GE BHOPAL BAIRAGARH BHOPAL
REPAIRS TO FENCING DRAIN FOOTPATH STEPS AND SEWAGE LINES AT SI LINES UNDER GE BHOPAL
2021_MES_434874_1
8764/E8
Open Tender
Civil Works
Item Rate
180 days
BHOPAL
AS PER TENDER DOCUMENTS
6 documents required · 6 mandatory
₹500
Yes
GE BHOPAL
₹50,000
Yes
18 Jun 2021
7 Apr 2021
21 May 2021
7 Apr 2021
19 May 2021
26 Apr 2021
Amount
Demolition of brickwork built in cement or cement lime mortar complete all as specified and directed.
Demolition of reinforced concrete in ground floors and pavings nexc 15 cm thickness (below or above ground level) of shelves, platforms, jaffri and similar work etc complete all as specified and directed.
Demolition of concrete in ground floors and pavings exc 15 cm thickness (below or above ground level) complete all as specified and directed.
Demolition and breaking up drain pipe of 100/150mm internal (SGSW) pipe/PVC/RCC set in cement mortar and disposal of unservicable material and rubbish to a distance not exc 100m complete all as specified and directed.
All as per Item No 4.00 above above but 200mm dia pipe
All as per Item No 4.00 above but 300mm dia pipe
Taking down cement plaster on brick or stone walls/ceiling etc including racking out joints, hacking for key, scrubbing down with water etc complete all as specified and directed.
Dismantling posts or struts (Wood, steel or RCC) any section, including taking out embedded portion and making good disturbed ground (posts embedded in concrete, brick work, masonry work, etc.) complete all as specified and directed.
M&L for PCC 1:4:8 type D2 (using 40 mm graded stone aggregate) as in sub base, foundation filling and mass concrete etc. complete all as specified and directed.
M&L for cement concrete type B1, 1:2:4 (using 20 mm graded stone aggregate) as in as surface channel, etc for drain and similar works complete all as specified and directed.
M&L for cement concrete type B1, 1:2:4 (using 20 mm graded stone aggregate) as in benching, coping etc for drain and similar works complete all as specified and directed.
M&L for PCC 1:3:6, Type C2 (using 40 mm graded stone aggregate) in foundation, filling and mass concrete as in boundary pillars and post etc complete all as specified and directed.
M&L for 25mm thick PCC type B-0, 1:2:4 (using 12.5 mm graded stone aggregate) as in sub base of floor complete all as specified and directed.
Extra for forming fair finished drain or channel 30cm inner girth in cement concrete, using extra cement, including forms, moulds, initered/stopped ends complete all as specified and directed.
Add or deduct from item No. 14.00 above for each 25mm girth or part thereof over or under 30cm for forming fair finished drain complete all as specified and directed.
M&L for Brick work with fly ash bricks (modular brick) straight or curved on plan exc 6 m mean radius built in cm 1:6 complete all as specified and directed.
M&L for stone walling of random rubble, brought upto courses, well bonded, bedded and solidly hearted, built in CM (1:6) complete all as specified and directed.
M&L for 15 mm thick rendering on fair faces of brick works or concrete surfaces in cm 1:4 finishing even and smooth without extra cement complete all as specified and directed.
Supply only integral water proofing compound complete all as specified and directed. [MAKE: ACCOPROOF/WATER SEAL/MC BOUCHAMIE, MUMBAI/FOSROC/CICO/PIDILITE]
M&L for Factory made, machine pressed, M-35 grade concrete interlocking paver blocks (glossy /reflective type), with grey cement and pigment, any shape and size conforming to IS:15658-2006 (ISI Marked) of 60 mm thickness with & including 50 mm thick stone dust cushion and joints filled with sand complete all as specified and directed. [MAKE:- MEHTAB / NAVYA TILES / SAP PAVERS/ SAGAR TILES]
M&L for Factory made, machine pressed, M-40 grade concrete interlocking paver blocks (glossy/reflective type), with grey cement and pigment, any shape and size conforming to IS:15658-2006 (ISI Marked) of 80 mm thickness with & including 50 mm thick stone dust cushion and joints filled with sand complete all as specified and directed. [MAKE:- MEHTAB / NAVYA TILES / SAP PAVERS/ SAGAR TILES]
Taking down old paver blocks any shape, size and thickness from the existing surface and refixing at the same place after levelling the ground by using sand for maintaing camber and slope complete all as specified and directed.
M&L for heavy duty flooring tiles, harsh weather & UV Resistance, high abrasion resistance, MOH Hardness >6, thickness 10 mm thick, area of each tile not less than 0.09 sqm, anti slip type, laid in floors, steps, edges, etc set and jointed in neat cement slurry and pointed in white or coloured cement to match tile with & including 15mm thick rendering in CM 1:4 complete all as specified and directed. [MAKE: SOMANY/ KAJARIA/ORIENT/JOHNSON]
M&L for Chequered paver tiles reflective/glossy type, any colour as decided by GE, size- 300mm x 300mm x 20 to 25mm thick, set, jointed and pointed in neat cement slurry in floors, etc with & including 20mm thick screed bed in CM 1:4 complete all as specified and directed.
Use & waste of Form work to soffits of suspended slabs such as roof slabs, floor slabs, landings and similar work; not exceeding 200mm thick, for fair finished flat surfaces of concrete complete all as specified and directed.
S&F Mild steel TMT bars 10mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified and directed.
All as per item No 26.00 here in before but 6mm to 8mm
M&L for Reinforced cement concrete design mix M-25 grade as in slabs supported on walls, beams & columns complete all as specified and directed.
S&F Rolled mild steel conforming to Fe-290 (Gde E-165) as in posts & struts in fencing including cutting tops to shape as directed, drilling holes, notching for wire, etc, flat iron fillets( for securing wire mesh etc.) including all necessary drilling, bolting or riviting, etc., and similar work complete all as specified and directed.
S&F mild steel screw bolts (machine made) with hexagonal or square heads at one end and screwed the other, or screwed both ends, each screwed end to be fitted with washers and one hexagonal or square nut, n. exc 5 cm long. (Diameter of neck in 11 to 15 mm) complete all as specified and directed.
Supply only chain link MS galvanised fencing, any size or type complete all as specified and directed.
Fixing only chain link MS galvanised fencing, any size or type including dismantling old rusted/broken fencing complete all as specified and directed.
S&F in repair Galvanised 2 strand, steel barbed wire 2.24mm dia barbed with 2mm dia barbs at 75mm spacings and straining and fixing to any type of standard rails straining bolts, including, securing or tying at crossings with and provision of galvanised mild steel wire, staples or steel pins, etc. as directed (each line wire to be measured) including dismantling old rusted/broken wires complete all as specified and directed.
Excavating in post holes (or similar holes) in hard or dence soil each n exc 0.5 cum, getting out, returning, filling in and ramming earth or broken rubble mixed with earth around, in layers not exceeding 25cm, watering, and removing surplus soil to a distance n exc 50 m and making good surface complete all as specified and directed.
S&F mild steel work as in holdfast conforming to Fe-290-Gde-E-165 complete all as specified and directed.
S&F Framed work such as grills, gratings, steel gate, purlin etc., with ends of bars shouldered and/or riv-eted, or forged into spikes; framed guard bars; barred iron doors; ladders; framed balusters; walk ways; railings; framework of water tanks and similar work conforming to Fe 290 gde E-165 complete all as specified and directed.
Preparation of old decorated surfaces of wall including brooming, scraping down moulds, moss, efflorescent salts, trading oil, greasy spots and stopping nails marks and applying one coat of cement based paint, white or tinted complete all as specified and directed.
M&L for preparation of newly plastered surfaces and applying two coats of cement base paint on wall surfaces complete all as specified and directed.
M&L for Preparation new steel surface of any description and applying two coats of synthetic enamel paint over one coat of red oxide, zinc Chrome primer complete all as specified and directed.
M&L for Cutting holes in brick walls exc half brick but not exc one brick wall built in CM for inserting hold fast and making good dismantled portion in CM 1:3 or cement concrete 1:2:4 type B-1 as required complete all as specified and directed.
S&F Steel work in tubular/structural trusses, purlins, etc including special shaped washer etc complete using ERW or induction butt welded tubes conforming to IS.1161-1979 grade St.-240 or steel sections conforming to Fe 410-W (Gde E-250) quality -A complete all as specified and directed.
M&L for Mild 1.60 mm steel, plain black sheet in wall cladding, steel gates and similar work, cut to size, holes punched; including round headed screws, clout nails or rivets and fixed to wood or steel framing with plain 40mm lap joints with riveted or welded seams, including bending or turning up, mitred angles, etc. as required complete all as specified and directed.
M&L for 150 mm Reinforced concrete pipes, class NP2, laid and jointed complete with collars complete all as specified and directed.
M&L for 200 mm Reinforced concrete pipes, class NP2, laid and jointed complete with collars complete all as specified and directed.
M&L for 300 mm dia Reinforced concrete pipes, class NP2, laid and jointed complete with collars complete all as specified and directed.
M&L for Providing precast reinforced cement concrete 1:2:4 type B-0 using 12.5mm graded stone aggregate in louvers and jallies 35mm thick (measured solid) including all mouldings but excluding frame and set in cement mortar 1:4 complete all as specified and directed.
M&L for Providing reinforced cement concrete type B-1, 1:2:4 (20 mm graded aggregate) In precast posts, fencing posts, straining or terminal posts, struts etc. for fencing, average sectional area in exc 100 sq. cm, with or without chamfered angles and flat, splayed, rounded or mitred tops complete all as specified and directed.
M&L for providing precast cement concrete kerb stones/apex stones etc in PCC 1:2:4 type B1 (using 20 mm graded stone aggregate and set in cement mortar 1:4 complete all as specified and directed.
Excavation in trenches, not exceeding 1.5m wide and not exceeding 1.5m in depth for foundation, etc or not exceeding 10 Sqm on plan and not exceeding 1.5m in depth for shafts, cesspits, manholes, pier holes, etc and getting out in soft/loose soil complete all as specified and directed.
Returning, filling in, including spreading, levelling, watering and well ramming in layers not exceeding 25cm thick each layer as in soil complete all as specified and as directed.
Removing excavated soil not exceeding 50m and depositing where directed at a level not exceeding 1.5m above the starting point complete all as specified and directed.
Cleaning of existing sewage line of any dia by rodding, flushing etc and tanking out through existing manhole any sewage pit and burried in suitable pit dug out for the purpose covered with excavated soil including new pit complete all as specified and directed.
Cleaning of manhole with full of sludge any depth by manually or any other method and taking out sludge / grit and deposited in new pit dug out for the purpose covered with excaveted soil incl M&L for pit complete all as specified and directed.
Cleaning of septic tank/ soakage well sludge chamber ( inlet & outlet) etc of any depth including cleaning of sludge/grit from last MH to septic tank by manually or any other method, Taking out sludge / grit complete including removing /depositing all spoils/sludge in new pit dug out for the purpose covered with excavated soil complete all as specified and directed.
Cleaning of sewage line from WC/Gully trap to Ist MH/cleaning of WC in Ist floor to Ist MH including removal of sludge by rodding or by another method all as specified and directed.
Cleaning of bathroom floor trap to Ist MH/cleaning of bathroom floor trap in Ist floor to Ist MH including removal of sludge by rodding or by other means complete all as specified and directed.
Taking out water/Sludge/Waste from septic tank , soak well sludge chamber manually or by pumping taking out sludge / grit complete including removing /depositing all spoils/sludge in new pit dug out for the purpose covered with excavated soil all complete all as specified and directed.
S&F 75 mm bore PVC (SWR) pipes double socketed in any length with rubber rings joints fixed to walls including clamps complete all as specified and directed.
S&F 110 mm bore PVC (SWR) pipes double socketed in any length with rubber rings joints fixed to walls including clamps complete all as specified and directed.
S&F 75 mm bore PVC (SWR) pipes single socketed in any length with rubber rings joints laid in trenches complete all as specified and directed.
S&F 110mm bore PVC (SWR) pipes single socketed in any length with rubber rings joints laid in trenches complete all as specified and directed.
S&F PVC (SWR) bend of 75 mm bore complete all as specified and directed.
S&F PVC (SWR) bend of110 mm bore complete all as specified and directed.
S&F PVC (SWR) branch piece single (Y) equal or unequal of 75 mm bore complete all as specified and directed.
S&F PVC (SWR) branch piece single (Y) equal or unequal of 110 mm bore complete all as specified and directed.
S&F PVC (SWR) junction single (single 'T') equal or unequal of 75mm bore complete all as specified and directed.
S&F PVC (SWR) junction single (single 'T') equal or unequal of 110 mm bore complete all as specified and directed.
S&F PVC (SWR) vent cowl of 75 mm bore complete all as specified and directed.
S&F PVC (SWR) vent cowl of 110 mm bore complete all as specified and directed.
M&L for drilling hole in RCC /brick structure of manholes, etc by drill machine upto a depth of 50mm and 25mm dia, removing dust, etc by vacuum cleaner and blowers, providing and fixing of HD PVC nozzles, 25mm dia, 100 mm long on the concrete/brick walls, floors, etc @ 1.00m centre to centre in both directions and injection of cement slurry mixed with liquid integral water proofing compound [Make: M/s Fosroc Chemicals (India) Pvt Ltd or M/s Pidilite Industries in the ratio as per recommendation of manufacturer] of appropriate consistency through nipple by using standard pressure grouting pump and closing the ends of nipple with epoxy putty/silica jelly after injecting the chemicals complete all as specified & directed by Engr-in-Charge. NOTE: (i) Payment of the item will only be made when no leekage or seepage is observed from the man holes. (ii) In case of seepage/leekage is observed the work will have to be redone till all leekage/seepage are arrested.
M&L for providing and applying on surroundings of joints of pipes (any type) of diameter 100/150 mm with first coat of elastomeric modified polyurethane liquid membrane (Make: ShaliUrethane BTD of M/s STP or Liquiurethane BTD of M/s IWL {a water based single component white coloured polyurethane liquid membrane having solid content over 80% service temperature from minus 20 degree celcius to plus 100 degree celcius, zero VOC content and with excellent UV stablity; conforming to ASTM C-836 and 6083} or TEXPUR of M/s Texa or Hyperdesno of M/s Alchimica or New Flex of M/s WR Grace as approved by GE) at the rate of 0.5 kg per Joint by brush on cleaned surfaces of joints; laying/spreading polyster fleece / 50 gsm non-woven Geo Textile (Make: ShaliGeo Text 50 or ShaliGeo Texi) nylon/glass fibre net with overlap of 50mm while the surface is tacky and allow to dry for 10 to 12 hrs; thereafter applying second coat of elastomeric modified polyurethane liquid membrane (of make as given here-in-before) at the rate of 0.5 Kg per Joint; saturating the reinforcement core and allow it to cure for overnight complete all as specified and directed. NOTE: (i) Payment of the item will only be made when no leekage or seepage is observed from the joint. (ii) In case of seepage/leekage is observed the work will have to be redone till all leekage/seepage are arrested.
M&L for 50 mm Sand stone slabs in foothpath, sunshades, chajjas, shelves, cills, landings, cover stones, templates, etc, n exc. 2m in length, punched dressed on face and along exposed edges, self faced on other side and set and pointed in cement mortar 1:4, complete all as specified and directed.
Schedule of credit (calculation will be done off line) Rs. 28225.00
Shapers Constructions Limited
M/S Shanti Traders
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .