting (PWD elec. Sh. 2017 Page-H-6, item-I5 )
Painting of Steel Tubular Pole of lengths and no. of coats of paint, as given below with ready mixed paint/primer of approved make, and brand incl. preparation of surface by sand paper/emery paper, cleaning etc. for receiving fresh coat of paint (ii) 1st coat of synthetic enamel paint over the primer (PWD elec. Sh. 2017 Page-H-2, item-7A(ii) )
Painting of Steel Tubular Pole of lengths and no. of coats of paint, as given below with ready mixed paint/primer of approved make, and brand incl. preparation of surface by sand paper/emery paper, cleaning etc. for receiving fresh coat of paint (iii) 2nd coat of synthetic enamel paint over the 1st coat (PWD elec. Sh. 2017 Page-H-2, item-7A(iii) )
Earthing with 50 mm dia GI pipe 3.64 mm thick x 3.04 Mts. long and 1 x 4 SWG GI (Hot Dip) wire (4 Mts. long), 13 mm dia x 80 mm long GI bolts, double nuts, double washers incl. S & F 15 mm dia GI pipe protection (1 Mts. long) to be filled with bitumen partly under the ground level and partly above ground level driven to an average depth of 3.65 Mts. below the ground level as below:By ISI-Medium GI pipe (PWD elec. Sh. 2017 Page-G-1, item-2a )
Wiring with 1.1 KV grade single core PVC insulated stranded Copper wire in EI conduit/GI conduit and painting 2x6 sqmm wire in 19 mm conduit incl. S&F 1x14 SWG GI ECC PWD elec. Sh. 2017 Page-E-1, item-1d )
Wiring with 1.1 KV grade single core PV insulated stranded Copper wire in EI conduit/GI conduit and painting 2x2.5 sqmm wire in 19 mm conduit incl. S&F 1x14 SWG GI ECC(PWD elec. Sh. 2017 Page-E-1, item-1b )
Excavation of soil for installation of Earth Electrode and filling & ramming. (a) For Soft Soil (PWD elec. Sh. 2017 Page-G-1, item-1,a )
Laying of one No. cable upto 35 sqmm in underground trench 460 mm wide x 760 mm average depth, with brick protection on the top of the cable with 8 (eight) Nos. bricks per metre, including filling the space between the brick & cable and also the trench with shifted soil, leveling up and restoring surface duly rammed (PWD elec. Sh. 2017 Page-F-2, item-1a )
Supplying & Fixing GI waterproof type looping cable box size200x150x100 mm deep having 4 mm thick comprising of one 250V 15 A kit-kat fuse unit, one NL on porcelain insulator, onecompression type brass cable gland for upto 2- core 16 sqmmPVC/A cable and having lined with rubber gasketted GI top coverwith brass machine screws etc., earthing terminal with lug, onsteel tubular pole near base, including S&F 40x6 mm thick, MSclamps with bolts, nuts etc. including painting with anticorrosivepaint (PWD elec. Sh. 2017 Page-H-5, item-H,5 )
Supplying and fixing 240/415 V MCB of Breaking capacity 10kA & C characteristics on din rail of existing DBs and necessary connection Legrand 6-32 A SP (PWD elec. Sh. 2017 Page-D-6, item-7 )
Sub-Total
Add GST @18%
Cost of civil works excluding Labour welfare cess
Add Labour welfare cess @ 1%
Cost of civil works including Labour welfare cess
Total =
Say Rs.
Two Lakh Sixty Nine Thousand Nine Hundred & Three Only
stage.html
html • 0.02 MB
cancelled_1.pdf
pdf • 0.13 MB
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 1.24 MB
Tendernotice_2.pdf
PDF • 1.87 MB
BOQ_2421247.xls
BOQ • 0.35 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .