Tender Value
₹72.9 L
EMD Value
₹1.3 L
Closing Date
17 Dec 2019, 6:00 pmClosed
CWE (AF) Palam
HQ CWE (AF) Palam Delhi Cantt-10
CA NO CWE/PM/SP-23/2019-20 SPECIAL REPAIRS TO STAFF QUARTERS OF HQ WAC AT SUBROTO PARK
2019_MES_301140_1
CA NO CWE/PMSP-23/2019-20
Open Tender
Civil Works
Item Rate
270 days
GE (AF) Subroto Park Delhi Cantt
Please refer Tender documents.
7 documents required · 7 mandatory
₹1,000
GE (AF) Subroto Park
₹1.3 L
Yes
9 Jan 2020
26 Nov 2019
19 Dec 2019
26 Nov 2019
17 Dec 2019
10 Dec 2019
Amount
BOQ PART-I (B/R WORKS)
Taking down chowkats or frames with shutters (without taking off shutters from the frame) area exc 1.5 sqm and not n.exc 4.0 sqm complete, all as specified and directed by Engineer-in-Charge.
All as per item No 1.01 here-in-beofre but not exceeding1.5 Sqm.
Taking down door shutter of any description exc. 1.0 Sqm but n. exc 2.0 Sqm each complete, all as specified and directed by Engineer-in-Charge.
M&L for cutting holes in the brick wall built in cement mortar or cement lime mortar for inserting hold fasts /bracket for cooler stand and making good to the dismantled portion in cement mortar 1:3 or cement concrete type B-1,1:2:4 (using 20mm graded stone aggregate) as required not exceeding half brick depth complete, all as specified and directed by Engineer-in-Charge.
Dismantling of wrought iron or mild steel works of any description, size or in any position including door, gates etc. complete, all as specified and directed by Engineer-in-Charge.
S & F rolled mild steel framed work as in doors, chowkats or gates of angle or other section, grills confirming to Fe 410 - W, with gusset plates, rails braces, lugs etc complete, all as specified and directed by Engineer-in-Charge.
S&F factory made wire gauzed i.e. panel will be of wire gauze (08 panels) PVC door shutter 30 mm thick (style) consisting of frame made out of M.S. tubes for top & bottom rails. M.S. frame shall be covered with heat moulded prelam PVC ‘C’ channel having a PVC sheet strip of 20mm width stuck inside with solvent cement for stiles and prelam PVC sheets for top rail, lock rail & bottom rail on either side & as gap insert for top rail & bottom rail; The wire gauze shall be wrapped on an additional square 8mm M.S. solid tube and this tube shall be welded to M.S. tubes fixing in frame at site as per specification including fixing of stainless steel wire cloth 0.45 mm nominal dia of wire and average width of aperature 1.18 mm complete, all as specified and directed by Engineer-in-Charge.
S&F 35 mm thick flush shutters, solid core construction, with block board core and plywood face panels, commercial type on both sides complete, all as specified and directed by Engineer-in-Charge.
S&F solid moulded PVC door frame of size 50mmx47mm made out of 5mm thick single side prelam PVC sheet used instead of plain colour PVC sheet & edges will be painted to match with prelam sheet PVC sheet reinforced with M.S. square tube, supplying & fixing in opening as per specification complete, all as specified and directed by Engineer-in-Charge.
S&F factory made solid PVC moulded door with wood free EPS core shutter 28 to 30mm thick (stiles) with 2, 4, or 6 raised panel design with 2mm thick moulded prelam PVC sheet on the front face & 2mm plain colour PVC sheet on back face, fixing in frame at site as per specification complete, all as specified and directed by Engineer-in-Charge.
S&F windows/ ventilators fabricated from 0.60mm thick roll formed section made of galvanised steel powder coated (base steel as per IS-513"D" quality) galvanised as per IS-277 with zinc of 120 gm/Sqm . Windows /ventilators having frame suitable for dual shutter i.e. inner and outer shutter with grill, glazed shutter with 4.0mm thick glass, mesh shutter with 32 gauge stainless steel mesh, 6mmx12mm flat iron with 10mm square bar M.S. grill and all fitting, fixtures accessories complete, all as specified and shown in drawing No CEAF/STD-191/2014, sheet 1/2 & 2/2 dated 11.12.14(4000 series). Note : Glazed shutter with 4.00mm thick glass, mesh shutter with 32 gauge stainless mesh and M.S. grill as per Note Nos. 10, 11 and 13 of above mentioned drawing deemed to be inclusive in the rate quoted for unit.
S&F windows/ ventilators fabricated from 0.60mm thick roll formed section made of galvanised steel powder coated (Base steel as per IS-513"D" quality) galvanised as per IS-277 with zinc of 120 gm/Sqm . Windows /ventilators having frame suitable for single shutter with grill, glazed shutter with 4.0mm thick frosted glass, 6mmx12mm flat iron with 10mm square bar M.S. grill and all fitting, fixtures accessories complete as specified and shown in drawing No CEAF/STD-191/2014, sheet 1/2 & 2/2 dated 11.12.14(3000 series). Note : Glazed shutter with 4.00mm thick glass, Mesh shutter with 32 gauge stainless mesh and M.S. grill as per Note Nos. 10,11 and 13 of above mentioned drawing deemed to be inclusive in the rate quoted for unit.
M&L for fixing veneered particle block board 18/19 mm thick, grade 1 quality, exterior grade, commercial type fixed with screws to timber frame as in cupboards, shutters, shelves, pelmet box etc. including fixing 18 mm wide 6 mm thick beading of Ist class hard wood (Teak) complete, all as specified and directed by Engineer-in-Charge.
M&L for preparation of new or previously untreated wooden surfaces of any description over 10 cm in width or girth not otherwide described and applying two coats of synthetic enamel paint over a coat of pink primer complete, all as specified and directed by Engineer-in-Charge.
M&L for preparation of old painted wooden surface of any description, not otherwise described over 10cm width or girth and applying one coat of synthetic enamel paint complete, all as specified and directed by Engineer-in-Charge.
S&F 300 mm mild steel ordinary rat tail rod pattern springs including roller and roller plate complete, all as specified and directed by Engineer-in-Charge.
S&F 100 mm long butt hinges, medium weight, cold rolled, mild steel alloy with galvanized complete, all as specified and directed by Engineer-in-Charge.
S&F 150 mm long aluminium door handle, cast type, anodized complete, all as specified and directed by Engineer-in-Charge.
S&F 100 mm long mild steel pressed handles, oval type, stove enamelled black complete, all as specified and directed by Engineer-in-Charge.
S&F of 150 mm long mild steel barrel tower bolts, stove enamelled black, with bright bolt and fixed complete, all as specified and directed by Engineer-in-Charge.
S&F door stopper of aluminium, alloy body and tongue with hard drawn steel spring fixed in floors of 140 mm overall length of cover plate complete, all as specified and directed by Engineer-in-Charge.
S&F 250 mm long mild steel sliding door bolts, plate type, stove enamelled black, with bright bolt not less than 12mm dia with and including a minimum of 6 bolts and nuts, four on bolt plate and two on staple plate and fixed complete, all as specified and directed by Engineer-in-Charge.
Demolition to brick work or stone/boulder masonry, built in cement mortar complete, all as specified and directed by Engineer-in-Charge.
M&L for brick work with subclass 'B' bricks (having crushing strength @ 75 kg/Sqcm), straight or curved on plan exc 6 M mean radius built in cement mortar 1:6 complete, all as specified and directed by Engineer-in-Charge.
M&L for Brick work with sub class ‘B’ bricks (having crushing strength @ 75 kg/Sqcm), straight or curved on plan to any radius in half brick thick walls built in cement mortar 1:4 complete, all as specified and directed by Engineer-in-Charge.
Demolition of reinforced cement concrete of any description and in any position not otherwise specifically provided for and remove the debris complete, all as specified and directed by Engineer-in-Charge.
M&L reinforced cement concrete M-25 as in slabs supported on walls, beams and columns in floors, roofs, landings, balconies, canopies, deck slabs and in shelves and the like complete,all as specified and directed by Engineer-in-Charge.
M&L TMT bars 6mm to 8mm dia, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends & binding with & including mild steel wire (annealed) not less than 0.9mm dia or securing with clips quality complete, all as specified and directed by Engineer-in-Charge.
Form work to soffits of suspended slabs such as roof slabs, floor slabs, landings and similar work, not exceeding 200mm thick for fair finished surfaces of concrete flat complete, all as specified and directed by Engineer-in-Charge.
Form work to edges of concrete flats, treads, breaks in floors, window cills, concrete railings, openings in concrete walls, floor & roofs n. exc 5 cm wide & sides of RCC/PCC bands in walls, horizontal or sloping & similar work n.exc 10cm wide roughed finished surface of concrete complete, all as specified and directed by Engineer-in-Charge.
M&L 18-20 mm thick granite (of any type) work (table rubbed and polished) in steps, jambs, pillars, window cills, cooking platforms, WHB counter and like in 15mm cement mortar screed bed in cement mortar 1:4 including pointing in white cement (1:2) using marble dust with admixture of pigment to match with shade of granite including cutting for WHB etc complete, all as specified and directed by Engineer-in-Charge.
S & F as in repairs, sinks with drainage board made of stainless steel 1mm thick kitchen or laboratory with plugs, washers and wastes, including bedding in cement mortar on to dwarf wall or including fixing cantilever brackets and connecting union to pipe, overall size 915mm x 460mm bowl size 410mm x 330mm x 160mm complete, all as specified and directed by Engineer-in-Charge.
S&F as in repairs, stainless steel rack for kitchen utensil made out of 22 gauge sheet & overall size 900mm x 750mm x 200mm fixed to wall with screws complete, all as specified and directed by Engineer-in-Charge.
M&L for preparation of old painted steel surface including removal of rust of any description, not otherwise described over 10cm width or girth and applying one coat of synthetic enamel paint complete, all as specified and directed by Engineer-in-Charge.
M&L two coats synthetic enamel paint over a coat of red oxide primer on new steel surfaces of any description not otherwise described over 10 cm width or girth including preparation of surfaces complete, all as specified and directed by Engineer-in-Charge.
Dismantling of plain or corrugated steel/aluminium sheeting, any gauge, thickness, including Nainital or similar pattern roof coverings complete, all as specified and directed by Engineer-in-Charge.
S&F pre- painted galvalume aluminium zinc coating GI based corrugated steel sheet 0.50mm thick of an colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws complete, all as specified and directed by Engineer-in-Charge.
Dismantling to brick tiles or terracing tiles single layers laid on roof including removing the debris including mortar out side defence land complete, all as specified and directed by Engineer-in-Charge.
Racking out joints/pointing to brick tiles laid in cement mortar as in roofs etc. including removing grass roof if any complete, all as specified and directed by Engineer-in-Charge.
Flush pointing to brick tiles laid as in roofs etc. in cement mortar (1:3) mixed with 5 % crude oil by weight of cement complete, all as specified and directed by Engineer-in-Charge.
M & L for 40 mm thick brick tiles over bedding layers of 15 mm thick cement mortar (1 : 6) and jointed grounded flush in cement sand mortar (1 : 3 mixed with 5 % crude oil by weight of cement) complete, all as specified and directed by Engineer-in-Charge.
M&L for plain cement concrete type B-0, 1:2:4 (12.5 mm graded stone aggregate) as in roof padding complete, all as specified and directed by Engineer-in-Charge.
M & L for screed bedding 10 mm thick in cement mortar 1:4 on fair faces of brick work or concrete surfaces for backing of APP membrane finished even and fair using extra cement with water proofing compound complete, all as specified and directed by Engineer-in-Charge.
M&L for preparation of plastered/concrete surfaces of roof and applying the under mentioned course of roof treatment complete, all as specified and directed by Engineer-in-Charge:- (a) Surface shall be thoroughly wire brushed, cleaned, washed, dried up properly and apply evenly a bituminous oil based primer coat conforming to IS @0.4 ltr /Sqm over concrete / plastered roof surface. (b) Applying a coat of industrial bitumen grade 85/25 @ 1.20 kg/sqm over bituminous primer. (c) Laying of 3mm thick APP membrane sheet (min weight 3 Kg/Sqm) consisting of a core of 160 gms/Sqm polyester non woven fabric mat protected on both sides with a high quality polymeric asphaltic mix again protected with thermo fusible HMHDPE FILM on dried primed surface by torch application method. APP membrane will normally be laid in length at right angle to the direction of slope. The over lap shall be minimum 100mm on longitudinal direction and 150mm on the transverse direction including cuttings, grooves etc. (d) Membrane bonded completely to the substrate & the over laps are then scaled/fused by flame. (e) Painting with two coats of water proofing paint with aluminium finish. Note : This treatment shall be done by the approved authorised applicators and guarantee of treatment shall be for 10 years in favour of GE (AF) Subroto Park Delhi Catt-10.
Taking down cement plaster etc on brick wall or stone walls etc including raking out joints, hacking for key, scrubbing down with water etc and disposed off unserviceable materials to out side MOD land complete, all as specified and directed by Engineer-in-Charge.
M&L for rendering 15 mm thick cement mortar 1:6, on fair faces of brick work or concrete surfaces on wall surface even and fair without using extra cement complete, all as specified and directed by Engineer-in-Charge.
M&L for rendering 5 mm thick in cement mortar (1:3) on fair faces of brick work or concrete surfaces in ceiling complete, all as specified and directed by Engineer-in-Charge.
M&L for rendering 15 mm thick cement mortar 1:4, on fair faces of brick work or concrete surfaces on wall surface even and fair without using extra cement complete, all as specified and directed by Engineer-in-Charge..
Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing), removing serviceable tiles to store and rubbish off the premises complete, all as specified and directed by Engineer-in-Charge.
S&F Non skid ceramic tiles 7 to 8mm thick (squares/ rectangular) area of each tile exceeding 0.11 sqm but not exceeding 0.18 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match over 15mm thick screed bed in cement mortar (1:6) complete, all as specified and directed by Engineer-in-Charge.
S&F non skid ceramic tiles 7 to 8 mm thick (squares/rectangular) area of each tile exceeding 0.11 Sqm but not exceeding 0.18 Sqm as in skirting etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match over 10mm thick rendering in cement mortar 1:4 complete, all as specified and directed by Engineer-in-Charge.
M&L for 25mm thick cement concrete type B-1, 1:2:4 (20mm graded stone aggregate) as in sub base floor complete, all as specified and directed by Engineer-in-Charge.
M&L glazed ceramic tiles in vertical surface 300 mm x 450mm x 7 mm thick set and jointed in neat cement slurry and pointed in white or colour cement to match thick set and jointed in neat cement slurry and pointed in white or colour cement to match including rendering 10 mm thick in cement mortar 1:4 complete, all as specified and directed by Engineer-in-Charge.
M&L for 18-20 mm thick machine cut kota stone slab mirror finish polish over and including 15mm screed bed in cement mortar 1:4 laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing complete, all as specified and directed by Engineer-in-Charge.
All as per item No 1.54 here-in- above but as in riser of steps, skirting, dado and pillar over 10 mm thick rendering in cement mortar 1:4 complete, all as specified and directed by Engineer-in-Charge.
M&L for rounding to edges of stone slabs one edge, such as in steps, cooking platform, and other similar situations complete, all as specified and directed by Engineer-in-Charge.
S&F as in repairs, PVC (SWR) pipes 110 mm single socketed, in any length with solvent cement joints fixed to walls/laid in floors including stack clamps of stainless steel with bolts & nuts etc complete, all as specified and directed by Engineer-in-Charge.
All as per item No 1.57 here-in-before but 75 mm dia complete, all as specified and directed by Engineer-in-Charge.
S&F as in repairs, PVC SWR floor trap with grating including jointing with solvent cement 75 mm dia complete, all as specified and directed by Engineer-in-Charge.
S&F PVC SWR bends 110 mm complete, all as specified and directed by Engineer-in-Charge.
S&F PVC SWR bends 75 mm complete, all as specified and directed by Engineer-in-Charge.
S&F PVC SWR Junction piece 75 mm single (single T) provided with access door equal or unequal complete, all as specified and directed by Engineer-in-Charge.
S&F 110 mm PVC SWR junction single (single T) provided with access door complete, all as specified and directed by Engineer-in-Charge.
S&F PVC SWR vent cowl of size 110 mm complete, all as specified and directed by Engineer-in-Charge.
S&F PVC SWR vent cowl of size 75 mm complete, all as specified and directed by Engineer-in-Charge.
Taking up or down 15mm bore steel tubing and connections, including cleaning for re- fixing or removal to store complete, all as specified and directed by Engineer-in-Charge.
All as per item No 1.66 here-in-before but 20 mm dia.
S&F 15mm bore tubes, 'medium grade' galvanised, with all fitting and fixed complete to walls and ceilings or laid in floors complete, all as specified and directed by Engineer-in-Charge.
S&F 20mm bore tubes, 'medium grade' galvanised, with all fitting and fixed complete to walls and ceilings or laid in floors complete, all as specified and directed by Engineer-in-Charge.
S&F as in repairs, vitreous china wash down water closet pan(pedestal pattern) including connection to drain (or outgoing pipe) and to flushing pipe antisphonage pipe , etc including seat and seat cover for pedestal pan, flush pipe, incl all joints complete, all as specified and directed by Engineer-in-Charge.
S&F as in repairs, vitreous china squatting pan “Orissa” pattern of size 580mmx440mm “white” with integral foot rest (excluding flushing cistern and flush pipe) incl provision of cement concrete bedding, PVC ‘P’ trap 100mm dia connection to trap and flushing pipe, anti-syphonage complete, all as specified and directed by Engineer-in-Charge.
S&F as in repairs, gate valves gun metal with iron wheel head screwed both ends for iron pipe and fixed 20 mm bore fixed complete, all as specified and directed by Engineer-in-Charge.
S&F as in repairs, bib taps long body , cast copper alloy, fancy type with crutch or butterfly handles, chromium plated, screwed down to iron pipes or for brass ferrule of 15 mm bore complete, all as specified and as directed by Engineer-in-Charge.
S&F as in repairs, stop valves, cast copper alloy, fancy type, chromium plated with crutch or butterfly handle, screwed both ends for iron pipe of 15 mm bore complete, all as specified and directed by Engineer-in-Charge.
S&F as in repairs, 15 mm pillar taps swan neck cast copper alloy, with capstan heads, chromium plated screwed down high pressure, with or without lettered "Hot" or Cold with long screwed shanks and fly nuts screwed for iron pipes and fixed, fancy type complete, all as specified and directed by Engineer-in-Charge.
S&F 5mm thick looking mirror with aluminium frame alround and 6 mm thick AC building board at back side with provision of adequate hanging system size 450 mm x 600 mm complete, all as specified and directed by Engineer-in-Charge.
S&F 32mm bore and 75cm long PVC flexible waste pipe for WHB complete, all as specified and directed by Engineer-in-Charge.
S&F as in repairs, vitreous china wash hand basin of size 550 mm x 400 mm white, flat back including angle iron brackets complete, all as specified and directed by Engineer-in-Charge.
S&F as in repairs, 10 Litres capacity PVC flushing cistern white with accessories Flush pipe of polyethylene of low or high density or PVC. 32 mm dia, for low level cistern complete, all as specified and directed by Engineer-in-Charge.
S&F PVC connections 15mm size with PTMT nuts of length 450mm complete, all as specified and directed by Engineer-in-Charge.
M&L for providing precast cement concrete louvers and jallies in repair, 40 mm thick (measured solid) including all mouldings but excluding frame type B-0, 1:2:4 (12.5 mm graded stone aggregate) set in cement mortar 1: 4 complete, all as specified and directed by Engineer-in-Charge.
M&L plain cement concrete type B1, 1:2:4 (using 20 mm graded stone aggregate) as in lintels upto 1.5 m clear span, cills, steps, seismic & other similar bands, plinth courses, string courses, lacing courses, parapets and railings upto 60 cm in height, copings, kneelers, apex stones, bed plates, water troughs and the like including weathering, slightly rounded for chamfered angles and throating, complete, all as specified and directed by Engineer-in-Charge.
S&F as in repairs, rotational moulded polyethylene 3 layer heat resistant water storage tanks white in colour (cylindrical vertical with closed top) hoisted & fixed in position all as specified in SSR Part I 500 Litres capacity complete, all as specified and directed by Engineer-in-Charge.
S&F as in repairs, rotational moulded polyethylene 3 layer heat resistant water storage tanks white in colour (cylindrical vertical with closed top) hoisted & fixed in position all as specified in SSR Part I 1000 Litres capacity complete, all as specified and directed by Engineer-in-Charge.
S&F PTMT valve high pressure with ploythenic float and fly nut complete screwed for iron pipe or brass ferrule 20 mm dia complete, all as specified and directed by Engineer-in-Charge.
M&L for PCC (1:5:10) type E-2 using 40 mm graded brick aggregate as in sunken portion complete, all as specified and directed by Engineer-in-Charge.
M&L for rendering 15 mm thick on concrete/brick surface in cement mortar (1:4) by using WPC finishes surfaces even and fair without using extra cement complete, all as specified and directed by Engineer-in-Charge. Note - WPC will be measured and paid separately.
M&L for polythene film white only 50 micron laid in floor, vertical surface etc complete, all as specified and directed by Engineer-in-Charge.
M&L for applying two coats evenly a tack coat of hot air blown bitumen of grade 85/25 @ 1.50 Kg per sqm per coat (one coat over plaster and one coat on polythene film) including cleaning of surface over polythene film complete, all as specified and directed by Engineer-in-Charge.
Supply only integral water proofing compound complete, all as specified and directed by Engineer-in-Charge.
M&L for preparation of newly plastered or concrete surfaces of ceiling and applying two coats of white wash complete, all as specified and directed by Engineer-in-Charge.
M&L for preparation of newly plastered or concrete surfaces of wall and applying two coats of white wash over a coat of lime wash complete, all as specified and directed by Engineer-in-Charge.
M&L for preparation of newly plastered or concrete surfaces of wall and applying two coat of cement base paint over a coat of lime wash complete, all as specified and directed by Engineer-in-Charge.
M & L for complete removal of existing treatment of surfaces by steel wire brushing, scraping down smoke soots, moulds, moss and efflorescent salts over all decorated plastered or un plastered surfaces of wall surface and applying two coats of cement base paint complete, all as specified and directed by Engineer-in-Charge.
M & L for complete removal of existing treatment of surfaces by steel wire brushing, scraping down smoke soots, moulds, moss and efflorescent salts over all decorated plastered or un plastered surfaces wall and applying two coats of colour washing complete, all as specified and directed by Engineer-in-Charge.
M & L for complete removal of existing treatment of surfaces by steel wire brushing, scraping down smoke soots, moulds, moss and efflorescent salts over all decorated plastered or un plastered surfaces of ceiling and applying two coats of white washing complete, all as specified and directed by Engineer-in-Charge.
M&L for dismantling loose concrete cover of RCC slab, columns, beams, chajjas, balconies, stair case and the like as directed, roughening and cleaning concrete surfaces with steel wire brushes, removing of rust from existing steel surfaces with rust removers of Sika Rustoff 100 applied in two coats @ 0.15 Kg/Sqm per coat of steel surface and cleaning all rust with steel wire brush and washed with water and allowed to dry including S&F welded fabric GI wire mesh or wire, size not less than 75mmx75mm and 3.00 mm dia as reinforcement to concrete. After placing the additional reinforcement, all concrete surfaces shall be thoroughly scrubbed with brushes, washed with water and allowed to dry. To this surface, apply chemical polycrete admixture at the rate not less than 2% by weight of cement and providing minimum 30 mm thick (average thickness) guniting mix (using 1 part of Ordinary Portland Cement, 53 Grade and 2 parts of Ghaggar sand mixed with adhesive/admixture at the rate as directed) with a pressure of 2 to 2.5 Kg per Sqcm by guniting machine and surfaces finished even and fair including necessary padding, shuttering/form work etc and finally applying 5 mm thick cement plaster in CM 1:3 complete all as specified and directed. . Note: (i) Where ever steel reinforcement required rate of the same deemed to be included in the quoted rate. (ii) Work to be executed for upto two storey buildings and in Patch work.
Demolition of cement concrete or lime concrete (unreinforced) of any description and in any position not otherwise specifically provided for and removing the debris out side defence land from the site complete, all as specified and directed by Engineer-in-Charge.
M&L 75mm thick PCC type C1,1:3:6 (20mm graded stone aggregate) as in floor/path/plinth protection including necessary form work, surfaces finished even and smooth without using extra cement complete, all as specified and directed by Engineer-in-Charge.
M& L for 80 mm thick, M-40 grade machine pressed rubber form moulded precast interlocking concrete paver block over 30mm thick sand cushioning in any shape and size as approved confirming to IS 15658-2006 complete, all as specified and directed by Engineer-in-Charge.
M&L for chequered cement concrete tiles 20cm x20cm x 25mm thick, set, jointed and pointed in neat cement slurry in floors etc, set, jointed & pointed with cement slurry 15mm thick bedding layer of cement sand mortar (1:6) complete, all as specified and directed by Engineer-in-Charge.
M&L for 75mm thick cement concrete type D-2, 1:4:8 (using 40 mm graded stone aggregate) as in sub base for floors finishes complete, all as specified and directed by Engineer-in-Charge.
M&L for 40mm thick cement concrete type B1, 1:2:4 (using 20 mm graded stone aggregate) as in floors Finishing cement concrete surface even and smooth without using extra cement complete, all as specified and directed by Engineer-in-Charge.
S&F Harrison rails, mild steel, chromium plated with fixing brackets, stops, rollers etc complete, all as specified and directed by Engineer-in-Charge.
BOQ PART-II (E/M WORKS)
M& L for fabricate, supply and install cubicle type, CPRI approved LT panel board,outdoor type, insulating copper bus bar 600 Amps 3 Nos totally enclosed,dust & vermin proof (protection class IP 65) front opening with self locking arrangment made out of MS angle iron frame work 50x50x 6mm, MS flat iron and CRCA sheet of 3.15 mm thick as per IS 5039 duly painted with powder coated paint of approved shade. The panel shall be suitable for 415 volts,50 Hz, 3 phase 4 wire system and shall be complete with 600 Amp capacity copper bus bar, colour coding to the bus bars as per relevant IS specifications with Fire retardant PVC insulating materials, wiring the panel board with suitable size of PVC insulated, multi stranded copper cables and all connected accessories required for functioning of panel board such as thimbles,glands, bolts, nuts,washers etc including necessary earth work for foundation work and foundation PCC with grouting bolts and nuts complete including supply and fixing following accessories:- (a) MCCB FP 200 Amps, 36 KA,415V, 50Hz- 02 Nos. (b) MCCB FP 160 Amps, 36 KA,415V, 50Hz- 01 Nos. (c) Indicator lamp neon/LED type (set of three). (d) Voltmater and ammeter digital type including suitable capacity of CTs. Note : Contractor shall submit design of the sheet metal enclosure alongwith accessories for approval before fabrication.
Taking down the defective LT panels, outdoor type, with connected accessories after disconnecting the electric supply and keeping the safe custody for giving credit to the contractor complete, all as specified and directed by Engineer-in-Charge.
Taking down carefully copper/aluminium point wiring light, fan, socket or power) complete, fitting such as switches, ceiling roses, pendents, regulators, sockets etc removing materials to store for keeping in safe custudy or for taking credit (credit for above items should be made as per conditioned separately) and making good disturbed surface of walls, floors etc complete, all as specified and directed by Engineer-in-Charge.
M&L for point wiring for following types of electrical points with two runs of S/C FRLS PVC insulated but unsheathed IS-694 marked 1100 Volt grade cable multi stranded copper conductor of size 1.5 Sqmm drawn through casing capping heavy duty ISI marked not less than 20mm dia alongwith conduit fittings and accessories connected in wall/ or surface/ceiling including provision of pressed steel terminal boxes of 2 mm thick cover with plastic laminated sheet cover for mounting switches, sockets and regulator alongwith continous earth wire of PVC insulated, unsheathed, 1100 V, FLRS IS-694 marked grade cable multi stranded copper conductor of size 1.5 Sqmm for light/fan point and 5 Amps outlet independent socket point complete, all as specified and directed by Engineer-in-Charge. Note : Cost of cutting chasing and making good to disturbed surface to match with existing surface are deemed to be included in quoted rate.
S&F switch piano 5 Amps flush type single pole one way suitable for 240 volt AC complete, all as specified and directed by Engineer-in-Charge.
S&F socket outlet flush type 5 pin 6 Amps suitable for 240 volt AC complete, all as specified and directed by Engineer-in-Charge.
Taking down submain wiring of any size of cable connected to common earth dolly including batten/conduit complete, all as specified and directed by Engineer-in-Charge.
M& L for submain wiring with 3 runs of 4.0 sq mm single core copper conductor, PVC insulated but unsheathed FRLS cable of specified size of multi stranded copper conductor, 1100 volts grade IS:694 marked drawn through in and including casing capping heavy duty, ISI marked (not less than 20 mm dia) complete with all fittings and accessories laid/fixed in wall or surface/ceiling and also include specified runs of specified earth continuity conductor of similar type cable complete, all as specified and directed by Engineer-in-Charge. Note :- 3 runs of cable and one run of casing capping will be measured as an one unit.
Taking down tube light fittings/ceiling fittings/holder fittings of any type and make and removing materials to store for kepping in safe custody or for reuse or taking credit and making good disturbed surface of walls, floors etc complete, all as specified and directed by Engineer-in-Charge.
S&F in replacement of wall mounted LED batten extruded aluminium heat shrink provided for efficient heat dissipation and integrated electronic driver 20 watt LED fitting, 5700K-6500K, 230 Volts, etc complete with all accessories, connecting up with twin core twisted flexible copper conductor cable from ceiling rose to fitting, fixed on two PVC round blocks and testing complete, all as specified and directed by Engineer-in-Charge. Make : Havells Cat Part No LUMILINEPLUSBS20WLED865SPCSS or Wipro Cat Part No LL20221XXX65AL1 or its equivalent in Philips
S&F in replacement of wall mounted LED batten extruded aluminium heat shrink provided for efficient heat dissipation and integrated electronic driver 10 watt LED fitting, 5700K-6500K, 230 Volts, etc complete with all accessories, connecting up with twin core twisted flexible copper conductor cable from ceiling rose to fitting, fixed on two PVC round blocks and testing complete, all as specified and directed by Engineer-in-Charge. Make : Havells Cat Part No LUMILINEPLUSBS10WLED865SPCSS or Wipro Cat Part No LL20111XXX65NE3 or its equivalent in Philips.
S&F in replacement of wall mounted LED bulk head fittings, 10 watt, 5700K-6500K, 230 Volts, diffused optics etc complete with all accessories, connecting up with twin core twiested flexible copper conductor cable from ceiling rose to fitting and testing complete, all as specified and directed by Engineer-in-Charge. Make : Havells Cat Part No RUGBYNEONFT10WLED860SSYMTOPC or Wipro Cat Part No LW07141XXX57XX or its equivalent in Philips.
S&F in replacement of CFL with LED bulb 7 watt complete, all as specified and directed by Engineer-in-Charge. Make : Havells or equivalent in Philips/Wipro.
S&F in replacement of lamp holder, PVC/polycarbonate type with cord grip cap suitable for LED bulb 5/7/9 watt complete, all as specified and directed by Engineer-in-Charge.
J D ENTERPRISES
M/s. Kansal Construction Co.
Vishal Enterprises
A.S. ENGINEERS AND CONTRACTORS
Amson electronics
Ashish Sehgal and Co.
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .