Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹4.8 CrAccepted-AOC C O GUPTA EMPORIUM AR BAZAR HAPPY VALLEY SHILLONG 793 004 | EAST KHASI HILLS | MEGHALAYA | 793004 | ₹4.8 Cr | L1 | Accepted-AOC Being lowest and reasonable |
| 2 | L2₹5.0 Cr+₹18.3 L (3.82%)Rejected-Finance | ₹5.0 Cr+₹18.3 L (3.82%) | L2 | Rejected-Finance Not Being Lowest |
| 3 | L3₹6.6 Cr+₹1.8 Cr (38.2%)Rejected-Finance 34 KAISER GANJ MANDI DIST MEERUT UP 250002 | MEERUT | UTTAR PRADESH | 250002 | ₹6.6 Cr+₹1.8 Cr (38.2%) | L3 | Rejected-Finance Not Being Lowest |
| 4 | Rejected-Technical 155 KARNAL NEW GRAIN MARKET KARNAL KARNAL HARYANA 132001 | KARNAL | HARYANA | 132001 | - | - | Rejected-Technical Bidder not fulfills NIT criteria as not IP not submitted |
Tender Value
Refer Docs
EMD Value
₹5.3 L
Closing Date
16 Apr 2022, 6:00 pmClosed
Chief Engineer Shillong Zone
HQ Chief Engineer Shillong Zone, Spread Eagle Falls Shillong -793011
PROVISION OF ADM BLOCK AT 58 GTC SHILLONG UNDER GE SHILLONG
2022_MES_498794_1
CESZ/SHL/23 OF 2021-2022
Open Tender
Civil Works
Lump-sum
547 days
GTC Shillong
As per NIT
2 documents required · 2 mandatory
₹2,000
GE Shillong
₹5.3 L
Yes
17 May 2022
1 Jan 2022
18 Apr 2022
1 Jan 2022
16 Apr 2022
28 Feb 2022
3 Jan 2022 - 10 Jan 2022
Amount
NOTE:- (Applicable for all parts/items/):- The bidders/contractors are advised to read tender document, all drawings & all corrigendum/ amendments and General conditions of contracts before entry/quoting the rates.
Lumpsum price workedout by the tenderer for BUILDING & STRUCTURE WORKS as listed in Schedule ‘A’ Part-I
Lumpsum price worked out by the bidder/ tenderer for SITE CLEARANCE, SITE DEVELOPMENT, EXCAVATION AND EARTH WORK as listed in Schedule 'A' Part-II.
Lumpsum price worked out by the bidder/ tenderer for INTERNAL Water Supply as listed in Schedule 'A' Part-III.
Lumpsum price worked out by the bidder/ tenderer for INTERNAL ELECTRIFICATION as listed in Schedule 'A' Part-IV.
Lumpsum price worked out by the bidder/ tenderer for ROADS/CULVERT/ PATH & HARD STANDING as listed in Schedule 'A' Part-V.
Lumpsum price worked out by the bidder/ tenderer for SEWAGE DISPOSAL as listed in Schedule 'A' Part-VI.
Lumpsum price worked out by the bidder/ tenderer for AREA DRAINAGE as listed in Schedule 'A' Part-VII.
Lumpsum price worked out by the bidder/ tenderer for COMPOUND WALL/SECURITY FENCING/GATE as listed in Schedule 'A' Part-VIII.
Lumpsum price worked out by the bidder/ tenderer for EXTERNAL WATER SUPPLY as listed in Schedule 'A' Part-IX.
Lumpsum price worked out by the bidder/ tenderer for EXTERNAL ELECTRIFICATION as listed in Schedule 'A' Part-X.
Lumpsum price worked out by the bidder/ tenderer for RETAINING WALL as listed in Schedule 'A' Part-XI.
Lumpsum price worked out by the bidder/ tenderer for LIGHTING PROTECTION as listed in Schedule 'A' Part-XII.
Lumpsum price worked out by the bidder/ tenderer for HOT WATER SUPPLY as listed in Schedule 'A' Part-XIII.
Lumpsum price worked out by the bidder/ tenderer for DEMOLITION AND DISMANTLING as listed in Schedule 'A' Part-XIV.
Sch 'A' Sec-VIII (Miscellaneous Items)Note : This schedule is not pre-priced by MES and the pre-priced rate indicated as "Rs 0.00" under Col. 5 signifies this fact only.
S&F of brass chromium plated health faucet with health faucet tube of 1.2 mtr long and standered accessories etc. suitable for 15mm bore pipe for WC all as specified and directed by Engr-in-Charge
M & L for Concealed Point wiring with 1.5 Sqmm (nominal cross-sectional area) FRLSH PVC insulated & unsheathed 1100 volts grade multi stranded copper conductor single core cable drawn through and including non-metallic rigid PVC conduit of adequate size with all fittings and accessories including mild steel terminal boxes with laminated sheet for mounting switches, socket, regulators etc complete including FRLSH PVC insulated & unsheathed single core multistranded copper conductor cable of size 1.5 Sqmm green in colour as earth continuity conductor connected to common earth and earth dolly for one light/fan point controlled by one, one way switch 6 amps complete all as specified and directed by Engr-in-Charge
M & L for Concealed Point wiring with 1.5 Sqmm (nominal cross-sectional area) FRLSH PVC insulated & unsheathed 1100 volts grade multi stranded copper conductor single core cable drawn through and including non-metallic rigid PVC conduit of adequate size with all fittings and accessories including mild steel terminal boxes with laminated sheet for mounting switches, socket, regulators etc complete including FRLSH PVC insulated & unsheathed single core multistranded copper conductor cable of size 1.5 Sqmm green in colour as earth continuity conductor connected to common earth and earth dolly for One light point controlled by Two, Two way switches complete all as specified and directed by Engr-in-Charge
M & L for concealed Point wiring with 1.5 Sqmm (nominal cross-sectional area) FRLSH PVC insulated & unsheathed 1100 volts grade multi stranded copper conductor single core cable drawn through and including non-metallic rigid PVC conduit of adequate size with all fittings and accessories including mild steel terminal boxes with laminated sheet for mounting switches & socket, including one run of FRLSH PVC insulated & unsheathed single core multistranded copper conductor cable of size 1.5 Sqmm green in colour as earth continuity conductor connected to common earth and earth dolly for One 3 pin socket outlet 5 Amps independent board complete all as specified and directed by Engr-in-Charge
M & L for concealed Point wiring with 1.5 Sqmm (nominal cross-sectional area) FRLSH PVC insulated & unsheathed 1100 volts grade multi stranded copper conductor single core cable drawn through and including non-metallic rigid PVC conduit of adequate size with all fittings and accessories including mild steel terminal boxes with laminated sheet for mounting switches & socket, including one run of FRLSH PVC insulated & unsheathed single core multistranded copper conductor cable of size 1.5 Sqmm green in colour as earth continuity conductor connected to common earth and earth dolly for One call bell point controlled by one bell push all as specified and directed by Engr-in-Charge
M & L for Concealed Point wiring with 4 Sqmm (nominal cross-sectional area) FRLSH PVC insulated & unsheathed 1100 volts grade multi stranded copper conductor single core cable drawn through and including non-metallic rigid PVC conduit of adequate size with all fittings and accessories including mild steel terminal boxes with laminated sheet for mounting switches, socket, regulators etc complete including FRLSH PVC insulated & unsheathed single core multistranded copper conductor cable of size 4 Sqmm green in colour as earth continuity conductor connected to common earth and earth dolly for one 5 pin 15 Amps socket outlet on independent board all as specified and directed by Engr-in-Charge
M&L sub main wiring (concealed type) single core FRLSH PVC insulated unsheathed cable, 1100 volts, grade having multi stranded copper conductor of 6 sqmm nominal cross sectional area each drawn into and all accessories including one No single core 6 sqmm copper conductor green in colour for earth continuity conductor connected to earth dolly complete all as specified & as directed by Engr-in-Charge. (Note - Two run single core cable, One run of earth conductor and one run of PVC conduit shall be measured as a unit length.)
M&L sub main wiring (concealed type) single core FRLSH PVC insulated unsheathed cable, 1100 volts, grade having multi stranded copper conductor of 10 sqmm nominal cross sectional area each drawn into and all accessories including one No single core 10 sqmm copper conductor green in colour for earth continuity conductor connected to earth dolly complete all as specified & as directed by Engr-in-Charge. (Note - Two run single core cable, One run of earth conductor and one run of PVC conduit shall be measured as a unit length.)
S&F LED batten with extruded aluminium housing and extruded aluminium heatsink for mounting LEDs, mercury free, inbuilt driver and decorative end cap maximum power consuption 20-22W with system level output of 2050 lumens @ 6500 CCT operating voltage of 140 -270 V AC PF ˃ 0.9, 2.5KV surge protection and current THD ˂=15 %. life class not less than 40000 burning hours as per L70 complete with all accessories including connecting of with twin core of PVC insulated 0.75 sqmm copper conductor cable upto ceiling rose complete all as specified & as directed by Engr-in-Charge.
S&F LED batten with extruded aluminium housing and extruded aluminium heatsink for mounting LEDs, mercury free, inbuilt driver and decorative end cap maximum power consuption 9-10W with system level output of 950 lumens @ 5700 CCT operating voltage of 140 -270 V AC PF ˃ 0.9, 2.5KV surge protection and current THD ˂=15 %. life class not less than 40000 burning hours as per L70 complete with all accessories including connecting of with twin core of PVC insulated 0.75 sqmm copper conductor cable upto ceiling rose complete all as specified and directed by Engr-in-Charge
S & F LED security light made up of pressure die cast alluminium housing with high power LED as light source and lense embedded PC cover having TOP OPENING separate driver compartment with IP65 protection, maximum power consuption 20-25 watt with system level output 2000 luman @ 5700 CCT,and CRI˃70, PF ˃0.9, THD ˂ 10 %, operating voltage 230 Volt and impact resistance of IK07, with all accessories including suitable bracket of 32mm bore light grade GI pipe bend to shape, including MS clamp of required size and PVC cable 1.5 Sqmm twincore from ceiling rose to light fittings complete all as specified and directed
S & F LED light fitting, 1 x 18 watt (porch light) round shaped surface mounted LED luminaire, 230 volts, complete with all accessories including and connecting with twin core of PVC insulated 0.50 Sqmm copper conductor cable complete all as specified and as directed by Engineer in Charge.
S & F Energy saving LED light fitting, 1 x 40 watt, 230 volts, Decorative ultra slim linear LED lighting fixture with extruded polycarbonate, environmental friendly, energy efficient ready to use pack. with electronic driver and high lumen output, 2.5 KV voltage surge protection, PF 0.98, THD < 10% suitable for surface/pendant mounting complete with all accessories including and connecting of with twin core of PVC insulated 0.75 Sqmm copper conductor cable complete all as specified and directed by Engr-in-Charge
M&L Soling (or subbase) with broken boulders, of quarried stone, of spread thickness 250mm interstices filled, surface formed and rolled and consolidated to required gradient and camber and rolled with 8 to 12 tonne power roller and consolidated to required gradient and camber complete all as specified and as directed by Engineer in Charge.
M&L for pre polished Chequered cement concrete tiles 30cm x30cm x 25mm thick, set, jointed and pointed in neat cement slurry in floors with grey cement and pigments complete all as specified and as directed by Engineer in Charge.
M & L for DWCPE(SN4) pipes nominal dia 150(Inner Dia) mm diameter Pipes) laid on any depth of trenches including jointing/cutting as required length pipes with jointing with socket/spight with elastomeric sealing complete activities to execute and make sewer line functional all as specified and directed by Engr-in-Charge
Supply and erect/construction of LLDPE modular Vertical /Horizontal Septic Tank 50 users capacity, made out of polyethylene resins, designed to carry sewage and sludge water including inlet, outlet & vent shaft pipe, valve & all necessary civil works as required with all fittings, fixtures etc. complete all as specified
M & L for Soakage wells for 50 Users, with all fittings and fixtures complete all as specified and shown on drawing No. TD/SZ/502 sheet No 1/1
M&L for stainless steel letters 150 mm size with grade of 304 SS sheet standard thickness as approved by GE to be provided in steel Main gate all as specified and directed.
M&L for stainless stell Logo of 58 GTC for 5.50 mtr wide Steel gate all as specified and directed.
Material and labour for cutting the existing steel tubing of size 80 mm dia for add/altn and screwing existing steel tubing after altn including provn of new necessry fittings such as union, bends, tee, reducer, nipples, sockets etc and new PPR pipe of size 50 mm outer dia complete all as specified and directed.
M&L for Valve Chamber of Size 60cmx60cmx60cm complete all as specified and shown in drawing.
Supply, install, testing and commisioning of distribution transformer step down, copper wounded having primary side for HT three phase 11 KV & secondary for 433 Volts, 3 phase, 50 Hertzs capacity of 160 KVA with the following specification :- (i) No load voltage ratio- 11/0.433 KV, (ii) Nos of phase - Three (iii) Type of cooling-ONAN. (iv) Frequency - 50 c/s (v) Vector group-DYN 11 (vi) Two earthing treatment for body earthing terminals for body earthing and two additional for neutral brought out on a bushing. (vii) Oil level gauge indicating oil level minimum and maximum. (viii) Lifting lugs. (ix) Rating and terminal making plates. (x) Dehydrating breathing device which would not permit ingress of moisture, rain water and insects. (xi) Drain-Cum-sampling valve (3/4" norminal size thread) preferably steel with plug. (xii) Thermometer pocket (for ttansformer of rating above 25 KVA). (xiii) oil filling hole (1-1/4" Nominal size thread) with cover (for transformers without conservator).
ITEM NO 15.23 CONT..... (xiv) Connection- Delta/Start (xv) Temprature rise in oil - 45 deg Centigrade (xvi) Temperaure rise in windings - 55 deg Centigrade. (xvii) Material winding-Copper wound (xviii) High voltage/low voltage-Bushing with box. (xix) Service-outdoor type (xx) Neutral- Internally connected with earth lrad and bush. (xxi) Off load tap changing ( ± 7.5% in steps of ± 2.5%) (xxii) Transformer supplied by the contractor shall comply energy efficient with energy efficient level 1 category of transformer manufactured by licensed OEM, as per IS : 1180 (Part-I) : 2014 (xxiii) FITTING ACCESSORIES:- as per clause no 149, 14.1.2 of SSR. (xxiv) Suitable plinth of height for installation of transformer.
Material and Labour for sand filling around the cable with approved quality coarse and for sand cushioning for under ground cable including spreading and puning down desired thickness compete all as specified and as directed.
M&L for 150mm thick cutting in any type of road, hardstanding etc and making good to disturbed surfaces with PCC, type B1, 1:2:4, (using 20mm graded stone aggregates) including coping / benching including wheathing slightly chamfered on edges and finishes exposed surfaces even and smooth without using extra cement including necessary formwork etc complete all as specified and as directed by Engr-in-Charge. Note: earthwork and pcc shall be measured and paid separately in relevant items if thickness will increased beyond 150mm
Supply and erect 2 pole structure on 11 meter steel tubular pole cosisting of anti climbing device, PCC foundation & cross arms etc complete all as specified and as directed by Engr-in-Charge.
M&L Earthing complete with galvnised steel earth plate electrode 60cm x 60cm x 60cm thick buried directly in ground (Earth pit not less than 2.25 mtr deep below normal ground level) with top edge of the plate not less than 1.5 mtr below normal fround level connecting with GI Strip 32mm x 6mm by means of bolt nut check nuts and washers of galvanised iron including PCC with 1:2:4 type B-1 using 20mm graded stone aggregate CI frame and cover of angle iron 25x25x6mm with 6mm dia MS bar made to shape, GI medium grade 20mm bore pipe for watering common salt chorcoal funnel wiremesh and eartwork in any type of soil returnign filling in and removal of soft/loose soil to a distance n. exc 5 mtr including earth test point and making connections, testing on completion all as per electric plate No 5 of SSR Part -I and directed by Engr-in-Charge at site.
M&L for earthing with galvanised steel earth plate 600x600x6 mm thick buried directly in ground (earth pit not less than 2.25 mtrs deep below ground level) with top edge of the plate not less than 1.5 meters below normal ground level connected to galvanized iron earth wire 4 mm as earthing lead by means of bolts nuts check-nuts and washers of galvanized iron or steel besides welding at all joints as shown in drawings and including excavation and earth work GI pipe light grade 15mm bore for protection of GI wire from earth electrode to earth dolly including earth earth test point of galvanized iron or steel of size 75x75x25 mm supplying and laying char coal dust and common salt PCC 1:2:4 type B-1 chamber and MS angle frame 40 x 40 x 3 mm and RCC cover 40 mm thick (1;2:4) type B-1 using 20 mm graded stone aggregate reinforced with 6 mm dia round bars @ 75 mm C/C both ways with MS handle 12 mm dia GI funnel and wire mesh 20 mm dia GI pipe light grade for watering all as shown in drawing and connected to earth test point including testing complete all as specified and directed.
Material and labour Street light bracket, made out of 40 mm dia GI pipe (medium grade) 1.5m long bend to shape as required and welded and fixing in position including dismantling and taking down old unserviceable bracket complete all as specified and directed.
Supply and fixing factory made IP-65 (Dust and power jet Proof according to IEC 60529) opaque street light junction box of size 260 mm x 210 mm x 116mm made of high quality polycarbonate (shock proof, rust free, corrosion free acid and chemical resistant, fire retardant having high impact (IK 08) totally insulated made of halogen and silica free recyclable material, UV resistant having high grade gasket made of polyurethane with copper terminal , MCB SP 6 Amps rating 10 KA with locking arrangement and 2 Nos M40 size cable gland and one M32 size gland suitable up to 35 Sqmm cable etc complete all as specified and directed.
S&F cable route indicator made out of 35x35x6 mm angle iron 150 mm clear height with 100 mm embedded in PCC 1:3:6 type C1(using 20 mm graded stone aggregate block of size 200x200x200 mm with letter MES HT cable suitabley inscribed on CI circular plate 100 mm dia 5mm thickwelded with angle ironincluding necessary earth work and two coat of synthetic enamel paint brown colour over acoat of red oxide primer on steel surface complete all as specified and directed.
Supply, install, testing and commisioning of LT distribution Panel board, double door,outdoor cubicle Type , front and rear opening with locking arrangement factory made epoxy powder coated, dust and vermin proof, pre wired CPRI approved made out of 3.15 mm thick CRCA sheets and 40 X 40X 5 mm MS angle iron frame having the cable from bottom sheet suitable for accomadate and including the following accessories and foundation work at site . INCOMING (a) MCCB 4 pole 250 Amps, 25 KA breaking capacity as incoming -01 Nos (c)400 Amps rated Al busbar of suitable size, 3 phase 4 wire system -01 set (d)Phase indicator lamp neon type RYB(Set of three)-01 set (e) Digital Panel Meter for Amp, Volt, power Factor and other parameter flush mounting of size 96x96 mm supply-01 Nos (f) Cable gland as per suitable size . OUTGOING (j) MCCB 4 pole 200 Amps, 25 KA,415 Volts, with thermal magenetic release, etc complete (out going )-01Nos. (ii) MCCB 4 pole 100 Amps, 16 KA, 415 Volts, with thermal magenetic release, etc complete (out going )-01Nos.
Supply, install, testing and commisioning of LT distribution Panel board, double door,outdoor cubicle Type , front and rear opening with locking arrangement factory made epoxy powder coated, dust and vermin proof, pre wired CPRI approved made out of 3.15 mm thick CRCA sheets and 40 X 40X 5 mm MS angle iron frame having the cable from bottom sheet suitable for accomadate and including the following accessories and foundation work at site . INCOMING (a) MCCB 4 pole 200 Amps, 25 KA breaking capacity as incoming -01 Nos (b)ON Load Changeover Switch disconnector of 400 amps cap in sheet enclosure -01 Nos (c)400 Amps rated Al busbar of suitable size, 3 phase 4 wire system -01 set (d)Phase indicator lamp neon type RYB(Set of three)-01 set (e) Digital Panel Meter for Amp, Volt, power Factor and other parameter flush mounting of size 96x96 mm supply-01 Nos (f) Cable gland as per suitable size . OUTGOING (j) MCCB 4 pole 100 Amps, 16 KA,415 Volts, with thermal magenetic release, etc complete (out going )-03Nos. (iii)MCB 2 pole 32 Amps,230 Volts, with thermal magenetic release, etc complete (out going )-02Nos.
M & L for exterior grade wall tiles with stone finished each of area not exc 0.20 sqm fixed to wall with clips/screed bed complete all as specified and directed.
M & L for 20-22 mm thick figuered toughened glass as in door with necessary top and bottom hinges and SS handles each face fixed as per manufacturer instruction complete all as specified and directed
M & L stainless steel (SS) railing with 12mm toughned glass class 3/5 and 25mm dia internal balusters and top rail of 50 mm dia pipe, 1.5mm thickness complete all as specified and directed
M &L for main logo of GTC on toughtened glass of 12mm thick glass projecting from wall duly fixed with SS spacers complete all as specified and directed
M &L for sign board of size 6.5m length and 0.60m height made out of 50mm dia CP steel hollow tubes all around on sign board and embeded on gate pillars with two pipes with 50mm CP steel tubes at each pillar as required height and the two sides of the sign board should be retro reflective sheets (blue and white colour) and letter writing (size of letters and sample of board shall be carried out as directed and specified and approved by GE
M &L 2in 1 CP 15mm bib taps quarter turn screwed for iron pipe or for union complete all as specified and directed
S&F 15mm bore brass CP basin centre hole mixer with long bend for mixing hot and cold water screwed down for iron pipe complete all as specified and directed
S&F 15mm bore brass CP sink mixer with long bend for mixing hot and cold water screwed down for iron pipe complete all as specified and directed
Supply,install, testing and commissioning of Silent Diesel engine driven generating set 415 Volts 3 phase 4 wire engine as per BS 5514/ IS 10002 and alternator, DG Set Size 3600 x 1200 x1710 mm as per IS : 13364 complete with , control panel having meters, sound proof canopy and PCC foundation etc for capacity 125 KVA as per ISO - 8528 conforming to the detailed specification as under:- a) Engine : The Diesel Engine shall be radiator water cooled, 154 BHP at 1500 RPM , Cylinder 6 Nos. Starting stopping : Electrical start with 12 V DC 1 x 90 AH, 12 V Exide / Prestolite Low Maintenance Battery,Mechanical governer , The fuel tank provided shall be suitably mounted on the base frame fabricated out of 16 SWG MS sheets and capacity to run the genset for 8 to 12 hours continuously on full load. Fuel tank shall have Drain plug, Hand hole for cleaning, vent breather, fuel suction and return connections, fuel level indicator fuel filling neck with cap etc as per the standards. The engine and alteranator shall be directly coupled to ensure perfect alignment. The engine and alternator shall be mounted on a common base frame with AVM pads all as per manufracturer
ITEM NO 15.43 CONT...... (b) Alternator : Rating 100KW /125 KVA at 1500 RPM 415 V Phase to Phase and 240 Volt Phase to Neutral, 50 Hz 3 Phase 4 wire system alternato Screen protected / drip proof, self ventilating, self excited, self regulated, brushless, contineous duy protention IP 21 as per IS 13364 developing 125KVA at 0.8 PF. It shall have provision for 10% overload for one hour on every 12 hours, The alternator shall confirm to IS : 13364/BS5000 (C) Controls/Protection : (i) Low LOP fault indication (ii) Indication for Water Temparature, (iii) High Colant Temparature fault Indication, (iv) Failure to start fault indication (v) Battery Volage monitoring, (vi) Low Battery Indication, (vii) Fuel level Indication, (viii) Engine RPM meter, (ix) Engine run hours meter, (x) Voltage for all three Phases, (xi) Amper meter for measuring current in all three phase. (xii) Frequency meter indication, (xiii) Protection for Over/Under Voltage (xiv) Electronic tamper proof KWH meter 3 phase, 4 wire system with suitable ratio CTs.
ITEM NO 15.43 CONT....... (xvi) Oveload protection (xvii)Suitable capacity of Battery charger shall be provided in the control panel to charge the batteries when mains supply in availbale. (xvii) Safeties against low Lube oil Pressure, high coolant Temperature, over load under & over voltage, under & over frequency Auto Shut Down, Visual & Audio Alarm against fault. When the Gen set is running the battery will be charged from the charging alternato (d) Acoustic enclosure : (i) Shall be maticulously designed CNC Turret punch press and hydraulic press brake manufractured body out of corrossion resistant cold rolled steel 16 SWG CRCA / MS sheet duly surface trated phosphated and finally powder coated constructed from folded sections to ensure regidness and aesthatic in looks. Canopy panel and doors shall have High density/ fire retradent / non igniting and noise reduction type Foam or Resin bonded Rock wool of suitable density properly covered with fibre cloth / tissue and perforated fixed to absorb noise. The average sound levell when measure in greenfiled (ISO 8525 Part 10) at 1 meter distance from all four sides is less than 75 dB (A) average as per CPCB Norms The average stablised hot air temperature rise with i the canopy near suction air filter to be maintained 7 degree centigrade over and above the ambient temperature Four higned doors shall be provided to canopy one door shall have glass window for control panel. The exhaust gasses shall be taken out through a suitable flexible pipe to prevent any back pressure on the engine. Provision shall be made on the canopy for connectig the output cable terminatiion should be provided. (ii) The eshaust system and noise suppressor shall be provided with thermal insulation, to prevent excess heat radiation on the Engine and safe for operator. (iii) Absorbtion type non residential silencer insulated from inside with glass wool shall be provided to suppress exhaust noise from the Engine. (iv) A suitably designed draught ventilation system is to be incorporated. (e) DG power Control Panel : Shall be outdoor type sheet steel type cubicle type control panel ,floor standing, dust and vermin proof under normal conditions complete with all internal wiring & will house the following:- (i) AC voltmeter (ii) AC ammeter (iii) vibrating reed Frequency meter
ITEM NO 15.43 CONT...... (iv) Indicating Lamps for SET ON & LOAD ON (v)MCCB for short circuit & Overload Protection (vi) Aluminium Bus bars of adequate rating (vii) Provision for bottom entry & Exit of power cabling (vii)set of current transformer (ix) set of control fuses
Design, supply, installation , testing and commissioning of variable refrigerant flow(VRF) air conditioning system suitable for heating/cooling with highly efficient DC inverter driven Scroll/rotary compressors complete with indoor and outdoor units with individual controllers and with fittings etc as per quantity given below. the compressors should have a intelligent soft start technology to achieve set temperature quickly. The VRF units should have wide operational range from -20 Deg C to 50 Deg C to ensure stable operation. The units are precharged with R-410A gas, complete with duly powder coated etc as required. The outdoor unit heat exchangers to be innovatively designed inner gooved type copper piping to enhance heat exchange and increase the subcooling of refrigerant to reduce system resistance and improve reliability. The heat exchangers to be specially designed for corrosion resistance and blue fin treatment. The units to be mod bus compatible and to have special night time silent operational feature and complete with individual Y joints/refnet joints for connecting IDU with refrigerant Piping with all accessories complete all as specified and directed. Note: Design of VRF system inincl indoor& outdoor unit layout, Electrical control wiring and panel, refrigerant gas pipe system & layout control valves etc duly approved by any vender, will be submitted for approved by the accepting Offr before installation.
ITEM NO 15.47 CONT.... (i)Outdoor Unit of capacity-22 HP (ii)Outdoor Unit of capacity-14 HP (iii)Indoor Hi-Wall Units of capacity 2.3 TR-1 Nos (iv) Indoor Hi-Wall Units of capacity 2.0 TR- 4 Nos (v) Indoor Hi-Wall Units of capacity 1.6 TR- 4 Nos (vi)Indoor Hi-Wall Units of capacity 1.5 TR- 3 Nos (vii)Indoor Hi-Wall Units of capacity 1.2 TR- 2 Nos (viii)Indoor Hi-Wall Units of capacity 1.0 TR- 8 Nos (ix)Indoor Hi-Wall Units of capacity 0.8 TR- 5 Nos
Design, supply, installation, testing and commissioning of on grid roof top solar power generation plant of capacity 20 KWp complete comprising of the following:- (a) Solar PV modules to meet comulative rated capacity of 20 KWp at STOC. Modules will be of mono Crystalline type with 72 cells and minimum rating of 390 Wp with positive tolerance, make and model of Made in India only with minimum 1000 mm cable length and glass thickness of PV modules shall be minimum 3.2 mm. Module efficiency >15.8%, Fill factor >0.7, module will be free of PID, module connected suitable for MC4/ Bizlink and juction box with minimum IP 67 rating. Module NOCT will be 45±5º C with temp coefficient of power <0.43 (Plus/minus) 0.02%/ degree celcius and will be suitable for operation from -20º C to +60º C ambient temperature. Modules will be combined to make array & string of panels to maximize power output along with supply and installation of necessary accessaries like fuses, array, string, junction box etc. Modules will be certified for relevant dust standards (Applicable standard would be IEC 60068-2-68). Modules shall be deployed with RF id tag inside lamination as per MNRE guidelines. Guaranteed electrical degredation of power generated not exceeding 20% of the minimum rated power over the 25 year period and not more than 10% after 10 years period of the full rated original output. Warranty against manufacturing, defects, raw materials, workmenship, inspection and testing procedure shall be 05years from the date of commissioning. Modules shall be certified as per IEC 61215-Edition-II, IEC-61646 and IEC-61730-1&2 and other applicable IEC/IES standards all as specified, the adequate qty to generate 20 KWp power.
ITEM NO 15.49 CONT...... (b) Design, supply, fabricate and fixed tilt module mounting structure hot dipped galvanised mild steel with coating not less than 85 microns and suitable to withstand wind speed upto 150 Km/Hrs and electrolytically compatible channels, bracing purlins of any size, electromagnetic washers, nuts, bolts including cutting, drilling etc. The design should be as per IS code and suitable for the wind speed (as per wind zone with correction of wind load at solar panel installation height), sun light and climatic condition of the plant location. Module ground clearance shall be 500mm ± 100mm. The design life should be more than 25years and minimum yeild strength of steel should be minimum 345 MPA and connecting plates yield strength shall be >250 MPA. Properties of RHS will confirm to IS 4923: 1997. HDG Fasteners of 4.6 grade and 8.8 grade for structure. The structure should be suitable for easy removing and refixing/ replacing of PV modules of the solar plant. All foundation and fixing arrangement shall be in according to drawing and as designed by structural engineer duly vetted by Accepting officer before execution of work- Qty adequate for mounting of solar PV modules at item 15.46 above,. (c) Supply and installation of branch, MC4 male/female connected set compatible with min of IP66 rating and design with suitable lugs for 6 Sqmm cable complete all as specified and directed- Adequate qty for 20 KWp solar power plant as per manufactures instruction. (d) Supply, install and laying with PVC conduits, lugs, nails, cable ties, termination etc, testing and commissioning of annealed single copper DC string cable of 1Cx6 Sqmm solar grade, UV resistant 1.5KV rated DC cables with elctron beam XLPO insulation confirming to IEC 60754-1 & IEC 60754-2, IEC 60332-1, IEC 60332-3-24, IEC 61034. Temperature range -40 to +120C complete all as specified and directed. Average energy loss in DC cabling shall be <1.5% from solar panel to inverter- Adequate qty for 20 KWp solar power plant as per manufacturers instruction. (e) Supply, install and laying with conduits,lugs,nails,cable ties,termination etc.,testing and commissiong of PVC insulated copper of 1Cx6 Sqmm for earthing conformingto IEC and IS standards-Adequate qty for 20 KWp Solar Power Plant as per manufactures instruction. (f) Supply, install and laying with PVC conduits,lugs,nails,cable ties,termination etc.,testing and commissiong of AC copper of 4Cx10 Sqmm from inverters to AC panels as per inverter and panel design,UV resistant 1.1 kV rated, PVC/XLPE insulation confirming to IEC and IS standards -Temperature range -40 to +120 C- Adequate qty foe 20 KWp solar powe plant as per manufactures instruction.
ITEM NO 15.49 CONT...... (g) Supply,installation,testing and commissioning of 3 phase ON-GRID inverter indoor type of with minimum IP 54 rating with 20 KW rated capacity, AC output at 50º C ambient temperature. Mininum European efficiency of the inverter shall be 98% load as per IEC-61683 standard and inverter supplied shall have upto 10% additional DC input capacity. (Array to Inverter ratio 1:1), 3 phase AC Nominal Output voltade 415 V (with ±10% range), Frequency 50 Hz (±1% range), PF at rated output capacity :1 (with range from 0.8 lag to 0.9 lead), Total THD: <3%, Operating temperature range : -20º C to +60º C .Inverters should consist of associated control,protection and data logging devices and remote monitoring hardware and compatible with software used for string level monitoring all as specified and directed .Other important features/protection required in the inverter are as under :- (i) Automatic morning wake-up and nightly shutdown. (ii) Mains (Grid) over-under voltage and frequency protection. (iii)Galvanic isolation and fool proof protection against ISLANDING. (iv) Included authentic tracking of the solar arrays maximum power operation voltage (MPPT). (v) Array ground fault dectection. (vi) LCD and Piezoelectric keypad operator interface Menu deiven. (vii) Automatic fault conditions reset for all parameter like voltage, frequency and /or black out. (viii) MOV type surge arrester on AC and DC terminals for over voltage protection from lightning-induced surges. (ix) Provision for input and output isolation. (x) Inverter shall be installed on GI stand made by the angle size 50mm x 50mm x 6mm. (xi) Structure install on ground/floor and shall be 450mm above ground level. Inverter shall adjust the voltage & frequency levels to suit the Grid. Note:- Any other items not mentioned on above description but if it is technically required for optimum performance of Solar Power Plant (SPP) shall br incorporated by the contractor without any extra cost to the department.
M/s Jony Enterprises
M/s Gupta Construction
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .