Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹45.1 LAccepted-AOC 704 SILVER DEAL DAFFODIL WING 1 B T KAWADE ROAD PUNE 411 001 | PUNE | PUNE | MAHARASHTRA | 411001 | L1 | Accepted-AOC Being L1 | |
| 2 | L2₹49.9 L+₹4.2 L (9.13%)Rejected-Finance | L2 | Rejected-Finance Not Being L1 |
Tender Value
₹49.9 L
EMD Value
₹99,800
Closing Date
22 Jul 2023, 6:00 pmClosed
GE CENTRAL BANGALORE
ASC CENTRE AND COLLEGE AGRAM POST BANGALORE 560007
REPAIR MIANT OF EXTERNAL ELECTRIFICATION HT LT UG CABLES LT PANEL ACBS MCCBS CABLE JOINT POLE PAINTING WITH OTHER CONNECTED WORKS AT ASC SOUTH OTM AND MD ACCN PCTC AREA VOC AND VNC AREA UNDER GE CENTRAL BANGLORE
2023_MES_605925_1
8329E
Open Tender
Electrical and Maintenance Works
Item Rate
270 days
GE CENTRAL BANGALORE
Please refer tender documents
6 documents required · 6 mandatory
₹500
GE CENTRAL BANGALORE
₹99,800
Yes
22 Sept 2023
27 Jun 2023
24 Jul 2023
27 Jun 2023
22 Jul 2023
5 Jul 2023
27 Jun 2023 - 4 Jul 2023
Amount
Dismantling unserviceable cross arms including clamps, bolts, nuts, washers etc from pole.
Dismantlin of ACSR conductor of any size, from insulator etc from the structure/over head line all as directed.
Dismantling insulators any type, size compelete all as directed.
Dismantling air break gang operated switches triple pole vertical/ horizontal mounted including isulators and opretaing mechanism for replacment all as directed.
Excavation in trenches n.exc 1.5mtr wide and not exc 1.5mtr depth and getting out in soft/loose soil all as directed.
Returning and filling in of excavated soil including spreading,levelling,watering and well ramming in layers not exceeding 25 cm each.
Removal of surplus soil not exceeding 50 mtr and depositing where directed at a level not exceeding 1.5 mtr above the starting point.
M&L for Sand cushioning/sand covering for underground cable protection complete all as specified. Note: Punned thickness only will be measured and paid.
Supply and laying sub class 'B' bricks of old size (standard size as per local availability) laid along alignment of cable as protection to cable in trenches complete all as specified and directed by Engineer-in-Charge
M&L for PCC 1:4:8 type D2 with 40 mm graded aggregate as in foundation complete including demolition of the same complete all as directed.
M&L for PCC 1:3:6 with 20 mm graded aggregate for coping of poles and stay including form work including demolition of the same complete all as directed.
S&F mild steel work in hard rails , winds ties post and structs in fencing screwed or welded to shaped as directed , including all necessary drilling ,bolting or welding etc, and similar work confroming Fe-290 Gde-E-165.
Supply only MS galvanized chain link fencing (120 to 140 gms) 4mm dia and 75mm spacing and weighing not less than 2.75 kg/sqm diagonally pinned including line wire rails, straining bolts and provision of binding wire complete all as specified and as directed. Make : M/s Sachin , TATA or any approved make as approved..
Fixing only diagonally pinned fencing wire including line wire, any mesh size and type of standards, rails, straining bolts etc. including provision of binding wire complete all as directed.
S&F mild steel screw bolts of 12-15 mm diameter of shank (machine made) with hexagonal or square heads at one end and screwed the other, each screwed end to be fitted with washers and one hexagonal or square nut, length of bolt exceeding 22.5 cm but not exceeding 30 cm long complete all as specified.
Supply and fixing in repair GI tubing light grade 50 mm dia for protection of cable on pole , under road crossing or across drain , along electric pole or floor /wall along with suitable size of MS claps , nuts & bolts etc complete all as specified and directed . ( Note: Excavation / earth work shall be measured and paid separately under relevant items of Sch ‘A’
All as per item No 16 here-in-before but dia of pipe 40 mm .
All as per item No 16 here-in-before but dia of pipe 80 mm .
Supply, fabricate and fix cross arms any size along with, brackets, clamps, bolts, nuts, washers, bracers etc including drilling holes, cold/hot complete and fixed to pole including one primer coat and one under and finishing coat of paint.
S&F of ACSR conductor of any size as ordered by Engr-in-charge including tightening and bindingh with new binding wires to insulators all as directed.
S&F pin type insulator vitreous, white, brown, or green insulator includig one galvanised mild steel spindle, two galvanised iron washers and one galvanised iron nut 150 mm height, 150 mm dia for 11000 volts grade.
S&Ft disc type insulator, porcelain, vitreous 145 mm high and 255 mm dia ball and socket type white, brown or green, single disc assembly for tension with tension clamps for conductors, working pressure 11000 Volts
M&L anti climbing device, spikes type fabricated out of MS bars (round/square/flat) including nuts,bolts, washers and welding in two halves made to shape to suit the cross section of the pole including dismantling old one.
S&F danger notice plate of 1.6 mm thick mild steel sheet, vitreous enamelled white, with letters, figures and conventional skull and bones in signal red colour and fixed with MS clamps,bolts, nuts of approved size for HT 25x20 cm size including dismantling old one.
S&F danger notice plate of 1.6 mm thick mild steel sheet, vitreous enamelled white, with letters, figures and conventional skull and bones in signal red colour and fixed with MS clamps,bolts, nuts of approved size for LT 20x15 cm size including dismantling old one.
Filtration of transformer oil of transformers/ FRMUs installed at various locations to achieve di-electric strength not less than 65 KV for 1 minute at 2.5mm gap as per relevant IS with portable filtration plant, testing of the oil for the di-electric strength before filtration and after filtration complete all as directed by the Engineer-in-Charge.
Supply and topping up of transformer oil with di-electric strength not less than 50 KV in to the conservator tank/ body tank of the transformer/VCB/ FRMUs etc at various locations complete all as directed by the Engineer-in-Charge. [Make: Poweroil/ Transol/ Sabitha Chemicals]
M&L for replacement of silica gel breather assembly for HT/ LT distribution transformers of 250 to 500 KVA capacity including dismantling old one.
All same as per item No 28 here-in-above but up to 250 KVA capacity -do-
M&L for replacement gun metal drain valves of transformers of 100 to 250 KVA capacity including dismantling old one:- MAKE :- UPADHYAY/ LEADER/ ZOLOTO/ VAG
All same as per item No 30 here-in-above but up to 300 to 350 KVA -do-
M&L for replacement of the LT porcelain bushings complete of Up to 500 KVA capacity distribution transformers of existing transformer make/ size/ type all as directed including dismantling old one.
M&L for replacement of the HT porcelain bushings complete of Up to 500 KVA capacity distribution transformers of existing transformer make/ size/ type all as directed including dismantling old one.
M&L for replacement of the LT bushing rod made out of gun metal with threading & of suitable length/ size all as per existing including metal rings/ bolts/ washers/ rubber rings etc. complete Up to 100 KVA capacity distribution transformers of any make/ size/ type all as directed including dismantling old one.
All same as per item No 35 here-in-above but 160 to 250 KVA
All same as per item No 35 here-in-above but 250 to 350 KVA
M&L for replacement of the HT bushing rod made out of gun metal with threading & of suitable length/ size all as per existing including metal rings/ bolts/ washers/ rubber rings etc. complete Up to 500 KVA capacity distribution transformers of any make/ size/ type all as directed including dismantling old one.
M&L for replacement of (OTI) Oil Temperature indicator Up to 100 KVA distribution transformers including dismantling old one.
All same as per item No 38 here-in-above but 160 to 250 KVA
All same as per item No 38 here-in-above but 250 to 350 KVA
M&L for preparation of old painted surfaces of 63 KVA to 160 KVA capacity in-door/ out-door type transformer with coarse cloth/ brush and painting throughout externally on exposed surfaces with two coats of smoke grey colour synthetic enamel paint including writing of transformer details on plinth in white enamel paint on black enamel paint back ground complete including one coat of white wash for base foundation all as specified and directed by Engineer-in-charge .
All same as per item No 41 here-in-above but 200 KVA to 350 KVA
M&L for repair and servicing of HT 11 KV Four pole structure by replacing galvanized PG clamps, GI bolts and nuts, pieces of ACSR conductor with insulation of any size as jumpers including lubricating the moving parts of AB switch and cleaning of all disc /pin insulators and applying silicon compound for prevention of arcing due to dust/ salt deposits over the surfaces including applying one coat of zinc oxide primer on rusted portions after preparation of surfaces & a coat of aluminum paint to the entire structure and triming of tree branches sourrounding of structre complete all as directed. Note:-Rate quoted shall be inclusive of two coats of white wash on exposed concrete surfaces, ACSR conductor for jumpering, GI hard ware like nuts, bolts etc complete
All same as per item No 43 here-in-above but for two pole structure
S&F GOD switches air break gang vertical / horizontal operated, triple pole mechanically operated mounted on insulator and steel frame with operating mechanism worked from ground level, for current rating up to 400 Amps.
Taking down old DO fuse unit S &F expulsion fuse single phase above 50 & up to 100 AMPS capacity, 11000 Volts.
Taking down existing unserviceable Lightning arresetor and S&F lightning arresters expulsion type complete with all fittings transmission class, discharge capacity 10 KA suitable for 11000 Volts line
M&L for replacement of galvanised iron strip 32x6 mm buried in ground or fixed on pole with all accessories including dismantling old one.
Earthing complete with Galvanised Steel earthplate of size 60x60cmx6.3mm thick electrode and 32x6mm GI strip as earth lead, buried directly in ground (earth pit not less than 2.25m deep below ground level) with top edge of the plate not less than 1.5m below ground level, connected to 32x6mm earth strip by means of nuts, bolts, check nuts and washers of GI all as shown in electrical plate No.5 of SSR Part-I, connected to earth test terminal point all as specified or as indicated including testing on completion (Rates inclusive of neccessary excavation in any type of soil, earth work, PCC pit, CI cover, funnel with watering pipe, suitable size of light grade GI Protection pipe for earth strip in ground etc. all as required at site for complete earthing).
M&L cable jointing kit for 11 KV (Earthed) grade XLPE cable for outdoor end termination heat shrinkable type joint complete with jointing material and accessories suitable for size 3 core 120 to 185 Sqmm including testing after jointing complete all as directed .
M&L cable jointing kit for 11 KV (Earthed) grade XLPE cable for outdoor end termination heat shrinkable type joint complete with jointing material and accessories suitable for size 3 core 50 to 95 Sqmm including testing after jointing complete all as directed .
M&L cable jointing kit for 11 KV (Earthed) grade XLPE cable for straight through heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armored aluminium conductor cable of size 240 Sqmm including testing after jointing complete all as directed .
M&L cable jointing kit for 11 KV (Earthed) grade XLPE cable for straight through heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armored aluminium conductor cable of size 120 to 185 Sqmm including testing after jointing complete all as directed .
M&L cable jointing kit for 11 KV (Earthed) grade XLPE cable for straight through heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armored aluminium conductor cable of size 50 to 95 Sqmm including testing after jointing complete all as directed .
S&L XLPE insulated,screened, PVC bedded galvanised steel strip or wire armoured ,electric power cables heavy duty with aluminium conductor, 11000 Volts grade ( earthed) of size 3 core 95 Sqmm complete in trenches/ ducts/ on pole etc complete all as directed . Make: Universal/ Nicco/ Polycab
M&L for detecting HT/ LT UG cable faults located in any stretch/ depth with sophisticated cable fault locator consisting of microprocessor based pre-locator system, HV surge generator, fault pin point surge wave reciever, cable indentification instrument , cable tracer for exact location of under ground cable routes. Note: The rate quoted deemed to be inclusive of rental charges for T&P like entire cable fault locating instrument, Charges for operator and transportation etc complete
Provision of trenchless bore using mechanical numatic drilling equipment for passing electric cables through HDPE pipe of 100mm dia under the existing bituminous/WBM road/PCC hard standings, depth range not less than 1.0 mtr and upto 1.5mtr and making good to the distrubed surfaces of road to match with its existing specifications all as specified and directed by engr-in-charge at site. Note : 1. Quoted rates deems to be inclusing of necessary earth work, transportation charges of Drilling machine, and cost of HDPE pipe and passing pipe through bore complete. 2. Any damage to MES assets caused during trenchless bore shall be recitfied by the contractor at his own cost.
Material & labour for decarbonising of LT panel board of any size/ capacity made out of thermoplastic-polycarbonate boxes with IP-65 protection by taking shut down of panel & strip opening of boxes carefully, cleaning the carbon content with CTC solution, replacement of embedded polyurethane gasket,replacement of pitted control wiring, thimbles ,replacement of nuts, bolts ,washers, cable glands/ PVC gromates, cable lugs, tightening the busbar chamber, dismantling the broken/ defective boxes, inspection of Ammeters/ Voltmeters/ Multifunction meters re-assembling after replacement of new boxes, testing & commissioning,INCLUDING painting with a coat of synthetic enamel spray painting all as per existing colour complete all as directed. Note : The defective thermoplastic-polycarbonate boxes, LED Lamps,Ammeters , Voltmeters, Multifunction meters, CTs will be measured and paid separately under relevant schedule items .
(d) CTs moulded type class-1.0, 5VA burden suitable for AC 230V (phase-earth )50 Hz supply busbar system of suitable for ratio range 100 to 800/5 Amps capacity
(e) LED Indication Lamps Make: Neptune/L&T /Schneider/ /Havells/EPCOS/Hager / ABB
Supply & Laying in trenches or fixing on wall or passing through pipe or in cable ducts, 1100 volts grade 16 Sqmm 4 core XLPE insulated , armoured, electric power cables (heavy duty) with aluminium conductor including dismantling old one. Note: The rate quoted inclusive of termination at ends with suitable aluminium lugs wherever required. Make: Paragon/Havells/Polycab/ Nicco
All same as per item No 64 here-in-above but 25 Sqmm 4 core
All same as per item No 64 here-in-above but 3.5 core 35 Sqmm
All same as per item No 64 here-in-above but 3.5 core 50 Sqmm
All same as per item No 64 here-in-above but 3.5 core 70 Sqmm
All same as per item No 64 here-in-above but 3.5 core 95 Sqmm
All same as per item No 64 here-in-above but 3.5 core 120 Sqmm
All same as per item No 64 here-in-above but 3.5 core 150 Sqmm
All same as per item No 64 here-in-above but 3.5 core 185 Sqmm
M&L for dismantling the cable connections of four pole/ three pole Air circuit breaker of capacity 630 to 800 Amps ,415 V 50 HZ of L&T Make/C&S/GE/ABB make, strip opening the Air circuit breaker, inspecting the parts for serviceability/overhauling complete and carrying out the following repairs/maintenance :- a) Cleaning the insulation parts including bushings with CTC solution.b) Checking the alignment and condition of movable and stationary contacts and adjust them all as per manufacturer's instructional manual c) Check the bolts, nuts, washers, cotter pins and all terminal connections are in place and tights. Replace the worn-out parts.d) Check arc chutes for damage .e) Clean and lubricate the operating mechanism with a light machine oil for pins and bearings and with a non-hardening grease for the wearing surfaces . Adjust breaker operating mechanism all as per manufacturer's instructional manual . f) Checking / inspecting shunt trip coil for serviceability and replacing the same if required. g) Checking control device free for operation.j) Check after servicing the circuit breaker to verify the contacts move to the fully opened and fully closed positions, that there is an absence of friction and that the electrical operation is functional Note : The rate quoted deemed to be inclusive of T&P and minor spares like lubricants, nuts/bolts/washers/ pins etc. Major spares like Shunt release & trip coil etc will be measured & paid separately under relevant schedule items
Supply only CTs suitable for air circuit breakers of rating 630 Amps to 800 Amps as all per existing of Make: L&T/C&S/ GE/ABB/Havells/Hager
Supply only auxiliary contact block suitable for air circuit breakers of rating 630 Amps to 800 Ampsas all per existing of Make: L&T/C&S/ GE/ABB/Havells/Hager
Supply only arcing contacts (fixed/ moving) suitable for air circuit breakers of rating 630 Amps to 800 Amps as all per existing of Make: L&T/C&S/ GE/ABB/Havells/Hager
Supply only arc chutes (for 415 V) suitable for air circuit breakers of rating 630 Amps to 800 Amps as all per existing of Make: L&T/C&S/ GE/ABB/Havells/Hager
Supply only shunt release (110 /220 V DC or 240 V/415 V AC) suitable for air circuit breakers of rating 630 Amps to 800 Amps as all per existing of Make: L&T/C&S/ GE/ABB/Havells/Hager
Supply only cluster contact suitable for air circuit breakers of rating 630 Amps to 800 Amps as all per existing of Make: L&T/C&S/ GE/ABB/Havells/Hager
Supply only trip coil suitable for air circuit breakers of rating 630 Amps to 800 Amps as all per existing of Make: L&T/C&S/ GE/ABB/Havells/Hager
Supply & fixing in repairs of MCCBs of following current carrying capacity including necessary connecting terminals to bus bar, nut bolts etc as per site suitable complete all as directed .(a) 100 to 125 Amps, 3P,Adjustable type, 415 V MCCB, 16KA rating Make: L&T/Hager/Havells/ Indoasian/Schneider/ABB
All same as per item No 81 here-in-above but 63 to 100 Amps, 3P, 415 V MCCB, 16KA rating
All same as per item No 81 here-in-above but 4 Pole MCCB, 415 V, Adjustable type with breaking capacity 36 KA, 400 A rated
All same as per item No 81 here-in-above but 4 Pole MCCB, 415 V, Adjustable type with breaking capacity 25 KA, 250 A rated
All same as per item No 81 here-in-above but 4 Pole MCCB, 415 V, Adjustable type with breaking capacity 25 KA, 200 A rated
All same as per item No 81 here-in-above but 4 Pole MCCB, 415 V, Adjustable type with breaking capacity 25 KA, 160 A rated
All same as per item No 81 here-in-above but 4 Pole MCCB, 415 V, Adjustable type with breaking capacity 25 KA, 100A rated .
M&L for heat shrinkable straight through joint for LT UG cable including jointing kits complete for making joints suitable for aluminium conductor cable of size 3.5/ 4 core 25 to 50 sq.mm.Make :- M-SEAL / BIRLA 3 M LTD / DENSON /RAY CHEM
All as per Item No.88 herein before but for cable of size 3.5 core 70 to 150 sq.mm.
All as per Item No. 88 herein before but for cable of size 3.5 core 185 to 400 sq.mm.
M&L for heat shrinkable end termination joint for LT UG cable including jointing kits complete for making joints suitable for aluminium conductor cable of size 3.5/ 4 core 16 to 50 sq.mm.Make :- M-SEAL / BIRLA 3 M LTD / DENSON /RAY CHEM
All as per Item No. 91 herein before but for cable of size 3.5 core 185 to 400 sq.mm.
M & L for disconnecting carefully electrical connection of LT Automatic power factor correction (APFC) Panel of any existing Make: for supply range 3 Phase 415 V & 50 Hz system of 100 to 75 KVAR capacity installed at various locations, inspecting/servicing the APFC panel complete, calibration of meters, checking the serviceability of items such as MD-XL capacitors, capacitor duty contactors, APFC relay, MCCB/ACB/Contactors , replacing the pitted control wiring, ventilation fan, checking / replacing defective LED lamps/ Multifunciton meters/ Ammeters/Voltmeters/ Push button switches, CTS etc including replacement of pitted aluminium lugs of power cable/ Aluminium conductor cable for connecting APFC panel to Main incoming panel etc complete, including re-assembling, painting with a coat of synthetic enamel spray painting all as per existing colour, including testing, commissioning etc complete all as speciifed and directed. Note :- (a) The rate quoted deemed to be inclusive replacement of copper control wiring, ventilation fan,calibration of meters, complete inspection/servicing of APFC panel for repairs.(b) Spares such as MCCBs, capacitors, capacitor duty contactors, APFC relay, LED lamps/ Ammeters/Voltmeters/ Push button switches, CTs , will be measured and paid separately.(c) The M/L PVC XLPE Aluminium conductor power cable will be measured and paid separately.
All same as per item No 93 here-in-above but 35/45/25/10 KVAR
(b) CTs moulded type class-1.0, 5VA burden suitable for AC 230V (phase-earth )50 Hz supply busbar system of suitable for ratio range125/5 Amps capacity
(c) LED Indication Lamps Make: Neptune/L&T/Schneider//Havells/EPCOS
(d) LED type push button actuators. Make: Neptune/L&T/Schneider//Havells/EPCOS
(e) 6/10/16A, 10 KA MCB SP, C curve type Make: ABB/L&T/schneider //Havells/EPCOS
(f) 32 A 10 KA MCB TP, C curve type Make: ABB/L&T/schneider //Havells/EPCOS
(g) Capacitor duty contactor with 1 No Aux contact 230V AC coil voltage suitable for minimum 10 KVAR capacitor. Make: ABB/Schneider/L&T /Havells/EPCOS
(h) Capacitor duty contactor with 1 No Aux contact 230V AC coil voltage suitable for minimum 25 KVAR capacitor. Make: ABB/Schneider/L&T /Havells/EPCOS
(j) Double metalised paper and polypropylene technology ( Mixed Dielectric) capacitor cylindrical/box type for power factor correction of 440 V, 50 HZ rated of capacity 3 to 15 KVAR. Make: L&T/Neptune-Ducati / Schneider/Havells/EPCOS
(k) Double metalised paper and polypropylene technology ( Mixed Dielectric) capacitor cylindrical/box type for power factor correction of 440 V, 50 HZ rated of capacity 20 to 25 KVAR. Make: L&T/Neptune-Ducati / Schneider/Havells/EPCOS
(m) APFC relay with inbuilt PF meter suitable for 5A CTR suitable for 8 Stage. Make: Neptune-Ducati RM-8/ L&T/ Schneider//Havells/EPCOS
(n) APFC relay with inbuilt PF meter suitable for 5A CTR suitable for 12 Stage. Make: Neptune-Ducati RM-12/ L&T/ Schneider//Havells/EPCOS
Supply, erecting and fixing in true vertical position, steel tubular swaged pole (410 SP – 31), 09 mtr long, complete with cast iron base plate, pole cap / finial taper plug, bolts, nuts and washers, welded reduced section and longitudinal weld throughout entire length of pole with and including necessary earth work in any type of soil and disposal of surplus soil to a distance not exceeding 50 mtr, PCC (1:4:8) type D-2 (using 40 mm graded sand stone aggregate) in the base and foundation upto ground level and PCC (1:2:4) type B-1 (using 20 mm graded black trap/granite/basalt stone aggregate) for coping of the pole including necessary form work including 2 coats of black bituminous paint externally upto planting depth and remaining exterior portion of pole shall be provided with one coat of red oxide primer and two coats of aluminium paint and including making alternate white and black strips 30 cms height (05 Nos strips) numbering the poles by 2" height 06 Nos letters complete all the metallic surfaces all as specified and directed by Engineer-in-Charge.
Design, fabrication, installation and testing of LT out door type factory made(CPRI Approved), junction box of size 900mm(H)X700mm(B)X400mm(W) (over all dimension) made out of 3.0mm thick CRCA sheet dully supported with mild steel angle iron of size 40X40X5 mm frame, 04 Nos aluminium bus bar of of capacity 250 Amps with drilled hole for incoming/outgoing cable connection with necessary aluminium lungs, GI nuts bolts and washer including 08 Nos bridge insulator DMC , heavy duty, suitable for 3 Phase 4 wire system, one danger notice plate of 1.6mm thick mild steel sheet, vitreous enameled white with letters, figures and conventional skull & bones in signal red colour and fixed in front door size and PCC (1:3:6) type C-1 foundation 0.30m above normal ground level & 0.30m below ground level with necessary exacavation and earth work and painting to internal and external steel surface with powder coated (Siemence grey) RL-35 after neccesary preparation of surfaces including Indicating lamp LED type 240V 50 Hz AC -one set of 3 Make: L&T/Legrand/ ABB/Siemens/Havells compete all as directed.
Design, Fabrication, supply, installation, commissioning and testing Double Door Panel board manufactured from CPRI approved firm with canopy head, out door, cubical type panel board of over all min dimension 1.2 m (L) X 1.00m (H) X 0.50m (W) fabricated with 3.0mm thick CRCA sheet on mild steel angle iron 50X50X6 mm thick frame, totally enclosed type dust & vermin proof back side open-able fixed with hinged shutter and front side open-able with hinged shutter and locking arrangement for individual MCCBs/MCBs , powder coated finished both internally and externally suitable for 415Volt AC 50 Hz 3 Phase 4 wire system by means of Alluminium bus bar of 250 Amps Capacity (Main bus bar ) and 800 Amps Loop Bus bar with coloured insulating tape/sleeves mounted on porcelain or synthetic insulators with provision for fixing MCCBs/MCBs necessary inter connections with Aluminium bar/strip duly coloured code insulation and providing under mentioned equipments & accessories including connections of all out going/in coming existing/New cables of required size and including PCC foundation in 1:3:6, type C1 of 0.5 mtrs height above GL and 0.30mtrs below GL including necessary earth work complete all as specified and as directed. (a) INCOMING: MCCB 4 pole 450Amp,Icu=Ics=25KA, Adjustable thermal and adjustable Magnetic setting with extended terminals - 01No Make: L&T/Legrand/ ABB/Siemens/Havells (b) OUTGOING: MCCB 4 pole 160Amp,Icu=Ics=25KA, Adjustable thermal and adjustable Magnetic setting with extended terminals -03 Nos Make: L&T/Legrand/ ABB/Siemens/Havells (c) O/G MCB TPN 63Amp, 10KA,C curve - 02 Nos . Make: Legrand cat No 408683 or equivalent model of L&T/ ABB/Siemens/Havells. (d) Indicating lamp LED type 240V 50 Hz AC -one set of 3 .Make: L&T/Legrand/ ABB / Siemens / Havells
S&F single side painted flex glow sign board of 1.80X1.00X0.25 Mtrs size fabricated with 20mm mild steel square hollow pipe frame work, front side and back side covered with Aluminium sheet side openable type including writing latter diagram, photoghraphy and making design covering the front surface as directed by Engr-in -Charge including providing 2X20 Watt LED tube light inside sign board for glow with necessary electrical connection. Glow sign board shall be standed at 1.2 mtrs above ground level by means of 40X40X5mm thick MS angle iron post duly embeded in PCC 1:3:6 type C1 foundation block of size 300X300X450mm depth, painting to iron members complete all as directed.
Shifting of transformer from one place to another place by using of Hydra /Crane or other transport etc to a distance not more than 5 Km and placing in/over platform/foundation of Transformer complete all as specified and as directed.
Clearing of bushes/small plants upto root level around and surroundings areas E/M installations (i.e.Two Pole/ Four structures, outdoor-substation yards, pump house & STP installations etc) including surface dressing n.exc 15 cm deep and removing debris to a distance n.exc 50m complete all as directed
Supply and spread stone metal graded aggregate of size 40 mm at transformer yard complete all as directed by Engr-in-Charge.
Taking out exixting stone metal / aggregrate any size and stacking aside at site where directed for reuse / re-spreading including cleaning , removing grass , vegetation etc to the satisfaction of Engineer-in-charge and finally spreading the stacked stone metal as ordered in existing position complete all as directed. (Note : Quoted rate is deemed to be inclusive of removing of stoe / relaying ,cleaning the entrire area ).
RAMSON TRADERS
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .