Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | l1₹1.4 LAccepted-Finance | l1 | Accepted-Finance LOWEST BIDDER L1 | |
| 2 | L2₹1.7 L+₹26,432 (18.8%)Rejected-Finance 92 M DHARAMPUR DHARAMPUR SHAHPUR VILLAGE TOWN SHAHPUR CITY GORAKHPUR GORAKHPUR UTTAR PRADESH 273006 INDIA | GORAKHPUR | UTTAR PRADESH | 273006 | L2 | Rejected-Finance LOWEST BIDDER L2 | |
| 3 | l3₹1.8 L+₹41,300 (29.4%)Rejected-Finance 123 716 GADARIAN PURWA KANPUR NAGAR UTTAR PRADESH 208023 | KANPUR NAGAR | UTTAR PRADESH | 208023 | l3 | Rejected-Finance LOWEST BIDDER L3 |
| Sl No | Description | Qty | Unit | Harshit Enterprises L1 | M/S SUPER TRADING COMPANY L3 | M/S V P ASSOCIATES WORKS PRIVATE LIMITED L2 |
|---|---|---|---|---|---|---|
| 1.00Work involves cleaning of porcelain of drive insulator and porcelain of vaccum interrupter from outside of each pole and sealing the vaccum pole by applying anabond.Checking & adjustment of snatch gap,travel of drive insulater rod & tie rod of each pole.Opening,repairing of breaker mechanism including welding,drilling,machininh and filling of materials if required and proper fitting of it in breaker cubical.Oilng and greasing of crank gears by opening of lock pin etc.Replacement of worn out parts such as bushes,ring,lockpins and trip latch etc.Checking & adjustment of oil daspot of breaker for its damping action.After major overhaulling and repairing of VCBs ,following tests are to be carried out.Opening and colsing time of breaker of each pole.Carrying out contact Resistance Measurement (CRM test)of each pole.Checking of meggar values of breaker poles.Checking tripping of breaker at 70 % DC voltage.Checking the CLOSE/OPEN operation of breaker from Remote & Local.finally prepare and submit the site overhaulling report of each breaker in 03 nos. copies. | ||||||
| 1.01 | 132KV Substation Shatrughanpur | 1 | Job | 17,000 ₹17,000 Lowest | 22,000 ₹22,000 | 20,200 ₹20,200 |
| 1.02 | 132KV Substation Mohaddipur Old | 1 | Job | 17,000 ₹17,000 Lowest | 22,000 ₹22,000 | 20,200 ₹20,200 |
| 1.03 | 132KV Substation FCI old | 1 | Job | 17,000 ₹17,000 Lowest | 22,000 ₹22,000 | 20,200 ₹20,200 |
| 1.04 | 132KV Substation FCI New | 1 | Job | 17,000 ₹17,000 Lowest | 22,000 ₹22,000 | 20,200 ₹20,200 |
| 1.05 | 132KV Substation Kasia | 1 | Job | 17,000 ₹17,000 Lowest | 22,000 ₹22,000 | 20,200 ₹20,200 |
| 1.06 | 132KV Substation Rajapakar | 1 | Job | 17,000 ₹17,000 Lowest | 22,000 ₹22,000 | 20,200 ₹20,200 |
| 1.07 | 220KV Substation Hata | 1 | Job | 17,000 ₹17,000 Lowest | 22,000 ₹22,000 | 20,200 ₹20,200 |
Tender Value
Refer Docs
EMD Value
₹2,000
Closing Date
5 Oct 2026, 5:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
EXECUTIVE ENGINEER ETD-I GORAKHPUR
OFFICE OF THE EXECUTIVE ENGINEER, ETD-I, GORAKHPUR
Overhauling and repairing of 33 KV VCB of different 33 KV feeder at Various 132 KV Sub station UNDER ETD-I GORAKHPUR.
2026_UPTCL_1185068_2
13-ETD-I(G)/2026-27
Open Tender
Electrical Works
Item Rate
90 days
GORAKHPUR
Please refer Tender documents.
2 documents required · 2 mandatory
₹590
EXECUTIVE ENGINEER ELECTRICITY TRANSMISIION DIVISI
₹2,000
EE, ETD-I, Gotakhpur
6 Oct 2026
26 Sept 2026
6 Oct 2026
26 Sept 2026
5 Oct 2026
26 Sept 2026
26 Sept 2026
180 days
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1Work involves cleaning of porcelain of drive insulator and porcelain of vaccum interrupter from outside of each pole and sealing the vaccum pole by applying anabond.Checking & adjustment of snatch gap,travel of drive insulater rod & tie rod of each pole.Opening,repairing of breaker mechanism including welding,drilling,machininh and filling of materials if required and proper fitting of it in breaker cubical.Oilng and greasing of crank gears by opening of lock pin etc.Replacement of worn out parts such as bushes,ring,lockpins and trip latch etc.Checking & adjustment of oil daspot of breaker for its damping action.After major overhaulling and repairing of VCBs ,following tests are to be carried out.Opening and colsing time of breaker of each pole.Carrying out contact Resistance Measurement (CRM test)of each pole.Checking of meggar values of breaker poles.Checking tripping of breaker at 70 % DC voltage.Checking the CLOSE/OPEN operation of breaker from Remote & Local.finally prepare and submit the site overhaulling report of each breaker in 03 nos. copies. | |||||
| 1.01 | 132KV Substation Shatrughanpur | 1 | Job | - | - |
| 1.02 | 132KV Substation Mohaddipur Old | 1 | Job | - | - |
| 1.03 | 132KV Substation FCI old | 1 | Job | - | - |
| 1.04 | 132KV Substation FCI New | 1 | Job | - | - |
| 1.05 | 132KV Substation Kasia | 1 | Job | - | - |
| 1.06 | 132KV Substation Rajapakar | 1 | Job | - | - |
| 1.07 | 220KV Substation Hata | 1 | Job | - | - |
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.13 MB
TechnicalBid13.pdf
Tender Documents • 0.55 MB
BOQ_2243090.xls
BOQ • 0.23 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart shows the information on this page on a best-effort basis and does not guarantee that it is accurate, complete or current. Check it against the buyer's official notice and documents before you act on it; the official record prevails. TenderKart is not liable for any loss or claim arising from the use of this information. If you notice any error or omission, please let us know at .