| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹51.9 LAccepted-AOC PLOT NO 46 WARD NO 08 OPPOSITE RADIO TOWER SAGAR ROAD TILAK NAGAR BIKANER 334003 RAJ | BIKANER | BIKANER | RAJASTHAN | 334003 | L1 | Accepted-AOC L1 Bidder | |
| 2 | L2₹54.3 L+₹2.4 L (4.61%)Rejected-Finance | L2 | Rejected-Finance Not the Lowest Bidder | |
| 3 | L3₹62.0 L+₹10.0 L (19.3%)Rejected-Finance C O GENERAL DAIRY VILLAGE BARAGAON SRI GANGANAGAR 335 001 | GANGANAGAR | RAJASTHAN | 335001 | L3 | Rejected-Finance Not the Lowest Bidder | |
| 4 | L4₹67.1 L+₹15.2 L (29.2%)Rejected-Finance RM 01 RIDHISIDHI I SRI GANGANAGAR 335001 RAJ | SRI GANGANAGAR | SRI GANGANAGAR | RAJASTHAN | 335001 | L4 | Rejected-Finance Not the Lowest Bidder | |
| 5 | L5₹67.3 L+₹15.4 L (29.6%)Rejected-Finance 51 HANUMAN COLONY GALI NO 4 CHAK 5 E CHHOTI SRI GANGANAGAR RAJ | L5 | Rejected-Finance Not the Lowest Bidder |
| Sl No | Description | Qty | Unit | KHANNA CONSTRUCTIONS L4 | M/s Singla Trading Comapny L7 | M/S BUDHRAM BISHNOI L1 | PAREEK AND COMPANY L3 | SHIVA CONSTRUCTION COMPANY L5 | J and P CONTRACTOR L6 | AYUSH BUILDERS L2 | Akarsha Enterprises L8 |
|---|---|---|---|---|---|---|---|---|---|---|---|
| 1.00 | M&L for reinforced cement concrete type B1 1:2:4 (20 mm graded aggregate) as in slab supported on walls, beam and column in floors, roofs,landings,balconies,deck slab, parapet walls and in shelves and etc and setting in mortar complete with joints to match complete all as specified and directed by Engr-in-Charge.
Note : Rates of Demolition of RCC of any descrition are included in quoted rate. | 10 | Cum | 6,000 ₹60,000 | 5,500 ₹55,000 | 529 ₹5,290 Lowest | 5,000 ₹50,000 | 8,000 ₹80,000 | 5,500 ₹55,000 | 7,500 ₹75,000 | 6,200 ₹62,000 |
| 2.00 | M & L for formwork to sides and soffits of floor or roof beams, beam haunch ings, girders, bressummers, lintels, cantilevers, shelves including sup- ports, overhangs, etc. also splays between floors and beams, in flat surfaces etc. complete all as specified and directed by Engr-in-Charge. | 83 | Sqm | 150 ₹12,450 Lowest | 450 ₹37,350 | 359 ₹29,797 | 160 ₹13,280 | 600 ₹49,800 | 150 ₹12,450 Lowest | 250 ₹20,750 | 300 ₹24,900 |
| 3.00 | M & L mild steel TMT bars 10 mm dia and over, cut to length, bent to shape required, including cranking, bending, hooking ends and binding with mild steel wire (annealed) not less than 0.90mm dia complete all as specified and directed by Engr-in-Charge. | 838 | Kg | 85 ₹71,230 | 85 ₹71,230 | 89 ₹74,582 | 80 ₹67,040 | 95 ₹79,610 | 75 ₹62,850 Lowest | 85 ₹71,230 | 90 ₹75,420 |
| 4.00 | M&L brick work with sub class B bricks straight or curved on plan exceeding 6 mtr mean radius in cm 1:6 etc including demolition of brick work or stone/boulder masonry built in cement mortar including all quoins, arches , pillars etc but excluding ashlar facings, dressed stone work and precast concrete articles complete all as specified and directed by Engr-in-Charge. | 29 | Cum | 4,200 ₹1,21,800 | 3,650 ₹1,05,850 | 3,529 ₹1,02,341 | 4,000 ₹1,16,000 | 4,800 ₹1,39,200 | 2,800 ₹81,200 Lowest | 4,000 ₹1,16,000 | 5,000 ₹1,45,000 |
| 5.00 | Dismantling brick tiles or terracing tiles, single layer on roofs and mud phuska complete all as specified and directed by Engr-in-Charge. | 2,220 | Sqm | 80 ₹1,77,600 | 18 ₹39,960 Lowest | 99 ₹2,19,780 | 60 ₹1,33,200 | 100 ₹2,22,000 | 30 ₹66,600 | 100 ₹2,22,000 | 30 ₹66,600 |
| 6.00 | OVERLAY- PU BASED ELASTOMERIC LIQUIED MEMBRANE SYSTEM FOR EXPOSED ROOF : Providing and applying polyurethane liquid roof waterproofing with improved water ponding capability, thermal insulating elastomeric high build liquid membrane for concrete roofs for exterior wall and exposed surface with solid content not less than 80% and solar reflective index 109 as per (ASTM E1980-19)/tear strength ~20 N/mm (Free film, 14 days, +30 degree C) (ASTM D624) and tensile strength >= 2 N/mm2 (ASTM D4541).
(a) After proper surface preparation, Apply one coat of Primer for PU coating as per manufacturers specification.
(b) Apply 1st coat of ShaliUrethane® BTD (white) @ 650 gm / m²(minimum) or equivalent by brush / roller while prime surface is tacky, Spread waterproofing reinforced Glass Fiber mash of 45 GSM with overlaps of 50 mm in both directions when the surface is still tacky. Allow 1st coat to dry.
(c ) Apply 2nd & 3rd coat of ShaliUrethane® BTD (white) @ 650 gm / m² (minimum) or equivalent by brush/roller.
Make : Fosroc/Sika/Choksey/Bostik/STP/Asian Paints
Note : (i) The Minimum dry film thickness (DFT) of roof treatment shall be 1.5mm if any shortfall in thickness of above treatment the same shall be achieved by additional coat.
(ii) The procurement of material and execution of the work of water proofing treatment shall be carried out by authorised applicator approved by GE.
(iii) The manufacturer/authorised applicator shall give a warranty for the performance & durability for 10 years. | 4,770 | Sqm | 900 ₹42,93,000 | 925 ₹44,12,250 | 599 ₹28,57,230 Lowest | 830 ₹39,59,100 | 780 ₹37,20,600 | 1,100 ₹52,47,000 | 625 ₹29,81,250 | 1,020 ₹48,65,400 |
| 7.00 | M&L for levelling course for roof slab, Type B0, 1:2:4 (12.5 mm graded aggregate) using waterproofing compound (SBR) for maintaining proper roof slope and finishing cement concrete surface even and smooth without using extra cement complete all as specified.(Minimum thickness of concrete should not be less than 50mm at any point)
Note : Waterproofing compound should be measured and paid separately. | 247.5 | Cum | 4,500 ₹11,13,750 | 5,200 ₹12,87,000 | 3,229 ₹7,99,177.5 | 4,000 ₹9,90,000 | 5,400 ₹13,36,500 | 2,500 ₹6,18,750 Lowest | 4,000 ₹9,90,000 | 6,000 ₹14,85,000 |
| 8.00 | M&L 10 mm thick cement plaster in cement mortar 1:3 on ceiling/roof top surfaces finished even and smooth without using extra cement complete all as specified and directed by Engr-in-Charge. | 500 | Sqm | 220 ₹1,10,000 | 160 ₹80,000 | 169 ₹84,500 | 120 ₹60,000 Lowest | 200 ₹1,00,000 | 180 ₹90,000 | 150 ₹75,000 | 240 ₹1,20,000 |
| 9.00 | M&L 5 mm thick cement plaster in cement mortar 1:3 on ceiling/roof top surfaces finished even and smooth without using extra cement including taking down plaster on lathing (other than wire-netting) without removing lathing in cement mortar complete all as specified and directed by Engr-in-Charge. | 300 | Sqm | 120 ₹36,000 Lowest | 140 ₹42,000 | 169 ₹50,700 | 120 ₹36,000 Lowest | 180 ₹54,000 | 190 ₹57,000 | 125 ₹37,500 | 230 ₹69,000 |
| 10.00 | Taking down plastering on lathing (other than wire-netting) without removing lathing in cement mortar complete all as specified and directed by Engr-in-Charge. | 296 | Sqm | 10 ₹2,960 Lowest | 20 ₹5,920 | 29 ₹8,584 | 80 ₹23,680 | 30 ₹8,880 | 20 ₹5,920 | 35 ₹10,360 | 10 ₹2,960 Lowest |
Tender Value
Refer Docs
EMD Value
₹1.6 L
Closing Date
23 Aug 2025, 6:00 pmClosed
HQ CWE SRI GANGANAGAR
HQ CWE POST BOX 48 SRI GANGANAGAR-335001 (Rajasthan)
REPAIR / REPLACEMENT OF ROOF TREATMENT AND ROOFING OF CERTAIN OTM ACCN OF ZONE C AND D UNDER GE SGNR AT SRI GANGANAGAR MIL STN
2025_MES_719754_1
CA NO CWE SGNR/TOKEN-23 OF 2025-26
Open Tender
Civil Works
Item Rate
180 days
GE SRI GANGANAGAR
As per NIT
8 documents required · 8 mandatory
₹1,000
GE SRI GANGANAGAR
₹1.6 L
Yes
18 Sept 2025
10 Jul 2025
25 Aug 2025
10 Jul 2025
23 Aug 2025
9 Aug 2025
Amount
M&L for reinforced cement concrete type B1 1:2:4 (20 mm graded aggregate) as in slab supported on walls, beam and column in floors, roofs,landings,balconies,deck slab, parapet walls and in shelves and etc and setting in mortar complete with joints to match complete all as specified and directed by Engr-in-Charge. Note : Rates of Demolition of RCC of any descrition are included in quoted rate.
M & L for formwork to sides and soffits of floor or roof beams, beam haunch ings, girders, bressummers, lintels, cantilevers, shelves including sup- ports, overhangs, etc. also splays between floors and beams, in flat surfaces etc. complete all as specified and directed by Engr-in-Charge.
M & L mild steel TMT bars 10 mm dia and over, cut to length, bent to shape required, including cranking, bending, hooking ends and binding with mild steel wire (annealed) not less than 0.90mm dia complete all as specified and directed by Engr-in-Charge.
M&L brick work with sub class B bricks straight or curved on plan exceeding 6 mtr mean radius in cm 1:6 etc including demolition of brick work or stone/boulder masonry built in cement mortar including all quoins, arches , pillars etc but excluding ashlar facings, dressed stone work and precast concrete articles complete all as specified and directed by Engr-in-Charge.
Dismantling brick tiles or terracing tiles, single layer on roofs and mud phuska complete all as specified and directed by Engr-in-Charge.
OVERLAY- PU BASED ELASTOMERIC LIQUIED MEMBRANE SYSTEM FOR EXPOSED ROOF : Providing and applying polyurethane liquid roof waterproofing with improved water ponding capability, thermal insulating elastomeric high build liquid membrane for concrete roofs for exterior wall and exposed surface with solid content not less than 80% and solar reflective index 109 as per (ASTM E1980-19)/tear strength ~20 N/mm (Free film, 14 days, +30 degree C) (ASTM D624) and tensile strength >= 2 N/mm2 (ASTM D4541). (a) After proper surface preparation, Apply one coat of Primer for PU coating as per manufacturers specification. (b) Apply 1st coat of ShaliUrethane® BTD (white) @ 650 gm / m²(minimum) or equivalent by brush / roller while prime surface is tacky, Spread waterproofing reinforced Glass Fiber mash of 45 GSM with overlaps of 50 mm in both directions when the surface is still tacky. Allow 1st coat to dry. (c ) Apply 2nd & 3rd coat of ShaliUrethane® BTD (white) @ 650 gm / m² (minimum) or equivalent by brush/roller. Make : Fosroc/Sika/Choksey/Bostik/STP/Asian Paints Note : (i) The Minimum dry film thickness (DFT) of roof treatment shall be 1.5mm if any shortfall in thickness of above treatment the same shall be achieved by additional coat. (ii) The procurement of material and execution of the work of water proofing treatment shall be carried out by authorised applicator approved by GE. (iii) The manufacturer/authorised applicator shall give a warranty for the performance & durability for 10 years.
M&L for levelling course for roof slab, Type B0, 1:2:4 (12.5 mm graded aggregate) using waterproofing compound (SBR) for maintaining proper roof slope and finishing cement concrete surface even and smooth without using extra cement complete all as specified.(Minimum thickness of concrete should not be less than 50mm at any point) Note : Waterproofing compound should be measured and paid separately.
M&L 10 mm thick cement plaster in cement mortar 1:3 on ceiling/roof top surfaces finished even and smooth without using extra cement complete all as specified and directed by Engr-in-Charge.
M&L 5 mm thick cement plaster in cement mortar 1:3 on ceiling/roof top surfaces finished even and smooth without using extra cement including taking down plaster on lathing (other than wire-netting) without removing lathing in cement mortar complete all as specified and directed by Engr-in-Charge.
Taking down plastering on lathing (other than wire-netting) without removing lathing in cement mortar complete all as specified and directed by Engr-in-Charge.
M&L for cement plastering 15mm thick in two layers (10mm and 5mm respectively) in cemet mortar 1:4 including mixing of liquid water proofing compound as per manufacturer's instructions on brick work or concrete surfaces or in chajjas/parapet walls etc finished even and smooth without using extra cement and fixing of chicken wire gauge where directed complete all as specified and as directed by Engineer-in-Charge. Note : WPC will be measured and paid separately.
Supply of SBR waterproofing compound @ 2% of per kg cement used complete all as specified. Make : Fosroc/Sika/Choksey/Chemsol/Bostik/STP
M & L for three coats of white washing on new plastered surfaces of on ceiling surface including preparation of surface complete all as specified and directed by Engr-in-Charge.
M & L Preparation of new plastered surfaces of wall and applying two coats of cement base paint over 1 mm thick wall putty complete all as specified and directed by Engr-in-Charge.
Taking up or down GI steel water tubing 15mm bore and connections including fittings from floor/walls/ceiling complete all as specified and directed by Engr-in-Charge.
Taking up or down GI Steel water tubing 20mm bore and connections including fittings from floor/walls/centrings complete all as specified and directed by Engr-in-Charge.
Taking up or down GI Steel water tubing 25mm bore and connections including fittings from floor/walls/centrings complete all as specified and directed by Engr-in-Charge.
S & F Galvanised steel water tubing 15 mm bore medium grade with all fittings concealed including cutting chases to brick wall/ceiling or laying in floors and making good complete all as specified and directed by Engr-in-Charge.
S & F Galvanised steel water tubing 20 mm bore medium grade with all fittings concealed including cutting chases to brick wall/ceiling or laying in floors and making good complete all as specified and directed by Engr-in-Charge.
S & F Galvanised steel water tubing 25 mm bore medium grade with all fittings concealed including cutting chases to brick wall/ceiling or laying in floors and making good complete all as specified and directed by Engr-in-Charge.
Disconnecting existing tanks of capacity 500 litres to 1000 litres, setting aside (or lowering if required) for repairs, cleaning, etc. and hoisting if required reconnecting and re-fixing in position. Cleaning and removing all scale and dirt, etc, from tanks and from mouths of circulating pipes, etc. complete all as specified and directed by Engineer in Charge
Dismantling water tanks exc. 250 ltr but not exc 500 ltr complete all as specified and directed by Engr-in-Charge.
Dismantling water tanks exc. 500 ltr but not exc 1000 ltr complete all as specified and directed by Engr-in-Charge.
Hoisting only water tanks 1000 Ltr capacity (Tank supplied by department) including all necessary fittings (making holes for inlet / outlet, tank nipple, 20mm ball valve etc and removing tank from store and transport to site complete all as specified and directed by Engr-in-Charge.
Hoisting only water tanks 500 Ltr capacity (Tank supplied by department) including all necessary fittings (making holes for inlet / outlet, tank nipple, 20mm ball valve etc and removing tank from store and transport to site complete all as specified and directed by Engr-in-Charge.
S&F 25 mm ball valve high pressure of PTMT with apoxy coated aluminium rod and high density plastic ball screwed for iron pipe, complete all as specified and directed by Engr-in-Charge.
Fixing only 25 mm ball valve high pressure of PTMT with apoxy coated aluminium rod and high density plastic ball screwed for iron pipe, complete all as specified and directed by Engr-in-Charge.
S&F Bands, straps, supports or stays for rainwater, ventilating pipes, including bolts, if required: hooks (stay), heavy, for large gates; hook and pintle hinges: large hasps and staples; chains; hand made sliding bolts; clamps; hold fasts; wall ties; hooks for hanging fans; plain angle cleats for securing purlins to wood trusses or rafters; knee piece inserts; two way and three way straps, plate washers and similar small articles, tank conforming to Fe-290 Gde-E-165 complete all as specified and directed by Engr-in-Charge.
M&L two coat of synthetic enamel paint on old painted surfaces of steel and iron work over 10 cm width or girth including preparation complete all as specified and directed by Engr-in-Charge.
M&L, two coats of synthetic enamel paint over a coat of red oxide on steel surface over 10 cm width or girth, not otherwise described including preparation of new surface complete all as specified and directed by Engr-in-Charge.
S&F 110mm bore PVC (SWR) pipes single socketed in any length with rubber ring joints fixed to wall with PVC holding clamps/laid int trenches and includging Demolition and breaking up or taking down PVC/AC/CI/SSW 100mm bore pipe drain pipes, set in cement mortar including PCC haunching and bedding, complete all as specified and directed by Engr-in-Charge.
S&F 110mm bore PVC (SWR) bend/Tee, any radius with access door complete all as specified and directed by Engr-in-Charge.
S&F 110mm bore PVC (SWR) vent cowl complete all as specified and directed by Engr-in-Charge.
S&F 110mm bore PVC 'S/P' Trap complete all as specified and directed by Engr-in-Charge.
S & F Stack clamps out of 50mm by 5 mm flat iron and 16mm dia round iron stays for 100mm bore of pipe, including bolts and nuts and securing ends of stays to wall or roof etc complete all as specified and directed by Engineer - in - Charge.
S&F in repair 20 mm Gun-metal, globe or gate valves, with iron wheel head, screwed both ends for iron pipe and fixed complete all as specified and directed by Engr-in-Charge.
Fixing only 20 mm Gun-metal, globe or gate valves, with iron wheel head, screwed both ends for iron pipe and fixed complete all as specified and directed by Engr-in-Charge.
Disconnecting existing tanks of capacity exceedin 250 litres & not exceeding 500 litres etc, setting aside (or lowering if required) for repairs, cleaning, etc. and hoisting if required reconnecting and re-fixing in position. Cleaning and removing all scale and dirt, etc, from tanks and from mouths of circulating pipes, etc. complete all as specified and directed by Engineer in Charge.
AYUSH BUILDERS (BID ID -3403870)
PAREEK AND COMPANY (BID ID -3394949)
KHANNA CONSTRUCTIONS (BID ID -3394438)
SHIVA CONSTRUCTION COMPANY (BID ID -3396347)
J and P CONTRACTOR (BID ID -3403869)
M/s Singla Trading Comapny (BID ID -3394729)
Akarsha Enterprises (BID ID -3389276)
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .