| Sl No | Description | Qty | Unit | CRS AND COMPANY L3 | MANJUNATH M L2 | K MURALI L1 |
|---|---|---|---|---|---|---|
| 1.00Supply, Installation, Testing and Commissioning of Inverter Type Split Air Conditioning Units and Providing and Fixing of Mineral Fiber Acoustic False Ceiling with GI T-Grid Suspension System | ||||||
| 1.01 | Providing and fixing of 16 mm thick Mineral Fibre Acoustic Ceiling Tiles of size 600 x 600 mm of approved texture, design and pattern to match with the existing false ceiling design across the C-DOT Campus (Approved make: Armstrong – Minatuff RH99 / DUNE RH-99, Micro Look or equivalent as
approved by the Engineer-in-Charge), having Humidity Resistance (RH) of 99%, Light Reflectance ≥ 85%, Thermal Conductivity k = 0.052–0.057 W/m·K, NRC Value > 0.65, and Fire Performance as per BS 476 Part 6 & 7, in true horizontal
level, suspended on interlocking Hot Dipped All Round GI T-Grid system of 0.33 mm thick (galvanised @ 120 GSM) comprising Main T-Runners of 15 x 32 mm x 3000 mm, Cross Tees of 15 x 32 mm x 1200 mm and Secondary Cross Tees of 15 x 32 mm x 600 mm, forming a grid module of 600 x 600 mm to match the existing grid pattern; the grid suspended from the ceiling / soffit using 6 mm dia fully threaded GI hanger rods up to 1000 mm length with L-shape level adjusters of 85 x 25 x 2 mm and M-6 Dash Fasteners, spaced at 1200 mm c/c
along Main T-Runners; GI Perimeter Wall Angle of 24 x 24 mm (0.40 mm thick) fixed to walls with plastic rawl plugs at 450 mm c/c and 40 mm long SS dry wall screws; all exposed bottom portions of T-sections to be pre-painted with
polyester baked paint; necessary provisions for electrical light fixtures and cable routing to be made and finished properly, the rate being inclusive of the same; for all heights, all complete as per drawings, specifications, and directions of the
Engineer-in-Charge. 45 sqm | 45 | Sq Meters | 86,625 ₹1,02,217.5 Lowest | 92,250 ₹1,08,855 | 99,000 ₹1,16,820 |
| 1.02 | Supplying , Installation, Testing and Commissioning of Air Cooled 2 TR Inverter type along with 4 KVA capacity voltage stabilizer. The AC should be 5 star BEE rating Hi Wall split type Air conditioners complete with Indoor unit(IDU), Out door unit (ODU), surface / concealed copper Refrigerant piping with insulation (closed cell elastomeric nitrile rubber tubular pipe section) upto 3 Mtr (IDU to ODU), copper power cable upto 3.5 Mtr (IDU to ODU) i/c drain pipe R-32/R-410/ R-407 Green Refrigerant, wireless Remote control, suitable for working between 180- 260V with low & high voltage cut-off and 50 hz ,1 phase AC supply capable of performing cooling ,dehumidification, air circulation of following capacity with Scroll / rotary compressor. The system shall be able
to deliver 100% of the rated capacity upto 42 Deg.C. Min 10 years Original Equipment Manufacturer (OEM) warranty for compressor and 5 years for Printed Circuit Board (PCB) . Must comply : Electrical cable IS 694 or IS 9968 temperature sensing control IS /International Electro technical Commission
(IEC) 60730, hermetic compressor IS 10617, heat exchanger IS 11329, capacitor IS 2993 and motor IS 12615. Complete as per CPWD specification and IS : 1391 Part II 2023.
AC - Preferred Make: Blue star/ Voltas/ Carrier/ LG/ Daikin.
Stabilizer – Preferred Make : Everest, V-Guard, Havells. | 1 | No | 1,56,000 ₹1,84,080 | 75,000 ₹88,500 | 59,860 ₹70,634.8 Lowest |
Tender Value
Refer Docs
Closing Date
16 Jun 2026, 9:00 amClosed
Manager- Purchase
CDOT Campus, Electronic City Phase I Bangalore
Supply, Installation, Testing and Commissioning of Inverter Type Split Air Conditioning Units and Providing and Fixing of Mineral Fiber Acoustic False Ceiling with GI T-Grid Suspension System
2026_CDOT_909124_1
C-DOTB/TENDER/2026-2027/002
Open Tender
Civil Works
Turn-key
30 days
CDOT Campus, Electronic City Phase I Bangalore
as per tender document
3 documents required · 3 mandatory
₹0
Exempted
CDOT Campus, Electronic City Phase I Bangalore
22 Jul 2026
27 May 2026
18 Jun 2026
27 May 2026
16 Jun 2026
4 Jun 2026
27 May 2026 - 3 Jun 2026
4 Jun 2026
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount | GST % |
|---|---|---|---|---|---|---|
| 1Supply, Installation, Testing and Commissioning of Inverter Type Split Air Conditioning Units and Providing and Fixing of Mineral Fiber Acoustic False Ceiling with GI T-Grid Suspension System | ||||||
| 1.01 | Providing and fixing of 16 mm thick Mineral Fibre Acoustic Ceiling Tiles of size 600 x 600 mm of approved texture, design and pattern to match with the existing false ceiling design across the C-DOT Campus (Approved make: Armstrong – Minatuff RH99 / DUNE RH-99, Micro Look or equivalent as
approved by the Engineer-in-Charge), having Humidity Resistance (RH) of 99%, Light Reflectance ≥ 85%, Thermal Conductivity k = 0.052–0.057 W/m·K, NRC Value > 0.65, and Fire Performance as per BS 476 Part 6 & 7, in true horizontal
level, suspended on interlocking Hot Dipped All Round GI T-Grid system of 0.33 mm thick (galvanised @ 120 GSM) comprising Main T-Runners of 15 x 32 mm x 3000 mm, Cross Tees of 15 x 32 mm x 1200 mm and Secondary Cross Tees of 15 x 32 mm x 600 mm, forming a grid module of 600 x 600 mm to match the existing grid pattern; the grid suspended from the ceiling / soffit using 6 mm dia fully threaded GI hanger rods up to 1000 mm length with L-shape level adjusters of 85 x 25 x 2 mm and M-6 Dash Fasteners, spaced at 1200 mm c/c
along Main T-Runners; GI Perimeter Wall Angle of 24 x 24 mm (0.40 mm thick) fixed to walls with plastic rawl plugs at 450 mm c/c and 40 mm long SS dry wall screws; all exposed bottom portions of T-sections to be pre-painted with
polyester baked paint; necessary provisions for electrical light fixtures and cable routing to be made and finished properly, the rate being inclusive of the same; for all heights, all complete as per drawings, specifications, and directions of the
Engineer-in-Charge. 45 sqm | 45 | Sq Meters | - | - | 18% |
| 1.02 | Supplying , Installation, Testing and Commissioning of Air Cooled 2 TR Inverter type along with 4 KVA capacity voltage stabilizer. The AC should be 5 star BEE rating Hi Wall split type Air conditioners complete with Indoor unit(IDU), Out door unit (ODU), surface / concealed copper Refrigerant piping with insulation (closed cell elastomeric nitrile rubber tubular pipe section) upto 3 Mtr (IDU to ODU), copper power cable upto 3.5 Mtr (IDU to ODU) i/c drain pipe R-32/R-410/ R-407 Green Refrigerant, wireless Remote control, suitable for working between 180- 260V with low & high voltage cut-off and 50 hz ,1 phase AC supply capable of performing cooling ,dehumidification, air circulation of following capacity with Scroll / rotary compressor. The system shall be able
to deliver 100% of the rated capacity upto 42 Deg.C. Min 10 years Original Equipment Manufacturer (OEM) warranty for compressor and 5 years for Printed Circuit Board (PCB) . Must comply : Electrical cable IS 694 or IS 9968 temperature sensing control IS /International Electro technical Commission
(IEC) 60730, hermetic compressor IS 10617, heat exchanger IS 11329, capacitor IS 2993 and motor IS 12615. Complete as per CPWD specification and IS : 1391 Part II 2023.
AC - Preferred Make: Blue star/ Voltas/ Carrier/ LG/ Daikin.
Stabilizer – Preferred Make : Everest, V-Guard, Havells. | 1 | No | 65 | ₹65 | 18% |
stage.html
html • 0.04 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.22 MB
Tendernotice_2.pdf
PDF • 0.76 MB
BOQ_956538.xls
BOQ • 0.39 MB
DateCorrigendum.pdf
PDF • 0.27 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .