Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹2.4 LAccepted-AOC 10 BRIJ VATIKA LAXMIPURA JAIPUR RAJASTHAN 302022 | JAIPUR | JAIPUR | RAJASTHAN | 302022 | L1 | Accepted-AOC Awarded by the competent authority | |
| 2 | L2₹2.4 L+₹4,006 (1.68%)Rejected-Finance | L2 | Rejected-Finance Rejected by the committee |
Tender Value
₹2.5 L
EMD Value
₹5,003
Closing Date
16 Dec 2024, 4:00 pmClosed
Executive Engineer Electrical BSNL Gorakhpur
Telephone Exchange Raptinagar Gorakhpur
Dismantling Shifting and installation of15 KVA Canopy EA set from Azadchauk to TE manglepur 32.5 KVA trolley EA set from NautanawatoAnandnagrEI work in DGM OA office TE Civil Lines S/F of submersible pump Taramandal store OA Gorakhpur.
2024_BSNL_217862_1
29/TED/GKP/2024-2025
Open Tender
Electrical Works
Item Rate
30 days
Gorakhpur
Please refer Tender documents.
2 documents required · 2 mandatory
₹590
ACCOUNTS OFFICER(Cash)BSNL O/o The GMTD GORAKHPUR
₹5,003
17 Jan 2025
5 Dec 2024
18 Dec 2024
5 Dec 2024
16 Dec 2024
5 Dec 2024
A. Shifting and Installation of EA sets:- 1. Shifting of 32.50 KVA EA set along with trolley from TE Nautanawa to TE Anandnagar i/c Loading ,unloading and lifting at both ends with the help of crane, labours etc complete as required.
2. Dismantalling & shifting of 15.0 KVA EA set in Canopy from Azad Chauk BTS to TE Manglepur i/c Loading ,unloading and lifting with the help of crane, labours & transpotation of 15.0 KVA EA set from Azad Chauk to Manglepur i/c dismantling of Canopy ,EA set as required and reassembling EA set & canopy properly etc. complete as required.
3. Installation of dismantled & shifted 15 KVA EA set & accessories at TE manglepur i/c making connections propery ,testing,Commissioning etc as required.
4. Providing and making lock & key arrangement for existing 15 KVA EA set in canopy with the help of welding machine, iron rods & hooks etc complete as reqd.
5. Repairing of self starter of 15 KVA EA set i/c connection,testing etc complete as reqd.
6. Repairing of fuel injection pump & fuel injector of 15 KVA EA set i/c cleaning recalibration with replacement of repair kit element delivery valve i/c testing etc complete as reqd.
7. Running test of EA set on load by providing required diesel & making connections properly on both ends of EA set etc.complete as reqd
8. Replacement of main fan belt, Charging alternator belt,house pipe,fuel supply & returning pipe, clamps etc.complete as reqd.
9. Repairing of Alternator with replacement of faulty AVR and diode plate of 15 KVA EA set i/c cleaning & making coneection properly ,testing etc complete as reqd.
B. Replacement of Submersible pump at Taramandal store:- 1. Replacement of 2.0 HP capacity submersible motor pump set suitable to operate on 3 phase 415 volt AC supply and capable to lift water upto 3rd floor building. Pump shall be of 8 stage, with head range 40-13 M and discharge flow range shall be 6-14 cum/hr. on operating speed 2860 RPM. (Make - KSB or similar superior make)
2. Replacement of PVC insulated PVC sheathed 3x2.5 sq mm multicore copper conductor submersible cable. (Make - M/s Havells or similar superior make)
3. Replacement and tieing PVC quoted steel wire rope with the submersible pump and GI pipe for safety of the pump as reqd.
4. Labour charges for lifting of the old/faulty submersible pump from the borewell with the help of tripole and pulley arrangement and lowering of the new submersible pump in to the borewell i/c testing etc as reqd.
5. Replacement and fixing of direct on line motor starter having contactor coil 360 volt rating and over load relay of 9-14 amp range for protection of the motor. It shall have start/stop push buttons and ampere and volt meters of suitable range i/c connection, testing etc as reqd. (M/s L&T Model No MU-G6 or Similar Superior make)
6. Replacement of 32 Amp 3 Pole isolator i/c fixing, connection, etc complete as reqd. (M/S L&T/Havells/S.s make)
7. Replacement of 40 mm dia B class GI pipe for existing submersible pump i/c sockets,bends etc all accessories,fitting & fixing etc as reqd.
8 . Replacement of 63 Amp 4 pole on load change over switch in sheet steel enclosure i/c connection, testing etc complete as reqd. (At TE Taramandal)
C. Electrical Installation work:- Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface medium class PVC Casing caping with piano type switch, phenolic laminated sheet, suitable size M.S. box and earthing the point with 1.5 sq.mm. FRLS PVC insulated copper conductor single core cable etc. as required (a) Group C
1. Supply and fixing of 20x10mm pvc casing caping/20 mm dia PVC pipe on surface for drawing of wires for connection etc complete as reqd.
5. Supplying and fixing switch box of 180mm X 100mm X 60mm deep (nominal size) on surface or in recess with suitable size of phenolic laminated sheet cover in front including providing and fixing 6 pin 5/6 & 15/16 A socket outlet and 15/16 A piano typeswitch, connections, painting etc. as required.
2. Supplying and fixing of switch box of Suitable sizes on surface or in recess with suitable size of phenolic laminated sheet cover in front including painting etc. as required.
3. Supplying and fixing following piano type switch/ socket on the existing switch box/ cover including connections etc. asrequired. (a) 5/6 amps switch
(b) 5/6 amps socket
4. Supplying and fixing following piano type switch/ socket on the existing switch box/ cover including connections etc. asrequired. (a) 3 pin 15/16 A socket outlet
(b) 6 pin 15/16 A socket outlet
5. Supplying and drawing of following size PVC insulated copper conductor cable in existing steel/PVC conduit etc as required. (a) 1.5 sqmm
(b) 2.5sqmm
6. Supply and Fixing of 400 mm sweep wall fan i/c connection, testing etc as reqd.
7. Supply and Fixing of 1200 mm sweep ceiling fan i/c regulator, connection, testing etc as reqd.
8. Supply and Fixing of electronic regulatorfor ceiling fan fan i/c connection, testing etc as reqd.
9. Supplying and fixing of 20 W LED tube fitting i/c connection,testing etc .complete as reqd.
10. Providing and installation of 300mm exhaust fan suitable for operation on 230 V ,50 Hz AC supply i/c cutting the wall,making good the damages etc. and all accessories, connection,testing etc complete as reqd. (Make - Crompton or similar superior make)
11.Providing and fixing of shutter for 300mm exhaust fan i/c nit bolts,screws etc complete as reqd.
M/S HARIOM ENTERPRISES (BID ID -787683)
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .